Repair And Maintenance To Water Supply Installations , Cleaning Of Ug Sumps , Oh Tanks , Service Tanks And Connected Works At Afs Hakimpet Under Ge ( Af ) Hakimpet
Tender Value
20 Lakhs
Estimated cost
Bid Submission
14 Oct 2019
0 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hakimpet → Telangana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair And Maintenance To Water Supply Installations , Cleaning Of Ug Sumps , Oh Tanks , Service Tanks And Connected Works At Afs Hakimpet Under Ge ( Af ) Hakimpet
BOQ
| NAME OF WORK: REPAIR AND MAINTENANCE TO WATER SUPPLY INSTALLATIONS, CLEANING OF UG SUMPS, OH TANKS, SERVICE TANKS AND CONNECTED WORKS AT AFS HAKIMPET UNDER GE(AF) HAKIMPET. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Repair of valve chamber including necessary PCC and plastering , fixing of hold fast hinged and angle frame with MS sheet cover 3mm thick of valve pit of size 750mm x750mm x 750mm, complete all as specified and directed. | 8 | Each Job | |
| 2 | 2 | Demolition of valve chamber of any description and size and removing demolished material to a distance exceeding 1.5 Km and not exeeding 5 Km and depositing where directed. | 8 | Cum | |
| 3 | 3 | M&L for construction of valve chamber of following internal sizes with 100 mm thick PCC (1:4:8 ) type D-2 for foundation , brick walls built in cement mortor (1:4 ) , PCC 1:2:4 type B1 for coping , rendering in cement mortor 1:4 , 15 mm thick both internally and externally upto 15 cm below GL including provision of MS sheet cover using angle iron 40 x40 x6 mm as a frame embedded in concrete and 3 mm thick MS sheet as in cover with necessary locking arrangements duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including necessary earth work and excavation, complete all as specified and directed. | |||
| 4 | 3.01 | 600x600x600 mm | 4 | Each Job | |
| 5 | 3.02 | 750mm x 750mm x 750mm | 2 | Each Job | |
| 6 | 3.03 | 1050mm x 1050mm x 1050mm | 4 | Each Job | |
| 7 | 4 | M&L for cement concrete in foundations, filling and mass concrete type D2 1:4:8 using 40 mm grade stone aggregate, complete all as specified and directed. | 4 | Cum | |
| 8 | 5 | M&L for cement concrete in copping type B1 1:2:4 using 20 mm graded stone aggregate, complete all as specified and directed. | 4 | Cum | |
| 9 | 6 | M&L for rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces finished even and smooth (with out using extra cement), complete all as specified and directed. | 2 | Sqm | |
| 10 | 7 | Lifting RCC cover/slabs/PVC cover of RCC over head water service tank/PVC tanks and taking out float valve carefully, setting aside, cleaning with caustic soda solution and removing all dirt and dust etc, from the internal portion of tanks including from mouths of circulating inlet/outlet pipes and over flow pipes complete and writing with black/white paint on external side of the tank with letters of 4 cm height (as tank cleaned on, month and year), properly refixing the float valve and properly placing of RCC/PVC covers back in position of the following capacity of tanks, complete all as directed. | |||
| 11 | 7.01 | Capacity of tank exceeding 250 Ltrs and not exceeding 500 Ltrs | 1500 | Each | |
| 12 | 7.02 | Capacity of tank exceeding 500 Ltrs and not exceeding 1000 Ltrs | 500 | Each | |
| 13 | 7.03 | Capacity of tank exceeding 1000 ltrs and not exceeding 5000 ltrs | 40 | Each | |
| 14 | 7.04 | Note : Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scale and the same shall be reconnected after cleaning the OHT and the quoted rate is deemed to include for this provision.If any complaint will be received from occupant \"No water supply\" etc the quoted rate is deemed to include for the provision, complete all as specified and directed. | |||
| 15 | 8 | Cleaning internal portion of stone masonry/RCC over head reservoirs and removing fine sand/silt deposited inside the over head reservoirs with the help of wire brushes and removing any fungus formation inside the tank, removing the waste as directed and applying caustic soda solution and one coat of lime wash to internal walls and one coat of snocem on external walls including writing with one coat of synthetic enamel paint black/white colour for inlet/outlet CI/GI pipes & marking flow of water on pipes and painting/writing letters on external walls as (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank, complete all as directed for the following capacity tanks:- | |||
| 16 | 8.01 | 10,000 Glns capacity.(Officers Colony) | 1 | Job | |
| 17 | 8.02 | 15,000 Glns capacity (Officers Colony) | 1 | Job | |
| 18 | 8.03 | 20,000 Glns capacity (CPH) | 1 | Job | |
| 19 | 8.04 | 25,000 Glns capacity.(NP Area) | 1 | Job | |
| 20 | 8.05 | 36,000 Glns capacity.( In two compartments at CPH) | 1 | Job | |
| 21 | 8.06 | 50,000 Glns capacity.( 03 Nos at CPH & 01 No at Officers Colony) | 4 | Job | |
| 22 | 9 | Cleaning internal portion of stone masonry/RCC under ground/ Semi under ground sumps removing fine sand/silt deposited inside the sumps with the help of wire brushes and removing any fungus formation inside the tank, removing the waste as directed and applying caustic soda solution and one coat of lime wash to internal walls and one coat of snocem on expossed external walls including writing with one coat of synthetic enamel paint black/white colour for inlet/outlet CI/GI pipes & marking flow of water on pipes and painting/writing letters on external walls as (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank complete all as directed for the following capacity tanks:- | |||
| 23 | 9.01 | 30,000 Glns capacity under ground sump.(Officer Colony) | 2 | Each | |
| 24 | 9.02 | 25,000 Glns capacity under ground sump.(NP Area) | 2 | Each | |
| 25 | 9.03 | 1, 00,000 Glns capacity under ground sump.(CPH) | 1 | Each | |
| 26 | 9.04 | 1.2, 0000 Glns capacity under ground sump.(CPH) | 1 | Each | |
| 27 | 9.05 | 2,00000 Glns capacity under ground sump.(CPH) | 1 | Each | |
| 28 | 9.06 | 10,000 Glns capacity under ground sump (CPH) | 1 | Each | |
| 29 | 9.07 | 5,000 Glns capacity under ground sump (infront of station HQ, 250 SU & 27 End) | 3 | Each | |
| 30 | 10 | Supply and fix mild steel wire cloth 0.48 mm nominal dia of wire and average width of aperture 1.80 mm and fixed with tinned tacks or galvanized wire staples as to existing CI flanged tail pieces or on wooden frames including removing unserviceable wire cloth, complete all as specified and directed. | 5 | Sqm | |
| 31 | 11 | Supply and fix PVC Cover lead to match the existing PVC water tank for following capacity, complete all as specified and directed. | |||
| 32 | 11.01 | 250 ltrs capacity tank | 100 | Each | |
| 33 | 11.02 | 500 ltrs capacity tank | 300 | Each | |
| 34 | 11.03 | 1000 ltrs capacity tank | 50 | Each | |
| 35 | 12 | M & L for taking out old corroded unserviceable MS sheet cover, frame etc from top of the roof of the under ground sump with MS channel base square / circular type , of size and shape as per size requirement including providing of new cover made out of 14 SWG MS sheet cover with 50 cm X 50 cm X 6 mm angle iron base frame including painting with two coats synthetic enamel black paint over acoat of red oxide primer complete with locking arrangements and locks, complete all as specified and directed. | 6 | Each | |
| 36 | 13 | M&L for applying two coats of white wash on walls, roof and base (inside) of UG sump and OHT including preparation of surfaces, complete all as specified and directed. | 500 | Sqm | |
| 37 | 14 | M&L for preparation of old painted steel surfaces of pipe of any description n. Exc 10 cm width or girth and painting with anti-corrosive paint of approved colour, complete all as specified and directed. | 3 | Sqm | |
| 38 | 15 | M&L for structural steel work in stairs (framed) including stingers, treaders, landing ballaster, hand rails etc. Including cleats, brackets etc complete including dismantling all as specified and directed | 150 | Kg | |
| 39 | 16 | M&L for distempering external walls and roofs with two coat of cement paint including preparation of surfaces. Complete all as specified and directed. | 1500 | Sqm | |
| 40 | 17 | M&L for rolled mild steel plates ( plain or chequered) channels square cut or notched ( ordinary and counter sunk) as in valve chamber cover or pipe line duct covers including taking down existing covers, complete all as specified and directed. | 300 | Kg | |
| 41 | 18 | Supply and replace dry type pressure gauge 0 - 5 Kg/cm2 having dial size 100mm dia in stainless steel enclosure bottom connection type, complete all as specified and directed. | 5 | Each | |
| 42 | 19 | Supply and erection of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 meters long) including painting of pole with black bituminous paint internally and up to 1.5m from bottom level externally and two coats of aluminium paint over a coat of red oxide primer externally including taking down existing steel tubular pole, complete all as specified and directed. | 12 | Each | |
| 43 | 20 | Supply and fix LED street light fitting 45 watts with built in electronic driver and LEDs housed in pressure die cast aluminium housing with toughened glass and silicon gasket for IP66 degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on steel tubular round poles with suitable MS clamps(02Nos) made up of 40mmx5mm MS flat, nuts, bolts and washers including taking down existing street light fitting of any description, complete all as specified and directed. | 12 | Each | |
| 44 | 21 | Supply and fix Post Top LED light fitting 25 watts with electronic driver and LED lamps housed in die cast aluminium housing having IP65 degree of protection including taking down existing post top lantern of any description, complete all as specified and directed. | 4 | Each | |
| 45 | 22 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out in hard / dense soil for laying cables / pipes etc, complete all as specified and directed. | 100 | Cum | |
| 46 | 23 | All as per item No.22 above but depth exceeding 1.5 m but not exceeding 3 m, complete all as specified and directed. | 2 | Cum | |
| 47 | 24 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed. | 65 | Cum | |
| 48 | 25 | Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed. | 77 | Cum | |
| 49 | 26 | Supply and spread clean dry sand in trenches 8 cm below the cable and 15 cm above the cable, levelled and punned down to 18cm for cushioning of cable, complete all as specified and as directed. Note: Punned down thickness shall only be measured for the purpose of payment. | 25 | Cum | |
| 50 | 27 | Supply and laying bricks of sub class 'B' old burnt/fly ash/ cement bricks for cable protection, complete all as specified and directed. | 3500 | Each | |
| 51 | 28 | Supply, laying & testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade conforming to IS : 7098 Part - I of following sizes, including taking down existing cable, complete all as specified and directed.:- | |||
| 52 | 28.01 | 4 Core, 16 Sqmm | 200 | RM | |
| 53 | 28.02 | 2 Core, 10 Sqmm | 300 | RM | |
| 54 | 29 | M&L for 40 mm bore galvanized iron pipe, light grade, with all fittings, complete laid in road crossings/on poles/walls/in floors for cable protection, complete all as specified and directed. | 50 | Each | |
| 55 | 30 | Supply and fix LED flood light fitting 100 Watt with electronic driver and LED lamp, Die cast aluminium housing IP-66 protection enclosure including taking down existing flood light of any description, complete all as specified and directed. | 15 | Each | |
| 56 | 31 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 150 sqmm,Indoor/Outdoor type, complete all as specified and directed.\n | 2 | Each | |
| 57 | 32 | Supply, laying & testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade conforming to IS : 7098 Part - I of following sizes, including taking down existing cable, complete all as specified and directed:- | |||
| 58 | 32.01 | MCCB 63 amps four pole fixed type, Breaking capacity 25 KA, 415 volt AC, 50 HZ confirms to IEC 60947II / IS 13947II. Make - Standard/Legrand/L&T | 3 | Each | |
| 59 | 32.02 | MCCB 100 ams four pole,fixed thermal and fixed magnetic setting, Breaking capacity 25 KA, 415 volt AC, 50 HZ confirms to IEC 60947II / IS 13947II. Make - Standard/Legrand/L&T | 2 | Each | |
| 60 | 32.03 | Voltmeter 0 to 500 Volts make - Meco, AE, L&T | 5 | Each | |
| 61 | 32.04 | Ammeter 0-50 Amps with CTS and selector switch Meco, AE, L&T | 5 | Each | |
| 62 | 32.05 | Indicating lamp (set of 3 ) Make - HPL/Siemens or equivalent | 5 | Set | |
| 63 | 32.06 | Automatic Star Delta starter with Dry run trip, Single phasing and Phase reversel protection , CT coils and relays suitable for 10 HP capacity.\nMake - Havells/L&T/ Crompton Greaves | 2 | Each | |
| 64 | 32.07 | Automatic Star Delta starter with Dry run trip, Single phasing and Phase reversel protection , CT coils and relays suitable for 5 HP capacity.\nMake - Havells/ L&T/ Crompton Greaves | 2 | Each | |
| 65 | 32.08 | DOL starter up to 7.5HP Capacity. Complete all as specified and directed.\nMake - Havells/ L&T/ Siemens | 2 | Each | |
| 66 | 32.09 | Single phase Preventor Make - minilac or equivallent to L&T, C & S, HPL | 5 | Each | |
| 67 | 32.1 | Timer switch- Make - L&T, C & S, HPL | 5 | Each | |
| 68 | 32.11 | Automatic Star Delta starter with, Single phasing and Phase reversel protection , CT coils and relays suitable for 20 HP capacity.\nMake - Havells/L&T/ Crompton Greaves | 1 | Each | |
| 69 | 32.12 | Automatic Star Delta starter with, Single phasing and Phase reversel protection , CT coils and relays suitable for 30 HP capacity.\nMake - Havells/L&T/ Crompton Greaves | 2 | Each | |
| 70 | 32.13 | Over load relay switch complete all as specified and directed. Make - L&T/Siemens/C&S. | 5 | Each | |
| 71 | 32.14 | C T Coil suitable for submersible motor starter any capacity. Complete all as specified and directed. Make - L&T/Siemens/C&S. | 5 | Each | |
| 72 | 32.15 | DOL Starter coil up to 7.5HP capacity. Complete all as specified and directed. Make - L&T/Siemens/C&S. | 5 | Each | |
| 73 | 32.16 | DOL Starter spare kit suitable up to 7.5HP capacity motors. Complete all as specified and directed. Make - Minilac/L&T/AE | 5 | Each | |
| 74 | 32.17 | Contactor up to 5HP submersible motor controller. Complete all as specified and directed. Make - L&T/C&S/Siemens | 5 | Each | |
| 75 | 32.18 | Push button suitable for control panels (Red&Green) complete all as directed. Make - Siemens/Legrand/L&T | 10 | Each |
AI Tender Summary
Tender Timeline
Sep 23, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedOct 14, 2019
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 16, 2019
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender