}

Procurement Of Laboratory Instrument For Laboratory Facility Of C And I Dept Stage Ii 2 X 500 Mw For Sagardighi Thermal Power Project Wbpdcl, Sagardighi Thermal Power Project(SgTPP)-West Bengal

West Bengal Power Development Corporation Limited has published Procurement Of Laboratory Instrument For Laboratory Facility Of C And I Dept Stage Ii 2 X 500 Mw For Sagardighi Thermal Power Project Wbpdcl. Submission Date for this Tender is 24-10-2019. Laboratory Equipment Tenders in Sagardighi Thermal Power Project(SgTPP) West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

21991785
Procurement Of Laboratory Instrument For Laboratory Facility Of C And I Dept Stage Ii 2 X 500 Mw For Sagardighi Thermal Power Project Wbpdcl
Open Tender
Indian
West Bengal
Sagardighi Thermal Power Project(SgTPP)
24-10-2019

Tender Details

Procurement Of Laboratory Instrument For Laboratory Facility Of C And I Dept Stage Ii 2 X 500 Mw For Sagardighi Thermal Power Project Wbpdcl:-1 Test Bench With Pwr Supply N Accessories For Laboratory Instruments Self Contained Test Bench Made Of 2.5Mm Crca For Testing And Repair Of Electronic Instruments And Gadgets Shall Be Furnished.Rn1.M 0 Hz Single Phase , 2. Ac Power Sockets .Raw Power, 240V Ac / 15A / 5A, 3. Ac Power , Stabilized 230 V 15 A, With Power Socket, 240V Ac Y , Input Volts , 240V Ac, 50Hz, 1 Phase, Output Volts, 24Vdc , 5A , 5.Regulated Dc Power Supply, Input Volts , 240V Ac, 50Hz, 1 Phase, Ps, 0- 1Amp Adjustable , 6. Ac Power Supply With Sockets, Input Power Supply , 240Vac, 50 Hz, Power Socket, 110Vac, 5A, 7. Fixed Dc 2 Pr Regulator 0.06 To 2Kg / Cm2, With Pr G / G Forlaboratory Instruments Pressure Regulators-Range 0.06 To 2 Kg / Cm2, Accuracy 0.07 Kg / Cm2, Pressure Gauge-Range 0 To 10000 Mmwc , Digital Display 5 Digits, Accuracy ± 0.05 Fs, C. Output Co Nnection 1 / 4 In Bsp, Male. 3 Pr Regulator 0.06 To 4Kg / Cm2, With Pr G / G For Laboratory Instruments Pressure Regulators-Range 0.06 To 4 Kg / Cm2, Accuracy 0.03 Kg / Cm2, Pressure Gauge-Range 0 To 4 Kg / Cm2 , Digital Display 5 Digits, Accuracy ± 0.05 Fs, C. Output Conn Ection 1 / 4 In Bsp, Male 4 Pr Regulator 0.42 To 10Kg / Cm2 And Pr G / G For Laboratory Instruments Pressure Regulators-Range 0.42 To 10 Kg / Cm2, Accuracy 0.05 Kg / Cm2, Pressure Gauge-Range 0 To 10 Kg / Cm2 , Digital Display 5 Digits, Accuracy ± 0.05 Fs, C. Output Co Nnection 1 / 4 In Bsp, Male 5 Vacuum Gauge 1 To 0 Kg / Cm2, Dial 160 Mm For Laboratory Instruments Vacuum Gauge : - 1 To 0 Kg / Cm2 Rn Dialsize: 160 Mm, Accuracy: ± 0.25 Percentage F.Srnregulator : Suitable Regulator Will Be Providedrno / P Coupling : ¼ In Bsp, Male Connector Suitable For Hose Connection 6. Portable Vacuum P / P, Free Air Dis 240 Lpm For Laboratory Instruments Vacuum Pump, Free Air Displacement 240 Lit / Min, Ultimate Pressure 0.5Mbar, Motor 0.55 Kw, Voltage 220V, 50 Hz, Single Phase, Intake Fittings Kf 25, Oil Capacity 1 Lit, Rnrpm 1400, Portable Double Stage Pumps Compact And Sturdy Design 7 Digital Pressure Calibrator, 0 To 400 Bar For Laboratory Instruments Digital Pressure Calibrator Calibration Range 0 To 400 Bar Pressure, Accuracy +- 0.025Percentage F.S, Resolution Minimum 5 Digits, Switch Test Max. 9V , Automatic Temperature Compensation ( 0-50 Degc ) Touch Membrane Keypad Large Graphic Display; 15 Engineering Units; Pressure Gen Fine Adjustment Vernier; Inbuilt Battery Charger; Heavy Duty Casing. 8 Digital Pr Calibrator, -0.85 To 20 Bar For Laboratory Instruments Digital Pressure Calibrator Calibration Range: -0.85Bar To 20 Bar Pressure, Accuracy +- 0.025 Percentage F.S, Resolution Minimum 5 Digits, Switch Test Max 9V, Automatic Temperature Compensation Large Graphic Display; 15 Engineering Units; Pressure Generation Through Priming Pump & Fine Adjustment Vernier; Inbuilt Battery Charger; Heavy Duty Casing 9 Pneumatic Comparator, 0 -300 Psi, 0-2 Inhg For Laboratory Instruments Pneumatic Comparator Duel Pressure / Vacuum Capability Facility For High Quality Needle Valve For Fine Adjustment / Control, Built-In Hand Pump As Pressure / Vacuum Source With Necessary Test Port Adaptors. Pressure Range - 0 To 300 Psi Vacuum Range -0 To 27 Inhg, 10 Hydraulic Comparator, Pr Upto 700 Bar For Laboratory Instruments Hydraulic Comparator Comparison Tester For Pressure Upto 700 Bar Rngood Accuracy, Resolution, Repeatability Level Single Piston Type, Hydraulic Series 11 Standard Gauge, 0 To 700 Kg / Cm2, Bot Ent For Laboratory Instruments Test / Standard Gauge ( High Range ) Microprocessor Based 4 And1 / 2Digit Pneumatic Pressure Gauge With All Standard Fittings Specification Naccuracy ±0.1Percentage Of Full Scale, Range 0 To 700 Kg / Cm2, Entry Type Bottom Entry, Dial Minimum 3 Inch, Resolution 0.1 Kg / Cm2, Operating Temp Minimum 0-50D Egc Selectable Pressure Unit: Mbar, Bar, Kg / Cm2, Psi, Pa, Kpa, Mpa, Mmh2o 12 Pneumatic Test Pr G / G, -1 To 40 Kg / Cm2 For Laboratory Instruments Test / Standard Gauge ( Low Range ) Microprocessor Based 4 And1 / 2Digit Pneumatic Pressure Gauge With All Standard Fittingsrn Specifications Accuracy ±0.05 Percentage Of Full Scale, Range -1 To 40 Kg / Cm2, Entry Ty Bottom Entry, Dial Minimum 3 Inch, Resolution 0.01 Kg / Cm2, Operating Temp Minimum 0-50De Gc, Selectable Pressure Unit: Mbar, Bar, Kg / Cm2, Psi, Pa, Kpa, Mpa, Mmh2o 13 Analog Standard Gauge For Laboratory Instruments Range: -1 To 3 Kg / Cm2 Entry Type: Bottom Entry Dial: 250Mm Analog Standard Gauge ( Very Low Range ) Accuracy ±0.25% Of Full Scale Range -1 To 3 Kg / Cm2 Entry Type Bottom Entry Dial: 250Mm Resolution: 0.1 Kg / Cm2 14 Analog Standard Gauge For Laboratory Instruments 15 Temp Calibrator, Oil Bath , 35 To 250 Degc For Laboratory Instruments 16 Temp Calibrator, Dry Block, 50To 600Degc For Laboratory Instruments Temp Dry Block Calibrator 17 Thermometer With Probe, -100Degc To 1600 For Laboratory Instruments Thermometer With Probe Range -100 To 1600Degc Or Better Accuracy ±0.1Percentage Of Reading, -100 To 199Degc Or Better, ±0.2 Percentageof Reading, 200 To 1300Degc Or Better Resolution -100 To 199;0.1Degc Or Better 200 To 1300;1.0Degc Or Better 18 Laser Gun, Non Contact Thermometer For Laboratory Instruments Laser Gun, Non Contact Thermometer Range -60 To 760Degc Or Better Accuracy -35 To 0.1Degc; ±10Percentage Of Reading Or Better, 0 To 100Degc; ±2Degc Or Bette 100.1 To 500Degc; ±2Percentage Of Reading Or Better, 19 Tachometer, Both Optical And Contact Mode For Laboratory Instruments Portable Tachometer Range 1. Optical Mode 10To 99, 999 Rpm2. Contact Mode 10 To 20, 000 Rpm Accuracy ±0.02Percentage Of Indicated Reading Display4.5 Digit For Measurement And Measuring Unit, Accessories To Be Provided Contact Adapter, Surface-Speed Wheel, Convex And Concave Tips, Reflective Tapes, Battery Carrying Case Etc.. 20 Digitalmanometer, Range - 1000-0-1000 Mm For Laboratory Instruments 21 Soldering / De-Soldering Station , 430 Degc For Laboratory Instruments Multifunction Handheld Calibrator For Laboratory Instruments Handheld Calibrator, Sources And Measures Dc Voltage, Current, Resistance, Rtds And Thermocouples, Includes 24 V Dc Transmitter Loop Power Supply, Measures 4-20Ma Loop Current, Includes Automated Switch-Test Function, Accepts Its-90 Coefficients Measurements, Dc Voltage Source 23 Tong Tester Ac / Dc Clamp Meter 24 Continuity Tester For Laboratory 25 Lan Tester, Both Utp And Stp- 6 To 100M For Laboratory Instruments Lan Tester, Test Standard Ieee-802 And Eia / Tia 568, Range For Unshielded Twisted Pair Utp - 6 To 100M For Shielded Twisted Pair St To 60 M ± 0.6 M, 60 M To 185 M ± 1%, Resolution 1 M, Storage Allows Storage Of 400 Complete Test Results For Printing, Near End To 50 Db, Characteristic Impedance Range Tp Cable 75 - 180 Ohms With Accuracy Of ± 10 Ohms, Accessories Carry Case, Printer Cable . 26 Multimeter Industrial Grade 6.5 Digits For Laboratory Instruments Technical Specifications, Display Vfd Dot Matrix, Resolution 6½ Digits Or 5½ Digits, V Dc Ranges 100 Mv To 1000 V, Max.Resolutio Entage Of Measurement And 0.0005 Percentage Of Range, V Ac Ranges 100 Mv To 1000 V, Max.Resolution 100 Nv, Accuracy 0.06 Of .03 Percentage Of Range, Frequency 3 Hz To 300 Khz, Resistance 2X4 Wire Yes, Ranges 10 Ohm To 1 Gohm, Max.Resolution 10 Micro O Of Measurement And 0.001 Percentage Of Range, A Dc Ranges 100 Microa To 10 A, Max.Resolution 100 Pa, Accuracy 0.050 Percentage Of 27 Standard Tool Box For Instrument Mainte For Laboratory Instruments It Shall Comprise Of Multi Purpose Screw Drivers, Rachet Screw Drivers, Star Screwrndrivers, Spanners, Cutters, Pliers , Allen Keys -All Type, Nose Pliers, Roughand Smoothrnfiles, Slide And Pipe Wrench Etc. 28 Decade Resistance Box For Laboratory Instruments This Variable Resistance Device Shall Provide An Accurate Resistance Source For Calibration Of Rtd Elements And Receiver Devices. Accuracy Shall Be + / -0.05 Percentage Or Better. Resistance Range Shall Be 0-100 Kohm And Increments Shall Be 0.1 Ohm 29 Ferrul Printer With Cartridge For Laboratory Instruments 30 Adaptors Set, Material Ss304, Npt And Bsp For Laboratory Instruments 1 / 4 In Bsp Male X 1 / 8 In Bsp Parallel Female 10 Nos , 1 / 4 In Bsp Male X 1 / 8 In Npt Female 10 Nos, 1 / 4 In Bsp Male X 1 / 8 In Bsp Par Allel Male 10 Nos, 1 / 4 In Bsp Male X 1 / 8 In Npt Male 10 Nos, 1 / 4 In Bsp Male X 1 / 4 In Npt Female 10 Nos, 1 / 4 In Bsp Male X 1 / 4 In Npt Male 10 Nos, 1 / 4 In Bsp Male X 3 / 8 In Bsp Parallel Female 10 Nos , 1 / 4 In Bsp Male X 3 / 8 In Npt Female 10 Nos, 1 / 4 In Bsp Male X 3 / 8 In Bsp Parallel Male 10 Nos, 1 / 4 In Bsp Male X 3 / 8 In Npt Male 10 Nos, 1 / 4 In Bsp Male X 1 / 2 In Bsp Parallel Female 10 Nos, 1 / 4 In Bsp Male X 1 / 2 In Npt Female 10 Nos, 1 / 4 In Bsp Male X 1 / 2 In Bsp Parallel Male 10 Nos, 1 / 4 In Bsp Male X 1 / 2 In Npt Male 10 Nos. 31 Equal Tee For Laboratory Instruments Eequal Tee 1 / 8 In Bsp 10 Nos. Equal Tee 1 / 4 In Bsp 10 Nos Equal Tee 3 / 8 In Bsp 10 Nos 32 Unequal Tee For Laboratory Instruments Unequal Tee ¼ Inx 1 / 8 In X 1 / 8 In Bsp 10 Nos. Unequal Tee ½ In X 1 / 4 In X1 / 4 Inbsp 10 Nos. Unequal Tee 3 / 8 In Os 33 Tools Spanners, Slide Wrench 6 In For Laboratory Instruments Make- Taparia 34 Tools Spanners, Slide Wrench 9 In For Laboratory Instruments Make- Taparia 35 Tools Spanner, Slide Wrench 12 In For Laboratory Instruments Make- Taparia 36 Allen Keys , Normal Type, Inch Type For Laboratory Instruments Inch Type 1.5Mm, 2Mm, 2.5Mm, 3Mm, 4Mm, 5Mm, 6Mm, 8Mm, 10Mm , Make Taparia 37 Allen Keys, Normal Type, Metric Type For Laboratory Instruments Metric Type 1 / 16In, 5 / 64In, 3 / 32In, 1 / 8In, Rn5 / 32In, 3 / 16In, 7 / 32In, ¼in, 5 / 16In, 3 / 8In, Taparia Make 38 Allen Keys , Ball Type, Inch Type For Laboratory Instruments Inch Type 1.5Mm, 2Mm, 2.5Mm, 3Mm, Rn4mm, 5Mm, 6Mm, 8Mm, 10Mm , Taparia Make 39 Allen Keys , Ball Type, Metric Type For Laboratory Instruments Metric Type , 1 / 16In, 5 / 64In, 3 / 32In, 1 / 8In, 5 / 32In, 3 / 16In, 7 / 32In, ¼in, 5 / 16In, 3 / 8In 40 Screw Driver Set For Laboratory Instruments 1. Screw Driver Set;Flat Slot, 2. Screw Driver Set;Philips, 3. Screw Driver Set;Pozidriv Supadriv, 4. Screw Driver Set;Hex, 6. Squre Socket;Robertson, 7. Torx External; 6Lobes, Torx Internal; 6 Lobes, 9. One Way Removal Tool Make- Taparia 41 Screw Driver Bit Set For Laboratory Instruments

Key Value

Document Fees
Refer document
EMD
INR 99201.0 /-
Tender Value
INR 49.60 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail