Educational and Research Institute Government Departments Closing in 0 days TDR #21926328

Providing And Commissioning 2 Nos. Of Passenger Lift In Naac Office And Reflective Pool

Issued by Government Departments · Bangalore, Karnataka
Tender Value
50.82 Lakhs
Estimated cost
Bid Submission
16 Oct 2019
0 days left
EMD
1.02 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bangalore → Karnataka
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Providing And Commissioning 2 Nos. Of Passenger Lift In Naac Office And Reflective Pool

BOQ

Name of Work: < Providing and commissioning 2 Nos of Passenger Lift in NAAC office and Reflective Pool>
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.\nFor thickness of tiles 10 mm to 25 mmitem 122.97Sqm
22Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.item 26.87Cum
33Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.item 36.87Cum
44Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.\nNominal concrete 1:3:6 or richer mix (i/c equivalent design mix)item 44.74Sqm
55Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.item 510.96Sqm
66Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge.item 6211.62Kgs
77Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.item 72.9Cum
88Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.item 821.47Cum
99Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.\nNote : 1) Excess/less cement used than specified in this item is payable/\nrecoverable separately.M-10 grade plain cement concrete (cement content considered @ 220 kg/cum)item 91.03Cum
1010Steel reinforcement for R.C.C. work for lift pit and form finish lift wall including straightening, cutting,bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500 D or more.item 102.77MT
1111Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns, etc. for mass concreteitem 1151.46Sqm
1212Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. Suspended floors, roofs, landings, balconies and access platform.item 1244.44Sqm
1313Suspended floors, roofs, landings, balconies and access platformitem 1334.54Sqm
1414Stairs, (excluding landings) except spiral-staircasesitem 144.59375Sqm
1515Providing and laying in position cement concrete of specified grade for the lift pit excluding the cost of centering and shuttering - All work up to plinth level :\n1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)item 1514.33Cum
1616Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).item 168.79Cum
1717Providing and constructing precast concrete solid blocks with compressive strength not less than 35 kg/Sqm with cement mortar 1:4 (1 cement : 4 coarse sand) masonry (quion, Jamb, closer blocks) with solid concrete blocks of size 40x20x20 cms conforming to IS : 2185/Part I - 2005 including cost of materials, labour charges, scaffolding , curing complete as per the directions of engineer-in-charge. Note : For the purpose of measuring up and making payment of this item of work, the mode of measurement shall be as follows : The length and height of the wall shall be measured correct to a cm. The area shall be calculated in Sqm.item 1732.01Sqm
1818Providing and constructing precast concrete solid blocks with compressive strength not less than 35 kg/Sqm with cement mortar 1:4 (1 cement : 4 coarse sand) masonry (quion, Jamb, closer blocks) with solid concrete blocks of size 40x20x10 cms conforming to IS : 2185/Part I - 2005 in susperstructure including cost of materials, labour charges, scaffolding , curing complete as per the directions of engineer-in-charge. Note : For the purpose of measuring up and making payment of this item of work, the mode of measurement shall be as follows : The length and height of the wall shall be measured correct to a cm. The area shall be calculated in Sqm.item 1821.18Sqm
1919Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.item 194785.32Kg
2020Providing and applying integral crystalline dry shake of hydrophilic in nature for waterproofing treatment to the fish pond etc. sprinkled @ 0.60kg per Sqm or higher as recommended by the manufacturer's specification over the lean concrete of above cited structures. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 85%, compared control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline dry-shake shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-incharge. The product performance shall carry guarantee for 10 years against any leakage and same should be submitted by vendor in bond paper.item 2059.44Sqm
2121Providing and applying integral crystalline slurry of hydrophilic in nature for\nwaterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.\nFor horizontal surface one coat @1.10 kg per sqm.item 2166.76Sqm
2222Preparing and plastering to internal surfaces of walls, beams above walls, fins, columns in CM 1:6 12 to 20mm thick inclusive of lime rendering etc., complete including scaffolding , finishing, curing etc., complete.item 22189.88Sqm
2323Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.item 23106.21Sqm
2424Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :item 24106.21Sqm
2525Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and\nmanufacture, including applying additional coats wherever required, to achieveeven shade and colour.item 25106.21Sqm
2626Supply, testing and commissioning of under water light fixtures of the approved make with accessories complete as per instruction of engineer-in-charge Rate shall include necessary mounting bracket, suspension chains etc.,item 262L.S
2727Providing and fixing Ist quality Mosaic Blue glass tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade.item 2731.63Sqm
2828Providing and laying Matt Finish Vitrified tiles in floor with different sizes (thicknessto be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 300x300 mm - Make Kajaria , Somany Or Equalent .item 2821.76Sqm
2929Supplying, installing, testing and commissioning approved make submerssible Water body pump made of SS. The quoted rate shall also include providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter.( Water Body pump)item 291Nos
3030Providing and fixing Chlorinated Poli Vinyl Chloride (CPVC) pipes conforming to IS 15778 having terminal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this including fixing the pipe with clamp at 1.00mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. 25mm diaitem 308.4Rmt
313150 mm diaitem 3121Rmt
3232Supplying and fixing approved make UPVC multi-inlet floor trap of the approved make with 50mm dia outlet and C.P. cover on top etc., complete with cement concrete support alround the floor trap as per instruction of engineer in chargeitem 3224.5Nos
3333Supply of Green Wall modules of Size 1000mm x 500mm fabricated with Coir hard board of 6mm thickness with a filling cavity of 30 mm of sufficient quantity to cover the required area. Modules to be filled with Super Absorbent Polymer Substrate. Face of the Module to have 88 mechanically drilled holes of 35 mm Dia. Plants to be pre-selected as per site conditions, planted on the individual modules and nurtured for a period of 45-90 days. Back of the module to be fitted with 4 Aluminum Hooks sufficient to install on 35mm GI channels fitted onto the wall or to be installed on a pre-fabricated MS frame. 16 mm irrigation pipes fitted with drippers and automated using a battery based timer to be installed for the purpose of irrigation. Basic PVC Drain to be fitted at the bottom for collection of excess water if any.item 3312.6Sqm
3434Providing and laying polished white coloured pebbles of sizes 10-30mm in 2 layers over the specified area as per the design and direction of Engineer/Architect in Charge.item 342.84Sqm
3535Providing and laying red soil for the planter box. The quoted rate shall include all the lead, lift, stacking , transportation and spreading the soil in the planter box as per direction of Engineer In Chargeitem 352.61Cum
3636Providing and laying 20mm thick granite of approved make with half nosing and grouting complete as per direction of Engineer in charge on the top surface of the planter box.\nitem 3630.55Rmt
3737Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.item 37145.74Sqm
3838Supply, Testing and Installation of gearless and machine room less elevator of the approved make (Schindler 3300IN) with a 8 passenger capacity (544 Kg) and 2 stops with lockable storage room of 250 sq.ft and stilt area under the roof of 200sq.ft. The car size is 1100 (W) x 1300 (D) x 2135 (H) mm with Glass doors. The car door which is Center opening is glass with stainless steel frame with only one access side. The Clear inside shaft dimensions are 1800mm (W) x 1700mm (D). The car has natural granite flooring, SS leather finish with variable voltage variable frequency controlled drive system and full collective control type controller. The speed of travel is 1.00 m/s with a travel height upto 7000mm. The door dimensions are 800x2000mm with center opening. The landing doors are 2 hours fire rated, fully automatic in glass with stainless steel frame. The elevator comprises of automatic rescue device, overload notification, pre announcing arrows for collective controls, position indicator, light curtain protection on doors, car and landing operating panel in touch sensitive, stylish, resistant glass panel, door open/close and alarm buttons, visual and acoustic confirmation of call, call acceptance (visual), battery operated alarm bell, CCTV, emergency light, car reservation service with parking, auto car lift off, out of service mode, auto fan off, protection against power fluctuations, intercom between car and lobby, Hand rail and mirror on rear side car wall,touch pannel and all the necessary fittings as per the detail drawings as per the direction/instructions/appproval of the Engineer/Architect in charge.The quoted rate shall also include comprehensive maintenance for 1 year after installation.The quoted rate inclusive of approval/clearnace from statutory bodies. Buttons of lift to be brail compatibleitem 381Nos
3939Item same as sl.no 38 but the make is Otis . The model and requirement should be same as schindler make 3300IN. Quote Rate onlyitem 391Nos
4040Supply, Testing and Installation of gearless and machine room less elevator of the approved make (Schindler 3300IN) with a 8 passenger capacity (544 Kg) and 3 stops with lockable storage room of 250 sq.ft and stilt area under the roof of 200sq.ft. The car size is 1000 (W) x 950 (D) x 2135 (H) mm with stainless steel hairline finish Walls. The car door which is Telescopic left opening is of stainless steel hairline finish with only one side access. The Clear inside shaft dimensions are 1550mm (W) x 1330mm (D). The car has approved Granite flooring and powder coated deco ceiling, it has leather SS finish car operating panel with dot matrix display in glass, with variable voltage variable frequency controlled drive system and full collective control type controller. The speed of travel is 1.00 m/s with a travel height of 8000mm. The door dimensions are 750x2000mm. The landing doors are fully automatic in glass with stainless steel finish. The elevator comprises of automatic rescue device, overload notification, pre announcing arrows for collective controls, position indicator, door open/close and alarm buttons, Auto fan off, Call Acceptance (Visual), Automatic Evacuation to nearest floor (ARD) as standard, Hand rail and mirror on rear side car wall, CCTV and all the necessary fittings as per the detail drawings as per the direction/instructions/appproval of the Engineer/Architect in charge.The quoted rate shall also include comprehensive maintenance for 1 year after installation.The quoted rate inclusive of approval/clearnace from statutory bodies. The Buttons of the lift to be Brail compatibleitem 401Nos
4141Item same as sl.no 40 but the make is Otis . The model and requirement should be same as schindler make 3300IN. Quote rate onlyitem 411No.
4242Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).item 4284.16Kg
4343Supplying and Fixing smoke windows of approved make with louvers in powder coated Aluminium frame of minimum thickness 50 microns and exhaust provision over a 200x200mm frame with necessary screws etc complete as per the direction of architect/engineer in charge.item 431.13Sqm
4444Supplying and Erecting scaffolding - cup and lock system of size 1200x1200mm with breakings at every 1500mm height and base plate for the 4 verticals for the required height as per drawings and instruction of the Engineer in charge. (Height of scaffolding = 3000mm each)item 44166.47Sqm
4545Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab upto 0.50 sqmitem 451.51Sqm
4646Area of slab over 0.50 sqmitem 463.91Sqm
4747Lift Panels : Supplying, installing, testing and commissioning of following capacity TPN tap off box / plug-in box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing overhead bus bar system complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.Approval of GA dwgs. shall be obtained from Consultants for each panel before fabrication.item 472Each
4848The Panel shall be inclusive of all fixtures like 1 no 63amps 4 pole ELCB , with all interconnected wirings , complete as per the lift vendor details/ instructions provided by the Engineer-In-charge.item 482Set
4949Earthing Pit :Earthing with G.I earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.item 494Set
5050Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Aitem 502Each
515163 Aitem 512Each
5252Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Poleitem 524Each
5353Double Poleitem 532each
5454Point wiring :Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wireitem 5455Meter
55554 X 6 sq. mm + 2 X 6 sq. mm earth wireitem 55175Meter
56562 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wireitem 5690Meter
5757Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.item 578Each
58581 Number Bulk head fittings with wire guard mesh & 1 x 18 w CFL lamp & necessary fixing accessories.item 588Each
5959Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cableitem 5975Meter
6060Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.item 60132Meter

AI Tender Summary

OUR REF NO 21926328
AUTHORITY Government Departments
TENDER VALUE 50.82 Lakhs
LAST DATE 16-10-2019
Authority
Authority Name National Assessment And Accreditation Council
Work Description Providing And Commissioning 2 Nos. Of Passenger Lift In Naac Office And Reflective Pool
Basic Detail
Tender No NAAC/Admin/Works/2019-01
Bidding Type Tender
Location
City Bangalore
State Karnataka
Key Dates
Publish Date 24 Sep 2019
Submission Date 16 Oct 2019
Open Date 18 Oct 2019
Finance
Tender Value 50.82 Lakhs
Tender Fee 1000
EMD 1.02 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
C1EDFF28-503F-46A1-99EA-4C42264DBBF5.html
BOQ_529484.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 24, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 16, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 18, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

C1EDFF28-503F-46A1-99EA-4C42264DBBF5.html

xls

BOQ_529484.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender