Indian Oil Corporation Limited-IOCL has published Design, Supply, Installation, Testing And Commissioning Of Terminal Automation System Comprising Of Tank Truck Loading System, Tank Farm Management System, Fire Alarm System, Hydrocarbon Vapours Detection System, Fire Fighting Automation System Etc Along . Submission Date for this Tender is 11-10-2019. Application Software Tenders in MIRAJ DEPOT Maharashtra. Bidders can get complete Tender details and download the document.
Name of Work: Design, supply, installation, testing and commissioning of Terminal Automation System comprising of Tank Truck Loading System, Tank Farm Management System, Fire Alarm System, Hydrocarbon Vapours Detection System, Fire Fighting Automation System etc along with associated works at Miraj Depot, Maharashtra. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 20 | TANK LORRY FILLING | 1 | ||
2 | 30 | Supply of intrinsically safe / flameproof type proximity card reader alongwith mounting accessories etc complete as per specifications for mounting at | 2 | ||
3 | 40 | Security Entry & Exit barrier gates ( 1 no. Per barrier Gate) | 3 | 2 | EA |
4 | 50 | Near Security Gate ( for TT registration ) | 4 | 2 | EA |
5 | 60 | Supply of Scratch proof, waterproof Smart cards along with messages printed compatible with proximity card reader complete as per specifications and tender document. | 5 | 500 | EA |
6 | 70 | Supply of 6M barrier gates along with accessories, controllers etc complete as per specification and tender document for installation at following location. | 6 | ||
7 | 80 | License area Entry gate | 7 | 1 | SET |
8 | 90 | License area Exit gate | 8 | 1 | SET |
9 | 100 | Security Entry & Exit gates | 9 | 2 | SET |
10 | 110 | Supply of barrier gate traffic lamps (Red, Amber & Greeen LED Cluster type) along with Standpost of suitable height, foundation, mounting structure accessories etc complete as per specification and tender document | 10 | 4 | SET |
11 | 120 | Supply of 1no. manual operated DBBV and 2 nos. of 80 NB, full bore, zero leakage, fire safe ball valves alongwith associated piping, Tee connection, gaskets, copper jumpers, fasteners, blind flanges at one end of each ball valves, pipe fittings, SOR flanges etc for each loading point assembly for making arrangement to connect Mobile master meter for proving of TLF PD meter complete as per specifications and tender documents. | 11 | 14 | SET |
12 | 130 | Supply of top loading arm of size 80 mm NB along with 1 no. full bore isolation ball valve (100 mm) ,vacuum breaker with associated pipintg for loading arm with the metering skid , Stand post & mounting structure, bonding clip (for bonding of loading arm with TT) etc complete as per specifications and tender document. \nApplication: MS/HSD | 12 | 7 | EA |
13 | 140 | DISPLAY BOARDS | 13 | ||
14 | 150 | Supply of weather proof LED bay queuing display board (Minimmum 15 lines x 100 mm Character height x 25 characters per line) for outdoor application at TT parking area or any other designated place as per site engineer along with accessories like public address system, speakers, amplifer, mike, structral steel for mounting of the same, canopy/sunshade etc complete as per specifications and tender document. | 14 | 1 | EA |
15 | 160 | Supply of LED monitor of minimum 42" along with required hardware and software for interfacing with TAS, lockable enclosure (wall mounted) for mounting the monitor alongwith accessories, canopy/ sunshade etc for displaying the list of TTs whose invoice has been generated and TT is still inside license area complete in all respect as per tender requirement. Kindly note, no additional payment shall be made for any additional hardware/ software/ cable etc required for integration of the monitor with TAS. | 15 | 1 | EA |
16 | 170 | Supply of weather proof Single line LED display board (Minimmum 1 line x 25 mm Character height x 11 characters per line) for outdoor application near Security Gate/ TT parking Area along with mounting accessories, canopy/ sunshade etc complete as per specifications and tender document for displaying the TT Registration no. bilingual (English + local language) of reported TT whose proximity card has been shown on the PCR adjacent to the display board for TT reporting. | 16 | 2 | EA |
17 | 180 | Supply of weather proof Single line coloured LED display board with scroll and flash effects (Minimmum 1 line x 50 mm Character height x 10 characters per line) for outdoor application near license area Entry barrier Gate along with mounting structure, canopy/ sunshade, accessories etc complete as per specifications and tender document for displaying the bay no. (Bilingual) etc of the authorised TT reported at license area Entry Gate as per FDR.\n(2 nos. per License Area Entry Barrier Gate) | 17 | 2 | EA |
18 | 190 | Supply of single phase FLP socket with cover at alternate bay alongwith mounting accessories for powering Mobile Master METER ASSEMBLY complete as per specifications and tender documents. | 18 | 4 | EA |
19 | 200 | Ethanol Dosing System | 19 | ||
20 | 210 | Supply of double Case Positive Displacement Meter of size 50 mm with Pulse Transmitter in Flameproof and Weather Proof (IP 65) enclosure complete as per specifications for MS/HSD/SKO/ATF use | 20 | 2 | EA |
21 | 220 | Supply of Strainer cum Air eliminator for line size 50 mm alongwith differential pressure transmitter across the Strainer Cum Air Eliminator along with accessories, SS tubing, needle valves etc complete as per specifications and tender document. | 21 | 2 | EA |
22 | 230 | Supply of multistage Diaphragm type Digital Control Valve of size 50 mm along with provision for locking arrangement for solenoid valves as per specification. | 22 | 2 | EA |
23 | 240 | Supply of Diaphragm type, hydraulically operated, electrically actuated, solenoid operated ON-OFF Valve alongwith accessories etc for line size 50 mm complete as per specifications and tender document. \n | 23 | 2 | EA |
24 | 250 | Supply of 1no. manual operated DBBV and 2 nos. of 50 NB, full bore, zero leakage, fire safe ball valves alongwith associated piping, Tee connection, gaskets, copper jumpers, fasteners, blind flanges at one end of each ball valves, pipe fittings, SOR flanges etc for each loading point assembly for making arrangement to connect Mobile master meter for proving of TLF PD meter complete as per specifications and tender documents. | 24 | 6 | SET |
25 | 260 | TLF Header line instruments | 25 | ||
26 | 270 | Supply of flameproof cum weather proof, min SIL 2 smart pressure transmitter with display unit, SS manifold,1 no isolation ball valve, canopy/sunshade with mounting accessories etc on the TLF main header line complete as per specifications and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) (Range 0-15 kg/cm2) | 26 | 3 | EA |
27 | 280 | Tank Farm Management System | 27 | ||
28 | 290 | Supply of minimum SIL 2 certified Non - contact type Radar level gauges with instrument accuracy of +/- 1 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 28 | ||
29 | 300 | For Cone Roof Vertical tanks (Primary and Secondary Radar Gauges - HSD-9x2) | 29 | 18 | EA |
30 | 310 | For Internal Floating Roof Vertical tanks (Primary and Secondary Radar Gauges - MS-4x2) | 30 | 8 | EA |
31 | 320 | For underground horizontal product tanks (Ethanol - 2 no.) | 31 | 2 | EA |
32 | 330 | Supply of multi point temperature averaging sensor with integrated water interface probe (MSTW) along with mounting accessories etc complete as per specification and tender document. | 32 | ||
33 | 340 | With minimum 8 elements temperature sensor (for above ground tanks - MS, HSD, SKO) | 33 | 13 | EA |
34 | 350 | With minimum 2 elements temperature sensor (for U/G horizontal tanks - Ethanol -2 no.) | 34 | 2 | EA |
35 | 360 | Supply of Density probe along with accessories etc for density measurement of the product in product tanks complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 35 | ||
36 | 370 | For A/G Tanks with 3 elements | 36 | 13 | EA |
37 | 380 | For U/G Tanks with 1 elements | 37 | 2 | EA |
38 | 390 | Supply of Tank Side indicator along with mounting accesories etc complete as per specification and tender document for displaying respective tank inventory data. (TSI will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 38 | ||
39 | 400 | For Vertical Product tanks - (Primary & Secondary Radar Gauges) | 39 | 26 | EA |
40 | 410 | For U/G Product tanks - Primary Radar Gauge (2 nos.) | 40 | 2 | EA |
41 | 420 | For Water Tanks (3 nos) | 41 | 3 | EA |
42 | 430 | Supply of top mounted minimum SIL2 certified Overfill detector (vibrating fork type) of suitable probe length along with mounting accessories, spool piece of minimum 500mm, proof testing equipment, etc complete as per specification and tender document | 42 | ||
43 | 440 | For U/G Product tanks | 43 | 2 | EA |
44 | 450 | Supply of parallel redundant Communication Interface Units (CIU) including all accessories etc for tank farm management system complete as per specification and tender document. | 44 | ||
45 | 460 | For Primary Radar gauges, Radar Gauges installed in under ground tank, water tank & Sludge tank | 45 | 1 | SET |
46 | 470 | For Secondary Radar Gauges | 46 | 1 | SET |
47 | 480 | Supply of 2 Nos. of TFMS Server (19" Rack mounting type ) along with 1 No. 19" rack mounted industrial monitor keyboard drawer, optical mouse, 4 port industrial grade KVM switch, Licensed OS (latest supported by TFMS software), Licenced Antivirus, Licenced latest MS Office professional, TFMS licensed software from Radar Gauge OEM etc complete as per specification and tender document. \n | 47 | 1 | SET |
48 | 490 | Supply of TFMS Workstation with minimum 23" LED colour monitor, standard keyboard, mouse, Licensed OS(latest supported by TFMS software), Licenced Antivirus, Licenced latest MS Office proffestional, TFMS licensed client software from same Radar Gauge OEM etc complete as per specification and tender document. \n | 48 | ||
49 | 500 | 19" Rack mounting type at Control Room | 49 | 1 | EA |
50 | 510 | Tower type at TM's room | 50 | 1 | EA |
51 | 520 | ESD PUSH BUTTON STATION | 51 | ||
52 | 530 | Supply of Exd/FLP ESD push button stations, mushroom head type, with protection cover to avoid accidental activation alongwith mounting structure complete as per specification and tender document. | 52 | ||
53 | 540 | Local ESD Push Button Station ( Each Battery of TLF - 1 nos.) | 53 | 1 | EA |
54 | 550 | Plant ESD Push Button Station ( Each battery of TLF - 1 nos.) | 54 | 1 | EA |
55 | 560 | Plant ESD Push Button Station (At TLF and TWD pump house) | 55 | 2 | EA |
56 | 570 | Supply of ESD push button stations (for indoor application), mushroom head type with protection cover to avoid accidental activation alongwith mounting structure complete as per specification and tender document. (control room - 1 no., security room - 1 no., TM's cabin - 1 no.) | 56 | 3 | EA |
57 | 580 | Control Room equipments | 57 | ||
58 | 590 | Supply of Triple / Quadruple Modular Redundant, SIL 3 TUV/ EXIDA certified Safety PLC along with PLC Panels, Marshalling Panels, Biometric fingerprint cum contactless smart card reader with accessories, limit switches, Dual redundant Input Output modules, Power supply units, Relays with base, barriers, TBs, Dual Ethernet ports per processor, Serial Interface Modules, HMI , wirings, glands, plugs, other modules/ hardwares required for interfacing all the required field and control room equipments including spare requirements, licenses, tags, GUI, licensed OPC compliant software etc complete as per specification and tender document.\n | 58 | 1 | SET |
59 | 600 | Supply of two nos. of Load Rack Computers (LRC Servers ) rack based along with High availability redunancy software & working on redundant (Primary and Secondary) hot standby mode , 19" rack mounted industrial monitor keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, SQL, oracle, RDBMS (license copy) etc complete as per specifications and Tender Document. \n OR\nSupply of Load Rack Computer (LRC Server - Dual Mode Redundant Grade with built in redundancy) Rack mounted alongwith 9" rack mounted industrial monitor keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, SQL, oracle, RDBMS (license copy) etc complete as per specifications and Tender Document. \n\nLRC system solution shall have either of the above mentioned configuration meeting the complete specification and tender requirements. \n\nIn addition, the LRC system shall be configured to have Zero Downtime to repair, Full data redundancy shall be provided using proven technology , it shall also provide port level redundancy.The system solution shall be capable of self fault detection and isolation, all necessary hardware/software configuration etc to achieve the same shall be included.\n\n\n\n | 59 | 1 | LOT |
60 | 610 | Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, terminal blocks and wiring etc complete as per specification and tender document for mounting of below mentioned equipments | 60 | ||
61 | 620 | For mounting of LRC Server along with associated rack mounted monitors, rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking & OFC components, terminal server, Ethernet switch, GSM modems MCBs etc as per specification and tender document | 61 | 1 | LS |
62 | 630 | For mounting of TFMS Server along with associated rack mounted monitors, rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking & OFC components, CIUs MCBs etc as per specification and tender document | 62 | 1 | LS |
63 | 640 | For mounting of Rack mounted Master Control Stations (4 sets of redundant MCS) for MOVs & DBBVs along with power adaptors, MCBs, required accessories etc as per specification and tender document | 63 | 1 | LS |
64 | 650 | Supply of Complete Terminal Automation Software for LRCS and Operator work Stations with dongle/key, licenses, media, documentation, including equipment fault detection module / software etc complete as per specifications and tender documents. Vendor to provide the complete software to meet the Terminal Automation System as per tender scope of work and requirements. \n\nTAS software shall be interfaced with following but not limited to major sub-systems / equipments alongwith GUI development for monitoring, logging, reporting and controls-interlocks etc as per specification and tender document.\n\n | 64 | 1 | LS |
65 | 660 | \n- Safety PLC, Process PLC\n- TLF Automation System ( BCU, PD meter, Barrier Gates, Bay Queue Display, TT registration and entry System, Bay allocation Display, Invoice generated display, Additive Dosing system, Ethanol blending System, rack monitors etc)\n- Valve Automation System (ROSOVs, MOVs, DBBV, MCS Interface, SOVs, etc)\n- Tank Farm Management System ( Primary & Secondary Radar Gauging, AOPS, PTs, DPT, LS, Density probes, MSTW, CIU etc)\n- Pipeline/ Refinery PLC Interface, OMC PLC interface\n- MCC, Pump, Borewell, DG Sets, Air compressors, UPS interface, VFDs\n- PAGA Interface \n- HC Detection System Interface\n- FAS Interface, Fire Fighting System, HVLR, Fire Alarm System Interface, Fire Engines, DG Set, Jockey pumps, Foam pumps etc\n- VRU Package Units\n-Effluent Treatment plant\n- CCTV systems\n- Access Control System\n- SKO Blue Dye Dosing System\n- SAP-TAS, SAP-TFMS, TT planning interface ((TT Loading, WB , Tanker/ Ship/ Barge in-line with protocol & sub systems covered in the work)\n- ESD System, Emergency panel, Power ESD, Local ESD\n- Power distribution boards, UPS, OIC, EWS, TTES, etc\n- Any other Third Party Interface/ devices as per scope of the work order etc | 65 | ||
66 | 670 | Supply of Operator Interface Console Computer (OIC) minimum 23" color LED monitor, standard keyboard, mouse, client software, SCADA, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. | 66 | ||
67 | 680 | 19" Rack mounted type in Control Room ( 2 OICs, 1 for alarm Display, 1 for fire fighting System) | 67 | 4 | EA |
68 | 690 | Tower mounted type in TM's Cabin and Invoice Room ( 1 no. OIC in TM cabin, 1 no. OIC In Invoice room) | 68 | 2 | Ea |
69 | 700 | Supply of Engineering Workstation (EWS) with minimum 23" colour LED monitor, standard keyboard, mouse, client software, SCADA,OS, Antivirus, MS office professional etc. complete as per specifications and tender document. (Locations: 1 no. in CR for both Process and Safety PLC) - Rack Mounted type | 69 | 1 | EA |
70 | 710 | Supply of Tank Truck Entry System (TTES) Workstation with minimum 23" colour LED monitor, standard keyboard, mouse, TTES software, SCADA, OS, Antivirus etc. complete as per specifications and tender document. (Locations: 2 nos. in S&D + 1 no. in Control room) | 70 | ||
71 | 720 | Tower mounted type in S&D | 71 | 2 | EA |
72 | 730 | Supply of Terminal servers (rack mounted) alongwith accessories and inbuilt/externally mounted lightening and Surge Protection Device Type (1+2) connected to serial port for interfacing field units such as PD meters, card readers, Bay Queue display units (Indoor & outdoor), Single line Display unit for TT reporting and Bay allocation, UPS, DG sets any other third party interface etc with LRCS/TAS complete as per specification and tender document. \nNote: Terminal Server to be configured in Dual Redundant mode. | 72 | ||
73 | 740 | 32 ports at Control Room | 73 | 2 | EA |
74 | 750 | 16 ports at S&D | 74 | 2 | EA |
75 | 760 | Supply of 24 ports Layer 3 Industrial Grade Managed Ethernet Switches - (rack mounted) (10/100/1000 MBPS) along with SFP, copper, fiber modules, accessories for connecting LRCS, process PLC, safety PLC, BCUs, CCTV, ACS, OIC, TFMS, TTES, printers, IOCL LAN (SAP) and other TAS equipment as per system architecture and design requirement complete as per specification and tender document.\nNote:\n1. The switches are to be configured in Dual Redundant mode.\n2. OFC ports to be provided for connecting interbuilding LANs, BCUs and any other equipment which are to be connected to above switch and the communication is through OFC cable. | 75 | 2 | Ea |
76 | 770 | Supply of minimum 10 ports ( 8 nos. copper ports and 2 nos optical ports) Layer 2 Industrial grade Managed Ethernet Switches (rack mounted) along with accessories for connecting BCU with TAS, equipments installed in S&D room, Lock room, Security room, Terminal Manager room and other TAS equipments as per system architecture and design requirement complete as per specification and tender document. \n\nNote: \n1. Ethernet switches for BCU communication shall have suitable mounting arrangement to mount inside FLP JBs. \n2. The switches are to be configured in Dual Redundant mode.\n3. In case BCU has only one Ethernet port, then for redundant communication vendor has to provide additional Industrial Grade Terminal Server / Gateway for Serial to Ethernet conversion at field and connect the same to the redundant Ethernet switch at no additional cost to IOCL.\n | 76 | ||
77 | 780 | For BCU integration at TLF & TT Calibration shed (copper ports of 10/100 MBPS) | 77 | 8 | EA |
78 | 790 | At Lock Shed (copper ports of 10/100/1000 MBPS) | 78 | 1 | EA |
79 | 800 | At Admin Building (TM cabin) (copper ports of 10/100/1000 MBPS) | 79 | 1 | EA |
80 | 810 | At S&D Room (copper ports of 10/100/1000 MBPS) | 80 | 1 | EA |
81 | 820 | At Security Room (copper ports of 10/100/1000 MBPS) | 81 | 1 | EA |
82 | 830 | Supply of Layer 2 Managed Ethernet Switches (rack mounted) along with SFP, copper, fiber modules, accessories, etc for IOCL LAN network complete as per specification and tender document. | 82 | ||
83 | 840 | 24 ports ( 8 optical & 16 Copper ports) - at S&D Building | 83 | 1 | EA |
84 | 850 | 24 ports ( 2 optical & 22 Copper ports) - at Admin Building | 84 | 1 | EA |
85 | 860 | 24 ports ( 2 optical & 22 Copper ports) - at Control Room | 85 | 1 | EA |
86 | 870 | 8 ports ( 2 optical & 6 Copper ports) - at Invoice Room | 86 | 1 | EA |
87 | 880 | 16 ports ( 2 optical & 14Copper ports) - at QC Lab | 87 | 1 | EA |
88 | 890 | Supply of Wall mounted Network Rack-minimum 10U 19" Rack for mounting of Terminal Server/Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at Security Room, TM room, Invoice Room, S&D for TAS equipments | 88 | 2 | EA |
89 | 900 | Supply of 19" Network Rack of suitable sizes for mounting of Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at S&D, Admin building, Control Room, Invoice room & S&D of IOCL LAN network. | 89 | 1 | LS |
90 | 910 | Supply of Monochrome Laser Printer along with accessories for TAS and TFMS report printing in control room (2 nos.) and 2 nos. at security room complete as per specifications and tender document. | 90 | 2 | EA |
91 | 920 | Supply of heavy duty high speed line matrix network printer (min. 500 LPM) along with print server , Printer Stand (open pedestal type) and accessories for invoice printing in lock shed room, complete as per specifications and tender document. \nNote: Incase Network printer is not available, suitable converter/ print server to be provided for putting the printer on network.\n | 91 | 2 | EA |
92 | 930 | Supply of Open desk operator consoles, chairs, printer tables etc complete as per specification and tender document. | 92 | ||
93 | 940 | Open desk operator consoles for mounting of 2 nos. of 19" Rack mounted CPU, 2 nos. of key boards, 2 nos. of mouse, 2 nos. of monitor in two tiers , etc complete as per specification and tender document.\n\n(For mounting of 2 nos. OICs, 1 no. Alarm Display OIC, 1 no. Fire fighting OIC, 1 no. TTES, 1 TFMS workstation, 1 no. CCTV client, 1 no. Acess control Server, 1 no. EWS) | 93 | 4 | EA |
94 | 950 | Chairs (Godrej PCH 5002T or equivalent) | 94 | 4 | EA |
95 | 960 | Standard Printer Tables of Godrej or equivalent make (2 nos. in control room, 2 nos. at security gate, 1 no. in security room for visitor management) | 95 | 5 | EA |
96 | 970 | Standard Computer Table of Godrej or equivalent make for installation of OIC, TFMS client PC and CCTV client PC in TM room (3nos.), CCTV client PC, ACS server in security room (2nos.), TTES in S&D room (2nos.) and OIC in lock shed room (1 no.) | 96 | 2 | EA |
97 | 980 | Supply of Redundant GSM modem (Industrial grade, IP based) along with accessories for auto SMS as per specification and tender document. | 97 | 1 | Set |
98 | 990 | Supply of minimum 40" HD LED monitor along with 1 no. of hooter, mounting accessories, cables etc for critical alarms display & annuciation (1no.) and Fire fighting system display (1 no.) complete as per specifications and tender document. | 98 | 2 | EA |
99 | 1000 | Automatic Fire Detection and Alarm System | 99 | ||
100 | 1010 | Supply of microprocessor based automatic Fire Alarm Panel along with required Software, and hardwares like Control module, monitor module, fault isolation module ( in built/ External), Mimic panel, mounting structure support etc complete as per standard design engineering, specification and tender document. \nLocation : Control Room & Admin Building\nFire Detection System shall be interfaced with TAS for GUI & Alarm, event monitoring, recording & printing as mentioned in tender document.\nScope also includes the Demonstration of System to Safety, Operations & Engineering team from user and OISD & Statutory audit & periodic testing. | 100 | 2 | EA |
101 | 1020 | Supply of Repeater Panel along with software, hardware, mimic panel, mounting accessories etc required as per standard design Engineer, specifications and tender document complete in all respect. \n(Tentative location : Security Gate - 1 no., Fire Pump House - 1 no.) | 101 | 2 | EA |
102 | 1030 | Supply of addressable type detectors along with accessories, fault isolation module (Inbuilt/ External), structural supports etc required as per standard design engineering, specification and tender document complete in all respect. | 102 | ||
103 | 1040 | Combination/Multisensor Detector | 103 | 15 | EA |
104 | 1050 | Supply of Manual Call Point along with accessories, fault isolation module (Inbuilt/ External) and structural supports etc required as per standard design engineering, specification and tender document complete in all respect. | 104 | ||
105 | 1060 | Ex-proof and weather proof MCP | 105 | 8 | EA |
106 | 1070 | Weather proof MCP | 106 | 3 | EA |
107 | 1080 | Supply of Hooter along with accessories, fault isolation module (inbuilt/ External), structural supports etc required as per standard design engineering, specification and tender document complete in all respect. | 107 | ||
108 | 1090 | Weather proof Hooter | 108 | 5 | EA |
109 | 1100 | Supply of Response Indicator along with accessories, mounting structure etc required as per standard design engineering, specification and tender document complete in all respect. | 109 | 5 | EA |
110 | 1110 | Miscellaneous | 110 | ||
111 | 1120 | Supply of flameproof cum weather proof to IP 65 or better SIL 2 smart pressure transmitter with in built display, SS manifold, isolation valve, canopy/sunshade, other erection material etc as per hook up drawing attached else where in tender complete as per specifications and Tender Document. (Transmitter will have IEC & ATEX certified minimum and any other certification as stated elese where in tender) | 111 | ||
112 | 1130 | TLF / TWD pump Suction end | 112 | 14 | EA |
113 | 1140 | TLF / TWD pumps Discharge end | 113 | 14 | EA |
114 | 1150 | Supply of flameproof cum weather proof to IP 65 or better SIL 2 Smart Differential pressure transmitter with in built display, SS 3 way manifold, canopy/sunshade, other erection material etc as per hook up drawing attached else where in tender complete as per specifications and Tender Document. (Transmitter will have IEC & ATEX certified minimumand any other certification as stated else where in tender) | 114 | ||
115 | 1160 | Across all TLF / TWD pump strainers | 115 | 14 | EA |
116 | 1170 | Supply of Wailing siren along with controller with a provision to operate locally as well as from control room, mounting accessories etc complete as per specification and tender document. | 116 | 1 | LS |
117 | 1180 | Supply of Ex-proof and weather proof Hooter cum Beacons along with accessories, mounting structure etc complete as per specification and tender document for audio visual alarm at field in case the MOVs installed at tank dyke drain and tank water draw off line is not fully closed. \nLocation : Near each tank dyke and to be installed outside dyke. | 117 | 3 | EA |
118 | 1190 | Supply of MCT block for entire Automation cable entry to Control Room, Admin Building, Invoice Room, Security Room, S&D, Driver's Rest Room with minimum 30% spare MCT blocks for furture cable entry alongwith frame and mounting accessories complete as per specification and tender document. | 118 | 2 | LS |
119 | 1200 | Cabling, JB, Earthing | 119 | ||
120 | 1210 | Supply of all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP and Non FLP Junction Boxes( Power, Signal and Control) along with accessories like certified double compression cable glands with PVC shrouds & plugs for excess entries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners etc , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned below but are required as per tender & BOQ requiremnt for complete Automation & integration with TAS complete as per specification and tender document: | 120 | ||
121 | 1220 | Complete TLF Automation System for integration of field equipments comprising of Mass Flow meters, Temperature Transmitter with RTD, Differential Pressure Transmitter across strainer, DCV, On-Off valve, Bottom Loading arm parking Position sensor, Rack Monitors, Earthing Relay/ Grounding Units, RIT, Driver's Ack PBS, Batch Controller, pump demand & ESD control cables from respective BCU to PLC, Proximity card readers, Layer 2 switches, Pump demand signals, FLP Sockets at alternate bays, Header line instruments (Pressure transmitter, ESD PBS (Local & Plant ESD at gantry and other places as specified in the tender), Power ESD to PMCC & TAS PDB, Ethanol blending system, Additive dosing system, Barrier gates along with accessories & PCR, Proximity card readers & single line LED display for TT registration, Bay Queue display board along with accessories, LED display screen at lock shed & Driver’s rest room, LED display board at license area Entry barrier Gate for displaying allocated bay to TT, status of activation of FLP push button station installed to manually stop respective product pumps, any other equipments supplied and installed for complete Tank Truck Automation System. | 121 | 1 | LS |
122 | 1230 | Complete Automation and integration of Tank Farm Management System for A/G product & Ethanol tanks, U/G product & Ethanol tanks, Fire Water Tanks, U/G static water sump tank, U/G service water sump tanks, Day tanks for Fire Engines & DG sets, Day tank & Mother tanks of Foam System, Sludge tanks, Additive & Blue dye tanks etc comprising of Primary Radar Gauges, Secondary Radar gauges, MSTW, PT for density measurement, Tank side indicators, AOPS, density probes, level switches (Hi & Lo), Level transmitter, any other equipments supplied and installed for complete Tank farm Management System | 122 | 1 | LS |
123 | 1240 | Complete Automation and integration of Fire detection and alarm System, Wailing Siren including integration of PA paging system with TAS | 123 | 1 | LS |
124 | 1250 | Complete Automation and integration of all the product loading & unloading pumps (TLF, TW, TLD), Ethanol pumps, additive pumps, blue dye pumps, agitators, submersible pumps for U/G product tanks, static water & service water sump tanks, sludge pumps, VFD for TLF loading pumps, TT calibration pumps and any other pumps mentioned in BOQ and tender requirement | 124 | 1 | LS |
125 | 1260 | Complete Automation and Integration of PT installed at TLF product pump suction & Discharge end; DPT installed across TLF pump strainer; level switch installed at static water sump, underground static water sump and TT calibration sump. | 125 | 1 | LS |
126 | 1270 | Complete Automation and Integration of hooter cum beacons installed outside dyke for dyke drain valve & water draw off line. | 126 | 1 | LS |
127 | 1280 | Complete integration and control of ROSOVs, DBBVs, MOVs, SOVs, Master Control Station for MOVs & DBBVs along with Local Push button station for local operation of the valves from outside dyke wall. | 127 | 1 | LS |
128 | 1290 | Complete integration of TAS equipments installed at Control room, panel room (including UPS and Battery), S&D, Security Gate/Room, Lock room, TM room, Driver rest room along with inter building redundant LAN cabling over OFC from Control Room to respective buildings - S&D, Security room, Lock Room, Admin Building, Driver rest room, and any other places complete as per tender requirement | 128 | 1 | LS |
129 | 1300 | Complete LAN cabling for IOCL intranet network inside Admin Building, Control Room, S&D, Invoice room, Lab building along with LAN face plate. \nCabling to be done from all LAN face plate to respective LAN switches and from all LAN switches to main Layer 2 switches at S&D room.\nTotal nos. of LAN points to be provided shall be as follows: \nControl Room : 16 Nos. \nAdmin Building 36+16= 52 Nos.\nS&D : 9 nos.\nInvoice Room : 6 Nos. \nLab building : 5+5 = 10 Nos.\nInterbuilding connectivity between switches to be done over OFC cables and LAN cabling inside building shall be done using CAT 6 cables inside PVC conduits with proper support above false ceiling, below false flooring etc as per requirement. | 129 | ||
130 | 1310 | Supply of GI strip ( 50 X 6) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories etc for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, TLF gantry in two layers with isolators for TT earthing, connecting earthing bus bar, CCTV pole with Earthing grid/ Earthpit etc required for complete Terminal Automation System as per Standard Design Engineering, specification and tender document. | 130 | 1 | LS |
131 | 1320 | Earth Pit | 131 | ||
132 | 1330 | Supply of Maintenance Free CPRI approved Earth pit ( Ashlok /Equivalent make ) as per IS : 3043 with 100 mm dia of minimum 3mtr length T45 model/equivalent safe earthing electrode with Pipe-in-pipe technology consisting of two mild steel pipes one inside the other, hot dip galvanized (80-100 microns), filled with high conductive & corrosion resistance crystalline mixture and backfilling compound around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Procedure recommended by chemical earth supplier and IS code to be finally adopted. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation \nAll Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification) | 132 | ||
133 | 1340 | TLF gantry | 133 | 2 | EA |
134 | 1350 | TT earthing | 134 | 2 | EA |
135 | 1360 | Control room | 135 | 4 | EA |
136 | 1370 | Pump house | 136 | 2 | EA |
137 | 1380 | Items mentioned below under this heading shall be Applicable only when there is deviation in quantity due to variation in given facilities/equipments) | 137 | ||
138 | 1390 | Cables Applicable only when there is deviation in quantity due to variation in given facilities/equipments) | 138 | ||
139 | 1400 | Supply of FRLS Armoured Copper Power cable as per tender specifications. | 139 | ||
140 | 1410 | 3C x 2.5 sqmm | 140 | 1 | RM |
141 | 1420 | 3C x 4 sqmm | 141 | 1 | RM |
142 | 1430 | 3C x 6 sqmm | 142 | 1 | RM |
143 | 1440 | 4C x 2.5 sqmm | 143 | 1 | RM |
144 | 1450 | 4C x 4 sqmm | 144 | 1 | RM |
145 | 1460 | 4C x 6 sqmm | 145 | 1 | RM |
146 | 1470 | 4C x 10 sqmm | 146 | 1 | RM |
147 | 1480 | Supply of FRLS Armoured Copper Control cable as per tender specifications. | 147 | ||
148 | 1490 | 2C x 1.5 sqmm | 148 | 1 | RM |
149 | 1500 | 3C x 1.5 sqmm | 149 | 1 | RM |
150 | 1510 | 4C x 1.5 sqmm | 150 | 1 | RM |
151 | 1520 | 6C x 1.5 sqmm | 151 | 1 | RM |
152 | 1530 | 8C x 1.5 sqmm | 152 | 1 | RM |
153 | 1540 | 10C x 1.5 sqmm | 153 | 1 | RM |
154 | 1550 | 12C x 1.5 sqmm | 154 | 1 | RM |
155 | 1560 | 16C x 1.5 sqmm | 155 | 1 | RM |
156 | 1570 | 24C x 1.5 sqmm | 156 | 1 | RM |
157 | 1580 | 32C x 1.5 sqmm | 157 | 1 | RM |
158 | 1590 | 48C x 1.5 sqmm | 158 | 1 | RM |
159 | 1600 | 60C x 1.5 sqmm | 159 | 1 | RM |
160 | 1610 | Supply of FRLS Armoured Copper Signal cable as per tender specifications. | 160 | ||
161 | 1620 | 1P x 1.5 sqmm | 161 | 1 | RM |
162 | 1630 | 2P x 1.5 sqmm | 162 | 1 | RM |
163 | 1640 | 6P x 1.5 sqmm | 163 | 1 | RM |
164 | 1650 | 8P x 1.5 sqmm | 164 | 1 | RM |
165 | 1660 | 12P x 1.5 sqmm | 165 | 1 | RM |
166 | 1670 | 1T x 1.5 sqmm | 166 | 1 | RM |
167 | 1680 | 8T x 1.5 sqmm | 167 | 1 | RM |
168 | 1690 | Supply of FS Armoured Copper Power cable as per tender specifications. | 168 | ||
169 | 1700 | 3C x 2.5 sqmm | 169 | 1 | RM |
170 | 1710 | 3C x 4 sqmm | 170 | 1 | RM |
171 | 1720 | 3C x 6 sqmm | 171 | 1 | RM |
172 | 1730 | 4C x 2.5 sqmm | 172 | 1 | RM |
173 | 1740 | 4C x 4 sqmm | 173 | 1 | RM |
174 | 1750 | Supply of FS Armoured Copper Control cable as per tender specifications. | 174 | ||
175 | 1760 | 2C x 1.5 sqmm | 175 | 1 | RM |
176 | 1770 | 3C x 1.5 sqmm | 176 | 1 | RM |
177 | 1780 | 4C x 1.5 sqmm | 177 | 1 | RM |
178 | 1790 | 12C x 1.5 sqmm | 178 | 1 | RM |
179 | 1800 | 16C x 1.5 sqmm | 179 | 1 | RM |
180 | 1810 | 24C x 1.5 sqmm | 180 | 1 | RM |
181 | 1820 | 32C x 1.5 sqmm | 181 | 1 | RM |
182 | 1830 | Supply of FS Armoured Copper Signal cable as per tender specifications. | 182 | ||
183 | 1840 | 1P x 1.5 sqmm | 183 | 10 | RM |
184 | 1850 | 2P x 1.5 sqmm | 184 | 10 | RM |
185 | 1860 | 6P x 1.5 sqmm | 185 | 10 | RM |
186 | 1870 | 8P x 1.5 sqmm | 186 | 10 | RM |
187 | 1880 | 12P x 1.5 sqmm | 187 | 10 | RM |
188 | 1890 | 1T x 1.5 sqmm | 188 | 10 | RM |
189 | 1900 | 8T x 1.5 sqmm | 189 | 10 | RM |
190 | 1910 | Supply of 6 core single mode armored optical fibre cable as per tender specifications and instructions of Engineer in charge. | 190 | 10 | RM |
191 | 1920 | Supply of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge. | 191 | 10 | RM |
192 | 1930 | Supply of 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes etc complete as per specification and tender document | 192 | 10 | RM |
193 | 1940 | Cable Trays (Applicable only when there is deviation in quantity due to variation in given facilities/equipments) | 193 | ||
194 | 1950 | Supply of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) alongwith with structural steel for mounting of the cable tray. Complete as per specifications / tender documents. | 194 | ||
195 | 1960 | 50mm | 195 | 10 | RM |
196 | 1970 | 100 mm | 196 | 10 | RM |
197 | 1980 | 150 mm | 197 | 10 | RM |
198 | 1990 | 300 mm | 198 | 10 | RM |
199 | 2000 | Junction Boxes (Applicable only when there is deviation in quantity due to variation in given facilities/equipments) | 199 | ||
200 | 2010 | Supply of Exd/FLP Junction Box (Power/Control/Signal JB) with IP 65 as per specification suitable for hazardous area of zone 1, group IIA/IIB, T3 or better having CCOE/CMRI approval. It shall be complete in all respect. Accessories like certified double compression cable glands with PVC shrouds & plugs for excess entries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners. Complete as per specification / tender documents. | 200 | ||
201 | 2020 | 24 way control JB | 201 | 5 | EA |
202 | 2030 | 18 way control JB | 202 | 5 | EA |
203 | 2040 | 12 way control JB | 203 | 5 | EA |
204 | 2050 | 8 way control JB | 204 | 5 | EA |
205 | 2060 | 6 way control JB | 205 | 5 | EA |
206 | 2070 | 4 way control JB | 206 | 5 | EA |
207 | 2080 | Supply of hot dip GI earth strip ( 50 X 6) within earth station. Hot dip galvanizing (800 gm/m2 as per IS 4759) shall be done after all fabrication. (Applicable only when there is deviation in quantity due to variation in given facilities/equipments) | 207 | 10 | RM |
208 | 2090 | Supply of 50 mm HDPE pipe of minimum 2.5 mm thick along with accessories as per tender specifications and instructions of Engineer in charge. (Applicable only when there is deviation in quantity due to variation in given facilities/equipments) | 208 | 10 | RM |
209 | 2100 | Supply of Redundant Master Control Station (min 120 channels) in cabinet for Motor Operated Control Valves & Actuators for interfacing with MOVs, MOVDBBs & TAS PLC on redundant communication Link. Each daisy chain loop for MOVs in MCS shall not be loaded more than 60% of the loop capacity. | 209 | 1 | EA |
210 | 2110 | SERVICE COMPONENTS | 210 | ||
211 | 2120 | TANK LORRY FILLING | 211 | ||
212 | 2130 | Installation, testing and commissioning of double Case Positive Displacement Meter of size 80 mm with Pulse Transmitter in Flameproof and Weather Proof (IP 65) enclosure complete as per specifications for MS/HSD/SKO/ATF use | 212 | 14 | EA |
213 | 2140 | Installation, Integration, Testing and Commissioning of Strainer cum Air eliminator alongwith differential pressure transmitter across the Strainer Cum Air Eliminator along with accessories, SS tubing, needle valves etc complete as per specifications and tender document. For product line size 80 mm - TLF\n | 213 | 14 | EA |
214 | 2150 | Installation, Integration, Testing and Commissioning of Multistage Piston type Digital Control Valve (DCV) alongwith accessories, secure locking of the needle valves to avoid manual throttling of the needle valves after final tuning of the DCV has been done, secure key etc along with accessories complete as per specifications and tender document. For product line size 80 mm - TLF | 214 | 14 | EA |
215 | 2160 | Installation, Integration, Testing and Commissioning of Diaphragm type, hydraulically operated, electrically actuated, solenoid operated ON-OFF Valve alongwith accessories etc for line size 80 mm complete as per specifications and tender document. | 215 | 14 | EA |
216 | 2170 | Installation, Testing and Commissioning of 1no. manual operated DBBV and 2 nos. of 80 NB, full bore, zero leakage, fire safe ball valves alongwith associated piping, Tee connection, gaskets, copper jumpers, fasteners, blind flanges at one end of each ball valves, pipe fittings, SOR flanges etc for each loading point assembly for making arrangement to connect Mobile master meter for proving of TLF PD meter complete as per specifications and tender documents. | 216 | 14 | SET |
217 | 2180 | Installation, Testing and Commissioning of top loading arm of size 80 mm NB along with 1 no. full bore isolation ball valve (80 mm), TRV with two nos. isolation valves at inlet and outlet of TRV, associated piping for connecting loading arm with the metering skid & TRV to outlet to nozzle before DCV, mounting structure etc complete as per specifications and tender document. Application: MS/HSD/SKO/ATF | 217 | 14 | EA |
218 | 2190 | Integration,Testing and Commissioning of Tank Truck grounding unit (Earthing Relay/Device ) - resistive-capacitive type alongwith accessories like two nos. of flexible coiled cable of minimum 16 (Sixteen) feet with high quality rugged, heavy duty SS/ brass grounding bolt/stud/socket/plug, FLP double compression glands, Ex-Plug, mounting structure etc, complete as per specification and tender documents.\nOr \nInstallation, Integration,Testing and Commissioning of Tank Truck grounding unit (Earthing Relay/Device ) - resistive type alongwith accessories like Heavy Duty flexible cable with plug with SS contacts connected to the grounding unit. Each TT for loading shall be provided with compatible SS BALL with integral diode, SS nut and lock washer for connecting the plug to the SS ball for grounding of the TT, FLP double compression glands, Ex-Plug, mounting structure etc, complete as per specification and tender documents. | 218 | 8 | EA |
219 | 2200 | Installation, Integration, Testing and Commissioning of Ex-proof field mounted Remote Interaction Terminal (RIT) alongwith FLP double compression glands and ExProof-plugs, structural supports etc complete as per specifications and tender documents. | 219 | 14 | EA |
220 | 2210 | Installation, Integration, Testing and Commissioning of Ex-proof field mounted Driver Ack Push Button station alongwith FLP double compression glands and ExProof-plug, structual suppots etc complete as per specifications and tender documents. | 220 | 8 | EA |
221 | 2220 | Installation, Integration, Configuration, Testing and Commissioning of Microprocessor based Field mounted dual arm Batch Controller with interface to minimim 2 nos.of main product + 2 nos. of blend product + 2 nos. of additive product in Flameproof and weather proof enclosure alongwith accessories like double compression glands, Exd Plugs, hoods, structural supports etc complete as per specification and tender document.\nor\nInstallation, Integration, Configuration, Testing and Commissioning of 2 nos. of Microprocessor based Field mounted single arm Batch Controller with interface to minimim 1 no. of main product + 1 no. of blend product + 1 no. of additive product in Flameproof and weather proof enclosure alongwith accessories like double compression glands, Exd Plugs, hoods, structural supports etc complete as per specification and tender document.\n\n | 221 | ||
222 | 2230 | For TLF product loading | 222 | 8 | EA |
223 | 2240 | Installation, Integration, Testing and Commissioning of intrinsically safe / flameproof type proximity card reader alongwith mounting accessories etc complete as per specifications for mounting at | 223 | ||
224 | 2250 | TLF bays | 224 | 8 | EA |
225 | 2260 | License area Entry barrier gates ( 1 nos. Per Entry barrier Gate) | 225 | 1 | EA |
226 | 2270 | License area Exit barrier gates ( 1 no. Per Exit barrier Gate) | 226 | 1 | EA |
227 | 2280 | Security Entry & Exit barrier gates ( 1 no. Per barrier Gate) | 227 | 4 | EA |
228 | 2290 | Near Security Gate ( for TT registration ) | 228 | 2 | EA |
229 | 2300 | Installation of supplied Metering Skid (MS structure) for mounting of complete metering equipments as per BOQ and schematic drawing for one main product, one blend product and one additive dosing system. The metering assembly comprises of : \nMain product line: Strainer cum air eliminator, ON-Off valve, Spool piece with tapping for additive dosing and TT installation, Online Master Meter proving manifold, PD meter, spool piece with tapping for connecting outler of TRV, DCV, Spool Piece with tapping for Ethanol blending & TRV installation. \n\nBlend Product line: Strainer cum air eliminator, ON-Off valve, Spool piece with tapping for TT installation, Online Master Meter proving manifold, PD meter, DCV, NRV, isolation vale and finally connected to Main stream line tap off point after DCV. \nAdditive Dosing System comprises of isolation valve, Additive injection panel/ block, connecting piping, NRV, isolation valve and finally connecting to Main stream tap off point before PD meter. \n\nProvision to be made in the skid for mounting of Batch Controller, Rack Monitor, Grounding unit, RIT, Driver's Ack Push button stations, card reader, FLP junctions boxes (power, Signal and Control), FLP power isolator switch, interconnecting cables from respective equipment to JBs, cable trays with covers, glands, support, MS structure, nuts bolts, gaskets, Tees, bends, elbows, flanges, nozzles, plugs, isolators, any other equipment if required as per design Engineering etc complete as per specification and tender document. | 229 | 14 | MT |
230 | 2310 | Installation, Integration, Testing and Commissioning of 3M barrier gates along with accessories, controllers etc complete as per specification and tender document for installation at following location. | 230 | ||
231 | 2320 | TLF gantry entry gates | 231 | 1 | SET |
232 | 2330 | TLF gantry exit gate | 232 | 1 | SET |
233 | 2340 | Security Entry/Exit gates | 233 | 2 | SET |
234 | 2350 | Installation, Integration, Testing and Commissioning of barrier gate traffic lamps (Red, Amber & Greeen LED Cluster type) along with Standpost of suitable height, foundation, mounting structure accessories etc complete as per specification and tender document | 234 | 4 | SET |
235 | 2360 | DISPLAY BOARDS | 235 | ||
236 | 2370 | Installation, integration, testing and commissioning of weather proof LED bay queuing display board (Minimmum 15 lines x 100 mm Character height x 25 characters per line) for outdoor application at TT parking area or any other designated place as per site engineer along with accessories like public address system, speakers, amplifer, mike, structral steel for mounting of the same, canopy/sunshade etc complete as per specifications and tender document. | 236 | 1 | EA |
237 | 2380 | Installation, integration, testing and commissioning of LED monitor of minimum 42" along with required hardware and software for interfacing with TAS, lockable enclosure (wall mounted/ ceiling mounted) for mounting the monitor alongwith accessories for repeat display of main Bay Queue Display board at Driver's restroom or any other designated place as per site engineer complete in all respect as per tender requirement. Kindly note, no additional payment shall be made for any additional hardware/ software/ cable etc required for integration of the monitor with TAS. | 237 | 1 | EA |
238 | 2390 | Installation, integration, testing and commissioning of weather proof Single line LED display board (Minimmum 1 line x 25 mm Character height x 11 characters per line) for outdoor application near Security Gate/ TT parking Area along with mounting accessories, canopy/ sunshade etc complete as per specifications and tender document for displaying the TT Registration no. bilingual (English + local language) of reported TT whose proximity card has been shown on the PCR adjacent to the display board for TT reporting. | 238 | 2 | EA |
239 | 2400 | Installation, integration, testing and commissioning of weather proof Single line coloured LED display board with scroll and flash effects (Minimmum 1 line x 50 mm Character height x 10 characters per line) for outdoor application near license area Entry barrier Gate along with mounting structure, canopy/ sunshade, accessories etc complete as per specifications and tender document for displaying the bay no. (Bilingual) etc of the authorised TT reported at license area Entry Gate as per FDR.\n(2 nos. per License Area Entry Barrier Gate) | 239 | 2 | EA |
240 | 2410 | Installation, Powering, Testing and Commissioning of single phase FLP socket with cover at alternate bay alongwith mounting accessories for powering master meter skid complete as per specifications / tender documents.. Power to be drawn from MCC room. | 240 | 4 | EA |
241 | 2420 | Ethanol Dosing System | 241 | ||
242 | 2430 | Installation Testing and commissioning of double Case Positive Displacement Meter of size 50 mm for ethanol | 242 | 2 | EA |
243 | 2440 | Installation, Integration, Testing and Commissioning of Strainer cum Air eliminator for line size 50 mm alongwith differential pressure transmitter across the Strainer Cum Air Eliminator along with accessories, SS tubing, needle valves etc complete as per specifications and tender document. | 243 | 2 | EA |
244 | 2450 | Installation Testing and commissioning of multistage Diaphragm type Digital Control Valve of size 50 mm along with provision for locking arrangement for solenoid valves as per specification for ethanol | 244 | 2 | EA |
245 | 2460 | Installation, Integration, Testing and Commissioning of Diaphragm type, hydraulically operated, electrically actuated, solenoid operated ON-OFF Valve alongwith accessories etc for line size 50 mm complete as per specifications and tender document. | 245 | 6 | EA |
246 | 2470 | Installation, Testing and Commissioning of 1no. manual operated DBBV and 2 nos. of 50 NB, full bore, zero leakage, fire safe ball valves alongwith associated piping, Tee connection, gaskets, copper jumpers, fasteners, blind flanges at one end of each ball valves, pipe fittings, SOR flanges etc for each loading point assembly for making arrangement to connect Mobile master meter for proving of TLF PD meter complete as per specifications and tender documents. | 246 | 6 | SET |
247 | 2480 | Additive dosing System | 247 | ||
248 | 2490 | Installation, Integration, Testing and Commissioning additive injection block alongwith accessories for XTRAPREMIUM and XTRAMILE complete as per specification and tender document.\nNote - All the materials within Additive injection panel shall be SS 316. | 248 | 2 | SET |
249 | 2500 | Installation, Fabrication, Welding, Flushing, Testing and Commissioning of A106 Gr B Schedule 80 pipe Dia 25 mm from additive dosing system integration & commissioning as per tender document | 249 | 200 | RM |
250 | 2510 | Installation, Fabrication, Welding, Flushing, Testing and Commissioning of A106 Gr B Schedule 80 pipe Dia 12 mm from additive dosing system integration & commissioning as per tender document | 250 | 200 | RM |
251 | 2520 | Installation, Testing and Commissioning of necessary hardware Like reducer, Elbows, equal Tee ,unequal tee, Flanges, Coupling, Ball Valve for Isolation, NRV etc as required for piping and commissioning of the system | 251 | 1 | LS |
252 | 2530 | Note: Additive tank skid along with piping upto TLF header line shall be supplied and installed by IOCL. Integration of additive pumps for remote operation, level measurement shall be in the successful bidder's scope. | 252 | ||
253 | 2540 | TLF Header line instruments | 253 | ||
254 | 2550 | Installation and commissioning of Densitometer on by-pass line of TLF header line with in built display. The work includes necessary cutting of pipeline after emptying of product pipeline, flushing and degassing etc and welding suitable bypass line and nozzle for fixing transmitter complete with accessories as per specifications. | 254 | 3 | SET |
255 | 2560 | Installation, Integration, Testing and Commissioning of flameproof cum weather proof, min SIL 2 smart pressure transmitter with display unit, SS manifold,1 no isolation ball valve, sunshade with mounting accessories etc on the TLF main header line complete as per specifications and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) (Range 0-15 kg/cm2) | 255 | 3 | EA |
256 | 2570 | Tank Farm Management System | 256 | ||
257 | 2580 | Installation, Integration, Testing and Commissioning of minimum SIL 2 certified Non - contact type Radar level gauges with instrument accuracy of +/- 1 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 257 | ||
258 | 2590 | For Cone Roof Vertical tanks (Primary and Secondary Radar Gauges - HSD-7x2, SKO-1x2) | 258 | 18 | EA |
259 | 2600 | For Internal Floating Roof Vertical tanks (Primary and Secondary Radar Gauges - MS-5x2) | 259 | 8 | EA |
260 | 2610 | For underground horizontal product tanks (Ethanol - 2 no. + 2 no. upcoming) | 260 | 2 | EA |
261 | 2620 | Installation, Integration, Testing and Commissioning of Radar level gauges with instrument accuracy of +/-3 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 261 | ||
262 | 2630 | For Water Tanks (3 nos.) | 262 | 3 | EA |
263 | 2640 | Installation, Integration, Testing and Commissioning of multi point temperature averaging sensor with integrated water interface probe (MSTW) along with mounting accessories etc complete as per specification and tender document. | 263 | ||
264 | 2650 | With minimum 8 elements temperature sensor (for above ground tanks - MS, HSD, SKO) | 264 | 13 | EA |
265 | 2660 | With minimum 2 elements temperature sensor (Ethanol - 2 no. + 2 no. upcoming) | 265 | 2 | EA |
266 | 2670 | Installation, Integration, Testing and Commissioning of Density probe along with accessories etc for density measurement of the product complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 266 | ||
267 | 2680 | For A/G Tanks - 3 elements | 267 | 13 | EA |
268 | 2690 | For U/G tanks - 1 element | 268 | 2 | EA |
269 | 2700 | Installation, Integration, Testing and Commissioning of Tank Side indicator along with mounting accesories etc for TFM system for displaying inventory data complete as per specification and tender document. (TSI will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) | 269 | ||
270 | 2710 | For Vertical Product tanks - (Primary & Secondary Radar Gauges) | 270 | 26 | EA |
271 | 2720 | For U/G Product tanks - Primary Radar Gauge | 271 | 2 | EA |
272 | 2730 | For Water Tanks (3 nos), Sludge tank(1 no.) | 272 | 3 | EA |
273 | 2740 | Installation, Integration, Testing and Commissioning of top mounted minimum SIL2 certified Overspill detector (vibrating fork type) of suitable probe length along with mounting accessories etc complete as per specification and tender document | 273 | ||
274 | 2750 | For Vertical Product tanks | 274 | 13 | EA |
275 | 2760 | For U/G Product tanks | 275 | 2 | EA |
276 | 2770 | Installation, Integration, Testing and Commissioning of parallel redundant Communication Interface Units (CIU) including all accessories etc for tank farm management system complete as per specification and tender document. | 276 | ||
277 | 2780 | For Primary Radar gauges, Radar Gauges installed in under ground tank, water tank & Sludge tank | 277 | 1 | SET |
278 | 2790 | For Secondary Radar Gauges | 278 | 1 | SET |
279 | 2800 | Installation, Integration, Configuration, Testing and Commissioning of 2 Nos. of TFMS Server (19" Rack mounting type ) along with 1 No. 19" rack mounted industrial monitor keyboard drawer, optical mouse, 4 port industrial grade KVM switch, Licensed OS (latest supported by TFMS software), Licenced Antivirus, Licenced latest MS Office professional, TFMS licensed software from Radar Gauge OEM etc complete as per specification and tender document. | 279 | 1 | LOT |
280 | 2810 | Installation, Integration, Configuration, Testing and Commissioning of TFMS Workstation with minimum 23" LED colour monitor, standard keyboard, mouse, Licensed OS(latest supported by TFMS software), Licenced Antivirus, Licenced latest MS Office proffestional, TFMS licensed client software from same Radar Gauge OEM etc complete as per specification and tender document. \n | 280 | ||
281 | 2820 | 19" Rack mounting type at Control Room | 281 | 1 | EA |
282 | 2830 | Tower type at TM's room | 282 | 1 | EA |
283 | 2840 | Push Buttons Outside Dyke Walls | 283 | ||
284 | 2850 | Installation, Integration, Testing and Commissioning of Exd/FLP Local Push button station cum indication lamp out side tank farm dyke wall for open and close of ROSOVs and DBBVs (tank's inlet, outlet and recirculation line) along with mounting structure, accessories etc complete as per specifications and tender document. | 284 | 52 | EA |
285 | 2860 | ESD PUSH BUTTON STATION | 285 | ||
286 | 2870 | Installation, Integration, Testing and Commissioning of Exd/FLP ESD push button stations, mushroom head type, with protection cover to avoid accidental activation alongwith mounting structure complete as per specification and tender document. | 286 | ||
287 | 2880 | Local ESD Push Button Station ( Each Battery of TLF - 1 nos.) | 287 | 1 | EA |
288 | 2890 | Plant ESD Push Button Station ( Each battery of TLF - 1 nos.) | 288 | 1 | EA |
289 | 2900 | Plant ESD Push Button Station ( At TLF and TWD pump house) | 289 | 2 | EA |
290 | 2910 | Installation, Integration, Testing and Commissioning of ESD push button stations (for indoor application), mushroom head type with protection cover to avoid accidental activation alongwith mounting structure complete as per specification and tender document. (control room - 1 no., security room - 1 no., TM's cabin - 1 no.) | 290 | 3 | EA |
291 | 2920 | Control Room equipments | 291 | ||
292 | 2930 | Design, Engineering, Setup, Configuration, Integration with TAS, Installation, Testing & Commissioning of Dual redundant (Parallel/ Hot Standby) Programmable Logic Controller (Process PLC) along with PLC Panels, Marshalling Panels, Biometric fingerprint cum contactless smart card reader with accessories, limit switches, Input Output modules, Power supply units, Relays with base, barriers, TBs, Dual Ethernet ports per processors, Serial Interface Modules, HMI console , wirings, glands, plugs, other modules/ hardwares required for interfacing all the required field and control room equipments including spare requirements, licenses, tags, GUI, licensed OPC compliant softwares etc complete as per specification and tender document. | 292 | 1 | LS |
293 | 2940 | Design, Engineering, Setup, Configuration, Integration with TAS, Installation, Testing, Commissioning of Triple / Quadruple Modular Redundant, SIL 3 TUV/ EXIDA certified Safety PLC along with PLC Panels, Marshalling Panels, Biometric fingerprint cum contactless smart card reader with accessories, limit switches, Dual redundant Input Output modules, Power supply units, Relays with base, barriers, TBs, Dual Ethernet ports per processor, Serial Interface Modules, HMI , wirings, glands, plugs, other modules/ hardwares required for interfacing all the required field and control room equipments including spare requirements, licenses, tags, GUI, licensed OPC compliant software etc complete as per specification and tender document. | 293 | 1 | LS |
294 | 2950 | Design, Engineering, Set-up, Installation, Configuration, testing & Commissioning of two nos. of Load Rack Computers (LRC Servers ) rack based along with High availability redunancy software & working on redundant (Primary and Secondary) hot standby mode , 19" rack mounted industrial monitor keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, SQL, oracle, RDBMS (license copy) etc complete as per specifications and Tender Document. \n OR\nDesign, Engineering, Set-up, Installation, Configuration testing & Commissioning of Load Rack Computer (LRC Server - Dual Mode Redundant Grade with built in redundancy) Rack mounted alongwith 9" rack mounted industrial monitor keyboard drawer, optical mouse and combo 4 port KVM switch, OS, Antivirus, SQL, oracle, RDBMS (license copy) etc complete as per specifications and Tender Document. \n\nLRC system solution shall have either of the above mentioned configuration meeting the complete specification and tender requirements. \n\nIn addition, the LRC system shall be configured to have Zero Downtime to repair, Full data redundancy shall be provided using proven technology , it shall also provide port level redundancy.The system solution shall be capable of self fault detection and isolation, all necessary hardware/software configuration etc to achieve the same shall be included.\n\n\n\n | 294 | 1 | LOT |
295 | 2960 | Installation of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, terminal blocks and wiring etc complete as per specification and tender document for mounting of below mentioned equipments | 295 | ||
296 | 2970 | For mounting of LRC Server along with associated rack mounted monitors, rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking & OFC components, terminal server, Ethernet switch, GSM modems MCBs etc as per specification and tender document | 296 | 1 | LS |
297 | 2980 | For mounting of TFMS Server along with associated rack mounted monitors, rack mounted keyboard, mouse, 4 port industrial grade KVM switches, power adapters, networking & OFC components, CIUs MCBs etc as per specification and tender document | 297 | 1 | LS |
298 | 2990 | For mounting of Rack mounted Master Control Stations (4 sets of redundant MCS) for MOVs & DBBVs along with power adaptors, MCBs, required accessories etc as per specification and tender document | 298 | 1 | LS |
299 | 3000 | Design, Installation, Configuration, Testing & Commissioning of Complete Terminal Automation Software for LRCS and Operator work Stations with dongle/key, licenses, media, documentation, including equipment fault detection module / software etc complete as per specifications and tender documents. Vendor to provide the complete software to meet the Terminal Automation System as per tender scope of work and requirements.\n\nTAS software shall be interfaced with following but not limited to major sub-systems / equipments anlongwith GUI development for monitoring, logging, reporting and Controls-Interlocks etc as per specification and tender document.\n\n | 299 | 1 | LS |
300 | 3010 | \n- Safety PLC, Process PLC\n- TLF Automation System ( BCU, PD meter, Barrier Gates, Bay Queue Display, TT registration and entry System, Bay allocation Display, Invoice generated display, Additive Dosing system, Ethanol blending System, rack monitors etc)\n- Valve Automation System (ROSOVs, MOVs, DBBV, MCS Interface, SOVs, etc)\n- Tank Farm Management System ( Primary & Secondary Radar Gauging, AOPS, PTs, DPT, LS, Density probes, MSTW, CIU etc)\n- Pipeline/ Refinery PLC Interface, OMC PLC interface\n- MCC, Pump, Borewell, DG Sets, Air compressors, UPS interface, VFDs\n- PAGA Interface \n- HC Detection System Interface\n- FAS Interface, Fire Fighting System, HVLR, Fire Alarm System Interface, Fire Engines, DG Set, Jockey pumps, Foam pumps etc\n- VRU Package Units\n-Effluent treatment plant\n- CCTV systems\n- Access Control System\n- SKO Blue Dye Dosing System\n- SAP-TAS, SAP-TFMS, TT planning interface ((TT Loading, WB , Tanker/ Ship/ Barge in-line with protocol & sub systems covered in the work)\n- ESD System, Emergency panel, Power ESD, Local ESD\n- Power distribution boards, UPS, OIC, EWS, TTES, etc\n- Any other Third Party Interface/ devices as per scope of the work order etc | 300 | ||
301 | 3020 | Installation, Configuration, Integration, Testing and Commissioning of Operator Interface Console Computer (OIC) minimum 23" color LED monitor, standard keyboard, mouse, client software, SCADA, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. | 301 | ||
302 | 3030 | 19" Rack mounted type in Control Room ( 2 OICs, 1 for alarm Display, 1 for fire fighting System) | 302 | 4 | EA |
303 | 3040 | Tower mounted type in TM's Cabin and Invoice Room ( 1 no OIC in TM cabin, 1 no. OIC In Invoice room) | 303 | 2 | Ea |
304 | 3050 | Installation, Integration, Testing and Commissioning of Engineering Workstation (EWS) with minimum 23" colour LED monitor, standard keyboard, mouse, client software, SCADA,OS, Antivirus, MS office professional etc. complete as per specifications and tender document. (Locations: 1 no. in CR for both Process and Safety PLC) - Rack Mounted type | 304 | 1 | EA |
305 | 3060 | Installation, Integration, Testing and Commissioning of Tank Truck Entry System (TTES) Workstation with minimum 23" colour LED monitor, standard keyboard, mouse, TTES software, SCADA, OS, Antivirus etc. complete as per specifications and tender document. (Locations: 2 nos. in S&D + 1 no. in Control room) | 305 | ||
306 | 3070 | 19" Rack mounted type in Control Room | 306 | 1 | EA |
307 | 3080 | Tower mounted type in S&D | 307 | 2 | EA |
308 | 3090 | Installation, Integration, Configuration, Testing and Commissioning of Terminal servers (rack mounted) alongwith accessories and inbuilt/externally mounted lightening and Surge Protection Device Type (1+2) connected to serial port for interfacing field units such as PD meters, card readers, Bay Queue display units (Indoor & outdoor), Single line Display unit for TT reporting and Bay allocation, UPS, DG sets any other third party interface etc with LRCS/TAS complete as per specification and tender document.\nNote: Terminal Server to be configured in Dual Redundant mode. | 308 | ||
309 | 3100 | 32 ports at Control Room | 309 | 2 | EA |
310 | 3110 | 16 ports at S&D | 310 | 2 | EA |
311 | 3120 | Installation, Integration, Configuration, Testing and Commissioning of 24 ports Layer 3 Industrial Grade Managed Ethernet Switches - (rack mounted) (10/100/1000 MBPS) along with SFP, copper, fiber modules, accessories for connecting LRCS, process PLC, safety PLC, BCUs, CCTV, ACS, OIC, TFMS, TTES, printers, IOCL LAN (SAP) and other TAS equipment as per system architecture and design requirement complete as per specification and tender document.\nNote:\n1. The switches are to be configured in Dual Redundant mode.\n2. OFC ports to be provided for connecting interbuilding LANs, BCUs and any other equipment which are to be connected to above switch and the communication is through OFC cable. | 311 | 2 | EA |
312 | 3130 | Installation, Integration, Configuration, Testing and Commissioning of minimum 10 ports ( 8 nos. copper ports and 2 nos optical ports) Layer 2 Industrial grade Managed Ethernet Switches (rack mounted) along with accessories for connecting BCU with TAS, equipments installed in S&D room, Lock room, Security room, Terminal Manager room and other TAS equipments as per system architecture and design requirement complete as per specification and tender document. \n\nNote: \n1. Ethernet switches for BCU communication shall have suitable mounting arrangement to mount inside FLP JBs. \n2. The switches are to be configured in Dual Redundant mode.\n3. In case BCU has only one Ethernet port, then for redundant communication vendor has to provided additional Industrial Grade Terminal Server / Gateway for Serial to Ethernet conversion at field and connect the same to the redundant Ethernet switch at no additional cost to IOCL. | 312 | ||
313 | 3140 | For BCU integration at TLF & TT Calibration shed (copper ports of 10/100 MBPS) | 313 | 8 | EA |
314 | 3150 | At Lock Shed (copper ports of 10/100/1000 MBPS) | 314 | 1 | EA |
315 | 3160 | At Admin Building (TM cabin) (copper ports of 10/100/1000 MBPS) | 315 | 1 | EA |
316 | 3170 | At S&D Room (copper ports of 10/100/1000 MBPS) | 316 | 1 | EA |
317 | 3180 | At Security Room (copper ports of 10/100/1000 MBPS) | 317 | 1 | EA |
318 | 3190 | Installation, Integration, Configuration, Testing and Commissioning of Layer 2 Managed Ethernet Switches (rack mounted) along with SFP, copper, fiber modules, accessories, etc for IOCL LAN network complete as per specification and tender document. | 318 | ||
319 | 3200 | 24 ports ( 8 optical & 16 Copper ports) - at S&D Building | 319 | 1 | Ea |
320 | 3210 | 24 ports ( 2 optical & 22 Copper ports) - at Admin Building | 320 | 1 | Ea |
321 | 3220 | 24 ports ( 2 optical & 22 Copper ports) - at Control Room | 321 | 1 | Ea |
322 | 3230 | 8 ports ( 2 optical & 6 Copper ports) - at Invoice Room | 322 | 1 | Ea |
323 | 3240 | 16 ports ( 2 optical & 14Copper ports) - at QC Lab | 323 | 1 | Ea |
324 | 3250 | Installation of Wall mounted Network Rack-minimum 10U 19" Rack for mounting of Terminal Server/Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at Security Room, TM room, Invoice Room, S&D for TAS equipments | 324 | 2 | EA |
325 | 3260 | Installation of 19" Network Rack of suitable sizes for mounting of Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at S&D, Admin building, Control Room, Invoice room & S&D of IOCL LAN network. | 325 | 1 | LS |
326 | 3270 | Installation, Integration, Configuration, Testing and Commissioning of Monochrome Laser Printer along with accessories for TAS and TFMS report printing in control room (2 nos.), 2 nos at security room & 1 no. at Invoice room for FAN printing complete as per specifications and tender document. | 326 | 2 | EA |
327 | 3280 | Installation, Integration, Configuration, Testing and Commissioning of heavy duty high speed line network printer (min. 500 LPM) along with print server , Printer Stand (open pedestal type) and accessories for invoice printing in lock shed room, complete as per specifications and tender document. \nNote: Incase Network printer is not available, suitable converter/ print server to be provided for putting the printer on network.\n | 327 | 2 | EA |
328 | 3290 | Installation, Integration, Testing and Commissioning of parallel redundant UPS of minimum capacity of 20 KVA or as per load calculation (whichever is higher) for entire TAS equipments and third party devices integrated with TAS and powered through TAS UPS with 30% spare capacity for future load connection. The scope also includes supply of battery bank (2x50% for ½ hour back up time for each UPS at rated load- Semi Maintenance free Ni-Cd batteries) along with stand, supports for mounting of the UPS and batteries etc complete as per specification and tender document. | 328 | 1 | Set |
329 | 3300 | Installation, Testing and Commissioning of UPS Power Distribution Panel for powering Process PLC Panel, Safety PLC panel, LRCS, OIC & EWS stations, TFMS System, TTES, printers, Bay Instruments , other control room equipments, Tank Farm Instruments , CCTV system , Fire Detection System, Access control system, Bay Queue Display boards, other display boards, ROSOV, header line instruments and any other TAS equipments where UPS power are required for smooth un-interrupted operation as per OEMs recommendation. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation etc to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring voltmeter, ammeter etc & as per specifications and tender document\nNote: Minimum 20% spare power points to be made available for future use. | 329 | 1 | LS |
330 | 3310 | Installation of Open desk operator consoles, chairs, printer tables etc complete as per specification and tender document. | 330 | ||
331 | 3320 | Open desk operator consoles for mounting of 2 nos of 19" Rack mounted CPU, 2 nos of key boards, 2 nos of mouse, two nos of monitor in two tiers , etc complete as per specification and tender document.\n\n(For mounting of 2 nos. OICs, 1 no. Alarm Display OIC, 1 no. Fire fighting OIC, 1 no. TTES, 1 TFMS workstation, 1 no. CCTV client, 1 no. Acess control Server, 1 no. EWS) | 331 | 4 | EA |
332 | 3330 | Chairs (Godrej PCH 5002T or equivalent) | 332 | 4 | EA |
333 | 3340 | Standard Printer Tables of Godrej or equivalent make (2 nos. in control room, 2 nos. at security gate, 1 no. in security room for visitor management) | 333 | 5 | EA |
334 | 3350 | Standard Computer Table of Godrej or equivalent make for installation of OIC, TFMS client PC and CCTV client PC in TM room (3nos.), CCTV client PC, ACS server in security room (2nos.), TTES in S&D room (2nos.) and OIC in lock shed room (1 no.) | 334 | 2 | EA |
335 | 3360 | Installation, Integration, Configuration, Testing and Commissioning of Redundant GSM modem (Industrial grade, IP based) along with accessories for auto SMS as per specification and tender document. | 335 | 1 | LS |
336 | 3370 | Installation, Integration, Configuration, Testing and Commissioning of minimum 40" HD LED monitor along with 1 no. of hooter, mounting accessories, cables etc for critical alarms display and annuciation (1no.) and Fire fighting system display (1 no.) complete as per specifications and tender document. | 336 | 2 | EA |
337 | 3380 | Hydrocarbon Detection system | 337 | ||
338 | 3390 | integration, Calibration, Testing, and Commissioning Flameproof cum weather proof (IP 66 or better) min SIL 2 certified Hydrocarbon gas detectors along with calibration kit, accessories and structural supports etc.\n | 338 | ||
339 | 3400 | Point type Infrared detector (Indicative location: Each tank dyke sump pit inside dyke wall - 13 nos, Near ROSOVs of MS & Ethanol tanks- 15 nos, Pump house drain pit- 1 nos, Vapour recovery system drain pit - 1 no.) | 339 | 7 | EA |
340 | 3410 | Open path type Infrared detector (0-40m) along with alignment telescope, configuration kit, IR blocking film etc (Tentative location: MS Dyke covering ROSOVs - 6 nos, Producty pump house - 2 nos, Product PH manifold - 2 nos.)\n | 340 | 7 | EA |
341 | 3420 | Instalation, integration, testing and commissioning of weather proof and Explosion proof Hooter cum beasons/ flash light along with accessories and structual supports as per specification. ( 1 no. near each tank Dyke- 4 nos., Near ump House- 1no. , Near Vapour recovery system-1no.) | 341 | 5 | EA |
342 | 3430 | Automatic Fire Detection and Alarm System | 342 | ||
343 | 3440 | Installation, configuration, testing, integration and Commissioning of microprocessor based automatic Fire Alarm Panel along with required Software, and hardwares like Control module, monitor module, fault isolation module ( in built/ External), Mimic panel, mounting structure support etc complete as per standard design engineering, specification and tender document. \n\nFire Detection System shall be interfaced with TAS for GUI & Alarm, event monitoring, recording & printing as mentioned in tender document.\nScope also includes the Demonstration of System to Safety, Operations & Engineering team from user and OISD & Statutory audit & periodic testing. | 343 | 2 | EA |
344 | 3450 | Installation, configuration, testing, integration and Commissioning of Repeater Panel along with software, hardware, mimic panel, mounting accessories etc required as per standard design Engineer, specifications and tender document complete in all respect. \n(Tentative location : Security Gate - 1 no., Fire Pump House - 1 no.) | 344 | 2 | EA |
345 | 3460 | Installation, Integration, Testing and Commissioning of addressable type detectors along with accessories, fault isolation module (Inbuilt/ External), structural supports etc required as per standard design engineering, specification and tender document complete in all respect. | 345 | ||
346 | 3470 | Combination/Multisensor Detector | 346 | 15 | EA |
347 | 3480 | Installation, Integration, Testing and Commissioning of Manual Call Point along with accessories, fault isolation module (Inbuilt/ External) and structural supports etc required as per standard design engineering, specification and tender document complete in all respect. | 347 | ||
348 | 3490 | Ex-proof and weather proof MCP | 348 | 8 | EA |
349 | 3500 | Weather proof MCP | 349 | 3 | EA |
350 | 3510 | Installation, Integration, Testing and Commissioning of Hooter along with accessories, fault isolation module (inbuilt/ External), structural supports etc required as per standard design engineering, specification and tender document complete in all respect. | 350 | ||
351 | 3520 | Weather proof Hooter | 351 | 5 | EA |
352 | 3530 | Installation, Integration, Testing and Commissioning of Response Indicator along with accessories, mounting structure etc required as per standard design engineering, specification and tender document complete in all respect.\nThe same to be connected with individual detector installed at places where they are not easily visible e.g. above false ceiling or below false flooring, to give repeat indication of the state of that particular detector. | 352 | 5 | EA |
353 | 3540 | Miscellaneous | 353 | ||
354 | 3550 | Installation, Configuration, Integration, Testing and Commissioning of flameproof cum weather proof to IP 65 or better SIL 2 smart pressure transmitter with in built display, SS manifold, isolation valve, other erection material etc as per hook up drawing attached else where in tender complete as per specifications and Tender Document. (Transmitter will have IEC & ATEX certified minimum and any other certification as stated elese where in tender) | 354 | ||
355 | 3560 | TLF pump Suction end | 355 | 14 | EA |
356 | 3570 | TLF pumps Discharge end | 356 | 14 | EA |
357 | 3580 | Installation, Configuration, Integration, Testing and Commissioning of flameproof cum weather proof to IP 65 or better SIL 2 Smart Differential pressure transmitter with in built display, SS 3 way manifold, other erection material etc as per hook up drawing attached else where in tender complete as per specifications and Tender Document. (Transmitter will have IEC & ATEX certified minimumand any other certification as stated else where in tender) | 357 | ||
358 | 3590 | Across all TLF pump strainers | 358 | 14 | EA |
359 | 3600 | Installation, Configuration, Integration, Testing and Commissioning of Wailing siren along with controller with a provision to operate locally as well as from control room, mounting accessories etc complete as per specification and tender document. | 359 | 1 | LS |
360 | 3610 | Installation, Configuration, Integration, Testing and Commissioning of Ex-proof and weather proof Hooter cum Beacons along with accessories, mounting structure etc complete as per specification and tender document for audio visual alarm at field in case the MOVs installed at tank dyke drain and tank water draw off line is not fully closed. \nLocation : Near each tank dyke to be installed outside dyke. | 360 | 3 | EA |
361 | 3620 | Installation of MCT block for entire Automation cable entry to Control Room, Admin Building, Invoice Room, Security Room, S&D, Driver's Rest Room with minimum 30% spare MCT blocks for furture cable entry alongwith frame and mounting accessories complete as per specification and tender document. | 361 | 1 | LS |
362 | 3630 | Cabling, JB, Earthing | 362 | ||
363 | 3640 | Laying, glanding, ferruling, termination of all types of cables (Signal , Power, Control, Cat 6, OFC, earthing cables etc excluding power cables for free issue items as mentioned in tender document), LAN face plate, Exd/FLP and Non FLP Junction Boxes( Power, Signal and Control) along with accessories like certified double compression cable glands with PVC shrouds & plugs for excess entries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners etc , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), conduits, HDPE pipes, structural steel for mounting of equipments, GI Strips, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc required for cabling of below mentioned System, Subsystems, equipments & any other equipments not mentioned below but are required as per tender & BOQ requiremnt for complete Automation & integration with TAS complete as per specification and tender document: \n | 363 | ||
364 | 3650 | Complete TLF Automation System for integration of field equipments comprising of Mass Flow meters, Temperature Transmitter with RTD, Differential Pressure Transmitter across strainer, DCV, On-Off valve, Bottom Loading arm parking Position sensor, Rack Monitors, Earthing Relay/ Grounding Units, RIT, Driver's Ack PBS, Batch Controller, pump demand & ESD control cables from respective BCU to PLC, Proximity card readers, Layer 2 switches, Pump demand signals, FLP Sockets at alternate bays, Header line instruments (Pressure transmitter, ESD PBS (Local & Plant ESD at gantry and other places as specified in the tender), Power ESD to PMCC & TAS PDB, Ethanol blending system, Additive dosing system, Barrier gates along with accessories & PCR, Proximity card readers & single line LED display for TT registration, Bay Queue display board along with accessories, LED display screen at lock shed & Driver’s rest room, LED display board at license area Entry barrier Gate for displaying allocated bay to TT, status of activation of FLP push button station installed to manually stop respective product pumps, any other equipments supplied and installed for complete Tank Truck Automation System. | 364 | 1 | LS |
365 | 3660 | Complete Automation and integration of Tank Farm Management System for A/G product & Ethanol tanks, U/G product & Ethanol tanks, Fire Water Tanks, U/G static water sump tank, U/G service water sump tanks, Day tanks for Fire Engines & DG sets, Day tank & Mother tanks of Foam System, Sludge tanks, Additive & Blue dye tanks etc comprising of Primary Radar Gauges, Secondary Radar gauges, MSTW, PT for density measurement, Tank side indicators, AOPS, density probes, level switches (Hi & Lo), DPT calibrated for level measurement, any other equipments supplied and installed for complete Tank farm Management System | 365 | 1 | LS |
366 | 3670 | Complete Automation and integration of Hydrocarbon Gas Detection system along with hooter & Beacons | 366 | 1 | LS |
367 | 3680 | Complete Automation and integration of Fire detection and alarm System, Wailing Siren including integration of PA paging system with TAS | 367 | 1 | LS |
368 | 3690 | Complete Automation and integration of all the product loading & unloading pumps (TLF, TW), Ethanol pumps, additive pumps, blue dye pumps, agitators, submersible pumps for U/G product tanks, static water & service water sump tanks, sludge pumps, VFD for TLF loading pumps, TT calibration pumps and any other pumps mentioned in BOQ and tender requirement | 368 | 1 | LS |
369 | 3700 | Complete Automation and Integration of PT installed at TLF product pump suction & Discharge end; DPT installed across TLF pump strainer; level switch installed at static water sump, underground static water sump and TT calibration sump. | 369 | 1 | LS |
370 | 3710 | Complete Automation and Integration of hooter cum beacons installed outside dyke for dyke drain valve & water draw off line. | 370 | 1 | LS |
371 | 3720 | Complete integration and control of ROSOVs, DBBVs, MOVs, SOVs, Master Control Station for MOVs & DBBVs along with Local Push button station for local operation of the valves from outside dyke wall. | 371 | 1 | LS |
372 | 3730 | Complete integration of TAS equipments installed at Control room,Panel room(including UPS and battery), S&D, Security Gate/Room, Lock room, TM room, Driver rest room along with inter building redundant LAN cabling over OFC from Control Room to respective buildings - S&D, Security room, Lock Room, Admin Building, Driver rest room, and any other places complete as per tender requirement | 372 | 1 | LS |
373 | 3740 | Complete LAN cabling for IOCL intranet network inside Admin Building, Control Room, S&D, Invoice room, Lab building along with LAN face plate. \nCabling to be done from all LAN face plate to respective LAN switches and from all LAN switches to main Layer 2 switches at S&D room.\nTotal nos of LAN points to be provided shall be as follows: \nControl Room : 16 Nos. \nAdmin Building 36+16= 52 Nos.\nS&D : 9 nos.\nInvoice Room : 6 Nos. \nLab building : 5+5 = 10 Nos.\nInterbuilding connectivity between switches to be done over OFC cables and LAN cabling inside building shall be done using CAT 6 cables inside PVC conduits with proper support above false ceiling, below false flooring etc as per requirement. | 373 | 1 | LS |
374 | 3750 | Fabrication, cutting, layiong and connecting of GI strip along with accessories etc for interconnecting Earth pits, connecting UPS and other equipment / panel with earth pit, TLF gantry in two layers with isolators for TT earthing, connecting earthing bus bar etc required for complete Terminal Automation System as per Standard Design Engineering, specification and tender document. | 374 | 1 | LS |
375 | 3760 | Earth Pit | 375 | ||
376 | 3770 | Installation, Testing and Commissioning of Maintenance Free CPRI approved Earth pit ( Ashlok /Equivalent make ) as per IS : 3043 with 100 mm dia of minimum 3mtr length T45 model/equivalent safe earthing electrode with Pipe-in-pipe technology consisting of two mild steel pipes one inside the other, hot dip galvanized (80-100 microns), filled with high conductive & corrosion resistance crystalline mixture and backfilling compound around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Procedure recommended by chemical earth supplier and IS code to be finally adopted. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation \nAll Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification) | 376 | ||
377 | 3780 | CCTV system | 377 | 5 | EA |
378 | 3790 | TLF gantry | 378 | 2 | EA |
379 | 3800 | TT earthing | 379 | 2 | EA |
380 | 3810 | Control room | 380 | 4 | EA |
381 | 3820 | Pump house | 381 | 2 | EA |
382 | 3830 | SIL verification / Validation | 382 | ||
383 | 3840 | SIL verification from approved third party agencies. (For SIFs as per SIL Assessment study report/detail engg). All required documentation as per specs and other documentation mentioned elsewhere in tender scope has to be submitted. Complete as per specification / tender documents. | 383 | 1 | LS |
384 | 3850 | Validation of entire Safety System (SIS) for SIFs (for e.g. AOPS -SIF) shall be carried out from approved third party agency prior to trial period. Automation contractor shall bear the responsibility of its co-ordination and logistics. The third party has to submit a detailed report along with certification for SIS which is to be approved by IOCL along with all other required documentation as per specification and tender documents. | 384 | 1 | LS |
385 | 3860 | Services for Safety Instrumented System testing after installation in presence of safety, operation and engg. Team from user. Demonstration of safety system during pre OISD / OISD & statutory audits & there after periodic testing. Complete as per specifications / tender documents. | 385 | 1 | EA |
386 | 3870 | Other Services | 386 | ||
387 | 3880 | Providing training to IOCL employee as per schedule/Module for 2 days as per tender document | 387 | 1 | Module |
388 | 3890 | Submission of detailed system design, Engineering, Documentations etc as per tender document | 388 | 1 | LS |
389 | 3900 | Submission of Final Detailed system design, Engineering, Documentations etc complete as per tender | 389 | 1 | LS |
390 | 3910 | Resident Engineer support on yearly basis in case of shift addition during CAMC period | 390 | 1 | Shift |
391 | 3920 | Design, development, modification, configuration, testing and commissioning of existing TAS software, PLC logic, GUI etc for implementation of following features after FAT (if required) or during CAMC period as stated in tender document. The job includes necessary tro-& fro travel, lodging, boarding, food etc required for implementation at site complete in all respect and as per direction of EIC. | 391 | ||
392 | 3930 | Loading point additon | 392 | 1 | per LP |
393 | 3940 | Product pump addition | 393 | 1 | per pump |
394 | 3950 | Product tank addition | 394 | 1 | per tank |
395 | 3960 | Product addition | 395 | 1 | per product |
396 | 3970 | Installation and commissioning of redundant Master control station for MOV/DBBV for stand alone operation and interfacing with PLC for remote operation complete in all respect as per specifications. | 396 | 1 | EA |
397 | 3980 | Items mentioned below under this heading shall be Applicable only when there is deviation in quantity due to variation in given facilities/equipments) | 397 | ||
398 | 3990 | Cables Applicable only when there is deviation in quantity due to variation in given facilities/equipments) | 398 | ||
399 | 4000 | Laying, glanding, ferruling and termination of FRLS Armoured Copper Power cable as per tender specifications. | 399 | ||
400 | 4010 | 3C x 2.5 sqmm | 400 | 10 | RM |
401 | 4020 | 3C x 4 sqmm | 401 | 10 | RM |
402 | 4030 | 3C x 6 sqmm | 402 | 10 | RM |
403 | 4040 | 4C x 2.5 sqmm | 403 | 10 | RM |
404 | 4050 | 4C x 4 sqmm | 404 | 10 | RM |
405 | 4060 | 4C x 6 sqmm | 405 | 10 | RM |
406 | 4070 | 4C x 10 sqmm | 406 | 10 | RM |
407 | 4080 | Laying, glanding, ferruling and termination of FRLS Armoured Copper Control cable as per tender specifications. | 407 | ||
408 | 4090 | 2C x 1.5 sqmm | 408 | 10 | RM |
409 | 4100 | 3C x 1.5 sqmm | 409 | 10 | RM |
410 | 4110 | 4C x 1.5 sqmm | 410 | 10 | RM |
411 | 4120 | 6C x 1.5 sqmm | 411 | 10 | RM |
412 | 4130 | 8C x 1.5 sqmm | 412 | 10 | RM |
413 | 4140 | 10C x 1.5 sqmm | 413 | 10 | RM |
414 | 4150 | 12C x 1.5 sqmm | 414 | 10 | RM |
415 | 4160 | 16C x 1.5 sqmm | 415 | 10 | RM |
416 | 4170 | 24C x 1.5 sqmm | 416 | 10 | RM |
417 | 4180 | 32C x 1.5 sqmm | 417 | 10 | RM |
418 | 4190 | 48C x 1.5 sqmm | 418 | 10 | RM |
419 | 4200 | 60C x 1.5 sqmm | 419 | 10 | RM |
420 | 4210 | Laying, glanding, ferruling and termination of FRLS Armoured Copper Signal cable as per tender specifications. | 420 | ||
421 | 4220 | 1P x 1.5 sqmm | 421 | 10 | RM |
422 | 4230 | 2P x 1.5 sqmm | 422 | 10 | RM |
423 | 4240 | 6P x 1.5 sqmm | 423 | 10 | RM |
424 | 4250 | 8P x 1.5 sqmm | 424 | 10 | RM |
425 | 4260 | 12P x 1.5 sqmm | 425 | 10 | RM |
426 | 4270 | 1T x 1.5 sqmm | 426 | 10 | RM |
427 | 4280 | 8T x 1.5 sqmm | 427 | 10 | RM |
428 | 4290 | Laying, glanding, ferruling and termination of FS Armoured Copper Power cable as per tender specifications. | 428 | ||
429 | 4300 | 3C x 2.5 sqmm | 429 | 10 | RM |
430 | 4310 | 3C x 4 sqmm | 430 | 10 | RM |
431 | 4320 | 3C x 6 sqmm | 431 | 10 | RM |
432 | 4330 | 4C x 2.5 sqmm | 432 | 10 | RM |
433 | 4340 | 4C x 4 sqmm | 433 | 10 | RM |
434 | 4350 | Laying, glanding, ferruling and termination of FS Armoured Copper Control cable as per tender specifications. | 434 | ||
435 | 4360 | 2C x 1.5 sqmm | 435 | 10 | RM |
436 | 4370 | 3C x 1.5 sqmm | 436 | 10 | RM |
437 | 4380 | 4C x 1.5 sqmm | 437 | 10 | RM |
438 | 4390 | 12C x 1.5 sqmm | 438 | 10 | RM |
439 | 4400 | 16C x 1.5 sqmm | 439 | 10 | RM |
440 | 4410 | 24C x 1.5 sqmm | 440 | 10 | RM |
441 | 4420 | 32C x 1.5 sqmm | 441 | 10 | RM |
442 | 4430 | Laying, glanding, ferruling and termination of FS Armoured Copper Signal cable as per tender specifications. | 442 | ||
443 | 4440 | 1P x 1.5 sqmm | 443 | 10 | RM |
444 | 4450 | 2P x 1.5 sqmm | 444 | 10 | RM |
445 | 4460 | 6P x 1.5 sqmm | 445 | 10 | RM |
446 | 4470 | 8P x 1.5 sqmm | 446 | 10 | RM |
447 | 4480 | 12P x 1.5 sqmm | 447 | 10 | RM |
448 | 4490 | 1T x 1.5 sqmm | 448 | 10 | RM |
449 | 4500 | 8T x 1.5 sqmm | 449 | 10 | RM |
450 | 4510 | Laying, Testing and Commissioning of 6 core single mode armoured optical fibre cable as per tender specifications and instructions of Engineer in charge. | 450 | 10 | RM |
451 | 4520 | Laying, termination , glanding, Testing and Commissioning of CAT 6 Ethernet armoured cable as per tender specifications and instructions of Engineer in charge. | 451 | 10 | RM |
452 | 4530 | Laying and termination of 1C x 6 Sq. mm Flexible copper insulated green wire for earthing instruments and junction boxes etc complete as per specification and tender document | 452 | 10 | RM |
453 | 4540 | Cable Trays .(Applicable only when there is deviation in quantity due to variation in given facilities/equipments) | 453 | ||
454 | 4550 | Laying of anodized Aluminium perforatedcable trays (2.5mm Thick and 25mm edge height) with tray covers (1.5mm Thick and 10mm edge height), alongwith with structural steel for mounting of the cable tray. Complete as per specifications / tender documents. | 454 | ||
455 | 4560 | 50mm | 455 | 10 | RM |
456 | 4570 | 100 mm | 456 | 10 | RM |
457 | 4580 | 150 mm | 457 | 10 | RM |
458 | 4590 | 300 mm | 458 | 10 | RM |
459 | 4600 | Junction Boxes (Applicable only when there is deviation in quantity due to variation in given facilities/equipments) | 459 | ||
460 | 4610 | Installation of Exd/FLP Junction Box (Power/Control/Signal JB) with IP 65 as per specification suitable for hazardous area of zone 1, group IIA/IIB, T3 or better having CCOE/CMRI approval. It shall be complete in all respect. Accessories like certified double compression cable glands with PVC shrouds & plugs for excess entries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners. Complete as per specification / tender documents.. | 460 | ||
461 | 4620 | 24 way control JB | 461 | 5 | Ea |
462 | 4630 | 18 way control JB | 462 | 10 | Ea |
463 | 4640 | 12 way control JB | 463 | 10 | Ea |
464 | 4650 | 8 way control JB | 464 | 10 | Ea |
465 | 4660 | 6 way control JB | 465 | 10 | Ea |
466 | 4670 | 4 way control JB | 466 | 10 | Ea |
467 | 4680 | Laying, jointing, connection, testing and commissioning of hot dip GI earth strip ( 50 X 6) within earth station. Hot dip galvanizing (800 gm/m2 as per IS 4759) shall be done after all fabrication. (Applicable only when there is deviation in quantity due to variation in given facilities/equipments) | 467 | 10 | RM |
468 | 4690 | Laying of 50 mm HDPE pipe of minimum 2.5 mm thick along with accessories as per tender specifications and instructions of Engineer in charge. (Applicable only when there is deviation in quantity due to variation in given facilities/equipments) | 468 | 10 | RM |
469 | 4700 | CAMC | 469 | ||
470 | 4710 | 1st year | 470 | 1 | EA |
471 | 4720 | 2nd year | 471 | 1 | EA |
472 | 4730 | 3rd year | 472 | 1 | EA |
473 | 4740 | 4th year | 473 | 1 | EA |
474 | 4750 | 5th year | 474 | 1 | EA |
475 | 4760 | 6th year | 475 | 1 | EA |
476 | 4770 | 7th year | 476 | 1 | EA |