Repair Replacement Of Certain Us Parts Of Central Package Type Ac Plants Ducts Ahu Electric Panel Boards Cooling Towers Starters Overhauling Of Compressors Descaling Of Oils Dries Belts Etc And Other Em Allied Works Tech Area Of Itr Chandipur, Chandipur-Odisha

Military Engineer Services-MES has published Repair Replacement Of Certain Us Parts Of Central Package Type Ac Plants Ducts Ahu Electric Panel Boards Cooling Towers Starters Overhauling Of Compressors Descaling Of Oils Dries Belts Etc And Other Em Allied Works Tech Area Of Itr Chandipur. Submission Date for this Tender is 12-10-2019. Starter Tenders in Chandipur Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

21904058
Repair Replacement Of Certain Us Parts Of Central Package Type Ac Plants Ducts Ahu Electric Panel Boards Cooling Towers Starters Overhauling Of Compressors Descaling Of Oils Dries Belts Etc And Other Em Allied Works Tech Area Of Itr Chandipur
Open Tender
Indian
Odisha
Chandipur
12-10-2019

Tender Details

Repair Replacement Of Certain Us Parts Of Central Package Type Ac Plants Ducts Ahu Electric Panel Boards Cooling Towers Starters Overhauling Of Compressors Descaling Of Oils Dries Belts Etc And Other Em Allied Works Tech Area Of Itr Chandipur

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work: REPAIR /REPLACEMENT OF CERTAIN UNSERVICEABLE PARTS OF CENTRAL/ PACKAGE TYPE AC PLANTS, DUCTS / AHU, ELECTRIC PANEL BOARDS, COOLING TOWERS STARTERS, OVERHAULING OF COMPRESSORS, DESCALING OF AC PLANTS, REPLACEMENT OF COMPRESSOR OILS, DRIES, BELTS ETC AND OTHER E/M ALLIED WORKS AT LAUNCHING AREA AND TECHNICAL AREA OF ITR CHANDIPUR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M & L for dismantling and taking out unserviceable and defective parts of compressor of chiller Units of Central type AC Plants of capacity 30 TR VOLTAS make , Model No- after disconnecting the discharge & suction line removal of necessary electrical connection etc. Dismantling compressor body complete and carry out the repair work as per the following :-\n(a) Repairs to crank shaft, connecting rod, piston, piston pin valve plate by remetaling, cutting/grinding and polishing as required and by supply and replacing all spare parts with new one as required and directed.\n(b) Repairs /fixing by replacing of all new discharge and suction reeds, big end and small end bush, all bearing, all piston rings, capillary drier cum filter with new one all as specified and directed .\n(c) Repairs/fixing by replacing of all new kinds of gasket, washers, scappring made of Nylon/ Tuflon sheet/ rubber/fibre sheet as required with new one and all as directed.\n(d) Repair of Oil pump kit by , dismantling and cleaning, greasing oiling along with new gasket all as required and directed.\n(e) M & L for Repair/replacement of old u/s copper pipe line as per existing size and shape when found leaking/damage at the time of leak check including necessary flairing, brazing as required and replacement of end fittings made of copper including brass flange nuts, brass dead cap and brass pipe as per site requirement and as directed.( Note : - The cost of new Copper pipe is also included in the same job )\n(f) Supply and fix in repair of all u/s rusted bolts, nuts and washers of any kind/made of any metalical/any size and shape as per site requirement with new one all specified and directed. (Note :- The cost of all types/sizes of new nuts , bolts and washers are included in the same job.\n(g) After the repair work re-assembling the plant and check for leak in system with the help of Nitrogen gas. in case of any leak is detected the repair is to be carried out without any extra cost nitrogen/refrigerant gas. \n(h) After leak repair release Nitrogen and charge with refrigerant gas and testing to be carried out.\nNote : The cost for Nitrogen gas for Leak test, Charging/top up of Compressor oil and refrigerant gas (R-22) and necessery spares will be measured & Paid separately against ser Items No-2 to 13 and ser items No-22 to 26 of this schedule.\n 1 Each Job
2 2 Supply only Suction reed as per existing make and model . 1 Each Set
3 3 Supply only Discharge reed as per existing make and model. 1 Each Set OF 04
4 4 Supply only Main Bearing as per existing make and model 1 Each Set 1
5 5 Supply only Thrust Bearing as per existing make and model 1 Each Set 1
6 6 Supply 0nly Piston Pin as per existing make and model. 1 Each Set OF 4
7 7 Supply only Piston as per existing make and model. 1 Each Set OF 4
8 8 Supply only Piston Ring as per existing make and model 1 Each Set OF 8
9 9 Supply only Discharge and Suction Pin as per existing make and model. 1 Each Set 24
10 10 Supply only Compressor oil ring 1 Each set of 4
11 11 Supply only Supply Valve and Discharge Valve spring 1 Each set of 56
12 12 Supply only unloader sleveas per existing make and model 1 Each set of 4
13 13 Supply only Gasket Set as per existing make and model 1 Each set
14 14 M&L for Carrying out cleaning and de-scaling of iron deposited in condenser shell and tube and outside of the shell and tube of condenser by using chemical suitable for Descalling for the condensor unit of the compressor with the help of monoblock pump set , recommended by manufacturer manual of the respective plant by using suitable cleaning brush and others cleaning materials complete with satisfactory for Capacity 3x26TR Central type Scroll chiller AC Plant of Blue Star make at PP Buildings in ITR tech area ,and all as specified and directed by Engr - in charge. 1 EACH JOB
15 15 All as per item no-14 here -in-before but Central type Ac plant of capacity 3x27.5 TR of ACCEL make at TIC (Knowledge Centre) Buildings in ITR Tech Area and all as specified and directed by Engr - in - Charge\n 1 EACH JOB
16 16 All as per item no-14 here -in-before but Central type AC plants of capacity 3x30 TR of Carrier make at TTD Buildings in ITR tech area and all as specified and diredted by Engr - in chagre 1 EACH JOB
17 17 All as per item no- 14 here -in-before but Central type AC Plants of capacity 3x 30 TR of VOLTAS make at AC Magzine Buildings in ITR Tech Area and all as specified and directed by Engr - in charge.\n 1 EACH JOB
18 18 All as per item no-14 here -in-before but Central type AC Plants of capacity 3x35 TR of Carrier make at New MPO Buildings in ITR Tech area and all as specified and directed by Engr - in charge. 1 EACH JOB
19 19 All as per item no-14 here -in-before but Central Type AC Plant of capacity 3x75 TR of Blue Star make at 06 Building in LC-III area ITR and all as specified and Directed by Enge - in charge. 1 EACH JOB
20 20 All as per item no-14 here -in-before but Central Type AC Plant of capacity 3x90 TR of Blue Star make at Control Centre Building in ITR tech area , and all as specified and Directed by Enge - in charge. 1 EACH JOB
21 21 All as per item no-14 here -in-before but Central Type AC Plant of capacity 2x70 TR of Blue Star make at RADAR Building in ITR Tech Area , and all as specified and Directed by Enge - in charge. 1 EACH JOB
22 22 Pressure testing / leak arresting , vaccuming with dry nitrogen gas at the maximum p;ressure of 300 to 400 PSI / oil charging, incl replacing the unserviceable strainers all as required and testing complete for the Central type AC plant of capacity 25 to 90 TR Capacity at various locations/buildings of ITR tech area and LC area and all as specified and directed by Engr - in charge . \nNote :- (I) Refregerant Gas R-22/407/410/403 and strainers will be measured and paid seperately under suply only items (II) The Nitrigen gas pressure should be not less then 350 PSI during Leak arresting of the plants and it will hold the same pressure upto 24 hours and vaccum pressure should not be less then (-30 micron Pressure) during the Vaccuming of plants. 1 EACH JOB
23 23 Pressure testing / leak arresting , vaccuming with dry nitrogen gas at the maximum p;ressure of 300 to 400 PSI / oil charging, incl replacing the unserviceable strainers all as required and testing complete for the Package type AC plant of capacity 5.5 TR to 16.5 TR at any location/building of ITR tech area and LC area and all as specified and directed by Engr - in charge.\nNote :- (I) Refregerant Gas R-22/407/410/403 and strainers will be measured and paid seperately under suply only items (II) The Nitrigen gas pressure should be not less then 350 PSI during Leak arresting of the plants and it will hold the same pressure upto 24 hours and vaccum pressure should not be less then (-30 micron Pressure) during the Vaccuming of plants. 1 EACH JOB
24 24 Supply only for Recharge/Top up refrigerant R- 22 (Mefron) or equivalent in Central type AC Plants of various capacities complete all as directed . 60 KILO GRAM
25 25 Supply only for Recharge/Top up refrigerant R- 410/413/407C or equivalent in various type of Package/Central type AC Plants of various capacities complete all as directed . 40 KILO GRAM
26 26 Supply and charging/top up of Compressor Oil in various Central type AC plants, Suitable for existing central AC Plants Type : HPL-68 or equivalent as per existing sample \n(Make : SERVO/INDIAN OIL or equivalent as approved) 20 LITRE
27 27 M&L for Supply , assembly and erection of GSS duct 120 GSM rectangular/ Square boxed, incl all accessories such as MS Angles frame at ducts joints for support of ducts , corner, cleat, carriage bolt Gasket and appropriate sealant on longitudinal joints etc comlpete of size 20 SWG icluding taking down unserviceable part and all as directed at site.\nMake :- SAIL/TATA/JINDAL 200 SQM
28 28 M&L for Supply , assembly and erection of GSS duct 120 GSM rectangular/ Square boxed, incl all accessories such as MS Angles frame at ducts joints for support of ducts , corner, cleat, carriage bolt Gasket and appropriate sealant on longitudinal joints etc comlpete of size 22 SWG for branch connection icluding taking down unserviceable part and all as directed at site .SAIL/TATA/JINDAL 20 SQM
29 29 M&L for exposed duct thermal insulation with 50 mm thick thermocol including other binding like CPRX for fixing/bonding of thermocol and plastic and hassain clothes as covering mterials and finished with cement mortar / lath plaster not less then with the help of wire mess of appropate size and finally painting two coat with suitable materials like samosan/distamper or any other water resistance materials to match with existing surface complete all as specified and directed including taking down old unsv materials. 220 SQM
30 30 M&L for dismantling and overhauling of condenser/Chiller water pump set of capacity 15 HP, dismantling pump and motor separately, cutting the burnt out winding from slots and rewinding the same by existing size and gauge of super enamalled copper wire including varnishing, heating, repairing the insulating materials, repalcing bearings, bushes and remetalling the shaft including necessary heat treatment , and repairing the pump , including replacing the gland packing , bearings and all rusted nuts and bolts, washers and remetaling the Impeller of suitable size and bore for lifting the water from source and reassembling the motor and pump with gland packing includings painting of pump amd motor assambly complete with two coats of super enameled paints over one coats of red oxide, fixing the motor & pump at its position and connecting the suction and delivery water pipe and testing under working conditions, complete all as specified and directed. 1 Each Job
31 31 All as per item No.30 here- in- before but of capacity 12.5 HP squirrel cage induction motor.\n(Make-Siemens/CG/Kirloskar/Beacon or any others make ) 1 Each Job
32 32 All as per item No.30 here- in- before but of capacity 10 HP squirrel cage induction motor.\n(Make-Siemens/CG/Kirloskar/Beacon or any others make 1 Each Job
33 33 All as per item No.30 here- in- before but of capacity 7.5 HP squirrel cage induction motor.\n(Make-Siemens/CG/Kirloskar/Beacon or any others make 1 Each Job
34 34 All as per item No.30 here- in- before but of capacity 5 HP squirrel cage induction motor.\n(Make-Siemens/CG/Kirloskar/Beacon or any others make 1 Each Job
35 35 All as per item No.30 here- in- before but of capacity 3 HP squirrel cage induction motor.\n(Make-Siemens/CG/Kirloskar/Beacon or any others make 1 Each Job
36 36 All as per item No.30 here- in- before but of capacity 1/1.5/2 HP squirrel cage induction motor.\n(Make-Siemens/CG/Kirloskar/Beacon or any others make 1 Each Job
37 37 M&L for repair and servicing to squirrel cage induction motor 3 phase 415V, 12.5 HP Kirlosker make or any others make by dismantling of motor from the pump set removing the stater/rotor separately, cleaning, varnishing, heating and drying re-erecting, aligning with the pump, testing, including replacing the bearing and bush, polishing and re-metalling the shaft including necessary heat treatment. Reassembling the motor and pump with new gland packing, supply and fix new gland nuts, bolts, with gland mounting nuts & bolts washers complete , painting the motor and pumps with two coats of synthetic enamel paint after preparing the surfaces all as directed by Engineer-in-charge. fixing the motor & pump on their own base and connecting the suction and delivery water pipes and testing with proper working condition complete all as directed . 1 Each Job
38 38 All as per item No 37 above but induction motor of capacity 10.0 HP. 2 Each job
39 39 All as per item No 37 above but induction motor capacity 7.5 HP. 2 Each job
40 40 All as per item No 37 above but induction motor capacity 5.0 HP. 2 Each job
41 41 All as per item No 37 above but induction motor capacity 3.0 HP. 2 Each job
42 42 All as per item No 37 above but induction motor capacity 2/1.5 HP. 2 Each job
43 43 Supply Fabricate and fixing of MS angle/MS plate/flat/rod for cooling tower frame, CT fan base, cooling tower ladders, and all supports made out of suitable size along with welding/MS nuts, bolts and washers, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removimg existing unserviceable rusted one ,all as specified and directed by Engineer-in-Charge 200 KG
44 44 M&L for spray painting to complete chilled water type Central Air Conditioning plant of 3X30 TR capacity at AC Magazine Building, including complete chiller unit, compressor, motor, condenser refrigerant pipe, water pipe, chilled water pipe line, AHU, cooling tower, LT panel board complete plant with two coat of synthetic enamelled paint including preparation of surfaces and as per colour code all as specified and directed by Engineer - in - charge.\nMake :- Asian paint or any others equivalent paints 1 EACH JOB
45 45 All as per item No. 44 above but for 3X 27.5 TR chiller type AC Plant at TIC (knowledge Centre) Building 1 EACH JOB
46 46 Servicing of electric control panel/compressure control pannel board by taking out the burnt wire. Supply & fixing new wire of existing specification with clipping and socketing and dressing properly complete including replacement of the unserviceable spares.\nNote-U/S spares to be measured and paid seperately as supply only items under this schedule . 2 Each Job
47 47 S&F in repair oil seal, O ring, carbon bushing of shaft of central Type AC Plants compressor of 27.5 TR capacity .\n(Make-ACCEL, model-SMC-8-65 or equivalent as approved) 1 EACH set
48 48 All as per item No. 47 here in before but 30/35 TR capacity.\n( Make-VOLTAS/ACCEL) 1 EACH set
49 49 S&F MS pipe 100 mm dia heavy grade with all fittings laid in floors or fixed to walls and ceilings including taking down old MS pipe for Central AC Plant \n(Make : Tata steel/Jindal steel) 20 RUNNING METRE
50 50 S&F MS pipe 80 mm dia heavy grade with all fittings laid in floors or fixed to walls and ceilings including taking down old MS pipe for Central AC Plant \n(Make : Tata steel/Jindal steel) 6 RUNNING METRE
51 51 S&F MS pipe 65 mm dia heavy grade with all fittings laid in floors or fixed to walls and ceilings including taking down old MS pipe for Central AC Plant \n(Make : Tata steel/Jindal steel) 12 RUNNING METRE
52 52 S&F in repair for Insulation of M S Pipe with PUF slab 30 mm thick and including applying bituminuous/CPRX compound and AluminiumI cladding sheet with 26 gauge complete for size 65 mm dia MS pipe 12 RUNNING METRE
53 53 S&F in repair for Insulation of M S Pipe with PUF slab 40 mm thick and including applying bituminuous/CPRX compound and AluminiumI cladding sheet with 26 gauge complete for size 100 mm dia MS pipe 12 RUNNING METRE
54 54 S&F Ratational moulded polyethene PVC tank of cap 2000 ltrs for use as makeup water tank for cooling Tower (cylendrecal vertical with closed top) hoisted and fixed in position of made on iron frame / faricated works incl fitting complete all as specified and directed at site.Make :- Sintex/ 1 Each
55 55 S&F in repair of refillable type drier filter suitable for Central type AC Plant of capacity 26/27.5 /30/35 TR capacity.\n(Make: Voltas/carrier/Accel) 3 EACH
56 56 S&F in repair V Belt (A-52) for compressor motors ,CT fan motors, and blower motors (Make-FENNER/PALYP) or equivalent in others make 4 EACH
57 57 All as per Item No56 above but for B-84 V belt. 12 EACH
58 58 All as per Item No.56 above but for B-86 V belt. 4 EACH
59 59 All as per Item No.56 here-in-before but for C-105 V belt. 4 EACH
60 60 All as per Item No.56 here-in-before but for SPA-1120 V belt. 6 EACH
61 61 S&F in repair entering water temperature(EWT) sensor suitable for 26 TR scroll type AC Plant.(Make: Blue star as per existing model ). 3 EACH
62 62 S&F in repair leaving water temperature(LWT) sensor suitable for 26 TR scroll type AC Plant.(Make: Blue star as per exixting model). 3 EACH
63 63 Supply and fixing of of PVC Fills of size (600x300x150mm), blue colour, sutable for any type of cooling tower of central air conditioning plant 60 EACH
64 64 S&F in repair electronic timer 3-30 sec ,5 A,24 volt AC \n(Cat No.HODT2COZ of GE or equivalent) 2 EACH
65 65 S&F in repair power contactor model no. MNX 25 for AC circuit with AC Coils voltage 220 Volt ,over load relay 25-45 Amps. \n(Make:Cat No.-CS94110 - L&T ) 3 EACH
66 66 S&F in repair power contactor model no. ML 3 for AC circuit with AC Coils voltage 220 Volt ,over load relay 10-25 Amps ( Cat No.- SS90721,and 2NO+2NC front mounted block.\n(Make- L&T or equivalent as approved) 1 EACH
67 67 S&F in repair power contactor model no. ML 1.5 for AC circuit with AC Coils voltage 220 Volt ,over load relay 10-25 Amps (Cat No.- SS91851KOOO,and 2NO+2NC front mounted block.\n(Make- L&T or equivalent as approved ) 1 EACH
68 68 S&F in repair air break contactor with one NO & NC. \n(Make-Model no. 3TF-34 of Siemens or equivalent of L&T) 2 EACH SET
69 69 S&F in repair of single phase preventer 40 Volts in balance VSP II.(Make-Minilec) 2 EACH
70 70 S&F in repair power contactor model no. MNX `12E 4 pole 10 Amps for AC circuit with AC Coils voltage 220 Volt , Make L&T 2 EACH
71 71 S&F in repair power contactor model no. MNX-12 4 pole 10 Amps for AC circuit with AC Coils voltage 220 Volt , Make L&T 2 EACH
72 72 S&F in repair Safety valve 300 PSI of copper material suitable for 25 TR t0 90 TR capacity Central/package type AC plant( as per existing make and model) 1 EACH
73 73 S&F in repair thermometer 0-06 suitable for 25 TR t0 90 TR capacity Central/package type AC plant( as per existing make and model) 10 EACH
74 74 S&F in repair Pressure gauge of maximum 20 Kg of pressure suitable for 25 TR t0 90 TR capacity Central/package type AC plant( as per existing make and model) 10 EACH
75 75 Supply and fixing in repair, Cooling Tower fan Motor of capacity 3 HP , suitable for 70 TR capacity cooling tower including taking down the existing one and all as specified and directed by Engr- in - charge. Make :- Kirlosker/Cromption/Oswal or equivalent in others make 1 EACH JOB
76 76 Supply and fixing in repair Cooling Tower Fan blades (set of four blades) of existing Shape , size and model suitable for 3 HP CT fan Motor and upto 70 TR capacity Cooling tower and all as specified and directed by Engr - in Charge. 1 EACH SET
77 77 Supply and fixing in repair Coupling hub of existing Shape , size and model, suitable for 3 HP CT fan Motor along with its connected accessories like nuts , bolts , washers and Clamps for fixing of Fan blades suitable for upto 70 TR cooling tower and all as specified and directed by Engr - in Charge. 1 EACH SET
78 78 Supply and fixing in repair AHU Filter suitable for Ahu of capacity 70 TR Plant of size 30x30x10 MM and all as specified and directed by Engr - in Charge. 20 EACH JOB
79 79 Supply and fixing in repair , Compressor of capacity 7.5 TR capacity suitable for Package type AC Plants including taking down existing one and all as specified and directed by Engr - in Charge. 1 EACH JOB
80 80 S&F in repair non Returning Valve of 100 mm dia valve PN-1 with brass spindle including gasket, nut bolts washers and connected accessories for proper fixing and all as sopecified and directed by Engr - in charge . \n(Make : Upadhaya/ Kirloskar or any others equivalent 1 EACH
81 81 S&F in repair butterfly valve of 100 mm dia valve PN-1 with brass spindle including gasket, nut bolts . \n(Make : Upadhaya/ Kirloskar or any others equivalent 3 EACH
82 82 S&F in repair butterfly valve of 65 mm dia valve PN-1 with brass spindle including gasket, nut bolts . \n(Make : Upadhaya/ Kirloskar or any others equivalent 6 EACH
83 83 Supply and fixing in repair - MCCB 4 pole 250A 36 KA - in LT panel boards / feeder pillar boxes including disconnecting and removing existing from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement. Make GE, Model No-M-250B or equivalent make/model in havells and Legrand, all as specifed and as directed by Engr-in-charge. 1 EACH
84 84 Supply and fixing in repair, Complete Gasket set of of Central AC Plants of Capacity 27.5 TR at TIC Building and all as specified and directed by Engr - in charge .\nMake of Plant :- ACCEL, Model M-68 1 EACH SET
85 85 Supply,installing, testing and commissioning indoor type LT feeder piller box,of size 1200x1200x400 mm, padestal mounted, CPRI approved factory made totally enclosed, made of 2 mm thick CRCA sheet ,having proper locking arrangement duly painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system mounted on MS chanel of size 40 x 40 x 6 mm and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, complete with the following items housed in including taking down old panel . Make : Star Electric & Engineering Co./L&T/Scheinder\nBUSBAR :- 200 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance(Note- Busbar to MCCB will be connected through suitable size of Busbar/copper cable.\nINCOMING:- (i) 4 pole MCCB of capacity 125 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with microprocessor release, Adjustable overload 40 - 100%, neutral protection 50 - 100% -01 No. Make : L&T cat part No. CM92109OOP1OG or equivalent in schnieder and siemens\n(ii) Digital VAF+PF Meter suitable for 3Ph VAF + PF display, Class 1, 5A. Qty - 1 Make L&T Cat Part No WDV303OC000\n(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set\n(iv) Ammeter 100 Amp with selectopr switch - 01 Nos \n(v) Voltmeter 440 volts with selector switch - 01 Nos \n(vi) CT (125/5A) -03 Nos \nOUTGOING:- (a) MCCB 4 pole of capacity 63 Amps breaking capacity 25 KA with thermal magnetic release adjustable type -05 Nos. \nMake L & T cat part No. CM91712OOHOOG or equivalent in schnieder and siemens 1 EACH JOB
86 86 Supply,installing, testing and commissioning indoor type LT feeder piller box,of size 1200x1200x400 mm, padestal mounted, CPRI approved factory made totally enclosed, made of 2 mm thick CRCA sheet ,having proper locking arrangement duly painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system mounted on MS chanel of size 40 x 40 x 6 mm and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, complete with the following items housed in including taking down old panel . Make : Star Electric & Engineering Co./L&T/Scheinder\nBUSBAR :- 200 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance(Note- Busbar to MCCB will be connected through suitable size of Busbar/copper cable.\nINCOMING:- (i) 4 pole MCCB of capacity 100 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with microprocessor release, Adjustable overload 40 - 100%, neutral protection 50 - 100% -01 No. Make : L&T cat part No. CM92109OOP1OG or equivalent in schnieder and siemens\n(ii) Digital VAF+PF Meter suitable for 3Ph VAF + PF display, Class 1, 5A. Qty - 1 Make L&T Cat Part No WDV303OC000\n(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set\n(iv) Ammeter 100 Amp with selectopr switch - 01 Nos \n(v) Voltmeter 440 volts with selector switch - 01 Nos \n(vi) CT (125/5A) -03 Nos \nOUTGOING:- (a) MCCB 4 pole of capacity 40 Amps breaking capacity 25 KA with thermal magnetic release adjustable type -05 Nos. Make L & T cat part No. CM91712OOHOOG or equivalent in schnieder and siemens 1 EACH JOB
87 87 Supply,installing, testing and commissioning indoor type LT feeder piller box,of size 1200x1200x400 mm, padestal mounted, CPRI approved factory made totally enclosed, made of 2 mm thick CRCA sheet ,having proper locking arrangement duly painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system mounted on MS chanel of size 40 x 40 x 6 mm and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, complete with the following items housed in including taking down old panel . Make : Star Electric & Engineering Co./L&T/Scheinder\nBUSBAR :- 200 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance(Note- Busbar to MCCB will be connected through suitable size of Busbar/copper cable.\nINCOMING:- (i) 4 pole MCCB of capacity 63 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with microprocessor release, Adjustable overload 40 - 100%, neutral protection 50 - 100% -01 No. Make : L&T cat part No. CM92109OOP1OG or equivalent in schnieder and siemens\n(ii) Digital VAF+PF Meter suitable for 3Ph VAF + PF display, Class 1, 5A. Qty - 1 Make L&T Cat Part No WDV303OC000\n(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set\n(iv) Ammeter 100 Amp with selectopr switch - 01 Nos \n(v) Voltmeter 440 volts with selector switch - 01 Nos \n(vi) CT (125/5A) -03 Nos \nOUTGOING:- (a) MCCB 4 pole of capacity 32 Amps breaking capacity 25 KA with thermal magnetic release adjustable type -05 Nos.\nMake L & T cat part No. CM91712OOHOOG or equivalent in schnieder and siemens\n 1 Each Job
88 88 Supply and fix in repairs LED indication Lamps for R,Y,B Phase\nMake : Suman Electric or equivalent in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement/existing make/model. 6 Each
89 89 Supply and fix in repairs Push Button Switches (Red and Green, in Colour)\nMake : Suman Electric or equivalent in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement/existing make/model. 4 Each
90 90 Supply and fix in repairs Selector Switch 3 way ON-OFF 415V\nMake : Suman Electric or equivalent Make : Suman Electric or equivalent in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement/existing make/model. 2 Each
91 91 Supply and fix in repairs Ammemeter analog type range above 100A below 300A\nMake : Suman Electric or equivalent in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement/existing make/model. 4 Each
92 92 Supply and fix in repairs Voltmeter Analog type range upto 600Volts Make : Suman Electric or equivalent in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement/existing make/model. 4 Each
93 93 Servicing and Maintenance including minor repairs and making in serviceable condition of the package type AC Plants of 5.5/7.5/11.0/16.5 TR capacity comprising of all minor parts and machineries including charging of R - 410/407/22 Gas and when ever required repair and maint of compressor and blower motor Air filters de-humidifying coils lt control pannels , PCB, ducts and accessories of all gauges and meters and keeping in perfect working condution all as specified and directed by the Engr-in-charge .Note : Leak test,refrigerant Gas will be measured and paid seperately under relevent items of schudle if any required . 55 Each Job
94 94 S&F in repair three phase Control PCB for package type AC plant of 5.5 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge. \n 1 Each Job
95 95 S&F in repair three phase Control PCB for package type AC plant of 7.5 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge. \n 1 Each Job
96 96 S&F in repair three phase Control PCB for package type AC plant of11.0 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge. \n 1 Each Job
97 97 S&F in repair three phase Control PCB for package type AC plant of16.0 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge. \n 1 Each Job
98 98 S&F in repair Air sensor for package type AC plant of 5.5/7.5/11.0 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge. \n 1 Each Job
99 99 S&F in repair Coil sensor for package type AC plant of 5.5/7.5/11.0 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge. \n 1 Each Job
100 100 S&F in repair PVC Cable/wire Connectorof size 20mm dia (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge. \n 5 Each
101 101 S&F in repair PVC Cable/wire Connectorof size 25mm dia (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge. \n 5 Each Job
102 102 S&F in repair fan capacitor of 10+-2% mfd capacity suitable for out door unit of package type AC plant of 5.5/7.5/11.0 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge. \n 5 Each Job
103 103 Supply and fixing in repair 4 Core 10 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for connection of package/central type AC plant. 100 RM
104 104 Supply and fixing in repair MCB TPN 63 Amps for connection of package/central type AC plant as main incommer 2 Each
105 105 Supply and fixing in repair MCB TPN 40 Amps for connection of package/central type AC plant. 1 Each
106 106 Supply and fixing, V belt of suitable sizes for 5.5TR capacity Package type AC plant blower motor. \nMake : FENNER/Dunlop 2 Each
107 107 Supply and fixing for V belt of suitable sizes for 7.5 TR blower motor Make : FENNER/Dunlop 2 Each
108 108 Supply and fixing for V belt of suitable sizes for 11.0 TR blower motor Make : FENNER/Dunlop/continental 2 Each
109 109 Supply and fixing for V belt of suitable sizes for 16.5 TR blower motor Make : FENNER/Dunlop 2 Each
110 110 M&L for replacement of U/S Canvas cloths heavy duty of package/centraltype AC plants including provisiong of zip 150 mm lenth for opening and closing arrangements and properlly fasterners with bolts and nuts between the ducts and dumpers of the plants and all as directed by the Eng-in-charge 4 Each Job
111 111 Supply and fixing Flow swithch 25 mm dia suitable for 26 TR central AC plant all as specified and directed by engr in charge . 2 Each
112 112 Supply and fixing GI tubing medium grade with all fittings laid in trenches, floor, roof and wall and tank connection complete including cutting and thereading with all fittings like tee, elbow bend union reducer hex nipple etc and all as required at site for the following sizes :- .
113 112.01 40mm bore 6 RM
114 112.02 25mm bore 12 RM
115 112.03 20mm bore 6 RM
116 113 S&F in repairs gun metal gate valve ISI marked with iron wheel head, screwed both ends for iron pipe of following sizes including taking down the unserviceable existing ones :-
117 113.01 40mm bore 2 Each
118 113.02 25mm bore 4 Each
119 113.03 20mm bore 5 Each
120 114 Supply and fix in repair PVC Ball valve ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. The following sizes.Make :- Prayag ISI marked High Pressure (HP)
121 114.01 40mm bore (minimum wt 690 gms) 2 Each
122 114.02 25mm bore (minimum wt 455 gms) 3 Each
123 114.03 20mm bore (minimum wt 210 gms) 1 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail