Uttar Pradesh Housing And Development Board-UPAVP has published Supply Installation Testing Commissioning Of 02 Nos . Modular Operation Theatre , 1 No . Semi Modular Ot And Modular Icu And Sncu At 200 Bedded Maternity And Child Hospital Gomti Nagar Lucknow. Submission Date for this Tender is 10-10-2019. Modular Operation Theater Tenders in 200 Bedded Maternity and Child Hospital Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

21969362
Supply Installation Testing Commissioning Of 02 Nos . Modular Operation Theatre , 1 No . Semi Modular Ot And Modular Icu And Sncu At 200 Bedded Maternity And Child Hospital Gomti Nagar Lucknow
Open Tender
Indian
Uttar Pradesh
200 Bedded Maternity and Child Hospital Lucknow
10-10-2019

Tender Details

Supply Installation Testing Commissioning Of 02 Nos . Modular Operation Theatre , 1 No . Semi Modular Ot And Modular Icu And Sncu At 200 Bedded Maternity And Child Hospital Gomti Nagar Lucknow

Key Value

Document Fees
INR 8400 /-
EMD
INR 2000000.0 /-
Tender Value
INR 10 Crore /-

BOQ Items

Name of Work:S/I/T/C of 02 Nos. Modualar Operation Theatre, 1 No. Semi Modular OT and Modular ICU & SNCU at 200 Bedded Maternity & Child Hospital Gomti Nagar Lucknow.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 S/I/T/C of 2Nos. Modular OT BI01010001010000000000000515BI0100001112
2 1.01 WALLS PANEL (Mineral fiber Wall/ Glass Wall Panel)IMPORTED\nStainless Steel Powder coated with silveranti - microbiological coating. Monoblock free standing sandich wall construction in an axial strip grid design, wall thickness 50-60 mm, wallheight approx, 3.00 m insulation by high density mineral fiber.\nOne of the OT wall should be made of Glass wall Panel Imported The upper portion of wall panel is made by special aluminium profiles with 8mm thickness tempered glass,the total thickness of glass wall panel is 30mm; the lower portion of wall panel is made in 304SS thickness 1.0 mm for trolley impacts guard.\nAS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E.\nMake:-IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001113 165 Sqmtr
3 1.02 CEILING PANEL \nSupplying & Installation of Modular Operation theatre constructiion CEILING Panel with 0.6 mm thick EGP (Electrogalvanized steel Sheet) panels having a flame resistance to BS 1142 with proper supports . / System shall have CE mark as per MDD 93/42/EEC.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001114 90 Sqmtr
4 1.03 SUPORT STRUCTURE \nSupporting structure required for installing O.T wall and ceiling panel on the walls of the operating room.The FRAMEWORK should be made of upright ledgers and profiles entirely made of a galvanized steel sheet with a thickness of 1.5mm. They should folded structural steels with a suitable section for the loads. The structure components should be joined together by means of coupling systems in order to create a solid reticular frame, able to support different infill panels whose weight is up to 8 Kg/sq the “Z” upright forms the vertical part of the frame and should be equipped with proper drilling of 32mm ( height partial drilling) suitable for the panel coupling without suing screws between the prights and edges of the panel there is a suitable PVC adhesive seal with a thickness firm of 3mm to ensure air and dust sealing. At the lower end of the upright an adjustment foot should allow the easy leveling of the structure and, the necessary compression of the an charge between ceiling and floor. The ledgers should the elements that constitute the basic module of the structure. They should be inserted on the proper hooks by pressure between two uprights, Moreover some “U” profiles , to be placed in horizontal position on the upper and lower part of this structure, constitute its extension with a depth of 64mm together with the metal panels with a thickness of 18mm and the PVC adhesive seal. The structure can be provided with stiffening ledgers or profiles for sliding door fixing and other accessories according to needs. ).It shall be completed in all respect as per direction of I/E\nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001115 2 Sqmtr
5 1.04 Filling of Joints, Cavity (Anti-Bacterial Filler) \nFilling of all joints and cavaties with Metallic Epoxy filler and sanded flush to provide a jointless finish and self - sterlizing wall coating system to d d.f.t. of 300 microns with primer.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001116 255 Sqmtr
6 1.05 DOORS AND FRAMES (HERMETICALLY SEALED), \nSize (1500mmx2100mm) SENSOR OPERATED (PATIENT ENTRY)\nAutomatic with manual over-ride sliding doors having durability, ease of control, versatility for clean environments.\nTo maintain sterility and the correct air pressure in the room, all doors into and out of OT should be of this similar type. \nAutomation with sensors - foot operation and hand sensors \nOpening, closing and stay-open times should be programmable. Electrical motor drive should offer various control types such as energy saving feature (partial opening adjustable for distance and time); automatic closing (full opening, adjustable for time); sluice function and permanent opening. Lead protection on glass cutout is required. \nThe door and control should comply current IEE regulations and BS 7971 standard. Hermetically sealed Sliding Automatic Door shall be with Vision Panels 300 mm x 300 mm with double glazed panels , The door size is 1500mmx2100mm.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001117 2 Sqmtr
7 1.06 DOORS AND FRAMES (HERMETICALLY SEALED)\n Size (1000mmx2100mm), SENSOR OPERATED (DOCTOR ENTRY)\nAutomatic with manual over-ride sliding doors having durability, ease of control, versatility for clean environments.\nTo maintain sterility and the correct air pressure in the room, all doors into and out of OT should be of this similar type. \nAutomation with sensors - foot operation and hand sensors \nOpening, closing and stay-open times should be programmable. Electrical motor drive should offer various control types such as energy saving feature (partial opening adjustable for distance and time); automatic closing (full opening, adjustable for time); sluice function and permanent opening. Lead protection on glass cutout is required. \nThe door and control should comply current IEE regulations and BS 7971 standard. Hermetically sealed Sliding Automatic Door shall be with Vision Panels 300 mm x 300 mm with double glazed panels , The door size is 900-1000mmx2100mm.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001118 2 Nos.
8 1.07 STORAGE UNIT (1800mm x 1000mm x 230mm deep) \nThe storage unit made from 1.6mm of EGP steel. The doors of the storage cabinet should house vacuum insulated glass, these doors should be installed on the storage units with the help of fittings allowing an opening allowance of at least 1600. The storage unit should be divided in 2 equal parts and each part should have individual doors with locking system. Each part should be provided with glass racks as per user department. These should be completely detachable type. AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001119 2 Nos.
9 1.08 MOTORIZED VIEW WINDOW \nThe view window should be of Double insulated fixed glazing with not less than 5mm thick toughened safe glass. flush mounted with wall paneling. It should be aligned with present window and made of suitable size 1000mmx750mm. Maximum dimensions possible should be provided if asked for keeping in mind present civil setup. Motorised blinds should be provided which will be able to fully open and close such that full view from window is available or it can be closed fully. Also it should allow angulation of blinds view outside.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE\n\n\n\n\n\n\n BI01010001010000000000000515BI0100001120 1 Nos.
10 1.09 LED Peripheral Light cum Clean Room (OT) Luminaries \nLED based /digital blast peripheral lights (1’x2’) having high quality low wattage LED lighting system with highly spectacular anodized Aluminum reflectors Should give a total of 15000lx luminescence in operating area and 10000 lx in other peripheral areas with stepless, flickerless dimming control down to 5% level. There shall be two minimum independent circuits. They should be surface-mounted and recessed lights. Framed light cover should be made of highly-resistant and disinfectant - consistent laminated safety glass with visual systems against glare of the lamps and of the internal highly-specular reflectors, cumulative reflection coated, Body should consist of sheet steel with mechanical and electrical removable carrier equipment. Protection IP 65.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001121 16 Nos.
11 1.1 UNIDIRECTIONAL CEILING LAMINAR AIR FLOW \nPlanair Ceiling constructed out of extruded Aluminium sheet of size 2400 x 2400 mm having 6/8nos of HEPA Filters. Sufficient number of pre-filters to be provided that would maintain the efficiency of HEPA filters. The HEPA filters should have dust spot efficiency of 99.97% for 0.3 micron particles. Air diffuser made out of two layer of mono filament precision woven polyester for the plan air ceiling to give a "LAMINAR FLOW" of filtered air. Number of air changes should be such that Clean room classification can be maintained at Class 100, as per ISO 14644 System shall have CE mark as per MDD 93/42/EEC.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001122 2 Nos.
12 1.11 RETURN AIR GRILL \nThe openable and cleanable return-air exhaust Grill should be provided in the operation theater. Designed flow rate should not be less than 1000 m3/hr. Distribution of exhaust air volume between fluff strainers top should be 400 m3/hr and bottom 600 m3/hr. Fixed type exhaust air cabinet (non-openable) type should not be supplied. The air cabinets should have suction from top as well as from bottom.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001113 8 Nos.
13 1.12 CONDUCTIVE ANTISTATIC SEAMLESS FLOORING \nElectro Static Discharge (ESD) Control Flooring: Providing and fixing 2mm thick Conductive flooring with carbon backing total thickness 2.00 mm, polyurethane reinforced, scratch resistant, fire resistant, chemical resistant, slip resistant, resistant to fungal and bacterial growth. .AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001114 125 Nos.
14 1.13 SELF LEVELING COMPOUND\nCompound of 3 mm should have prolonged work ability, extra rapid hardening, compensated shrinkage, suitable for high-resistant adjustment from 2 to 4mm of irregular non-planer substrates before laying homogenous tiles with very low Total Volatile Organic Component (TVOC) emission and hypo-allergenic cements. The cement based adhesive should come with Shock Absorbing System (SAS) Technology, reactive-epoxide and polyurethane two component products, dispersed in water solution and solvent.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-INDIGENOUS MAKE\n BI01010001010000000000000515BI0100001115 130 Sqmtr
15 1.14 WRITING BOARD (List Board) Size: 1000 mm. x 700 mm. x 60 mm. deep\nWriting board should be made of ceramic having Magnetic properties and should be flushed to the wall of the operation room.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001116 2 Sqmtr
16 1.15 SURGEON CONTROL PANEL \nThe rest of the units are 2mm thick steel to BS10130: 1991, epoxy powder coated in brilliant white (50-60 microns) Front plate of Touch screen plates are 2mm thick, Powder coated Aluminum sheet l to BS1449, Part 2, 1983 grade 304S15. All types of special construction are available on request With the touch- sensitive monitor, operating and monitoring of tecnical equipment in medical location and other areas couldn't be simpler The OT Control Panel should be designed to cope with changing technology and equipment in operating environments. Control panel should be user friendly and ease of operating and maintaining purpose. (The touch screen typed Control panel also available as on option cast) . It should be mounted flush in the theatre wall. The Control Panel should comprise of following Six (6) services in addition to Instruction board, Communication interfaces etc.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:- IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001117 2 Nos.
17 1.16 PRESSURE RELIEF DAMPERS \nThe Pressure Relief Dampers are to be equipped with the theatre to prevent contamination of air from clean and dirty areas. The Dampers of suitable size should have AISI-304 Stainless Steel blades of thickness 1 mm each. The body should be epoxy powder coated as per standard BS colours.The statically and dynamically balanced Pressure Relief Damper should be properly placed. AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001118 2 Nos.
18 1.17 LED VIEWING SCREEN for X-Ray/ CT Scan\nTwin Plate CT view screen should be with electrical safety for high & low voltage system. It should be designed to provide flicker free luminance for the film viewing purpose. It should be installed flushed with the wall for hygiene and ease of cleaning.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001119 2 Nos.
19 1.18 DIRTY HATCH BOX\nIt should be of 610mmx610mmx610mmsize for disposal of dirty linen/waste to non-sterile store with Door open/close indication. Each Hatch should be equipped with two doors and the door should be operated electronically.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001120 2 Nos.
20 1.19 MULTI MOVEMENT MOTORIZED PENDANT \nEach Ceiling Suspended Pendant System should have\n1. Double Arm of about 1000 mm \n2. The swivel arms, carrying the supply column, should have the maximum degree of rotary motion in the horizontal plane and should be able to hold a weight of about 90 kg. \n3. The distribution column should be at least 600 to1000mm in height. \n4. Minimum clearance from finished floor to bottom of pendant should be about 1000 mm or as per site condition. \n5. Should have 2 platforms of about 75cms x 50cms x 40cms. The platforms should be adjustable along its vertical support and hence should be adaptable to the terminal units for which they are intended. The rack should be used to fit with trays both from front and back for optimal space utilization and balanced load distribution. \n6. Each platform should have weight bearing capacity of more than 15 Kg Each \n7. Should have dual IV rod stand with a capacity of about 10 Kg \n8. The following medical gas outlets should be provided on the back of the service head. \ni. O2 –2 Nos\nii. Nitrous Oxide –1 Nos\niii. Vacuum –2 Nos\niv. Compressed air supply –1 No \nv. Medical Air –2 No \n9. All Gas Outlets should come fitted from the factory \n10. 6 electrical sockets should be provided on the service head (3 on each side). These should be compatible to the Indian plugs.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-IMPORTED/GERMAN/ITALY\n BI01010001010000000000000515BI0100001121 4 Nos.
21 1.2 AIR HANDLING UNIT (AHU) With AC OUTER UNIT \nSupply of Air handling unit- constructed in EGP sheet and the system is designed to give 30 Air Changes per hour and to create sufficent Positive Pressure, Temprature is 20-22 degree centigrade with double sckin ,0.3 , 5, 10 micron filter , 4000cfm , three phase electrical conection require . with 11 TR coolong coil It should essentially have temperature and humidity control inside OT. \n The AHU for MOT OT may be ceiling suspended or Floor mounted by creating mezzanine floor with necessary arrangements of horizontal structural members, etc. This also involves modifications to the existing AHUs ducting that may foul with the proposed location and it shall be done by the contractors by following similar specifications. The AHU shall be compliant with the latest guidelines in NABH (National Accreditation Board for Hospitals and Healthcare Providers) Standards for super specialty O.T. or equivalent international standards. The AHU shall supply fresh and re-circulated air. The fresh air shall be minimum 20%.The system shall have provision to keep the blower on during non-functional hours, without temperature control. The AHU shall be comply as per EU Medical Device Directive 93/42/EEC.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E \nMake:-Waves/Edgetech/Zeco BI01010001010000000000000515BI0100001122 1 No.
22 1.21 DISTRIBUTION BOARD and INTERNAL WIRING, CONDUITING WITH FIXTURES INSIDE THE OPERATION THEATREConduits with fixtures inside the OT \nWiring with Low leakage current wires of FRLS wires as per requirements including providing and fixing of conduits and boxes, etc. Electrical Distribution Board along with all high voltage equipment should be installed in a separate enclosure. Electric Distribution Panel, UPS, Transformers, Mains, Relays, Circuit protective equipment, for all circuits of Operation theatre shall be installed in the remote cabinet. Wiring for 250 volts single phase and neutral 6/16 Amps switched socket outlet with 3 sq.mm and 2.5/4 sq.mm PVC insulated copper conductor 1100 volts stranded flexible wires should be concealed with conduit. AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-LEGRAND/ ABB/ PHILIPS/ HAVELLS BI01010001010000000000000515BI0100001117 2 Set
23 1.22 DOUBLE DOME LED OT LIGHTS\n"Ceiling mounted Dual Dome LED OT lights (imported and as per CE/ EN standard, with following features.\n- 160000 lux, \n- each Dome should have multiple steps dimming, \n- Focus\n- Light field dia - 180-320mm, \n- Colour temp. 4300k,\n- "Camera – ¼ type Super HAD CCD\n- Should have atleast 440000 Pixels\n- Should have atleast zoom 72x (18 x optical, 4 x digital), \n- Minimum Lighting should be 1.0 lux, \n- Signal/noise ratio should be 50db\n- Auto Shutter 1/1 to 1/10000 s, 22 levels"\n- Should have minimum 216 LEds, \n- Should have colour rendering Index Ra>93, \n- Should have safety glass, \n- Light emitting surface, \n- Medical grade monitor 21/24" \nAS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001118 2 Nos.
24 1.23 O.T SIGNAGE\nProviding and fixing of glowing signsge out side OT\nAS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E \nMake:-IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001119 2 Nos.
25 1.24 CENTRAL CONTROL ROOM (OT INTEGRATION SYSTEM)\nTrolley mounted audio/video recording & transmission system. Shift\nto the OT from when live transmission is to be displayed but could record only one operation at a time not all the 05 OTs.\nCommunication and Data archiving systems shall be placed on Mobile cart, Mobile cart may be moved OT to OT when streaming is required from OT, All the inputs connected with communication system can be streamed from OT, Output (HD-SDI) from HD OT light camera shall be provided on surgical pendant in each OT, Mobile cart may be moved near to surgical pendant in order to connect to Output of OT light camera, Surgical pendants in each OT shall be having Hospital LAN connection (Hospital Scope) Streaming shall be done using Hospital LAN network hence Multicast enabled LAN network with 3 layer switch will be required for uninterrupted streaming (Hospital Scope) Up to 5 computers (Including Auditorium) may be connected at the same time to get streaming from OT Streaming is one way Video and two way Audio.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001120 1 No.
26 1.25 SCRUB SINK SENSOR OPERATED \nProviding, fixing, testing and commissioning of Two Bay 1600mm\nSurgical Scrub Sink made up of 304Stainless Steel 1.6 mm thick sheet with electronic sensors and manual foot operation.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:- INDIGENOUS MAKE BI01010001010000000000000515BI0100001121 2 SET
27 1.26 DUCTING FOR IN SIDE O.T\naluminum ducting in side O.T 22/24 gause with all accessories .AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001122 1 No.
28 1.27 DUCTING FOR FRESH AIR OUTSIDE SIDE OT \nAluminum ducting in side O.T 22/24 gause with all accessories .AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001120 2 Set.
29 1.28 EXHAUST FRESH AIR UNIT \nhe treated air temperature will be constantly monitored and regulated by a dedicated digital controller. It is also possible to modulate the air fl ow by operating onto the fan speed selector to assure the best agreement between air renewal and noisy.AS PER SPECIFICATION ATTACHED (ANNEXURE-A).It shall be completed in all respect as per direction of I/E\nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001123 2 Lot
30 2 S/I/T/C of 1No. Semi Modular OT BI01010001010000000000000515BI0100001124
31 2.01 PRE-FABRICATED WALLS & CEILING PANEL \nSupplying & Installation of Pre fabricated Modular Operation theatre constructiion for Wall & Ceiling Panel with 40mm thick (Wall Panel) & 30mm thick (Ceiling Panel) PUF Sandwiched Double skin constructed with 0.8 mm thick (front side) & 0.6 mm thick (rear side) EGP (Electrogalvanized steel Sheet) panels having a flame resistance to BS 1142 with proper supports.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001125 90 Sqmtr
32 2.02 SUPORT STRUCTURE \nSupporting structure required for installing O.T wall and ceiling panel on the walls of the operating room should be galvanized steel profile. The inner surface frame should be constructed as per the load bearing calculations. The inner surface walls should be fixed to the brick wall with essential supports. There should be minimum possible cavity / gap in between the solid and steel walls.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001126 1 Lot.
33 2.03 Filling of Joints, Cavity and imported Antuibacterial paint (ANTIBACTERIAL COATING) \nFilling of all joints and cavaties with Metallic Epoxy filler and sanded flush to provide a jointless finish and then sprayed with a water based liquid plastic aspetic and self - sterlizing wall coating system to d d.f.t. of 300 microns with primer.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001117 90 Sqmtr
34 2.04 DOORS AND FRAMES (HERMETICALLY SEALED) Size- (1500mmx2100mm) SENSOR OPERATED \nAutomatic with manual over-ride sliding doors having durability, ease of control, versatility for clean environments.To maintain sterility and the correct air pressure in the room, all doors into and out of OT should be of this similar type. Automation with sensors - foot operation and hand sensors opening, closing and stay-open times should be programmable. Electrical motor drive should offer various control types such as energy saving feature (partial opening adjustable for distance and time); automatic closing (full opening, adjustable for time); sluice function and permanent opening. Lead protection on glass cutout is required. The door and control should comply current IEE regulations and BS 7971 standard / equivalent. Hermetically sealed Sliding Automatic Door shall be with Vision Panels 300 mm x 300 mm with double glazed panels, The door size is 1500mmx2100mm.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001118 1 Nos.
35 2.05 LED Peripheral Light cum Clean Room (OT) Luminaries\nLED based / digital blast peripheral lights (approx. 1’x2’) having high quality low wattage LED lighting system with highly spectacular anodized Aluminum / equivalent reflectors Should give a total of 15000lx luminescence in operating area and 10000 lx in other peripheral areas with stepless, flickerless dimming control down to 5% level. There shall be two minimum independent circuits. They should be surface-mounted and recessed lights. Framed light cover should be made of highly-resistant and disinfectant - consistent laminated safety glass with visual systems against glare of the lamps and of the internal highly-specular reflectors, cumulative reflection coated, Body should consist of sheet steel with mechanical and electrical removable carrier equipment. AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001119 6 Nos.
36 2.06 UNIDIRECTIONAL CEILING LAMINAR AIR FLOW \nPlanair Ceiling constructed out of extruded Aluminium sheet of size 2400 x 2100 mm having 6 / 8 nos of HEPA Filters. Sufficient number of pre-filters to be provided that would maintain the efficiency of HEPA filters. The HEPA filters should have dust spot efficiency of 99.97% for 0.3 micron particles. Air diffuser made out of two layer of mono filament precision woven polyester for the plan air ceiling to give a "LAMINAR FLOW" of filtered air. Number of air changes should be such that Clean room classification can be maintained at Class 100.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001120 1 Nos.
37 2.07 RETURN AIR GRILL \nThe openable and cleanable return-air exhaust Grill should be provided in the operation theater. Designed flow rate should not be less than 1000 m3/hr. Distribution of exhaust air volume between fluff strainers top should be 400 m3/hr and bottom 600 m3/hr. Fixed type exhaust air cabinet (non-openable) type should not be supplied. The air cabinets should have suction from top as well as from bottom. AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001121 4 Nos.
38 2.08 CONDUCTIVE ANTISTATIC SEAMLESS FLOORING \nElectro Static Discharge (ESD) Control Flooring: Providing and fixing 2mm thick Conductive flooring with carbon backing total thickness 2.00 mm, polyurethane reinforced, scratch resistant, fire resistant, chemical resistant, slip resistant, resistant to fungal and bacterial growth. AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001122 40 Sqmtr
39 2.09 SELF LEVELING COMPOUND \nCompound of 3 mm should have prolonged work ability, extra rapid hardening, compensated shrinkage, suitable for high-resistant adjustment from 2 to 4mm of irregular non-planer substrates before laying homogenous tiles with very low Total Volatile Organic Component (TVOC) emission and hypo-allergenic cements. The cement based adhesive should come with Shock Absorbing System (SAS) Technology, reactive-epoxide and polyurethane two component products, dispersed in water solution and solvent.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001116 40 Sqmtr
40 2.1 SURGEON CONTROL PANEL \nControl panel should have all the controls within the theatre and will be located on a membrane type panel mounted on the theatre wall. The time elapsed digital clock and real time digital clocks shall have high brightness characters, the medical gas alarm will indicate High and Low gas pressure for each gas service present in the operating theatre and will have an audible buzzer with mute facility. The medical gas alarms will be connected to local pressure switches located downstream of the last isolation valves. Each control panel should have display for Time elapse clock, Standard Clock, Temperature and Humidity, Clean room luminaries, Telephone, Medical Gas Alarms and HEPA filter status We should be able to change the temperature and humidity of the OT as per daily / case to case basis requirement. This AC temperature control unit should be available either on the control panel or as a separate panel (controler for AC supplier company responsbilty ) on the wall inside the operating room. AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001117 1 Nos.
41 2.11 LED VIEWING SCREEN for X-Ray / CT Scan\nTwin Plate CT view screen should be with electrical safety for high & low voltage system. It should be designed to provide flicker free luminance for the film viewing purpose. It should be installed flushed with the wall for hygiene and ease of cleaning. AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001118 1 Nos.
42 2.12 PENDANT FOR SURGEON & ANESTHESIA \nEach Ceiling Suspended Pendant System should be certified as per 93/42/EEC or USFDA and should have 1. Single Arm of about 1000 mm, having pneumatic / electro-magnetic brake 2. The swivel arms, carrying the supply column, should have the maximum degree of rotary motion in the horizontal plane and should be able to hold a weight of about 100 kg. 3. The distribution column should be at least 600 mm. in height.4. Minimum clearance from finished floor to bottom of pendant should be about 1000 mm or as per site condition. \n5. Should have 2 platforms of about 50 cms x 50 cms x 4 cms. The platforms should be adjustable along its vertical support and hence should be adaptable to the terminal units for which they are intended. The rack should be used to fit with trays both from front and back for optimal space utilization and balanced load distribution. \n6. Each platform should have weight bearing capacity of more than 15 Kg Each \n7. Should have dual IV rod stand with a capacity of about 10 Kg \n8. Povision for the following medical gas outlets should be provided on the back of the service head. \ni. O2 –2 Nos\nii. Nitrous Oxide –1 Nos\niii. Vacuum –2 Nos\niv. Compressed air supply –1 No \nv. Medical Air –2 No \n9. All Gas Outlets would be provided for fitment. \n10. 6 electrical sockets should be provided on the service head (3 on each side). These should be compatible to the Indian plugs. \nAS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001119 2 Nos.
43 2.13 DISTRIBUTION BOARD and INTERNAL WIRING, CONDUITING WITH FIXTURES INSIDE THE OPERATION THEATRE \nConduits with fixtures inside the OT Wiring with Low leakage current wires of FRLS wires as per requirements including providing and fixing of conduits and boxes, etc. Electrical Distribution Board along with all high voltage equipment should be installed in a separate enclosure. Electric Distribution Panel, UPS, Transformers, Mains, Relays, Circuit protective equipment, for all circuits of Operation theatre shall be installed in the remote cabinet. Wiring for 250 volts single phase and neutral 6/16 Amps switched socket outlet with 3 sq.mm and 2.5/4 sq.mm PVC insulated copper conductor 1100 volts stranded flexible wires should be concealed with conduit. AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:- LEGRAND/ ABB/ PHILIPS/ HAVELLS BI01010001010000000000000515BI0100001121 1 Lot
44 2.14 AIR HANDLING UNIT (AHU) With AC OUTER UNIT \nSupply of Air handling unit- constructed in EGP sheet and the system is designed to give 30 Air Changes per hour and to create sufficent Positive Pressure, Temprature is 20-22 degree centigrade with double sckin ,0.3 , 5, 10 micron filter, 3200 cfm , three phase electrical conection require . with 8TR coolong coil.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E Standard Approved Make.: Waves/Edgetech/Zeco BI01010001010000000000000515BI0100001122 1 set.
45 2.15 DUCTING FOR IN SIDE & OUTSIDE O.T\nAluminum ducting in side O.T 22/24 gause with all accessories AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001120 1 Lot
46 2.16 2 Bay SCRUB UNIT \nCompact surgical scrub sink is designed for use in OT complex providing Surgeons with a convenient sink for pre OT scrub up. The scrub station is made of high grade stainless steel and seamless welded construction, polished to a stain finish. The scrub sinks to be provided with a front access panel which includes infrared sensor (hands free operation) built-in with timer setting of 1 to 10 minutes depending on customer requirement.The system is fully assembled with Thermostatic mixing valve to maintain constant water temperature of cold and hot water, solenoid valve control, foot operated manual operation and soap dispenser.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001123 1 Nos.
47 3 S/I/T/C of Modular OBSTETRICS ICU(2 NOs.) , Modular SNCU (1 NO.) & Modular PEDIATRIC ICU (1 NO.) BI01010001010000000000000515BI0100001127
48 3.01 PRE-FABRICATED WALLS & CEILING PANEL IN ICU & CORRIDORS\nWall & Ceiling Panel with 40mm thick (Wall Panel) & 30mm thick (Ceiling Panel) PUF Sandwiched Double skin constructed with 0.8 mm thick (front side) & 0.6 mm thick (rear side) EGP (Electrogalvanized steel Sheet) panels having a flame resistance to BS 1142 with proper supports. AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE 920 Sqmtr
49 3.02 SUPPORT STRUCTOR IN ICU & CORRIDORS\nSupport structure for in side icu support to wall and ceiling panel (EGP material) with corridor.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001117 5 LOT
50 3.03 ANTISTATIC HOMOGENEOUS FLOORING IN ICU & CORRIDORS\nProviding and fixing 2mm thick antistatic homogeneous flooring with carbon backing total thickness 2mm thick PVC Vinyl flooring with scratch resistant, fire resistant, chemical resistant, slip resistant, resistant to fungal and bacterial growth. suitable for use in labs, OT’s etc. and conforming to static electrical charge 5x104 =Rt =106 ohms as per EN1081 and Electrical resistance 2.5x104 =Rt =106 ohms as per ANSI/ESD. AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001118 450 Sqmtr.
51 3.04 HVAC (AHU WITH OUTER UNIT) IN ICU & CORRIDORS\nProviding, fixing, supply, Installation commissioning of air handling unit AHU-(DX UNIT) constructed in EGP SHEET and The system is designed to give 15 TO 20 Air Changes Per Hour and to create sufficient Positive Pressure, Temp. range is 20-22 degree cent COIL CAPACITY 8TR 2no each AHU with fresh air system , centigrade with double sckin ,0.3, 5 to 10 micron filter ,8000cfm , with 16 TR. three phase electrical conection require . AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-Carrier / Blestar/ Voltas/Daikin BI01010001010000000000000515BI0100001119 5 No.
52 3.05 DUCTING IN SIDE & OUTSIDE IN ICU & CORRIDORS\nSupply of The internal ducting as per ISI-655 duly fabricated out of22/24 swg EGP sheet complete with flanges and accessories such as GI suspenders and GI supportscompletely sealed with Silicon sealant duly insulated with Aluminum foil Nitride rubber self adhesive typeinsulation.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001120 5 LOT
53 3.06 EXHAUST AIR GRILL IN ICU & CORRIDORS\nThe openable and cleanable return-air exhaust GRILL should be provided in the ICU AREA . Designed flow rate should not be less than 1000 m3/hr. Distribution of exhaust air .AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001121 48 No.
54 3.07 ELECTRICAL WIRING, INSIDE ICU & CORRIDORS\n Laying of PVC conduits, Modular Switches-sockets, Power and Light wiring including Earthing wire for all the lighting controls, Pendant and other equipment fixtures and fittings inside the ICU Wiring with low leakage current wires of FRLS wires as per requirements. Wiring for 250 volts single phase and neutral 6/16 Amps switched socket outlet with 3 sq.mm and 2.5 sq.mm PVC insulated copper conduct with cat6 cable for networking.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-LEGRAND/ ABB/ PHILIPS/ HAVELLS BI01010001010000000000000515BI0100001122 4 LOT
55 3.08 FILLING OF JOINTS, CAVITY AND IMPORTED ANTIBACTRIAL PAINT IN ICU & CORRIDORS\nFilling of all joints and cavaties with Metallic Epoxy filler and sanded flush to provide a jointless finish and then sprayed with a water based liquid plastic aspetic and self - sterlizing wall coating system to d d.f.t. of 300 microns with primer.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001116 920 sqmtr.
56 3.09 GENERAL LIGHT WITH DEMING IN ICU & CORRIDORS\nThe fluorescent lamps 54 W 16mm Ø- 1 nos / Non-hygroscopic high glow low power LED based /digital blast peripheral lights (1’x2’) having high quality low wattage LED lighting system with highly spectacular anodized Aluminum reflectors and optical antiglare system for adjustable light distribution. Luminaire cover made of highly resistant, disinfectant proof laminated safety glass with fine grained surface, glass pane with white powder coated steel frame. Luminaire body made of sheet steel, white, powder coated supplied ready for connection. AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001117 95 No.
57 3.1 HORIZONTAL WALL MOUNTED BED HEAD PANEL in SNCU \nThe modular medical Bed head panel should be fabricated of Aluminous die pressed in such a way to provide 100% safe and efficient means to deliver all the three gases as well as electrical to the patient/staff in intensive care conditions. To enclosed all piping, electrical wires, etc it should be fitted continuously on wall The design of modular should consist of aluminium section to meet the equirement of HTM 0201, NFPA and other international standard.There should be no sharp edges having smooth finish and without any visible screws etc.It should be have ability fix medical gas outlets, electrical sockets -. nurse’s call bell, IV fluid’s saline & Data socket. It should also have color code around the specific gas outlet and a slide rail for focus lamp. It should be polyester powder coating finish on all external surfaces and should be fitted with wall with the help of 8mm fasters at specific distance.1500mm Long Bedhead Panel It should be fixed in such a manner that it could be remove easily for servicing and\nrepair. It should be long and continuous to fix for any distance.\nProvision for accessories per bed: -\nOxygen outlet 2\nVacuum outlet 2\nCompressed air outlet 1\n Bracket for vacuum jar 1\nFocus light 1- optional\n15 Amp socket 2\n5 Amp socket 3\nIV saline 1- optional\nAS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001118 12 Nos.
58 3.11 Intravenous Track I.V Track In ICU \nIt should be made from heavy Duty Aluminum Intravenous track 'U' configuration size : 35mm (W) x 19.2mm(H) make of aluminum natural anodized to 15 microns complete with wall brackets with matching screws all strictly in accordance with the manufacturer's instruction 1 no. IV carrier to a set of IV support track complete with 5 points Telescopic Bottle Holder adjustable .AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001119 30 Nos.
59 3.12 Curtain Track partition . In ICU \nCubicle Curtain Track : It should be made from heavy Duty Aluminium cubicle track size 20mm wide x 30mm high, made of aluminium natural anodized to 15 microns complete with continuous PVC liner, nylon gliders and hooks, plastic end cap, connecting bridge, overlapping joint connector, wall brackets with matching screws to make up cubicle height to 2100mm clearance from floor level at 1000mm spacing and securely fixed to above slab.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE BI01010001010000000000000515BI0100001120 30 Nos.
60 3.13 DOORS AND FRAMES (HERMETICALLY SEALED) Double Leaf, Size (1800mmx2100mm) SENSOR OPERATED \nAutomatic with manual over-ride sliding doors having durability, ease of control, versatility for clean environments.To maintain sterility and the correct air pressure in the room, all doors into and out of OT should be of this similar type. Automation with 2 sensors - foot operation and hand sensors (magic switch) Opening, closing and stay-open times should be programmable. Electrical motor drive should offer various control types such as energy saving feature (partial opening adjustable for distance and time); automatic closing (full opening, adjustable for time); sluice function and permanent opening. Lead protection on glass cutout is required. The door and control should comply current IEE regulations and BS 7971 standard. Double leaf Hermetically sealed Sliding Automatic Door shall be with Vision Panels 300 mm x 300 mm with double glazed panels with size of 1800mmx2100mm.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE/ BI01010001010000000000000515BI0100001121 4 Nos.
61 3.14 Control Panel In ICU \nControl panel with matt aluminum finish should incorporate General Lighting Control with Switching ON/OF and dimming facility for Peripheral Light in the Cardiac Care Unit. AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE/ BI01010001010000000000000515BI0100001122 4 Nos.
62 3.15 Distribution Board In ICU & Corridors\nElectrical Distribution Board will have all high voltage equipment should be installed in a separate enclosure. The remote cabinet should house the operating lamp transformers, mains failure relays, electrical distribution equipment and circuit protection equipment for all circuits within the operating theatre. All internal wiring should terminate in connectors with screw and clamp spring connections of the Clip-on type mounted, on a DIN rail. Individual fuses or miniature circuit breakers should protect all internal circuits. Should have CE marking. CE certificate must be submitted.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:- LEGRAND/ ABB/ PHILIPS/ HAVELLS BI01010001010000000000000515BI0100001120 5 Nos.
63 3.16 ICU PENDANT\nProviding, fixing, testing and commissioning of The pendant should be high degree of flexibility due to expandability in terms of equipment options. The pneumatic break should be used to secure system and prevent any accidental movement of the ceiling pendant. Variable placement of shelves to ensure adaptability of various requirements in OT Integration ICU equipment with built-in life system Double arm pendant should be installed depending on the given conditions and the individual requirements in the operating theatre. A ceiling supply system with two-part arm can not only move along a circular curve and rotate on its own axis, but may also be flexibly positioned at any point of a circular area. Configuration Rated for maximum 150 kg load,as per specifications CE/FDA/UL.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-IMPORTED/GERMAN/ITALY BI01010001010000000000000515BI0100001123 18 Nos.
64 3.17 VIEW WINDOW with Motorised Blinds In ICU \nThe view window should be of Double insulated fixed glazing with not less than 5mm thick toughened safe glass. flush mounted with wall paneling. It should be aligned with present window and made of suitable size 1000mmx750mm. Maximum dimensions possible should be provided if asked for keeping in mind present civil setup. Motorised blinds should be provided which will be able to fully open and close such that full view from window is available or it can be closed fully. Also it should allow angulation of blinds view outside.AS PER SPECIFICATION ATTACHED (ANNEXURE-B).It shall be completed in all respect as per direction of I/E \nMake:-INDIGENOUS MAKE/ BI01010001010000000000000515BI0100001121 6 Nos.