Housing Urban and Rular Development Government Departments Closing in 0 days TDR #21884363

Construction Of Demonstration Housing Project On Design And Build Basis At Panchkula , Haryana Construction Of Demonstration Housing Project For Use As Working Women Hostel On Design And Build Basis Using Emerging Technology Including On Site Infrastruct

Issued by Government Departments · Sector 27 Panchkula Haryana, Haryana
Tender Value
5.57 Crore
Estimated cost
Bid Submission
14 Oct 2019
0 days left
EMD
11.15 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sector 27 Panchkula Haryana → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Demonstration Housing Project On Design And Build Basis At Panchkula , Haryana Construction Of Demonstration Housing Project For Use As Working Women Hostel On Design And Build Basis Using Emerging Technology Including On Site Infrastructure Work At Panchkula , Haryana

BOQ

Name of Work: CONSTRUCTION OF DEMONSTRATION HOUSING PROJECT ON DESIGN & BUILD BASIS AT PANCHKULA, HARYANA
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11HEAD A - DWELLING UNITS AND OTHER PROVISIONS
21.01Total Cost of construction of Dwelling Units and other provisions including all associate facilities & services and mumty complete in all respect as per scope of work with specifications and drawings mentioned in Bid document & including GST, Labour Cess and other Taxes1L.S.
32HEAD B - ON SITE INFRASTRUCTURE WORKS (on Item Rate Basis) including GST, Labour Cess and other Taxes
42.01SUB-HEAD 1
52.02EARTH FILLING
62.03Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.1142.1Cum
72.04Extra for lead beyond 5 km (Rate Only)1cum
82.05Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.1142.1Cum
92.06Extra for Dewatering work (Rate only)1Hour
103SUB-HEAD 2
113.01BOUNDARY WALL WITH ENTRANCE GATE
123.02Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil as directed, within a lead of 50 m. as per direction of BMTPC for following depths, below natural ground / Road top level. All kinds of soil
133.03Depth upto 1.5 m84Cum
143.04P/L in position cement concrete of specified grade excluding the cost of centering and shuttering – All work up to plinth level:
153.051:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).8.4Cum
163.06Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
173.07Cement mortar 1:6 (1 cement : 6 Coarse sand)70.47Cum
183.08Brick work with non-modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in :
193.09Cement mortar 1:6 (1 cement : 6 Coarse sand)57.96Cum
203.1Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
213.111:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).17.39Cum
223.12Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:
233.131:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size1.38cum
243.14Centering and shuttering including strutting, propping etc. and removal of form for :
253.15Foundation, base of walls, columns etc.242.24Sqm
263.16Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
273.17Thermo-Mechanically Treated bars of grade Fe-500D or more2345Kg.
283.1812 mm cement plaster of mix :
293.191:6 (1 cement: 6 fine sand)531Sqm
303.2Finishing walls with water proofing cement paint of required shade :
313.21New work (Two or more coats applied @ 3.84 kg/10 sqm)531Sqm
323.22Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel, etc. as required.
333.23Entrance Gate400Kg
343.24Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used.
353.25With G.I. barbed wire500Metre
363.26Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.310Kg.
373.27Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade on MS angels and MS Gate :
383.28Two or more coats on new work over an under coat of ordinary paint50Sqm
394SUB-HEAD 3
404.01ROAD AND PAVEMENT
414.02Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of BMTPC for following depths, below natural ground / Road top level.
424.03Depth upto 1.5 m63.45Cum
434.04Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.126.9Sqm
444.05Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering-all work upto plinth level (100 mm thickness).
454.061:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).13.96Cum
464.07Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering (rate only) process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of authorized representative of BMTPC. (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately) (100 mm thicknes).12.69Cum
474.08Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement Mortar (Toe wall):
484.091:6 (1 Cement: 6 Coarse sand)8.76Cum
494.1Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres.
504.11With common burnt clay F.P.S. (non modular) bricks of class designation 7.545Metre
514.12Interlocking Paver
524.13Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of BMTPC.12.5Sqm
535SUB-HEAD 4
545.01EXTERNAL WATER SUPPLY AND SEWERAGE
555.02Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of authorized representative of BMTPC.
565.0350 mm nominal outer dia Pipes
575.04From Tank to Residential Block (Back side)90Metre
585.0532 mm nominal outer dia pipes100Metre
595.06Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :
605.0720 mm nominal bore48Each
615.08Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
625.0950 mm nominal bore.4Each
635.1SEWERAGE
645.11Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Depth upto 1.5 m
655.12All kinds of soil11.39Cum
665.13Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with Precast RCC cover and frame of approved make 300 x 300 mm internal size:
675.14100x 100 size P Type
685.15With bricks class designation 7512Each
695.16Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design :
705.17Inside size 90x80 cm and 45 cm deep including Precast RCC manhole cover (LD - 2.5) and frame of required shape and approved quality
715.18With bricks with class designation 759Each
725.19Extra for depth for manholes :
735.2Size 90x80 cm
745.21With bricks class designation 759Metre
755.22Providing and fixing uPVC soil/vent/waste SWR pipe of required diameter conforming to IS - 13592:2013 Type B including necessary fittings with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion including necessary excavation, laying, filling, testing etc. all complete.
765.23110 mm dia10Metre
775.24160 mm dia130Metre
785.25Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round pipes including bed concrete as per standard design :
795.26110 mm diameter10Metre
805.27160 mm diameter130Metre
815.28Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
825.29For pipes 100 to 250 mm diameter1Each
836SUB-HEAD 5
846.01DRAINAGE AND DISPOSAL
856.02Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
866.03In all kinds of soil.
876.04Depth upto 1.5 m67.5Cum
886.05P/L in position cement concrete of specified grade excluding the cost of centering and shuttering – All work up to plinth level:
896.061:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).3.6Cum
906.07Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
916.08Cement mortar 1:6 (1 cement : 6 coarse sand)25.88Cum
926.0912 mm cement plaster finished with a floating coat of neat cement of mix :
936.11:4 (1 cement: 4 fine sand)207.5Sqm
946.11Providing and fixing uPVC soil/vent/waste SWR pipe of required diameter conforming to IS - 13592:2013 Type B including necessary fittings with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion including necessary excavation, laying, filling, testing etc. all complete.
956.12110 mm dia36Metre
966.13160 mm dia5Metre
976.14Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of authorized representative of BMTPC.125Each
987SUB-HEAD 6
997.01UNDER GROUND WATER TANK (5.00 M X 2.25 M X 1.5 M)
1007.02Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by authorized representative of BMTPC. Depth upto 1.5 m
1017.03All kinds of soil
1027.04Depth upto 1.5 m17.81Cum
1037.05Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering – All work upto plinth level :
1047.061:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).1.48Cum
1057.071:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size21)1.48Cum
1067.08Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement – All work up to plinth level :
1077.091:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).9.54Cum
1087.1Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
1097.11Thermo-Mechanically Treated bars of grade Fe-500D or more
1107.12Base Slab + Wall + Top Slab1193Kg
1117.13Centering and shuttering including strutting, propping etc. and removal of form for :
1127.14Foundation, base of walls, columns etc3.3Sqm
1137.15Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.44.7Sqm
1147.16Suspended floors, roofs, landings, balconies and access platform11.25Sqm
1157.1712 mm cement plaster of mix :
1167.181:6 (1 cement: 6 fine sand)22.35Sqm
1177.1912 mm cement plaster finished with a floating coat of neat cement of mix :
1187.21:4 (1 cement: 4 fine sand)29.25Sqm
1197.21Providing and fixing MS door (inspection door) with angle frame 35 x 35 x 5 mm of required size including cutting, hoisting and fixing including a coat of primer etc. complete30Kg
1207.22Supply & Installation of Mono Block Pump with starter of approved brand complete (2 HP)2Each
1218SUB-HEAD 7
1228.01RAIN WATER HARVESTING
1238.02Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of authorized representative of BMTPC, upto 90 metre depth below ground level.
1248.03In all type of soil
1258.04300mm dia50Metre
1268.05Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of BMTPC.
1278.06150 mm nominal size dia49Metre
1288.07Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by BMTPC. All kinds of soil
1298.08Pit size 2.7 x 2.0 x 1.8 m13.8cum
1308.09Brick masonary in foundation with brick of class des.75 in CM 1:6
1318.1Size 2.7 x 2.0 x 1.8 m3.48cum
1328.1120 mm cement plaster of mix :
1338.121:6 (1 cement: 6 fine sand)15.12Sqm
1348.13Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of BMTPC.
1358.14Boring2.6Cum
1368.15Supplying, filling, spreading & levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of BMTPC.4.14Cum
1378.16Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering-all work upto plinth level.
1388.171:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).0.64Cum
1398.18Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1408.191:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).0.65Cum
1418.2Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
1428.21Thermo-Mechanically Treated bars of grade Fe-500D or more77.76Kg
1438.22Centering and shuttering including strutting, propping etc. and removal of form for :
1448.23Suspended floors, roofs, landings, balconies and access platform5.4Sqm
1458.24Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of BMTPC.1Each
1469SUB-HEAD 8
1479.01PLINTH PROTECTION
1489.02Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
1499.03Total Building Periphery67.5Sqm
1509.04Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).150Metre
15110SUB-HEAD 9
15210.01HORTILCULTURE
15310.02Supplying and stacking at site dump manure from approved source including all lead and lifts (manure measured in stacks will be reduced by 8% for payment) - screened through sieve of IS designation 20 mm.7.5Cum
15410.03Supplying & stacking sludge at site including royalty & carriage will all leads & lifts (sludge manure measured in stacks will be reduced by 8 % for payment)7.5Cum
15510.04Spreading of sludge / damp manure of / and good earth in required thickness (cost of sludge/ damp manure or / land good earth to paid separately)15Cum
15610.05Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth.
15710.06In rows 15 cm apart in either direction75Sqm
15810.07Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).15Cum
15910.08Supplying & Stacking of Selection No.1 doob grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc. and as per direction of officer in charge.75Sqm
16010.09Supply and Planting of Croton Golden plant, having ht. 45 cm to 60 cm with 2 to 3 branches, well developed, fresh and healthy foliage in 25 cm size of Earthen pot / Plastic pot as per direction of the officer-in-charge.
16110.1Plants40Each
16211SUB-HEAD 10
16311.01EXTERNAL ELECTRIFICATION
16411.02P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, 2nd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
16511.0335.0 Sq.mm70Metre
16611.046.0 Sq.mm500Metre
16711.05Supplying and making one end termination with heavy duty single compression brass gland SIBG type, aluminium lugs duly crimped with crimping tool, PVC tape etc. for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required of size.
16811.063.5 x 35.0 sq.mm6Set
16911.072 x 6.0 sq.mm30Set
17011.08Feeder Pillar
17111.09Supply and fixing of floor mounting, totally enclosed, compartmentalized, cubical, dust, vermin proof and outdoor type. Feeder pillar fabricated out of 2 mm thick cold rolled carbon annealed, sheet steel, internally strengthened with angle iron frame work with following incoming and outgoing feeders (fabricated out of 2 mm CRCA Sheet steel) including making connection / inter-connections with lugs / glands crimping tools, testing and commissioning of following items inside the panel:
17211.1Incommer
17311.111 No. 200 Amp. 4 polse MCCB (25 Ka) with ON/OFF indications metre
17411.12Indication
17511.13Three (3) Nos. phase indicating (R.Y and B) lamps with protection 2A SP MCB's for protection having lens and lamp.
17611.14Outgoing
17711.15One (1) NO. 160 Amp. 4 pole MCCb (16 KA) with ON/OFF indications in the infront 15 nos. 32 A D.P. MCB (10 KA)
17811.16Control
17911.174 Pole Contractor with a thermal rating of 32 - 1 no.
18011.18Time Switch with Daily dial, suitable for operation on 230 Volt, Single phase, 50 Hz, AC supply - 1 No.
18111.19Auto - Manual Selector switch - 1 No.
18211.2On / Off Push Buttons - 4 Nos.2Set
18311.21Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.1Set
18411.22Supply, installation and commissioning of SPV Solar Street Light (white LED Based) System as per specifications including supplying of 75 mm dia (nominal) (Medium class), MS pipe 5.5 metre length (including accessories) complete with base plate and nipple including two coats of black bituminous paint upto 1 mtr. From bottom and two coats of aluminium paint above ground level etc. complete as required. Detail of pole: Planting depth - 1 Mtr and Height above ground level - 4.5 Mtr. over concrete pedestal, 15 Watt LED light Phillips/ Bajaj/ Crompton or Suitable Equivalent.4Nos
18511.23Supply, installation and commissioning of Solar Panel with 500 Watt for 48 number lighting points in common areas (corridor & Staircase) at suitable locations including LED bulbs with 10 Watt1Job
18611.24Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of BMTPC for following depths below natural ground / Road top level.
18711.25In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc.
18811.26Depth upto 1.5 m1.13Nos
18911.27Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level :
19011.281:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size).0.65Cum
19111.29Centering and shuttering including strutting, propping etc. and removal of form for : Foundation etc.2.16Sqm
19211.3Supplying, installing on wall, testing and commissioning of suitable capacity made of 1.6 mm thick sheet steel enclosure duly painted with powder coating, wall straps bus bar 100 amp. of size 400 x 300 mm8Nos

AI Tender Summary

OUR REF NO 21884363
AUTHORITY Government Departments
TENDER VALUE 5.57 Crore
LAST DATE 14-10-2019
Authority
Authority Name building materials and technology promotion council
Work Description Construction Of Demonstration Housing Project On Design And Build Basis At Panchkula , Haryana Construction Of Demonstration Housing Project For Use As Working Women Hostel On Design And Build Basis Using Emerging Technology Including On Site Infrastructure Work At Panchkula , Haryana
Basic Detail
Tender No BMT/S/2019/DHP-Haryana
Bidding Type Tender
Location
City Sector 27 Panchkula Haryana
State Haryana
Key Dates
Publish Date 20 Sep 2019
Submission Date 14 Oct 2019
Open Date 15 Oct 2019
Finance
Tender Value 5.57 Crore
Tender Fee 5000
EMD 11.15 Lakhs
Exemption Not Available
Document List
21CD0DF6-B8CB-4FC6-A0D1-A5D41FB1DFAB.html
Tendernotice_1.pdf
DHPTenderPanchkulaHaryana.pdf
BOQ_528398.xls
7766248_8189_26092019.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 20, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 14, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 15, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

21CD0DF6-B8CB-4FC6-A0D1-A5D41FB1DFAB.html

pdf

Tendernotice_1.pdf

pdf

DHPTenderPanchkulaHaryana.pdf

xls

BOQ_528398.xls

pdf

7766248_8189_26092019.pdf

Disclaimer