| 1 | 1 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. | BI01010001010000000000000515BI0100001112 | 80 | sqm |
|---|
| 2 | 2 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) | BI01010001010000000000000515BI0100001113 | 1 | cum |
|---|
| 3 | 3 | Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely groundedhydrated lime by volume of cement.Ordinary cement finish using ordinary cement | BI01010001010000000000000515BI0100001114 | 150 | sqm |
|---|
| 4 | 4 | Neat cement punning. | BI01010001010000000000000515BI0100001115 | 80 | sqm |
|---|
| 5 | 5 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001116 | 50 | sqm |
|---|
| 6 | 6 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. sqm 20.05 | BI01010001010000000000000515BI0100001117 | 150 | sqm |
|---|
| 7 | 7 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20\nkg/ 10 sqm) | BI01010001010000000000000515BI0100001118 | 350 | sqm |
|---|
| 8 | 8 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | BI01010001010000000000000515BI0100001119 | 150 | sqm |
|---|
| 9 | 9 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m.\nAll kinds of soilnew work | BI01010001010000000000000515BI0100001120 | 500 | 100sqm |
|---|
| 10 | 10 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in- charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | BI01010001010000000000000515BI0100001121 | 1.5 | cum |
|---|
| 11 | 11 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :\n In 75x75 mm deep chase | BI01010001010000000000000515BI0100001122 | 20 | mtr |
|---|
| 12 | 12 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. | BI01010001010000000000000515BI0100001123 | 1 | each |
|---|
| 13 | 13 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conformingto IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter | BI01010001010000000000000515BI0100001124 | 10 | metre |
|---|
| 14 | 14 | Wiring for circuit/submain wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit as required.4 x 10 sqmm + 2 x 10 sqmm earth wire | BI01010001010000000000000515BI0100001125 | 4 | each |
|---|
| 15 | 15 | Grading roof for water proofing treatment withCement mortar 1:3 (1 cement : 3 coarse sand) | BI01010001010000000000000515BI0100001126 | 1.5 | cum |
|---|
| 16 | 16 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of themembrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal andtransverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick | BI01010001010000000000000515BI0100001127 | 30 | sqm |
|---|
| 17 | 17 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. | BI01010001010000000000000515BI0100001128 | 10 | cum |
|---|