Military Engineer Services-MES has published Repair/Maintenance Of Cooling Appliances At Ina Ezhimala. Submission Date for this Tender is 16-10-2019. Voltage Stabiliser Tenders in EZHIMALA Kerala. Bidders can get complete Tender details and download the document.
Name of Work: Repair/Maintenance of Cooling Appliances at INA Ezhimala. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | M&L for servicing of split type AC unit of any capacity/any make by removing dust with suitable method, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, servicing of condenser motor/ blower, by oiling, greasing, required welding/bracing, replacement of worn out rubber bushes of condensor motor, setting of grill alignment & knobs, Checking for any leakages, provision of thermocoal for air tightness, testing etc a complete as specified and directed.\nNote:- In case the contractor fails to rectify the defects within a week of intimation of the same, a penal recovery @ double the rate quoted for servicing will be affected in the RAR/ Final Bill. | 1 | 200 | Each Job |
2 | 2 | M&L for painting the outdoor unit of split AC of any capacity/any make and its stand by synthetic enamel spray paint as existing colour and writing MES No. complete as specified and directed. | 2 | 70 | Each Job |
3 | 3 | Removing the unserviceable blower motor from the Split AC 1.5/2 Ton unit and M&L for rewinding of blower motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush of suitable size, cleaning, greasing and refixing of motor, connecting up all including testing and refixing complete as specified and directed. | 3 | 20 | Each Job |
4 | 4 | Supply and fix in replacement blower motor 1/10 HP, 1350 RPM suitable for Split type AC 1.5/2 Ton out door unit single ended or double ended shaft as per existing one. complete as specified and directed.\nMake: AUE/ Marathon Electric or equivalent | 4 | 20 | Each Job |
5 | 5 | Removing the unserviceable compressor from Split type AC and supply and fix new compressor suitable for 1.5 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and complete as specified and directed.\nMake : Kirloskar/Mitsubishi/Bluestar/Tecumseh or equivalent as Approved by GE | 5 | 10 | Each Job |
6 | 6 | Removing the unserviceable compressor from Split type AC and supply and fix new compressor suitable for 2 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and complete as specified and directed.\nMake : Kirloskar/Mitsubishi/Bluestar/Tecumseh or equivalent | 6 | 15 | Each Job |
7 | 7 | S&F in replacemnt the copper piping (suction and discharge) and power cable including the thermal insulation complete as directed and specified.\n | 7 | 100 | RM |
8 | 8 | S&F drain pump suitable for casssette type Split AC 2 TR including taking down the defective drain pump complete as specified and directed.\nMake Bluestar/Kirloskar/Mitsubishi or equivalent as Approved by GE | 8 | 5 | Each |
9 | 9 | Supply and fix in repair indoor cooling coil made up of copper tubing and copper/aluminium cooling fins all as per sample and as suitable for 1.5/2 Ton capacity split type AC complete as specified and directed. | 9 | 6 | Each Job |
10 | 10 | Supply and fix in repair condenser coil made up of copper tubing and copper/aluminium cooling fins all as per sample and as suitable for 1.5/2 Ton capacity split type AC all as specified and directed by engr in charge.\n | 10 | 15 | Each |
11 | 11 | S&F in replacement room sensor all as per existing one and suitable for 1.5/2 Ton capacity split AC complete as specified and directed.\nMake : Bluestar/ LG/ Carrier or equivalent as Approved by GE | 11 | 25 | Each |
12 | 12 | S&F in replacement running capacitor 60 Mfd 440 V AC suitable for 1.5/2 Ton capacity AC complete as specified and directed.\nMake : KELTRON/BHEL/KEL/TESLA/SYSCAP or equivalent as Approved by GE\n | 12 | 50 | Each |
13 | 13 | S&F in replacement of capacitor 6 Mfd 440 Volts suitable for condensor motor of 1.5/2 Ton A/C capacity complete as specified and directed.\nMake : Renutral / Shriram/Usha/Keltron or equivalent as Approved by GE\n | 13 | 30 | Each |
14 | 14 | S&F in replacement coil sensor all as per existing one and suitable for 1.5/2 Ton capacity split AC complete as specified and directed.\nMake : Bluestar/ LG/ Carrier or equivalent as approved by GE\n | 14 | 20 | Each |
15 | 15 | S&F in replacement of condensor fan blade all as per existing one and suitable for 1.5/2 Ton capacity split AC complete as specified and directed.\nMake : Bluestar/ LG/ Carrier or equivalent as approved by GE | 15 | 10 | Each |
16 | 16 | S&F in replacement sheet metal enclosure , single pole neutral, with two pin and earth plug top and socket complete with one no of MCB SP, 20 A, 240 V complete as specified and directed. | 16 | 5 | Each |
17 | 17 | Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas charging as prescribed by manufacturer, leak testing & commissioning of Split type A/C of any type, any capacity, any make complete as specified and as directed. | 17 | 50 | Job |
18 | 18 | S&F in replacement of electronic circuit complete including controlling unit (ie Remote) all as per existing one and suitable for 1.5/2 Ton A/C complete as specified and directed by Engineer-in-Charge.\nMake:- Panasonic,Blue Star, Videocon, LG or equivalent as approved by GE. | 18 | 20 | Job |
19 | 19 | S&F in replacement of printed circuit board (PCB) complete including controlling unit (ie Remote) all as per existing one and suitable for 2 TR cassette type Split AC complete as specified and directed.\n Make Blue Star/LG/ Carrier or Equivalent as approved by GE. | 19 | 5 | Job |
20 | 20 | S&F in replacement of receiver PCB complete including the chords suitable for 1.5/2 TR Split AC all as per existing one complete as specified and directed by Engineer in Charge.\n Make Blue Star/LG/ Carrier or Equivalent as approved by GE. | 20 | 15 | Each |
21 | 21 | Removing the unserviceable condenser fan motor from the Water cooler of 40/120 Ltr capacity and M&L for rewinding of condenser fan motor of capacity 1/30 or 1/32 HP 1350 RPM single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing complete as specified and directed by Engineer-in-charge. | 21 | 10 | Job |
22 | 22 | Removing unserviceable condenser fan motor from the water cooler of any capacity and supply and fix in replacement new condenser fan motor 230 V, 50 HZ as per sample existing suitable for 40/120 Ltr capacity storage type water cooler complete as specified and directed by Engineer-in-charge. | 22 | 10 | Each |
23 | 23 | Removing the unserviceable compressor from water cooler and supply and fix new compressor suitable for 120 Ltr capacity of water cooler including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning of cooling coils necesary welding/ brazing and including required capillary tube complete as specified and as directed. | 23 | 5 | Job |
24 | 24 | S&F in replacement starting relay for 40/120 Ltr capacity water cooler including over load protector complete assembly complete as specified and directed.\nMake : KIRLOSKAR,INDFOSS /USHA/BLUESTAR or Equivalent as approved by GE. | 24 | 10 | Each |
25 | 25 | Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas charging as prescribed by manufacturer, leak testing & commissioning for water cooler 40/120 Ltr storage capacity, any type, any makecomplete as specified and directed. | 25 | 15 | Job |
26 | 26 | M&L for Servicing and cleaning of the water cooler 40/80/120 Ltr capacity by removing dust with suitable method, cleaning of water tank, inlet and outlets including leak proofing/ repairing of storage tank, necessary repairs to wiring of the water cooler unit (I.e) internal wiring connections to compressor, condenser motor etc., supply and replacement of damaged hinges, nuts, bolts, clamps, washers, screws, tightening of loose parts, servicing of condenser motor by oiling, greasing, required welding/bracing to the any part of the water cooler, repairs to chromium plated drain tray, replacement of worn out mounting rubber bushes of condenser motor/compressor, setting of thermostat, relay, knobs, checking for any leakages, scrap out rust and dust from body of water coole complete as specified and directed.\nNote:- In case the contractor fails to rectify the defects within a week of intimation of the same, a penal recovery @ double the rate quoted for servicing will be affected in the RAR/ Final Bill. | 26 | 30 | Job |
27 | 27 | M&L for Cutting, removing the old, rusted base angle iron frame and MS sheets not exc 0.30 M high of chasses cabinet and S&F angle iron and required MS sheet 2 mm thick suitable to the base of storage type water cooler body of 40/80/120 Ltr capacity all including cutting, welding, bending, shaping, grinding, drilling and making good, supply and fixing of nuts, bolts, washers as per requirement and Painting of Complete water cooler unit including compressor, condenser motor with one coat of red oxide primer and two coats of synthetic enamel paint as per existing colour complete as specified and directed. | 27 | 10 | Job |
28 | 28 | S&F in replacement of running capacitor 36 Mfd, suitable for 120 Ltr capacity water cooler complete as specified and directed.\nMake : USHA/SRIRAM/KELTRON/Syscap or equivalent as approved by GE. | 28 | 20 | Each |
29 | 29 | S&F in replacement of running capacitor 10 Mfd, suitable for 40 Ltr capacity water cooler complete as specified and directed.\nMake : USHA/SRIRAM/KELTRON/Syscap or equivalent as approved by GE. | 29 | 10 | Each |
30 | 30 | S&F in replacement chromium plated push/lifting cock, 15 mm, made up of brass and suitable for 40/80/120 Ltr capacity storage type water cooler as per existing sample complete as specified and directed. | 30 | 10 | Each |
31 | 31 | S&F in replacement of thermostat including knob, plate, screws suitable for 40/150 Ltr capacity water cooler complete as specified and specified.\n Make : USHA / Shriram / Blue star/Indfoss / Jhonson/Renutral or equivalent as approved by GE | 31 | 15 | Each |
32 | 32 | S&F in replacement of PVC drain pipe approx 1.5 Mtr Long of 25 mm dia for water cooler complete with clamp, screws etc complete to drain water from drain tray of water cooler as per existing sample complete as specified and directed. | 32 | 15 | Each |
33 | 33 | S&F in replacement of float valve with polythene PVC ball of 15 mm (1/2") bore size suitable for 40/120 Ltr capacity water coolers as per existing sample complete as specified and directed by Engineer-in-Charge.\nMake:Prayag or Equivalent as Approved by GE | 33 | 15 | Each |
34 | 34 | S&F in replacement prefilter of water purifier AG 200. complete as specified and directed.\nMake:Aquaguard or Equivalent as Approved by GE | 34 | 50 | Each |
35 | 35 | S&F in replacement of Carbon filter of water purifier complete as specified and directed.\nMake:Aquaguard or Equivalent as Approved by GE | 35 | 50 | Each |
36 | 36 | S&F in replacement solenoid valve for water purifier AG 200 complete as specified and directed.\nMake:Aquaguard or Equivalent as Approved by GE\n\n | 36 | 35 | Each |
37 | 37 | S&F in replacement of printed circuit board for water purifier AG 200 complete as specified and directed.\nMake:Aquaguard or Equivalent as Approved by GE | 37 | 15 | Each |
38 | 38 | S&F in replacement of UV lamp for water purifier AG 200 complete as specified and directed.\nMake:Aquaguard or Equivalent as Approved by GE | 38 | 25 | Each |
39 | 39 | S&F in replacement of UV sensor for water purifier AG 200 complete as specified and directed.\nMake:Aquaguard or Equivalent as Approved by GE | 39 | 20 | Each |
40 | 40 | S&F in replacement of UV+UF water purifier with purification capacity of minimum 60 ltr/hr complete with necessary arrangement for waste water after purification process complete as specified and directed by Engineer-in-Charge.\nNote:- Old Item will be taken to MES store | 40 | 4 | Each |
41 | 41 | S&F in replacement of flexible hose of purifier which connects prefilter to Water purifier incluidng necessary washers,screws etccomplete as specified and directed.\n | 41 | 30 | RM |
42 | 42 | S&F in replacement of toggle switch suitable of purifier. complete as specified and directed. | 42 | 10 | Each |
43 | 43 | Supply and fix in replacement of air drier bottle of best water doctor water cooler complete as specified and directed. | 43 | 10 | Each |
44 | 44 | M&L for servicing and repairs to voltage stabilizer of capacity 4KVA/5KVA of any type including checking the PCB control board,suitable 220/240V transformer, replacement of time delay relay, indicator lamps socket combination 5/15 Amps, plug tops, cut outs to rectify the defects complete as specified and directed.\nNote: Spares shall be measured and paid separately under appropriate items unless otherwise specified.\nNote:- In case the contractor fails to rectify the defects within a week of intimation of the same, a penal recovery @ double the rate quoted for servicing will be affected in the RAR/ Final Bill. | 44 | 20 | Each |
45 | 45 | Supply only PCB of voltage stabilizer of capacity 4 KVA including taking down the unserviceable one complete all as specified and directed.\n | 45 | 15 | Each |
46 | 46 | Supply only PCB of voltage stabilizer of capacity 5 KVA including taking down the unserviceable one complete as specified and directed. | 46 | 15 | Each |
47 | 47 | Supply only single phase 220/240 Volts transformer for 4/5 KVA voltage stabilizer complete as specified and directed. | 47 | 5 | Each |
48 | 48 | Supply & Fix in repair MCB 4 pole 415V, 10 kA, 63A capacity, C curve complete as specified and directed by Engineer-In-Charge. | 48 | 6 | Each |