Supply Of Different Types Of Transmitters For 3X210 Mw Atps Anpara:- 1 Smart Pressure Transmitter ( With Hart Protocol ) -02 Wire System With 02 Way Manifold & Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: ( - ) 100 To ( + ) 100 Mmwcl 2 Smart Pressure Transmitter ( With Hart Protocol ) -02 Wire System With 02 Way Manifold & Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: ( - ) 300 To 0 Mmwcl 3 Smart Pressure Transmitter ( With Hart Protocol ) -02 Wire System With 02 Way Manifold & Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: ( - ) 100 To ( + ) 300 Mmwcl 4 Smart Pressure Transmitter ( With Hart Protocol ) -02 Wire System With 02 Way Manifold & Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 250 Kg / Cm2 5 Smart Pressure Transmitter ( With Hart Protocol ) -02 Wire System With 02 Way Manifold & Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 10 Kg / Cm2 6 Smart Pressure Transmitter ( With Hart Protocol ) -02 Wire System With 02 Way Manifold & Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 4 Kg / Cm2 7 Smart Pressure Transmitter ( With Hart Protocol ) -02 Wire System With 02 Way Manifold & Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 60 Kg / Cm2 8 Smart Pressure Transmitter ( With Hart Protocol ) -02 Wire System With 02 Way Manifold & Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 25 Kg / Cm2 9 Smart Pressure Transmitter ( With Hart Protocol ) -02 Wire System With 02 Way Manifold & Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Out-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 5Kg / Cm2 10 Smart Pressure Transmitter ( With Hart Protocol ) -02 Wire System With 02 Way Manifold & Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Out-4-20 Ma, Input Supply: 24 Vdc, Range: ( - ) 1 To 0 Kg / Cm2 11 Smart Diff. Pressure Transmitter ( With Hart Protocol ) -02 Wire System With Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 200 Mmwcl ( Working Pressure 400 Mmwcl ) 12 Smart Diff. Pressure Transmitter ( With Hart Protocol ) -02 Wire System With Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 100 Mmwcl ( Working Pressure 1000 Mmwcl ) 13 Smart Diff. Pressure Transmitter ( With Hart Protocol ) -02 Wire System With Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 17000 Mmwcl ( Working Pressure 156 Kg / Cm2 ) 14 Smart Diff. Pressure Transmitter ( With Hart Protocol ) -02 Wire System With Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 6300 Mmwcl ( Working Pressure 190 Kg / Cm2 ) 15 Smart Diff. Pressure Transmitter ( With Hart Protocol ) -02 Wire System With Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 500 Mmwcl ( Working Pressure 200 Kg / Cm2 ) 16 Smart Diff. Pressure Transmitter ( With Hart Protocol ) -02 Wire System With Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 12 Kg / Cm2 Mmwcl ( Working Pressure 200 Kg / Cm2 ) 17 Smart Diff. Pressure Transmitter ( With Hart Protocol ) -02 Wire System With Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 150 Mmwcl ( Working Pressure 200 Mmwcl ) 18 Smart Diff. Pressure Transmitter ( With Hart Protocol ) -02 Wire System With Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 1 Kg / Cm2 ( Working Pressure 2 Kg / Cm2 ) 19 Smart Diff. Pressure Transmitter ( With Hart Protocol ) -02 Wire System With Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: ( - ) 400 To 1200 Mmwcl ( Working Pressure 15 Kg / Cm2 ) 20 Smart Diff. Pressure Transmitter ( With Hart Protocol ) -02 Wire System With Suitable Fittings ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 9000 Mmwcl ( Working Pressure 25 Kg / Cm2 ) ( 0-800 T / H ) 21 Smart Universal Input Temperature Transmitter ( With Hart Protocol ) -02 Wire System ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 120 Deg C ( For Cu-K Thermocouple ) 22 Smart Universal Input Temperature Transmitter ( With Hart Protocol ) -02 Wire System ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 300 Deg C ( For Cu-K Thermocouple ) 23 Smart Universal Input Temperature Transmitter ( With Hart Protocol ) -02 Wire System ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 400 Deg C ( For Cr-Al Thermocouple ) 24 Smart Universal Input Temperature Transmitter ( With Hart Protocol ) -02 Wire System ( Technical Specs Are As Per Annexure Attached ) , Out Put-4-20 Ma, Input Supply: 24 Vdc, Range: 0 To 600 Deg C ( For Cr-Al Thermocouple )