Sales : +91-777 804 8217
| Name of Work: Construction of Half Way/ Long Stay Homes at - IHBAS, Delhi | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqmon plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m,including getting out the excavated soil and disposal of surplus excavated soil asdirected, within a lead of 50 m. | |||
| 2 | 1.01 | All kinds of soil. | 152 | Cum | |
| 3 | 2 | Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposing of surplus excavated soil as directed, within lead of 50m. | |||
| 4 | 2.01 | All kinds of soil. | |||
| 5 | 2.02 | Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia | 212 | Cum | |
| 6 | 3 | Supplying chemical emulsion in sealed containers including delivery as specified. 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% | 500 | Litre | |
| 7 | 4 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : | |||
| 8 | 4.01 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration | 4453.71 | sqm | |
| 9 | 5 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. | |||
| 10 | 5.01 | All kinds of soil | 1891.88 | cum | |
| 11 | 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 650.45 | cum | |
| 12 | 7 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 276.31 | cum | |
| 13 | 8 | Extra for levelling & neatly dressing of disposed soil completely asdirected by Engineer-in-charge. | 196.81 | cum | |
| 14 | 8.01 | CONCRETE WORK | |||
| 15 | 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : | |||
| 16 | 9.01 | 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) | 14 | Cum | |
| 17 | 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : | |||
| 18 | 10.01 | 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). | 608.74 | cum | |
| 19 | 10.02 | REINFORCED CEMENT CONCRETE | |||
| 20 | 11 | Centering and shuttering including strutting, propping etc. and removal of form for : | |||
| 21 | 11.01 | Foundations, footings, bases of columns, etc. for mass concrete. | 128.56 | sqm | |
| 22 | 11.02 | Walls (any thickness) including attached pilasters, butteresses,\nplinth and string courses etc. | 531.86 | sqm | |
| 23 | 11.03 | Suspended floors, roofs, landings, balconies and access\nplatform | 4087.7 | sqm | |
| 24 | 11.04 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. | 3389.57 | sqm | |
| 25 | 11.05 | Columns, Pillars, Piers, Abutments, Posts and Struts | 148.12 | sqm | |
| 26 | 11.06 | Stairs, (excluding landings) except spiral-staircases | 353.44 | sqm | |
| 27 | 11.07 | Weather shade, Chajjas, corbels etc., including edges | 132.37 | sqm | |
| 28 | 12 | Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. | |||
| 29 | 12.01 | 50 mm thick | 239.4 | sqm | |
| 30 | 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. | |||
| 31 | 13.01 | Thermo-Mechanically Treated bars. | 20680.7 | kilogram | |
| 32 | 14 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor V level | |||
| 33 | 14.01 | Thermo-Mechanically Treated bars. | 111359 | kilogram | |
| 34 | 15 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).\n | |||
| 35 | 15.01 | All works upto plinth level | 153.19 | cum | |
| 36 | 15.02 | All works above plinth level upto floor V level | 824.88 | cum | |
| 37 | 16 | Add or deduct for plaster drip course /groove in plastered surface or moulding to R.C.C. projections. | 348.14 | metre | |
| 38 | 16.01 | BRICK WORK | |||
| 39 | 17 | Brick work with F.P.S. bricks of class designation 10 in foundation and plinth in: | |||
| 40 | 17.01 | Cement mortar 1:6 (1 cement : 6 coarse sand) | 1066.66 | cum | |
| 41 | 18 | Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level. | |||
| 42 | 18.01 | Cement mortar 1:4 (1 cement :4 coarse sand) | 1298.77 | sqm | |
| 43 | 19 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks). | 1298.77 | sqm | |
| 44 | 19.01 | MARBLE AND GRANITE WORK | |||
| 45 | 20 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for flooring, staircase treads , riers and landings, kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. | |||
| 46 | 20.01 | Granite of any colour and shade | |||
| 47 | 20.02 | Area of slab upto 0.50 sqm | 82.47 | sqm | |
| 48 | 21 | Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. | |||
| 49 | 21.01 | Granite of any colour and shade | 130.35 | metre | |
| 50 | 22 | Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. | 130.35 | metre | |
| 51 | 23 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. | 82.47 | sqm | |
| 52 | 23.01 | WOOD AND PVC WORK | |||
| 53 | 24 | Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). | |||
| 54 | 24.01 | 18 mm thick | 549.84 | sqm | |
| 55 | 25 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. | 224 | each | |
| 56 | 26 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : | |||
| 57 | 26.01 | 250x10 mm | 224 | each | |
| 58 | 26.02 | 200x10 mm | 224 | each | |
| 59 | 27 | Providing and fixing 50cm long aluminium kicking plate 100x3.15 mm anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with necessary screws etc. complete. | 224 | each | |
| 60 | 28 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : | |||
| 61 | 28.01 | 125 mm | 448 | each | |
| 62 | 28.02 | 100 mm | 20 | each | |
| 63 | 29 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. | |||
| 64 | 29.01 | Twin rubber stopper | 224 | each | |
| 65 | 30 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles for aluminium door with necessary screws etc. complete ( best make of approved quality) | 120 | each | |
| 66 | 31 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be\nacceptable. | |||
| 67 | 31.01 | Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm). | 479.92 | sqm | |
| 68 | 32 | Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).\nNote: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. | |||
| 69 | 32.01 | Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate imension. (Area of door above 2.00 sqm upto 5.00 sqm) | 1014.95 | sqm | |
| 70 | 33 | Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/ top hung uPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge. | |||
| 71 | 33.01 | 300 x 19 x 1.9 mm | 1192 | each | |
| 72 | 34 | Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete. | 596 | each | |
| 73 | 35 | Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC sliding window with necessary screws etc. complete. | 298 | each | |
| 74 | 36 | Providing and fixing steel roller for uPVC sliding window with necessary screws etc. complete. | 596 | each | |
| 75 | 37 | Providing and fixing steel roller for uPVC sliding door with necessary screws etc. complete. | 282 | each | |
| 76 | 38 | Providing and fixing steel (white power coated) crescent lock for uPVC sliding window/ door with necessary screws etc. complete. | 439 | each | |
| 77 | 38.01 | STEEL WORK | |||
| 78 | 39 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. | |||
| 79 | 39.01 | In gratings, frames, guard bar, ladder, railings, brackets, gates\nand similar works | 14830.6 | Kg | |
| 80 | 40 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). | 675.38 | Kg | |
| 81 | 40.01 | FLOORING | |||
| 82 | 41 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : | |||
| 83 | 41.01 | 25 mm thick | 2348.3 | sqm | |
| 84 | 42 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. | 323.03 | sqm | |
| 85 | 43 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. | 2060.69 | sqm | |
| 86 | 44 | Providing and laying rectified ceramic glazed tiles 300 x300 mm or more (thickness to be specified by the manufacture) of 1st quality conforming to IS :15622 of approved make and all colour and shades except white, Ivory, Grey, Fume, Red brown laid on 20mm thick cement morter 1:4 (1cement : 4coarse sand) including pointing the joint with white cement and matching pigments etc. complete | 531.73 | sqm | |
| 87 | 45 | Providing and laying Vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less then 8% and conforming to IS :15622 of approved make and colour and shades laid on 20mm thick cement morter 1:4 (1cement : 4coarse sand) including grouting the joint with white cement and matching pigments etc. complete size of Tile 100 cm x 100 cm | 1941.68 | sqm | |
| 88 | 45.01 | ROOFING | |||
| 89 | 46 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. | 161 | each | |
| 90 | 47 | Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring ‘T’ with : | |||
| 91 | 48 | GI Metal Ceiling Clip in plain Beveled edge global white color\ntiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. | 50 | sqm | |
| 92 | 48.01 | FINISHING | |||
| 93 | 49 | 15 mm cement plaster on the rough side of single or half brick wall\nof mix : | |||
| 94 | 49.01 | 1:4 (1 cement: 4 fine sand) | 546.52 | sqm | |
| 95 | 50 | Finishing walls with textured exterior paint of required shade : | |||
| 96 | 50.01 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm | 546.52 | sqm | |
| 97 | 51 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : | |||
| 98 | 51.01 | Two or more coats applied on walls @ 1.25 ltr/10 sqm over and\nincluding one coat of Special primer applied @ 0.75 ltr / 10 sqm | 10892.3 | sqm | |
| 99 | 52 | Applying priming coat : | |||
| 100 | 52.01 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works | 113.56 | sqm | |
| 101 | 52.02 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) | 113.56 | sqm | |
| 102 | 53 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. | |||
| 103 | 53.01 | On steel work | 113.56 | sqm | |
| 104 | 54 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : | |||
| 105 | 54.01 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture | 1341.48 | sqm | |
| 106 | 55 | Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. | 10892.3 | sqm | |
| 107 | 55.01 | ROAD WORK | |||
| 108 | 56 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622, of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. | 34.95 | sqm | |
| 109 | 56.01 | SANITARY INSTALLATIONS | |||
| 110 | 57 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. | |||
| 111 | 57.01 | Flexible pipe | |||
| 112 | 57.02 | 32 mm dia | 106 | each | |
| 113 | 58 | Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40mm long screws, rawl plugs etc. complete. | 78 | each | |
| 114 | 58.01 | WATER SUPPLY | |||
| 115 | 59 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.\r\nConcealed work including cutting chases and making good the walls etc., | |||
| 116 | 59.01 | 20 mm nominal outer dia .Pipes. | 1399 | metre | |
| 117 | 59.02 | 25 mm nominal outer dia .Pipes. | 700 | metre | |
| 118 | 60 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. | |||
| 119 | 60.01 | 20 mm nominal outer dia .Pipes. | 120 | metre | |
| 120 | 60.02 | 25 mm nominal outer dia .Pipes. | 100 | metre | |
| 121 | 60.03 | 32 mm nominal outer dia .Pipes. | 100 | metre | |
| 122 | 60.04 | 40 mm nominal outer dia .Pipes. | 400 | metre | |
| 123 | 60.05 | 50 mm nominal outer dia .Pipes. | 180 | metre | |
| 124 | 61 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | |||
| 125 | 61.01 | Circular tank | 60000 | Per liter | |
| 126 | 62 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. | 78 | each | |
| 127 | 63 | Cutting holes upto 30x30 cm in walls including making good the same : | |||
| 128 | 63.01 | With common burnt clay F.P.S. (non modular) bricks. | 75 | each | |
| 129 | 63.02 | D R A I N A G E | |||
| 130 | 64 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipesincluding bed concrete as per standard design: | |||
| 131 | 64.01 | 250 mm diameter S.W. pipe | 565 | meter | |
| 132 | 65 | Providing and fixing square-mouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : | |||
| 133 | 65.01 | 150 x 100 mm size P type. | |||
| 134 | 65.02 | With sewer bricks conforming to IS : 4885 | 40 | each | |
| 135 | 66 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead anddisposal of unserviceable materials into municipal dumps: | |||
| 136 | 66.01 | 150 mm diameter | 10 | meter | |
| 137 | 67 | Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : | |||
| 138 | 68 | 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : | |||
| 139 | 68.01 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 26 | each | |
| 140 | 69 | Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : | |||
| 141 | 69.01 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 22 | each | |
| 142 | 70 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : | |||
| 143 | 70.01 | With 20x20 mm square bar | 110 | each | |
| 144 | 71 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality | |||
| 145 | 71.01 | Square shape 450 mm internal dimensions | 64 | each | |
| 146 | 72 | Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : | |||
| 147 | 72.01 | Rectangular manhole 90x80 cm with rectangular cover 600x450 mm of grade LD - 2.5 | 3 | each | |
| 148 | 72.02 | Circular manhole 140 cm dia with circular cover 600 mm dia of grade EHD - 35 | 50 | each | |
| 149 | 73 | Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : | |||
| 150 | 73.01 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 64 | each | |
| 151 | 73.02 | ALUMINIUM WORK | |||
| 152 | 74 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : | |||
| 153 | 74.01 | Powder coated aluminium (minimum thickness of powder coating 50 micron) | 4643.31 | kg | |
| 154 | 75 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). | |||
| 155 | 75.01 | Powder coated aluminium (minimum thickness of powder coating 50 micron) | 2995.12 | kg | |
| 156 | 76 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) : | |||
| 157 | 76.01 | With float glass panes of 5.50 mm thickness | 1062.63 | sqm | |
| 158 | 76.02 | WATER PROOFING | |||
| 159 | 77 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry | 531.73 | Sqm | |
| 160 | 78 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to\nIS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : | |||
| 161 | 78.01 | With average thickness of 120 mm and minimum\nthickness at khurra as 65 mm. | 1581.58 | Sqm | |
| 162 | 78.02 | RAIN WATER HARVESTING & TUBEWELLS | |||
| 163 | 79 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. | |||
| 164 | 79.01 | All types of soil 300 mm Dia | 240 | meter | |
| 165 | 80 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. | |||
| 166 | 80.01 | 200 mm nominal size dia | 120 | meter | |
| 167 | 81 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. | |||
| 168 | 81.01 | 200 mm nominal size dia | 120 | meter | |
| 169 | 82 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | 24.52 | Cum | |
| 170 | 83 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | 24.52 | Cum | |
| 171 | 83.01 | NON DSR ITEMS (Civil) | |||
| 172 | 84 | Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor five level.Masonry work (first sort) , in cement mortar 1:6 (1 cement : 6 coarse sand) | 1005.34 | Sqm | |
| 173 | 85 | Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 10 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement :6 coarse sand). | |||
| 174 | 85.01 | Above plinth level upto floor V level | 1156.31 | cum | |
| 175 | 86 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 10 in superstructure above plinth level up to floor V level in all shapes and sizes in : | |||
| 176 | 86.01 | Cement mortar 1:6 (1 cement : 6 coarse sand) | 371.95 | cum | |
| 177 | 87 | Providing and laying glass tiles with 1:3 cement mortar directions of engineer-in-charge | 129.9 | Sqm | |
| 178 | 88 | Providing and laying Mandana stone laid on 20 mm (average) thick cement mortar 1:4 (1 cement: 4 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. | 705.8 | Sqm | |
| 179 | 89 | Providing and Fixing M.S Pergola with 6 mm th. M.S sheet CNC cut perforation as/design perforation site covered by 3 mm M.S sheet as per approved design including all fittings directions of engineer-in-charge | 276.22 | Sqm | |
| 180 | 90 | Providing and Fixing 80 th. Sandwitch PUF Panel as per approved design including all fittings directions of engineer-in-charge | 584 | Sqm | |
| 181 | 91 | All primary members (Columns & Rafters) would be fabricated from Plates having minimum yield strength of 240/345Mpa. And will conform to ASTM-A-572 Standard. The primary members would be fabricated by continuous shop automated welding using submerged arc welding. Primary members fabricated from plate will have flanges and webs jointed one side alternate on either side of the web by a continuous welding process. All primary members shall have one coat of primer. including all fittings directions of engineer-in-charge | 13393.5 | Kg | |
| 182 | 92 | The secondary members consist of Z-Purlins and eave struts coated with one coat of primer would be of Cold formed steel having minimum yield strength of 250/320 Mpa and would conform to IS 2062. including all fittings directions of engineer-in-charge | 2343.87 | Kg | |
| 183 | 93 | Supplying, filling, spreading & leveling Pea gravels in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction\nof Engineer-in-charge. | 24.52 | cum | |
| 184 | 94 | Supply of earth by mechanical transport including royality, excavation, loading, unloading and banking the same in layer not exceeding 20 cm in depth, breaking clodss, watering, rolling each layer with 1/2 tonne roller or wooden or steel rammers and rolling each layer with vibratory power roller of minimum 8 tonnes and dressing up with proper chamber for roads including filling up ground depressions with 30 km lead and lift upto 1.5 m : (Rolling by means of compactor (where 8 tonne roller can not be used) to achieve the require DBD shall also be the apart the item). | 1643.52 | cum | |
| 185 | 94.01 | NON DSR ITEMS (Plumbing) | |||
| 186 | 95 | Desilting of gully grating chamber including taking out garvage/malba and stacking with in a lead of 50 meter as per direction of engineer-in-Charge | 3 | each | |
| 187 | 96 | Cleaning of manholes complete including pumping out water and taking all safety measures for gases and taking out sludge and stacking with in a lead of 50 meter and taking necessary safety measures as per direction of Engineer-in-Charge | 3 | each | |
| 188 | 97 | Cleaning of existing chowked sewer line including removing malba/sludge from the line including testing the line after cleaning and disposal of the collected malba as per direction of Engineer-in-charge | 35 | metre | |
| 189 | 98 | Cleaning of existing storm water drain including removing malba/sludge upto a lead of 50 meter lead as per direction of Engineer-in-charge | 35 | metre | |
| 190 | 99 | Providing and fixing CPVC gate valve of approved quality | |||
| 191 | 99.01 | 25 mm nominal bore | 15 | each | |
| 192 | 99.02 | 32 mm nominal bore | 15 | each | |
| 193 | 99.03 | 40 mm nominal bore | 15 | each | |
| 194 | 100 | Providing and fixing CPVC non- return valve of approved quality | |||
| 195 | 100.01 | 40 mm nominal bore | |||
| 196 | 100.02 | Horizontal | 15 | each | |
| 197 | 100.03 | Vertical | 15 | each | |
| 198 | 101 | Providing and fixing uplasticised PVC connection pipe with brass unions : | |||
| 199 | 101.01 | 45 cm length | |||
| 200 | 101.02 | 25mm nominal bore | 30 | each | |
| 201 | 101.03 | 32 mm nominal bore | 30 | each | |
| 202 | 101.04 | 40 mm nominal bore | 30 | each | |
| 203 | 101.05 | 50 mm nominal bore | 20 | each | |
| 204 | 102 | Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipes for soil, waste and vent & rain water, Type-B as per IS13592 : suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:) i.e. bends, tees, junctions (with or without doors), reducers, couplers, cowls, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting,cutting of RCC slab as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. | |||
| 205 | 102.01 | The Pipes will be supported with threaded G I rods & clamps on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site.-Supreme/Prince make. | |||
| 206 | 102.03 | 110 mm outer dia | 1451 | Rm | |
| 207 | 103 | Providing fixing, jointing and testing in position the following UPVC pipes (working pressure 10 kg/sqcm) conforming to IS: 4985 for drainage cut to required lengths including all necessary fittings and specials such as bends, junctions, offsets, making proper connections. Including providing PCC thrust block at 2 mtr. centre to centre. Pipe to be laid below ground level in trenches upto required depth including excavation in all kind of soil, dewatering, refilling, watering, ramming & removing the surplus excavated material and making good the same complete as required. Make - Supreme/ Polypack | |||
| 208 | 103.01 | 110 mm dia. | 100 | Rm | |
| 209 | 103.02 | 160 mm dia. | 80 | Rm | |
| 210 | 103.03 | 200 mm dia. | 315 | Rm | |
| 211 | 103.04 | 250 mm dia | 250 | Rm | |
| 212 | 104 | Providing & Fixing Towel Rack 600 mm long without lower hangers but with three hooks as per direction of Engineer-in-Charge Code : ACN-1181FHN Jaquar | 78 | Nos. | |
| 213 | 105 | Providing & Fixing Soap Dispenser with glass bottel as per direction of Engineer-in-Charge Code: AKP-35735P Jaquar | 78 | Nos. | |
| 214 | 106 | Providing & Fixing Towel Ring Round as per direction of Engineer-in-Charge Code: AKP- 35721P) Jaquar | 78 | Nos. | |
| 215 | 107 | Providing and fixing CP grating of approved quality as per direction of Engineer-in-Charge.Circular type.100 mm nominal dia. | 267 | Nos. | |
| 216 | 108 | Providing and fixing Overhead Shower ( jaquar Code - OHS-1995) | 70 | Nos. | |
| 217 | 109 | Providing & fixing Long body Bib Cock with wall flange (Make :- jaguar Con-107 KN ) | 218 | each | |
| 218 | 110 | Providing & fixing Angular Stop Cock with nuts, washer with C.P. brass flange complete, including cutting and making good the walls, wherever required. Regular body with adjustable wall flange (Make :- jaguar Con-059 KN ) | 288 | each | |
| 219 | 111 | Providing & fixing Concealed Stop Cock with nuts, washer with C.P. brass flange complete, including cutting and making good the walls, wherever required. Regular body with adjustable wall flange (Make :- jaguar Con-089 KN ) | 140 | each | |
| 220 | 112 | Providing & fixing Basin with provision also of all accessories required for installation and testing (Brand- Hindware Star white ) | 78 | each | |
| 221 | 113 | Providing & fixing Pillar Cock Long (Make :- Jaquar Code CQT-23011 ) | 78 | each | |
| 222 | 114 | Providing & fixing Urinal with provision also of all accessories required for installation and testing (Make :- Hindware catalogue no. 60002 FB- Large standard urinal star white ) | 8 | each | |
| 223 | 115 | Providing & fixing 10 Lit. Auto flush Urinal cistern with provision also of all accessories required for installation and testing | 8 | each | |
| 224 | 116 | Providing & fixing Wall-hung European type water closet with provision also of all accessories required for installation and testing (Brand- Hindware Catalogue no 20061 Star white wall mounted closet) | 78 | each | |
| 225 | 117 | Providing & fixing Concealed Cistern with Chrome Plate Brand Viega | |||
| 226 | 117.01 | Supply only, handling, fixing ,testing and all accessories required for installation. | 78 | each | |
| 227 | 118 | Providing & fixing stainless steel sink of size 1120mm x 510mm x 229 mm with 2 bowl with provision also of all accessories required for installation and testing and including cutting and making good the walls wherever required as per direction of Engineer-in-charge. | 23 | each | |
| 228 | 119 | Providing & fixing stainless steel sink of size 838mm x 559mm x 229 mm with 1 bowl with provision also of all accessories required for installation and testing and including cutting and making good the walls wherever required as per direction of Engineer-in-charge. | 3 | each | |
| 229 | 120 | Providing & fixing wall mounted C.P. Sink Mixer with swinging spout complete, including cutting and making good the walls wherever required. (Make :- Jaquar- CON- 309 KN ) | |||
| 230 | 120.01 | Supply only , handling, fixing with provision also of all accessories required for installation and testing | 20 | each | |
| 231 | 121 | Providing and fixing 5.5 mm thk. Mirror mounted on S.S Stud | 126.36 | sqm | |
| 232 | 122 | Supply installation testing and commissioning R.O.water purifier (Kent Grand 8 L RO + UV +UF Water Purifier (White) | 24 | Each | |
| 233 | 123 | Supplying, installing, testing & commissioning of Domestic Water Lifting Pumps to feed Overhead Tank. (1HP) including all fittings as per direction of Engineer-in-charge. | 3 | each | |
| 234 | 123.01 | ELECTRICAL WORK | |||
| 235 | 123.02 | Sub Head:-A (Internal Wiring) | |||
| 236 | 124 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required. | |||
| 237 | 124.01 | Group C | 1468 | Point | |
| 238 | 125 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required | 40 | Point | |
| 239 | 126 | Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required | |||
| 240 | 126.01 | 3 x 1.5 sq.mm | 1900 | Meter | |
| 241 | 126.02 | 6 x 1.5 sq.mm | 550 | Meter | |
| 242 | 126.03 | 9 x 1.5 sq.mm | 7180 | Meter | |
| 243 | 126.04 | 3 x 2.5 sq.mm | 1150 | Meter | |
| 244 | 126.05 | 6 x 2.5 sq.mm | 670 | Meter | |
| 245 | 126.06 | 3 x 4 sq.mm | 1460 | Meter | |
| 246 | 126.07 | 6 x 4 sq.mm | 1050 | Meter | |
| 247 | 126.08 | 3 x 6 sq.mm | 2250 | Meter | |
| 248 | 127 | Supplying and drawing following pair, 0.5 sq.mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required | |||
| 249 | 127.01 | 2 Pair | 1350 | Metre | |
| 250 | 127.02 | 4 Pair | 450 | Meter | |
| 251 | 128 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. | 1100 | Meter | |
| 252 | 129 | Supplying and fixing of following sizes of medium classPVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. | |||
| 253 | 129.01 | 20mm | 5850 | Metre | |
| 254 | 129.02 | 25 mm | 6700 | Metre | |
| 255 | 129.03 | 32 mm | 670 | Meter | |
| 256 | 130 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | |||
| 257 | 130.01 | 15/16 amp switch | 1830 | each | |
| 258 | 130.02 | 6 pin 15/16 amp socket outlet | 873 | each | |
| 259 | 130.03 | Telephone socket outlet | 34 | each | |
| 260 | 130.04 | TV antenna socket outlet | 34 | Each | |
| 261 | 130.05 | Bell Push | 14 | Each | |
| 262 | 131 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required | 214 | Each | |
| 263 | 132 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. | |||
| 264 | 132.01 | 1 or 2 Module (75mm x 75mm) | 873 | Each | |
| 265 | 132.02 | 8 Module (125mm x 125mm) | 150 | Each | |
| 266 | 132.03 | 12 Module (200mm x 150mm) | 50 | Each | |
| 267 | 133 | Supplying and fixing following Modular base & cover on existing modular metal box etc. as required | |||
| 268 | 133.01 | 1 or 2 Module | 873 | Each | |
| 269 | 133.02 | 8 Module | 150 | Each | |
| 270 | 133.03 | 12 Module | 50 | Each | |
| 271 | 134 | Supplying and fixng 3 pin, 5 amp. Ceiling rose on the existing junction box/ wooden bolock including connection etc. as required. | 140 | Each | |
| 272 | 135 | Erection of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all\naccessories including connection etc. as required. | 1200 | Each | |
| 273 | 136 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all tyes, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FR PVC insulated, coppere conductor,single core cable and earthing etc. as required. | 1200 | Each | |
| 274 | 137 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required. | 214 | Each | |
| 275 | 138 | Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.( Up to 450mm sweep) | 106 | Each | |
| 276 | 139 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. | 106 | Each | |
| 277 | 139.01 | MCCB, MCB & DB'S | |||
| 278 | 140 | Supplying and fixing follwing way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). | |||
| 279 | 140.01 | 2+12 way, Double door | 12 | Each | |
| 280 | 141 | Supplying and fixing following way, prewired, TP&N MCB distribution board, of steel sheet for 415 volts, on surface/ recess, complete with loose wire box, terminal connectors for all incoming and outgoing circuit, duly prewired with suitable size FR PVC insulated copper conductor up to terninal bocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, interconnection, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). | |||
| 281 | 141.01 | 8 Way (4+24),Double Door. | 24 | Each | |
| 282 | 141.02 | 12 Way (4+36) Double Door | 12 | Each | |
| 283 | 142 | Supplying and fixing 5 amps ot 32 amps rating, 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other load of following poles in the exisiting MCB DB complete with connections, testing and commissioning etc. as required. | |||
| 284 | 142.01 | Single pole | 170 | Each | |
| 285 | 143 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||
| 286 | 143.01 | 40 amps | 90 | Each | |
| 287 | 144 | Supplying and fixing following rating, four pole,415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||
| 288 | 144.01 | 63 amps | 24 | Each | |
| 289 | 144.02 | CABLE TRAYS | |||
| 290 | 145 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. | |||
| 291 | 145.01 | 100 mm width X 50 mm depth X 1.6 mm thickness | 110 | Meter | |
| 292 | 145.02 | 150 mm width X 50 mm depth X 1.6 mm thickness | 60 | Meter | |
| 293 | 145.03 | 300 mm width X 50 mm depth X 1.6 mm thickness | 110 | Meter | |
| 294 | 145.04 | 600 mm width X 50 mm depth X 2.0 mm thickness | 60 | Meter | |
| 295 | 145.05 | EARTHING | |||
| 296 | 146 | Earthing with G.I. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with without charcoal/coke and salt as required. | 15 | Set | |
| 297 | 147 | Earthing with copper Earth plate 600mmx600mmx3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc.with charcol/coke and salt as reqd. | 5 | Set | |
| 298 | 148 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required | 75 | Mtr | |
| 299 | 149 | Providing and and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. | 200 | Mtr | |
| 300 | 149.01 | MV CABLE LAYING | |||
| 301 | 150 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. | |||
| 302 | 150.01 | Upto 35 sq. mm | 140 | Meter | |
| 303 | 150.02 | Above 35 sq. mm and upto 95 sq. mm | 80 | Meter | |
| 304 | 150.03 | Above 95 sq. mm and upto 185 sq. mm | 12 | Meter | |
| 305 | 151 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/ METAL pipe as required. | |||
| 306 | 151.01 | Above 185 sq. mm and Upto 400 sq.mm | 350 | Meter | |
| 307 | 152 | Laying and fixing of one number PVC insulated and PVC\nsheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. | |||
| 308 | 152.01 | Upto 35 sq. mm (clamped with 1mm thick saddle) | 350 | Meter | |
| 309 | 153 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) | 350 | Meter | |
| 310 | 154 | Above 95 sq. mm and upto 185 sq. mm (clamped with\n25/40x3mm MS flat clamp) | 250 | Meter | |
| 311 | 155 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required | |||
| 312 | 155.01 | Upto 35 sq. mm | 350 | Meter | |
| 313 | 156 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. | |||
| 314 | 156.01 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) | 125 | Meter | |
| 315 | 156.02 | MV CABLE JOINTING & END TERMINATION | |||
| 316 | 157 | Supply and making end termination with brass compression gland and aluminium/copper lugs for following size of PVC insulated and PVC sheated/XLPE aluminium/copper conductor cable of 1.1KV grade as required. | |||
| 317 | 157.01 | 4C x 25 Sq.mm Aluminium armoured | 16 | Each | |
| 318 | 157.02 | 4C x 35 Sq.mm Aluminium armoured | 20 | Each | |
| 319 | 157.03 | 3.5C x 50 Sq.mm Aluminium armoured | 10 | Each | |
| 320 | 157.04 | 3.5C x 70 Sq.mm Aluminium armoured | 8 | Each | |
| 321 | 157.05 | 3.5C x 185 Sq.mm Aluminium armoured | 8 | Each | |
| 322 | 157.06 | 3.5C x 240 Sq.mm Aluminium armoured | 8 | Each | |
| 323 | 158 | Supplying of following sizes PVC insulated and PVC sheathed power cable of 1.1 KV grade armouret L.T cable as required conforming to IS:1554/IS-7098 ( Part-I ) 1998 as reqd at site. | |||
| 324 | 158.01 | 4C x 25 Sq.mm Aluminium armoured | 350 | Meter | |
| 325 | 158.02 | 4C x 35 Sq.mm Aluminium armoured | 450 | Meter | |
| 326 | 158.03 | 3.5C x 50 Sq.mm Aluminium armoured | 350 | Meter | |
| 327 | 158.04 | 3.5C x 70 Sq.mm Aluminium armoured | 250 | Meter | |
| 328 | 158.05 | 3.5C x 185 Sq.mm Aluminium armoured | 125 | Meter | |
| 329 | 158.06 | 3.5C x 240 Sq.mm Aluminium armoured | 70 | Meter | |
| 330 | 159 | Supplying and drawing co- axial TV cable RG-11 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinnned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. | 200 | Meter | |
| 331 | 160 | Supply and fixing modular type A/C box complete with 16amp socket outlet 6 to 32 amp SPMCB, cover plate,connection testing and fixing etc as reqd | 92 | Each | |
| 332 | 161 | Fabrication,Supplying,testing, installation and commissioning of well/ floor mounted cubical panel board/feeder piller duly made out of 2 mm thick (M.S) fully compartmentalized having 200 amps.4 strip aluminium bus bar,interconnection earthing etc. complete as reqd.(Up to 350mm deep) | 15 | Sq.Mtr | |
| 333 | 162 | Supplying and fixing following accessories in the existing panel board complete with connection etc as reqd. | |||
| 334 | 162.01 | 400 amp TPMCCB (GE/L&T) | 3 | Each | |
| 335 | 162.02 | 250 amp TPMCCB (GE/L&T) | 12 | Each | |
| 336 | 162.03 | 200 amp TPMCCB (GE/L&T) | 3 | Each | |
| 337 | 162.04 | 125 amp TPMCCB (GE/L&T) | 25 | Each | |
| 338 | 162.05 | Digital Voltmeter (0-500) | 15 | Each | |
| 339 | 162.06 | Digital Ammeter (0-20) | 12 | Set | |
| 340 | 162.07 | Voltmeter S/S | 12 | Set | |
| 341 | 162.08 | Ammeter S/S | 12 | Set | |
| 342 | 162.09 | Indicating Lamp set.(LED Type) | 12 | Set | |
| 343 | 162.1 | CT'S 400/5 Amp | 3 | Each | |
| 344 | 162.11 | CT'S 250 /5 Amp | 12 | Each | |
| 345 | 162.12 | Sub Head:-B (FITTING & FIXTURE) | |||
| 346 | 162.13 | Supply of mattt finish Horizantal Downlignter 2 X 18 Watt with white powder coated CRCA ring,matt finish aluminium reflector wired with commericial HF ballast without lamp complete accessories in all respect at site.\nBajaj :- BJDR 218 H MFW2EB\n | 768 | Each | |
| 347 | 163 | Supply of Wall mounted MIRROR Luminaire suitable for 1 x 18 watt CFL lamp complete as required. ( Philips make ) cat no. FMS 200/111 | 78 | Each | |
| 348 | 164 | Supply of BULKHEAD Luminaire with toughened frosted glass suitable for 1 no 9 watt CFL lamp complete as required. ( Philips make ) cat no FXC 101 | 116 | Each | |
| 349 | 165 | Supply of lamps for as above fitting complete in all respect at the site..(Make-:Philips/Bajaj/Wipro) | |||
| 350 | 165.01 | 18 Watt CFL Lamp | 1216 | Each | |
| 351 | 166 | Supply of following size of A.C. exhaust fan Size of 300 mm,900RPM single phase heavy duty complete with motor, blade fan and cover complete accessories in all respect.(Make:- Khaitan/Bajaj/Usha) | 106 | Each | |
| 352 | 167 | Supply of 1200mm sweep A.C electric ceiling fan,capicitor type double ball bearing complete with 300mm down rod. Canopies,shackles,blades,but without regulator suitable for operation on 230/240 volts,50Hz,single phase,A.C.supply etc as reqd. (Make-:Bajaj/Usha/Khaitan) | 214 | Each | |
| 353 | 168 | Supplying of 250 mm ( 10\" ) Fresh Air wall fan complete with motor, blade, frame etc as required. | 15 | Each | |
| 354 | 169 | Supply and fixing RJ-45 Computer jack socket for computer LAN point on the existing with modular plate and swith box including connection and testing in all respect at site. | 32 | Each | |
| 355 | 170 | Supply and drawing of following size Cat-06 cable FR PVC insulated copper conductor LAN Cat-06 cable in the existing surface/recess steel/PVC conduit as reqd. | 500 | Meter | |
| 356 | 170.01 | Sub Head C :- (LAN WIRING) | |||
| 357 | 171 | Supply and fixing of Cat 6,Jack White complete in all respect at site. | 32 | Each | |
| 358 | 172 | Supply and fixing of Single port British Style faceplate white (with box) complete in all respect at site. | 32 | Each | |
| 359 | 173 | Supply and fixing of Giga,24 port Jack Panel (Cat-6) complete in all respect at site. | 32 | Each | |
| 360 | 174 | Supply and fixing of Mounting Cord 7 ft Cat 6 complete in all respect at site. | 32 | Each | |
| 361 | 175 | Supply and fixing of Mounting Cord 4 ft Cat 6 complete in all respect at site. | 32 | Each | |
| 362 | 176 | Supply and fixing of 48 port managed switch gigabit SG300 complete in all respect at site. | 2 | Each | |
| 363 | 177 | Supply and fixing of 42U floor standing rack with 230 volt AC fan-4d cable manager-9 12 port PDU,HW-5Pkt,Castor Set complete in all respect at site. | 2 | Each | |
| 364 | 178 | Installation Chages of as above work.(Item No 1 to 7) complete in all respect at site. | 1 | L.S | |
| 365 | 178.01 | Sub Head D:-STREET LIGHTING | |||
| 366 | 179 | Supply installation, wiring, connection, testing & commissioning of external boundary lighting system conforming to the technical specifications and drawings. The work will comprise of: | |||
| 367 | 179.01 | 9meter long MS tubular pole along with 1.5m over hang. Weighing 123Kgs as per I.S:2713-1980 part-I & II. Fixtures will come at top of the pole along with reducer along with base plate of 300mmx300mmx6mm at bottom. | |||
| 368 | 179.02 | Mounting by welding the junction box on the pole. | |||
| 369 | 179.03 | Digging for making foundation of the pole. | |||
| 370 | 179.04 | Erecting the pole by grouting in concrete foundation (The civil construction materials are the part of the supply against this assignment) made out of 1:3:6 mixture of cement concrete. | |||
| 371 | 179.05 | Mounting junction box with connecting strip with 2pole MCB and arrangement for terminating incoming and outgoing three phases cable along with loop in loop out arrangement. | |||
| 372 | 179.06 | Suitable adopter for street light fixture or approved equal on the pole top | |||
| 373 | 179.07 | Connecting the fixture by using 3c*2.5mm PVC flexible copper wires of colour green, red and black from the junction box to fixture at pole top. | |||
| 374 | 179.08 | Testing the connections and completing the installation. | |||
| 375 | 179.09 | Providing two numbers 38m GI Pipe for incoming and outgoing cables from cable laying depth to junction box. | |||
| 376 | 179.1 | Painting the pole with two coats of red oxide and afterward two coats of aluminum paint | |||
| 377 | 179.11 | The incoming cable work, outgoing cable work & the earthing of poles are covered under the cabling, earthing head. | 3 | Each | |
| 378 | 179.12 | SUPPLY OF OUTDOOR FIXTURES | |||
| 379 | 180 | Supply of the following streetlight fixtures complete with control gear balasts, p.f. capacitors control gear box and SON lamps. | |||
| 380 | 180.01 | Philips Cat No. SRP 601/250 with 250W SON Lamp | 15 | Each | |
| 381 | 180.02 | ERECTION OF OUTDOOR FIXTURES | |||
| 382 | 181 | Erection street lighting fixture having 250W, sodium vapout lamp in die cast aluminium housing having an acrylic cover for satisfactory operation in the open. | 10 | Each | |
| 383 | 182 | Supplying, Laying of Hume pipe 300mm dia at crossing of road as per standard practice of putting cement mortor and covering with the excavated earth | 50 | Meter | |
| 384 | 182.01 | Sub Head E:-SAFETY EQUIPMENT | |||
| 385 | 183 | Supplying and erection of the following equipment at suitable place in the building as required :- | |||
| 386 | 183.01 | 4 nos. of M.S bucket of 20 liters capacity with red oxide paint & lettered as \" Fire \" with White and Red mounted on free standing stand, as required including filling with dry SAND. | 2 | Set | |
| 387 | 183.02 | First aid box as approved by St. John Ambulance Bridge | 2 | Each | |
| 388 | 183.03 | Shock treament chart | 2 | Each | |
| 389 | 183.04 | Rubber Mat 914.4 mm wide and 12 mm thick | 4 | Meter | |
| 390 | 183.05 | Rubber Mat 914.4 mm wide and 6 mm thick | 12 | Meter | |
| 391 | 183.06 | Sub Head F:-FIRE FIGHTING SYSTEM | |||
| 392 | 184 | Providing and fixing standard firemans axe with heavy rubber handle. | 8 | Each | |
| 393 | 185 | Providing and fixing Fire Extinguishers (A, B, C type powder) complete with all accessories as per manufacturers specifications. | |||
| 394 | 185.01 | Capacity 5 Kg | 4 | Each | |
| 395 | 185.02 | Capacity 4.5 Kg | 4 | Each | |
| 396 | 185.03 | Capacity 9 Kg | 1 | Each | |
| 397 | 186 | Providing and fixing signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+ -10%) containing lumigen II as base chemical, covered under UV stablized coating and of appropriate size (Glo-lite or eq. Make) including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats anchor fasteners etc. complete in all respacts as diercted by Engineer-in-charge. | 350 | Sq.Inch | |
| 398 | 186.01 | Sub Head G:-(Fire Detection Work) | |||
| 399 | 187 | Supplying, fixing, testing and commissioning photoelectric type smoke detector. | 100 | Each | |
| 400 | 188 | Supplying, fixing, testing and commissioning fixed temperature-cum-Rate of Rise type heat detectors. | 100 | Each | |
| 401 | 189 | Supplying, fixing, testing and commissioning flush type response indicator with red coloured LED Lamp. | 10 | Each | |
| 402 | 190 | Supplying, fixing, testing and commissioning manual break glass units alongwith chain and hammer. | 14 | Each | |
| 403 | 191 | Supplying, fixing, testing and commissioning electronics hooters. | 14 | Each | |
| 404 | 192 | Supplying, installing, testing and commissioning 20 zone Control Panel with zone indication. The panel shall include solid state circuits, battery charger, batteries etc. and fire/fault/test positions selector switches, zone isolation facility etc. complete. | 1 | Each | |
| 405 | 193 | Supplying, fixing, testing and commissioning FRLS PVC insulated 2x1.5 Sq.mm copper conductor unarmoured cable ISI marked | 800 | Meter | |
| 406 | 193.01 | SUB-HEAD H:AIR CONDITIONER WORK. | |||
| 407 | 194 | Supplying, installation, testing & commissioning of Aircooled Split Air-conditioners each comprising an outdoor unit consisting of Rotary Compressor, Condensor fan,etc. with outer casing and indoor Hi-wall Type 1.5 TR unit consisting of blower, filter, motoretc. having specified CFM 230+/_10% ,1-50 Hz alongwith cordless remote, (R-22) 1.5 TR with BEE 4 star rating. | 80 | Each | |
| 408 | 195 | Supplying, installation, testing & commissioning of Aircooled ceiling concealed Air-conditioners each comprising an outdoor unit consisting of Rotary Compressor, Condensor fan,etc. with outer casing and indoor ceiling concealed type 2.0 TR unit consisting of blower, filter, motoretc. having specified CFM 630+/_10% ,1-50 Hz alongwith cordless remote, (R-22 refrigerant) 2.0 TR with BEE 4 star rating. | 12 | Each | |
| 409 | 196 | Installation charges for 1.5 TR Hi-wall type Airconditioner | 80 | Each | |
| 410 | 197 | installation charges for 2.0 TR Ceiling concealed type Airconditioner | 12 | Each | |
| 411 | 198 | Soft Copper Pipe 1/2\"& 1/4\" having thickness of .8 mm for 1.5 TR AC units | 240 | Rmtr | |
| 412 | 199 | Soft Copper Pipe 1/2\"& 3/4\" having thickness of 1.0 mm for 2.0 TR AC units | 24 | Rmtr | |
| 413 | 200 | 4 c (1.5mm) electrical wiring from indoor to outdoor unit (BIS) | 800 | Rmtr | |
| 414 | 201 | 3 c (2.5 sqmm) Electrical wiring from MCB to outdoor units (BIS) | 420 | Rmtr | |
| 415 | 202 | 6 sq mm Electrical wiring from MCB to outdoor units as / BIS | 350 | Rmtr | |
| 416 | 203 | 25 mm Dia. Hard PVC drain pipe | 800 | Rmtr | |
| 417 | 204 | Voltage stabilizers 4 KVA for 1.5 TR A/C | 92 | Each | |
| 418 | 205 | M.S. angle stand for outdoor units | 92 | Each | |
| 419 | 206 | Supply and fixing of Gyeaser/ water heater 25 Ltrs capicity complete as read (Make:-Hevells - WB025 or eqvialent Recold/Smith) | 50 | Nos | |
| 420 | 207 | Add cost index for civil DSR items @12.75% on Rs. 61926258 | 6.19263e+07 | each | |
| 421 | 208 | Less @ 9.5% on DSR items Rs. 61926258 | 6.19263e+07 | each | |
| 422 | 209 | Add cost index for electrical DSR items @12.75% on Rs. 6466580 | 6.46658e+06 | each | |
| 423 | 210 | Less @ 9.5% on electrical DSR items Rs. 6466580 | 6.46658e+06 | each |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail