| 1 | 1 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, complete all as specified and as directed. | | 90 | Cum |
|---|
| 2 | 2 | Demolition of cement concrete, unreinforced, in ground floors and pavings not exceeding 15cm thickness below or above ground level, complete all as specified and as directed. | | 30 | Cum |
|---|
| 3 | 3 | Demolition of cement concrete (reinforced) of any description and in any position complete all as specified and as directed. | | 10 | Cum |
|---|
| 4 | 4 | Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and as directed. | | 9.5 | Cum |
|---|
| 5 | 5 | Taking down cement plaster on brick or stone walls, including racking out joints, hacking for key, scrubbing down with water etc., to receive new plaster, complete all as specified and as directed. | | 700 | Sqm |
|---|
| 6 | 6 | Dismantling floor, hearth or wall ceramic tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed. | | 100 | Sqm |
|---|
| 7 | 7 | Dismantling wall and ceiling board (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets of any description and any thickness including cover fillets if any, complete all as specified and as directed. | | 80 | Sqm |
|---|
| 8 | 8 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid bedded and pointed in any mortar, complete all as specified and as directed. | | 1 | 10 Sqm |
|---|
| 9 | 9 | Dismantling wrought iron or mild steel work of any description not other wise provided for, complete all as specified and as directed. | | 4.5 | Qtl |
|---|
| 10 | 10 | Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, internal dia of pipe 75mm to 100mm, complete all as specified and as directed. | | 230 | RM |
|---|
| 11 | 11 | Demolition and breaking up drain pipes (salt-glazed stone ware, AC or reinforced concrete) set in cement mortar 100mm dia, complete all as specified and as directed. | | 150 | RM |
|---|
| 12 | 12 | Demolition and breaking up drain pipes (salt-glazed stone ware, AC or reinforced concrete) set in cement mortar 150mm dia, complete all as specified and as directed. | | 320 | RM |
|---|
| 13 | 13 | Demolition and breaking up drain pipes (salt-glazed stone ware, AC or reinforced concrete) set in cement mortar 200mm dia, complete all as specified and as directed. | | 60 | RM |
|---|
| 14 | 14 | Taking up or down steel tubing and connections 15mm dia including cleaning for refixing and removal off the site, complete all as specified and as directed. | | 85 | RM |
|---|
| 15 | 15 | Taking up or down steel tubing and connections 20mm dia including cleaning for refixing and removal off the site, complete all as specified and as directed. | | 40 | RM |
|---|
| 16 | 16 | Taking up or down steel tubing and connections 40mm dia including cleaning for refixing and removal off the site, complete all as specified and as directed. | | 30 | RM |
|---|
| 17 | 17 | Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr deep and getting out complete in any type of soil, complete all as specified and as directed. | | 200 | Cum |
|---|
| 18 | 18 | Returning, filling in, including spreading, leveling watering and well raming in layers not exceeding 25cms thick complete all as specified and as directed. | | 75 | Cum |
|---|
| 19 | 19 | Removal of surplus soil to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed. | | 125 | Cum |
|---|
| 20 | 20 | Plain cement concrete 1:4:8, Type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and as directed. | | 2 | Cum |
|---|
| 21 | 21 | Plain cement concrete 1:2:4 type B-1 as in benching, coping and similar items including weathering, slightly rounded or chamfered angles and throating on top of chajjas, rails, cills etc., complete all as specified and as directed. | | 3.5 | Cum |
|---|
| 22 | 22 | Providing precast reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate in louvers and jallies, 35 mm thick (measured solid), including all mouldings but excluding frame (precast frame shall be measured separately) set in cement mortar 1:4, complete all as specified and as directed. | | 320 | Sqm |
|---|
| 23 | 23 | Precast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate, as in manhole cover slabs and the like, set in cement mortar 1:4, complete all as specified and as directed. | | 10 | Cum |
|---|
| 24 | 24 | Plain cement concrete 1:3:6, Type C-2 using 40mm graded crushed stone aggregate as in surface channels and drains, complete all as specified and as directed. | | 4 | Cum |
|---|
| 25 | 25 | Brick work with sub class “B” bricks straight or curved on plan exceeding 6mtr mean radius built in cement mortar 1:6 using old size bricks, complete all as specified and as directed. | | 60 | Cum |
|---|
| 26 | 26 | All as per description of Srl item No.- 25 here-in-before but except bricks, complete all as specified and as directed. | | 15 | Cum |
|---|
| 27 | 27 | Brick work with sub class “B” bricks straight or curved on plan exceeding 6mtr mean radius built in cement mortar 1:4 using old size bricks, complete all as specified and as directed. | | 10 | Cum |
|---|
| 28 | 28 | All as per description of Srl item No.- 27 here-in-before but except bricks, complete all as specified and as directed. | | 2 | Cum |
|---|
| 29 | 29 | Brick work with sub class “B” bricks straight or curved on plan built to any radius in cement mortar 1:4 using old size bricks in half brick walls, complete all as specified and as directed. | | 25 | Sqm |
|---|
| 30 | 30 | 18 to 20mm thick Granite slab (table rubbed and polished) as in steps, jambs, pillars, window cills, cooking platform and the like, bedded and jointed in cement mortar 1:4 and pointed with white cement with admixture of pigment to match with shade of Granite laid over bedding layer of 15mm thick cement mortar 1:4, complete all as specified and as directed. | | 10 | Sqm |
|---|
| 31 | 31 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, spirally for hopping for columns, hooking ends, and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S or Fe-410-0, complete all as specified and as directed. | | 900 | Kg |
|---|
| 32 | 32 | Mild steel framed work as in doors (as in chowkats) or gates of angle or other section with gusset plates, rails, braces etc., inclusive of steel sheeting 1.00mm thick in covering to doors or other covering, hanging or fastening and fixing complete conforming to Gde Fe-410-0 or Fe-310-0 including shop coat of red oxide including preparation of surface before fixing, complete all as specified and as directed. | | 450 | Kg |
|---|
| 33 | 33 | Mild steel framed brackets of angle or tee, cut to shape as required, drilling holes, notching for wire and counter sunk for screws including bending, welding for fencing work or similar type of work, conforming to Gde Fe-410-0 or Fe-310-0 including shop coat of red oxide, complete all as specified and as directed. | | 200 | Kg |
|---|
| 34 | 34 | Galvanised steel stranded barbed wire 2 strands using wire of 2.24mm dia, with 2mm dia wire barbs at 75mm spacing and straining and fixing to any type of standard rail with straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc. (each line of wire to be measured), complete all as specified and as directed. | | 20 | 100 RM |
|---|
| 35 | 35 | Aluminium anodised snap grid frame work for ceiling fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section ( and hanging with 6 mm dia GI hangers (upto 1200mm length) adjusting level fixed to roof slabs by means of slab cleats madeout of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long, complete all as specified and as directed. | | 80 | Sqm |
|---|
| 36 | 36 | 4mm thick asbestos cement fibre based building boards fixed or laid/inserted to timber/GI/Aluminium framework with screws complete all as specified and as directed. | | 80 | Sqm |
|---|
| 37 | 37 | Vibro compacted Precast concrete interlocking paver blocks, factory made,any shape and size conforming to IS- 15658- 2006 of 60mm thick, M-35 Grade set, jointed in neat cement slurry and pointed flush with grey cement mixed with pigments to match colour of blocks in floors laid over 30mm thick sand cushioning, complete all as specified and as directed. | | 80 | Sqm |
|---|
| 38 | 38 | 50 mm thick plain cement concrete 1:3:6 type C-2, using 40mm graded crushed stone aggregate as in sub base finished even and fair, complete all as specified and as directed. | | 80 | Sqm |
|---|
| 39 | 39 | 75mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection including finishing the surface even and fair, complete all as specified and as directed. | | 220 | Sqm |
|---|
| 40 | 40 | Joint less Non skid ceramic coloured floor tiles of size exc 0.18Sqm but not exceeding 0.36Sqm each tile, 7-8mm thick, as in floors set and jointed in neat cement slurry and pointed in white cement with pigments to match over and including the provision of 15 mm thick bedding layer in cement mortar 1:4, complete all as specified and as directed. | | 25 | Sqm |
|---|
| 41 | 41 | Non skid ceramic coloured floor tiles of size 300mm x 300mm, 7-8mm thick, as in floors set and jointed in neat cement slurry and pointed in white cement with pigments to match over and including the provision of 15 mm thick bedding layer in cement mortar 1:4, complete all as specified and as directed. | | 15 | Sqm |
|---|
| 42 | 42 | Glazed ceramic coloured tiles 300mm x 200mm, 6-7mm thick in vertical surfaces, set and jointed in neat cement slurry and pointed in coloured cement to match tiles over 10mm thick backing coat in cement mortar 1:4, complete all as specified and as directed. | | 60 | Sqm |
|---|
| 43 | 43 | Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement, complete all as specified and as directed. | | 1600 | Sqm |
|---|
| 44 | 44 | Preparing newly plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and as directed. | | 1600 | Sqm |
|---|
| 45 | 45 | Preparation of old decorated surfaces of walls and applying one coat of cement base paint, complete all as specified and as directed. | | 1000 | Sqm |
|---|
| 46 | 46 | Preparation of new steel or iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint ordinary tint over a coat of red oxide zinc chrome primer, complete all as specified and as directed. | | 100 | Sqm |
|---|
| 47 | 47 | Cutting chases for concealed water tubing girth exceeding 10cm but not exceeding 20cm girth and making good in cement mortar 1:3 in brick walls, complete all as specified and as directed. | | 80 | RM |
|---|
| 48 | 48 | 15mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs including taking down old tubing, complete all as specified and as directed. | | 70 | RM |
|---|
| 49 | 49 | All as per description of Srl item No.- 48 here-in-before but fixing only, complete all as specified and as directed. | | 15 | RM |
|---|
| 50 | 50 | 20mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs including taking down old tubing, complete all as specified and as directed. | | 30 | RM |
|---|
| 51 | 51 | All as per description of Srl item No.- 50 here-in-before but fixing only, complete all as specified and as directed. | | 10 | RM |
|---|
| 52 | 52 | 40mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs including taking down old tubing, complete all as specified and as directed. | | 30 | RM |
|---|
| 53 | 53 | Sand cast iron soil waste and vent pipes 100mm dia, in any length, with cement joints, laid in trenches/floors, fixed to walls with CI/MS holder bat clamps and conforming to IS-1729, complete all as specified and as directed. | | 200 | RM |
|---|
| 54 | 54 | Sand cast iron soil waste and vent pipes 75mm dia, in any length, with cement joints, laid in trenches/floors, fixed to walls with CI/MS holder bat clamps and conforming to IS-1729, complete all as specified and as directed. | | 30 | RM |
|---|
| 55 | 55 | CI bend for 100mm bore any radius, diminishing pieces or tapers (larger bore measured), fixed to walls, complete all as specified and as directed. | | 30 | Each |
|---|
| 56 | 56 | CI bend for 75mm bore any radius, diminishing pieces or tapers (larger bore measured), fixed to walls, complete all as specified and as directed. | | 20 | Each |
|---|
| 57 | 57 | 100mm bore cast iron sanitay connection 'S' branch, with branch 370 to 450mm long excluding joint, complete all as specified and as directed. | | 10 | Each |
|---|
| 58 | 58 | 100mm bore cast iron sanitay connection 'P' branch, with branch 375 to 450mm long excluding joint, complete all as specified and as directed. | | 60 | Each |
|---|
| 59 | 59 | CI floor trap, with grating including jointing to 100mm bore waste pipe fixed in cement concrete 1:2:4, type B-1, complete all as specified and as directed. | | 32 | Each |
|---|
| 60 | 60 | CI floor trap, with grating including jointing to 75mm bore waste pipe fixed in cement concrete 1:2:4, type B-1, complete all as specified and as directed. | | 15 | Each |
|---|
| 61 | 61 | CI vent cowl of 75mm bore, complete all as specified and as directed. | | 40 | Each |
|---|
| 62 | 62 | CI oval access door covers for 100mm dia cast iron pipe fittings, fixed in any position, complete all as specified and as directed. | | 80 | Each |
|---|
| 63 | 63 | 100mm bore stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including securing ends of stays to wall or roof, fixed in repairs, complete all as specified and as directed. | | 50 | Each |
|---|
| 64 | 64 | 75mm bore stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including securing ends of stays to wall or roof, fixed in repairs, complete all as specified and as directed. | | 10 | Each |
|---|
| 65 | 65 | PVC 110mm bore (SWR) pipes single socketed, in any length with rubber ring joints, flaid in trenches or in floors, complete all as specified and as directed. | | 120 | RM |
|---|
| 66 | 66 | PVC 75mm bore (SWR) pipes single socketed, in any length with rubber ring joints, flaid in trenches or in floors, complete all as specified and as directed. | | 30 | RM |
|---|
| 67 | 67 | PVC (SWR) bend of 110mm bore any radius, complete all as specified and as directed. | | 35 | Each |
|---|
| 68 | 68 | PVC (SWR) bend of 75mm bore any radius, complete all as specified and as directed. | | 20 | Each |
|---|
| 69 | 69 | Cutting into existing manholes including cuttng out existing benching for connecting new drains and forming branch channel (1/2 or 3/4 section), making good to pipe in cement concrete 1:2:4 type B-1 and finished smooth and reforming benching as required for 150mm dia pipe, complete all as specified and as directed. | | 10 | Each Job |
|---|
| 70 | 70 | Cutting into existing manholes including cuttng out existing benching for connecting new drains and forming branch channel (1/2 or 3/4 section), making good to pipe in cement concrete 1:2:4 type B-1 and finished smooth and reforming benching as required for 200mm dia pipe, complete all as specified and as directed. | | 3 | Each Job |
|---|
| 71 | 71 | Cement concrete type D-2 1:4:8 (using 40 mm graded crushed stone aggregate) in bed to drain pipe 150 mm dia including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed. | | 320 | RM |
|---|
| 72 | 72 | Cement concrete type D-2 1:4:8 (using 40 mm graded crushed stone aggregate) in bed to drain pipe 200 mm dia including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed. | | 60 | RM |
|---|
| 73 | 73 | SGSW pipe 150 mm dia including jointing with cmenet mortar, complete all as specified and directed. | | 300 | RM |
|---|
| 74 | 74 | SGSW pipe 200 mm dia including jointing with cmenet mortar, complete all as specified and directed. | | 55 | RM |
|---|
| 75 | 75 | Factory made steel fibre reinforced(SFRC) man hole covers with frame including necessary hold fast/lugs for embedding (medium duty) 560mm dia or redctangular of equivalent area conforming to IS-12592, complete all as specified and as directed. | | 90 | Each |
|---|
| 76 | 76 | Factory made steel fibre reinforced(SFRC) man hole covers only (medium duty) 560mm dia or redctangular of equivalent area conforming to IS-12592, complete all as specified and as directed. | | 40 | Each |
|---|
| 77 | 77 | Vitreous china wash down water closet pan (pedestal pattern) excluding flushing cistern and flush pipe, including fixing of water closet complete with plastic water closet seat black/white closed pattern witrh flat bottom and cover and mild steel chromium plated or aluminised hinging device, fixed in repairs, complete all as specified and as directed. | | 15 | Each |
|---|
| 78 | 78 | Viterous China water closet squatting pan, 'Orrisa' pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete including connectoin to trap, and to flushing pipe, anti syphonage pipe etc. including trap set in and including concrete and making good to floors, fixed in repairs, complete all as specified and as directed. | | 10 | Each |
|---|
| 79 | 79 | PVC 10 Ltrs valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with flush pipe etc. ISI approved, fixed in repairs, complete all as specified and as directed. | | 40 | Each |
|---|
| 80 | 80 | Plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, fixed in repairs, complete all as specified and as directed. | | 60 | Each |
|---|
| 81 | 81 | Vitreous china wash basin under counter oval type size 560x450x175mm, fixed in repairs, Make :- Cera,jaquar, Hindware or eqvilent under granite slab with all fitting and fixture, fixed in repairs, complete all as specified and as directed. | | 10 | Each |
|---|
| 82 | 82 | 15mm bore brass CP basin mixer for mixing hot and cold water fixed as per manufacture's mannual, with long shunk and cup washers, screwed both ends for iron pipes or for unions, fixed in repairs, complete all as specified and as directed. Make :- Cera Cat Part No F3001461/Somany Cat Part No 220912/ Hindware-Cat Part No. F330014CP | | 10 | Each |
|---|
| 83 | 83 | PVC connections 450mm long, 15 mm size with brass chromium plated nuts at ends, fixed in repair, complete all as specified and as directed. | | 80 | Each |
|---|
| 84 | 84 | PVC connections 600mm long, 15 mm size with brass chromium plated nuts at ends, fixed in repair, complete all as specified and as directed. | | 50 | Each |
|---|
| 85 | 85 | Health faucet chromium plated brass with 1.00m CP long flexible pipe and brass chromium plate nuts, fixed in repairs, complete all as specified and as directed. Make - Cera Cat Part No. F- 8030103 or equavalent in Hindware/Somany/Jaquar | | 120 | Each |
|---|
| 86 | 86 | Brass spindle suitable for 15mm Bib tap/Pillar Tab with fibre washer & screw, fixed in repairs, complete all as specified and as directed. | | 400 | Each |
|---|
| 87 | 87 | 15mm bore brass chromium sink mixer of mixing 'Hot' and 'Cold' water, with swinging point screwed down for iron pipe, fixed in repairs, complete all as specified and as directed. Make :- Somany Cat No 200360061/Hindware Cat No 200023CP/Cera Cat No F3002581 | | 10 | Each |
|---|
| 88 | 88 | Looking mirror size 600x450mm mounted on 6mm thick PVC sheet and aluminium frame all around incl fix with necessary fixing arrangement, complete all as specified and as directed. | | 10 | Each |
|---|
| 89 | 89 | Fancy type Bib tap CP with crutch or butter fly handle, 15mm bore complete to GI pipe, fixed in repairs complete all as specified and as directed. | | 25 | Each |
|---|
| 90 | 90 | Cast copper alloy chromium plated angle cock, of 15 mm bore, fixed in repairs, complete all as specified and as directed. ( Make - Jaquar Cat Part No - FLR5053 N / Cera Cat Part No. F 20 02201 or equivalent in Somany/Hindware. | | 20 | Each |
|---|
| 91 | 91 | Mechanically operated 25 tonne truck mounted desludger with 12000Ltr capacity tanker having water fitted high pressure jet machine for cleaning and desludging of sewage line, shall be used by the contractor as per scheduled programme in writing and completion of each job to the entire satisfaction of Engineer-in-Charge as instructed. ( NOTE : a) Per day means 8 working hours in a day excluding stand by period due to any sort of reason. b) In case contractor fails to deploy the machine as per scheduled programme a recovery of Rs 2000/- per day shall be deducted from his payment.) | | 10 | PER DAY |
|---|
| 92 | 92 | Cleaning of sewage system including WCs, WHB, bottle traps, nahani and floor traps, soil/waste pipe running on external walls of building including junctions, manholes of any description and sewage lines of all sizes upto the final drop out let into septic tank/soak well of central sewage without distrubing its running/flowing and removing all type of blockages in any situation by mechanical means or manually and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed by the Engineer-in-Charge. | | 11 | PER MONTH |
|---|
| 93 | 93 | NOTE: a) The above task shall be caried out by deploying 04 safaiwalas on all days including Sundays and Holidays between 0900 Hrs to 1700Hrs, Two numbers for each pocket of (i) Baird Place- 02 Nos. (ii) Polo Road and Prade Road- 02 Nos. b) One mechanical pump diesel/petrol for dewatering sludge water, safety belt, ladder, gloves gasmask, bucket to remove sludge, mechnical device required to reach work at difficult locations shall be made available all time at site to ensure heigene and sanitation during work. c) Daily attendance shall be maintained in the Attendance Register by the JE concerned and a recovery for absent period shall be made @ Rs 500/- per person per day. All relevent record shall be maintained by the contractor and to be submitted before making any payment duly signed by Engineer-in-Charge & JE concerned. d) Work will be carried out in Multistoreyed Building upto 08 storeys and Jula arrangement including all safety measures are to be provided by the contractor under his own arrangement, rate of which are deemed to be included in the rates quoted against above mentioned item. | | | |
|---|
| 94 | 94 | Breaking up drain pipes (SGSW/AC/RCC) of any size by puncturing, cleaning of blockage by roding and making good of broken/punctured portion of pipes by changing of drain pipes (SGSW/AC/RCC) and sealing the joints with cement mortar 1:3 or PCC 1:2:4 type B-1 for no leakage including necessary earth work, excavation in any type of soil upto any depth, returning filling and removal of surplus soil to a distance not exc 50 mtr from the starting point, complete all as specified and as directed by Engineer-in-Charge. | | 50 | Each |
|---|
| 95 | 95 | CI fittings such as Tees, bends, branch pieces, floor traps etc., upto 100mm dia (waste water/rain water/soil waste pipe) where ever required to stop leakage including testing of leakage upto eight storied building, fixed in repairs, complete all as specified and as directed. Note :- The necessary steel scaffolding upto eight storeyed whereever required to complete the job shall be provided by the contractor with all safety equipments and the rate for scaffolding & safty equipments shall be deemed to be included in the quotted rates by the contractor and nothing extra shall be paid on this account. | | 20 | Each Job |
|---|
| 96 | 96 | PVC/UPVC fittings such as Tees, bends, branch pieces, floor traps etc., upto 100mm dia (waste water/rain water/soil waste pipe) where ever required to stop leakage including testing of leakage upto eight storied building, fixed in repairs, complete all as specified and as directed. Note :- The necessary steel scaffolding upto eight storeyed whereever required to complete the job shall be provided by the contractor with all safety equipments and the rate for scaffolding & safty equipments shall be deemed to be included in the quotted rates by the contractor and nothing extra shall be paid on this account. | | 15 | Each Job |
|---|
| 97 | 97 | Racking out cement/lead joints of CI pipes 100mm/75mm dia and filling with lead joints/neat cement mortar to stop leakage of joints, complete all as specified and as directed by Engineer-in-Charge. | | 20 | Each |
|---|
| 98 | 98 | Cleaning of Manholes exceeding 1.5mtr deep and not exceeding 3.00mtr deep including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the septic tank including and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed by Engineer-in-Charge. | | 36 | Each |
|---|
| 99 | 99 | Cleaning of 10 users septic tank including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the septic tank including and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed by Engineer-in-Charge. | | 8 | Each |
|---|
| 100 | 100 | Cleaning of 25 users septic tank including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the septic tank including and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed by Engineer-in-Charge. | | 28 | Each |
|---|
| 101 | 101 | Cleaning of 50 users septic tank including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the septic tank including and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed by Engineer-in-Charge. | | 5 | Each |
|---|
| 102 | 102 | Cleaning of 100 users septic tank including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the septic tank including and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed by Engineer-in-Charge. | | 2 | Each |
|---|
| 103 | 103 | Dewatering of soak wells, sump wells including bailing out water from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the same including and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed. | | 135 | Cum |
|---|
| 104 | 104 | Removing of rubbish, mud, surbs, vegitation etc from existing drain including removing and replacing of covers, cleaning to make the drain serviceable completely including removing the taking out materials to a distance exc 50mtr or in suitable location complete all as specified and as directed. | | 95 | Cum |
|---|
| 105 | 105 | NOTE:- For minimum fair wages, EPF and payment to labour employed, refer Sch A Note No-14,15 and Special Condition No 5 & 21.2 of this tender. Contractor must produce all the relevent record such as payment made to labour, EPF etc at the time of payment of RARs/Final bill. No payment will be released to contrator without producing the proper record. | | | |
|---|
| 106 | 106 | NOTE:- Irrespective of whatever specified elsewhere in tender documents, all the debris/waste materials produced out of above mentioned work shall be removed out of Cantonement land and disposed off at locations notified by the Delhi Cantonment Board for disposal of waste building materials within NCR area, without any extra cost to Department under own arrangement of contractors. The rates quoted by the contractors against the items catered here-in-above in the BOQ are inclusive of said provision. | | | |
|---|