Repair Maintenance Of Refrigeration And Air Conditioning Equipments And Other Connected Works At Dipatoli Mil Stn
Tender Value
20.52 Lakhs
Estimated cost
Bid Submission
23 Oct 2019
0 days left
EMD
41100
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
DIPATOLI → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair Maintenance Of Refrigeration And Air Conditioning Equipments And Other Connected Works At Dipatoli Mil Stn
BOQ
| Name of Work:- REPAIR / MAINT OF REFRIGERATION AND AIR CONDITIONING EQUIPMENTS AND CONNECTED WORKS AT DIPATOLI MIL STN | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | M&L for servicing/overhauling of Water cooler of capacity up to 60 Ltr, deep freezer/refrigerator up to 310 ltr of any make in existing site with and including provisioning of dismantling all electrical items/connected parts such as relay, capacitor, compressor grills etc and water descaling by using acid on both side of cooling coil and condenser cleaning with nylon brush and washing with clean water and drying by air blower, to ensure proper cleaning before reassembling complete unit and refixing at site including testing and commissioning complete all as specified and as directed at site to the entire satisfaction of Engr-in-Charge.\n Note :- (i) Any type T&P items as required shall be arranged by the contractor at no extra cost. \n(ii) Servicing shall be carried out on half yearly basis or as and when required. \n(iii) Cost of new nuts, bolts, washers as required at site will deemed to be included in quoted rates. \n(iv) Cost of spares/Refrigerant shall be measured and paid separately under relevant items. \n\n | 250 | Each\nJob | |
| 2 | 2 | M&L for servicing of Window/Split Type Air Conditioner of any make, size of 1.5/2 Ton Capacity from existing site with and including taking down and refixing in same position, all electrical items/connected parts such as relay, capacitor, compressor grills etc and water descaling by using acid on both side of cooling coil and condenser, cleaning with nylon brush and washing with clean water and drying by air blower, to ensure proper cleaning and cleaning of filter of indoor unit before reassembling complete unit and refixing at site including testing and commissioning complete all as specified and as directed at site to the entire satisfaction of Engr-in-Charge .\n Note :- (i) Any type T&P items as required shall be arranged by the contractor at no extra cost. \n(ii) Servicing shall be carried out on half yearly basis or as and when required. \n(iii) Cost of new nuts, bolts, washers as required at site will deemed to be included in quoted rates. \n(iv) Cost of spares/Refrigerant shall be measured and paid separately under relevant items. \n | 100 | Each | |
| 3 | 3 | M&L for cutting and taking out the rusted/damaged portion of the sheet metal of AC/WATER COOLER /Deep FREEZER/REFRIGARATOR of any capacity and providing new sheet of existing gauge including gas, welding/brazing as required, with and including painting with two coat of synthetic enamel paint over red oxide primer complete all as specified and as directed. | 10 | Each\nJob | |
| 4 | 4 | S&F in replacement of compressor unit by manufacturer with relevant warranty certificate including necessary charging the system suitable for 2 Ton Split type/ Window type AC as per existing make complete all as specified and as directed. | 10 | Each | |
| 5 | 5 | Description all as per ser item no 4 here in before but suitable for 1.5 Ton AC complete all as specified and as directed. | 12 | Each | |
| 6 | 6 | S&F in replacement of compressor unit by manufacturer with relevant warranty certificate including necessary charging the system suitable for Refrigerator upto 320 ltr capacity as per existing make complete all as specified and directed. | 14 | Each | |
| 7 | 7 | S&F in replacement of compressor unit by manufacturer with relevant warranty certificate including necessary charging the system with (R22/134A) suitable for Deep freezer upto 320 ltr capacity as per existing make complete all as specified and directed. | 5 | Each | |
| 8 | 8 | S&F in replacement of compressor unit by manufacturer with relevant warranty certificate including necessary charging the system suitable for Water cooler 60/120 ltr capacity as per existing make complete all as specified and directed. | 15 | Each | |
| 9 | 9 | Description all as per ser item no 8 here in before but suitable for 40/80 ltr capacity complete all as specified and as directed. | 18 | Each | |
| 10 | 10 | S&F in replacement of condenser coil for split type AC capacity up to 2 ton as per existing make & size complete all as specified and directed. | 12 | Each | |
| 11 | 11 | S&F in replacement of capilary tube for split type air conditioner capacity upto 2 ton as per existing make & size complete all as specified and as directed. | 15 | Each | |
| 12 | 12 | S&F in replacement of copper tube suitable for 2.0 Ton split type AC as per existing make & size complete all as specified and as directed. | 120 | Rm | |
| 13 | 13 | S&F in replacement of copper tube suitable for 1.5 Ton split type AC as per existing make & size complete all as specified and directed. | 120 | Rm | |
| 14 | 14 | Supply and fix in replacement of insulation suitable for 1/2\" copper tube as per existing make & size complete all as specified and directed. | 180 | Rm | |
| 15 | 15 | S&F in replacement of insulation suitable for 3/4\" copper tube as per existing make complete all as specified and directed. | 150 | Rm | |
| 16 | 16 | M&L for Refrigerant gas (R22/R32/R410/134A) for AC, water cooler, deep freezer and refrigerator complete all as specified and directed. | 190 | Kg | |
| 17 | 17 | S&F in replacement of front grill of window/split type AC capacity up to 2 ton as per existing make & size complete all as specified and directed. | 4 | Each | |
| 18 | 18 | S&F filter of split type AC capacity up to 2 ton as per existing make & size complete all as specified and directed. | 20 | Each | |
| 19 | 19 | S&F in replacement of fan motor suitable for 1.5 Ton Split type AC as per existing make & size complete all as specified and directed. | 12 | Each | |
| 20 | 20 | S&F in replacement of Fan motor suitable for 2 Ton Split type AC as per existing make complete all as specified and directed. | 8 | Each | |
| 21 | 21 | S&F in replacement of Fan motor suitable for water cooler capacity up to 60/120 ltr as per existing make complete all as specified and directed. | 15 | Each | |
| 22 | 22 | S&F in replacement of Fan motor suitable for water cooler capacity up to 40/80 ltr as per existing make complete all as specified and directed. | 18 | Each | |
| 23 | 23 | S&F in replacement of Fan motor suitable for Refrigerator upto 320 ltr capacity as per existing make complete all as specified and directed. | 12 | Each | |
| 24 | 24 | S&F in replacement of Fan motor suitable for Deep freezer upto 320 ltr capacity as per existing make complete all as specified and directed. | 6 | Each | |
| 25 | 25 | S&F in replacement relay of split type AC capacity up to 2 ton as per existing make & size complete all as specified and directed. | 30 | Each | |
| 26 | 26 | S&F in replacement starting capacitor of window/split type AC capacity up to 2 ton as per existing make & size complete all as specified and directed. | 40 | Each | |
| 27 | 27 | S&F in replacement of running capacitor of window/split type AC capacity up to 2 ton as per existing make & size complete all as specified and directed. | 40 | Each | |
| 28 | 28 | S&F in replacement of running capacitor of water cooler/ Refrigerator/ deep freezer as per existing make & size complete all as specified and directed. | 50 | Each | |
| 29 | 29 | S&F in replacement of Starting capacitor of Water cooler/Refrigerator/deep freezer as per existing make & size complete all as specified and as directed. | 50 | Each | |
| 30 | 30 | S&F in replacement of Thermostate switch of window/split type AC capacity up to 2 ton as per existing make & size complete all as specified and directed. | 25 | Each | |
| 31 | 31 | S&F in replacement of Fan Blade of window/split type AC capacity up to 2 ton as per existing make & size complete all as specified and directed.. | 15 | Each | |
| 32 | 32 | Description all as per ser item no 31 here in before but Fan blade suitable for refrigerator upto 320 ltr capacity as per existing make complete all as specified and as directed. | 10 | Each | |
| 33 | 33 | Description all as per ser item no 31 here in before but Fan blade suitable for Water Cooler upto 60/120 ltr capacity as per existing make complete all as specified and directed.. | 10 | Each | |
| 34 | 34 | Description all as per ser item no 31 here in before but Fan blade suitable for Water Cooler upto 40/80 ltr capacity as per existing make complete all as specified and directed. | 10 | Each | |
| 35 | 35 | Description all as per ser item No 31 here in before but Fan blade suitable for Deep freezer upto 320 ltr capacity as per existing make complete all as specified and directed. | 10 | Each | |
| 36 | 36 | S&F in replacement of PCB of window/split type AC capacity up to 2 ton as per existing size & make complete all as specified and directed. | 10 | Each | |
| 37 | 37 | S&F in replacement of Swinging motor of split type AC capacity up to 2 ton as per existing size & make complete all as specified and directed. | 5 | Each | |
| 38 | 38 | Disconnecting electrical connection and taking down/removing unserviceable single phase voltage stabilizer upto 5 KVA capacity of any make and transporting same to MES yard for annual repair/servicing/cleaning/maintenance. Dismantling the stabilizer segregating unserviceable/wornout parts, caryout repair including replacement of worn out parts, rewinding burnt out transformer as per existing reassembling all components and transporting the same upto its original position, fitting/fixing and testing for effictive working complete all as specified and as directed.\nNote:- New Spares shall be measured and paid as supply only here-in- after separately. However spare not mentioned in this schedule and required for smooth functioning of stabilizers are deemed to be included in the quoted rate under this item.\nNote : The under mentioned material under this contract shall be consumed under this item described here in above. | 30 | Each Job | |
| 39 | 39 | S&F in replacement of cut off relay of existing make for any type & make of voltage stabilizer upto 5 KVA capacity complete all as specified and as directed. Make : As per existing make | 15 | Each | |
| 40 | 40 | S&F in replacement of (PCB) circuit plate of existing make for any type & make of voltage stabilizer upto 5 KVA capacity complete all as specified and as directed. | 10 | Each | |
| 41 | 41 | S&F in replacement of Volt meter of existing make for any type & make of voltage stabilizer upto 5 KVA capacity complete all as specified and as directed. | 10 | Each | |
| 42 | 42 | S&F in replacement of fuse grip of existing make for any type & make of voltage stabilizer upto 5 KVA capacity complete all as specified and as directed. | 15 | Each | |
| 43 | 43 | S&F in replacement of control trnsformer of existing make for voltage stabilizer upto 5 KVA capacity of any make & type complete all as specified and as directed. | 10 | Each | |
| 44 | 44 | S&F voltage stabilizer Single Phase 230 Volts 50 Hz working range 130 Volts to 300 Volts, time delay 3 sec Capacity 5 KVA suitable for up to 2 Ton AC complete all as specified and as directed. Make : V-Guard Cat No VGB 500 or equivalent in Tata BP Pvt Ltd/Pandit | 15 | Each\n | |
| 45 | 45 | S&F single phase 230 volts 50 Hz voltage stabilizer suitable for refrigerator/deep freezers/water cooler working range 90 Volts to 260 Volts, time delay 3 min Capacity 1 KVA complete all as specified and as directed. Make : V-Guard Cat No VGSJW 100 or equivalent in Tata BP PvtLtd/Pandit | 16 | Each\n | |
| 46 | 46 | Attending breakdown /inspection of 7.5 TR capacity package type AC by OEM service engineer to check and replace any spares related breakdown complete all as specified and as directed at site. \nNote : \n(a) Spars shall be measured and paid separately under respective items.\n(b) A sum of Rs 2000/day shall be recovered in case of non attendance of break down by service Engineer and not rectified the defects within 24 Hrs.\n(c) The under mentioned material under this contract which are be consumed under this item described here in above. | 3 | Each\n Job | |
| 47 | 47 | M&L for pressure leakage testing of 7.5 TR package type AC unit with nitrogen gas complete all as specified and as directed. | 3 | Each | |
| 48 | 48 | M&L for Refrigerant gas (R22/134A) suitable for 7.5 TR package type AC complete all as specified and directed at site. | 36 | Kg | |
| 49 | 49 | M&L for servicing of cooling coil with coil cleaner of water cooled package type AC including all control panel servicing (electrical & electronics and checking all safety devices, cleaning by acid / suitable chemical for removing all foreign material gathered in the coil and re-fixing and testing complete all as specified and directed at site.\nNote : Servicing shall be carried out on half yearly basis or as and when required. \n | 6 | Each | |
| 50 | 50 | M&L for descaling of condenser coil of water cooled package type AC by circulating diluted hydro chloric cid and removing foreign materials shall be carried out as and when ordered by Engineer -in- Charge. | 3 | Each | |
| 51 | 51 | M&L for servicing of cooling tower including cleaning of cooling tower sump, fins cleaning and cleaning of Y- type stainer, cleaning by acid / suitable chemical complete all as specified and directed at site.\nNote :- (a) T&P items as required shall be arranged by the contractor at no extra cost. \n(b) Servicing shall be carried out on half yearly basis or as and when required. | 1 | Each | |
| 52 | 52 | S&F in replacement of cast iron body, non return valve of size 65 mm bore suitable for insertion between flanges complete all as specified and directed at site. | 2 | Each | |
| 53 | 53 | S & F in replacement of CI butterfly valve of size 65 mm dia complete including nuts, bolts & washers and 3 mm thick rubber gasket complete all as specified and as directed. | 6 | Each | |
| 54 | 54 | Dismantling the pump set 5 HP, 3 Phase, 415 volt of chiller pipe line at signal centre AC plant from MS base frame foundation, carrying to the local workshop, opening the top cover and repairing the same by replacing gland packing, interstage ring, ball bearing, impeller nut, gasket set, eye ball, O-ring including lathe/machining work for pump shaft and rewinding of 3 phase 50 Hz electric motor capacity 5 HP with super enameled copper winding wire of suitable gauge including insulating material, varnishing, heating etc and including replacement of bearings DE & ND side including dismantling assembling after rewinding to its original locations complete all as specified and directed at site\n | 2 | Each | |
| 55 | 55 | S&F in replacement, bourdon pressure gauge, 0-60 PSI rating, complete with 3/8 inch dia, S.S. syphon piping with gun metal cock valve in condensor pipe lines as per existing shape and size all as required. | 4 | Each | |
| 56 | 56 | M&L for fabrication and installation of GI sheet with TDF flanges rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of size 20 SWG complete all as specified and as directed at site requirment. | 50 | Sqm | |
| 57 | 108 | M&L for MS angle iron of round/square/rectangular shaped of any size for fixing of blower, motor and base frame /wall duly welded with MS hinges and locking arrangement including nuts, bolts, washers etc duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.\n | 150 | Kg |
AI Tender Summary
Tender Timeline
Oct 01, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedOct 23, 2019