Housing Urban and Rular Development Government Departments Closing in 0 days TDR #21830263

Construction Of Fortified Police Station At Gudri In The District Of West Singhbhum .

Issued by Government Departments · Gudri, Jharkhand
Tender Value
2.14 Crore
Estimated cost
Bid Submission
30 Sep 2019
0 days left
EMD
4.29 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gudri → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Fortified Police Station At Gudri In The District Of West Singhbhum .

BOQ

Name of Work: Construction of Fortified Police Station at Gudri in the district of West Singhbhum.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Section- I Building Works1
225.1.1\nEarthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I.2390.598CUM
335.1.2 \nExtra for earth work in hard soil as per specification and direction of E/I.( vide classification of soil item B)3390.598CUM
445.1.8\nEarth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)4394.207CUM
555.1.10\nProviding coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)586.9221CUM
665.6.1\nProviding designation 75 A one brick flat soling joints filles with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I6788.859SQM
775.3.3\nProviding P.C.C.M 100 in normal mix of (1:3:6) in foundation with approved quality of stone metal grade II (50mm to 25mm size) clean coarse sand to F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I763.1961cum
885.3.8.1\nProviding RCC M-200 with nominal mix of (1:1.5:3) in lintel with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.86.01064CUM
995.3.7.1\nProviding R.C.C.M 200 (1: 1.5: 3) in Band at Lintel level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I94.44062Cum.
10105.2.3\nProviding designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.1035.7292Cum.
11115.3.16.1\nProviding 25mm thick damp proof course with cement concrete M-200 with nominal mix of (1:1:5:3) with approved quality of stone chips of 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, and mixing cement concrete in mixer with 5% cico or any other approved water proffing compound and placing in position, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.1125.2sqm
12125.3.5.1\nProviding RCC M-200 with nominal mix of (1:1.5:3) in foundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.1261.936CUM
13135.3.14\nProviding R.C.C.M 200 with nominal mix (1:1.5: 3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, ( but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I1339.6018Cum.
14145.3.6.1\nProviding R.C.C.M 200 with nominal mix (1: 1.5: 3) in Band at plinth level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, ( but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I1434.4881Cum.
15155.3.11\nProviding RCC M-200 with nominal mix of (1:1.5:3) in beam of all types with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.1583.4978CUM
16165.3.9.1\nProviding RCC M-200 with nominal mix of (1:1.5:3) in roof slab with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.16133.266CUM
17175.3.18.1\nProviding RCC M 200 (1:1.5:3) in stair case with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.176.8346CUM
18185.3.15.1\nProviding Av. 63 MM thk M200 With nominal mix in Chajja..(1:1.5:3) Chajja with apporoved quality ofstone chips 20 mm to 6 mm size graded and cleane coarse sand of FM. 2.5 to 3 including making drips course in concrete , sereening centering shuttring and mixing cement concrete in mixer and placing in posotion vibrating striking 6 mm cemet plaster 1:4 in ceiling and side of chajja with sand of FM. 1.5 curing (but excluding the cost of reinforcement ) taxes and royalty sll complere as per building specefication and direction of E/I1843.9954SQM
19195.3.17.1\nProviding R.C.C M-150 with with nominal mix of (1:1.5:3) shelves with apporoved quality of stone chips 12 mm to 6 mm size graded and cleane coarce sand of FM 2.5 to 3 with 1.5 mm cement punning at top and side and 6 mm cement plaster (1:4) at bottom including screening curing and placing the slab in in position taxes and royalty all complete as per building specefication ad direction of E/I1962.655SQM
20205.2.14\nProviding designation 75A brick work in CM (1:6) in superstructure with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.20249.272CUM
21215.2.23\nProviding designation 125mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse & of F.M. 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.21588.178CUM
22225.7.3\nProviding 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I223563.66SQM
23235.7.6\nProviding 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.231034.41SQM
24245.5.5\nProviding Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. \n8 mm dia - TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)248.3253MT
25255.5.5a\n\n10mm dia - TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)254.16265MT
26265.5.5b\n12mm dia - TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)268.3253MT
27275.5.5c\n16 mm dia - TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)2712.4879MT
28285.5.5d\n20 mm dia - TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)288.3253MT
2929DSR 10.18\nProviding and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mmdia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing.2952Each
30305.7.21\nMaking 6x6 mm Groove in plaster surface over walls trully horizantal and vertical as specified as regular interval , at all heights including claening finishing scaffoolding and curing with all leads and lifts of water all complete as per building specification and direction of E/I.30769m
3131DSR 13.80\nProviding and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.314791.04SQM
3232DSR 13.46.1\nFinishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer\napplied @ 2.20 kg/ 10 sqm)321652.43Sqm
33335.8.18\nProviding two coats of oil bound distemper of approved make & shade over a coat of cement primer over new surface including preparing the plastered surface by rubbing, smooth with pumic stone or fine sand paper, aplying putty wherever required, scaffolding , washing of flores and taxes etc. all complete as per building specification direction of E/I.333189.57SQM
3434DSR 22.22A\nProviding and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The\noperation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in\nall respect as per the direction of Engineer-in-Charge.34613.274Cum
3535JSR 2018 page no.32 sl no 55 (ii)\nProviding & supplying Cico liquid / impermo water proofing compound in cement concrete or cement mortar @ 2% of cement quqntity by weight ( as specified) for water proofing, including all carraige and taxes .3550Ltr.
3636DSR 22.5\nProviding and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation\nof surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.3683.2671sqm.
3737DSR 10.28\nProviding and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fastenersetc.).37699.582Kg
3838DSR 12.41.2\nProviding & fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. Single socketed pipes. 110mm dia3851.5M
393912.42\nProviding & fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion39
404012.42.5.2\nBend -110 mm408NOS
414112.42.6.2\nShoe - 110mm418NOS
4242Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.4230NOS
43435.10.33\nProviding 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of earthwok involved with 75mm cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at th base, he drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.43123.526M
4444DSR 4.17\nMaking plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.4474.1157sqm
454521.1\n Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :45
464621.1.2 \nFor shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)\n21.1.2.3 Polyester powder coated aluminium\n(minimum thickness of polyester powder\ncoating 50 micron)46687.306sqm
474721.3\nProviding and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be\npaid in basic item):\n21.3.1 With float glass panes of 4.0 mm thickness47106.46sqm
4848DSR 9.119\nProviding and fixing factory made P.V.C. door frame manufactured by M/s Rajshri or equivalent of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers speci fication and direction of Engineer-in-Charge.-4896.9m
4949DSR 9.120.2\nProviding and fixing 30 mm thick factory made PVC rigid foam panelled door shutters manufactured by M/s Rajshri or equivalent made from M.S. tube of 19 gauge thickness, size 19 x 19 mm for styles and 15 x 15 mm for top and bottom rails, covered with heat moulded PVC \"C\" channel of 5 mm thick and 75 mm wide PVC sheets for top rail, lock rail and bottom rail on either side and 5 mm thick, 20 mm wide cross PVC sheet as gap insert for top rail and bottom rial, panelling of 5 mm thick PVC sheet fitted in the M.S. frame welded/ sealed to the styles and rails with 5 x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineer-in-Charge fixed to frames with 4 Nos. M.S. powder coated butt hinges (For W.C. and bathroom shutters).4935.91sqm.
50505.5.12\nSupplying , fitting and fixing M.S. grill made of 20x6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted welded and finished smooth , hoisting as per building specification and direction of E/I.501900.26Kg.
5151DSR\n10.14\nProviding and fixing pressed steel door frames conforming to IS: 4351 manufactured from commercial mild steel of 1.60 mm thickness including hings , jamb , lock jamb, bead and if required angle threshold of mild steel angle od section 50x25mm or base ties of 1.60 mm pressed mild steel welded or rigidly togather by mechnical means including M.S pressed butt hiongs 2.5 mm thick with mortar guards , lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre treatment of the surface as directed by Engineer - in-charge. Profile B51
525210.14.1.1\nFixing with adjustable lugs with split end tail to each jamb52140.759Mtr
53535.4.34\nSupplying, fitting & fixing 30mm thick solid core type decorative single leaf flush door shutters in doors with both side decorative venier with black board core bended with high quality in all formaldehyde synthetic resin of standered with aluminium fittings such as hinges, tower bolts, handle, cleats aldrop, door stopper & sand blocks & taxes all complete as per detail drawing building specification & direction of the E/I.5359.09Sqm
545411.41/ D.S.R \nProviding and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete\n11.46.3 Size of Tile 800x800 mm54472.104Sqm
5555D.S.R 11.46 \nProviding and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.\n11.46.3 Size of Tile 800x800 mm\n5518.7276Sqm
565611.56/ D.S.R \nProviding and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white\ncement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.\n11.56.1\n Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.56256.073Sqm
575711.39/ D.S.R \nProviding and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4\nCoarse sand), including grouting the joints with white cement and matching pigments etc., complete.57110.462sqm
5858DSR 8.31\nProviding and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.58782.418sqm
5959DSR 8.2.2.2\nProviding and fixing 18mm thick mirror polished, machine cut for kitchen platforms, vanity counters facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 Cement : 4 coarse sand) with joints treated with white cement ,mixed with matching pigment, epoxy touch ups, including rubbing ,curing etc. complete at all levels. GRANITE OF ANY COLOUR AND SHADE -Area of slab Over 0.5 sqm .597.44097sqm
6060DSR 8.3\nProviding edge moulding to 18 mm thick marble stone counters, Vanitiesetc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.\n8.3.2 Granite work6011.407Mtr.
61615.6.19\nProviding and laying 15 mm - 23mm thick Kotah stone slab riser steps of approved size, texture and colour over 19 mm thick base of lime morter (1:1:1 ) lime putty:surkhi:coarse sand over and jointed with gray cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete job as per specifications and direction of E/I. \n(iv) 600 x 600 mm size6173.7251sqm
6262DSR 13.68\nFrench spirit polishing :\n13.68.1 Two or more coats on new works including a coat of wood62132.953m2
63635.8.41\nProviding primer one coat of red lead paint ofapproved make over steel surface including preparing the surface after cleaning removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification direction of E/I.63145.169SQM
64645.8.45\nProviding 2 coats of Synthetic Enamel Paint of approved shade and make over steel surface grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.64145.169sqm
6565DSR 8.2\nProviding and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement\nmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.\n8.2.1\n Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble6532.5734Mtr.
6666DSR 25.2 \nDesigning, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:66
6767(a) \nStructural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, icrowave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:67
6868(b) \nFabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.68
6969(c) \nProviding and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.69
7070(d) \nProviding and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.70
7171(e) \nMaking provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.71
7272Note:- 1. \nThe cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.72
7373Note:-2. \nThe following performance test are to be conducted\non structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science &Technologies, India. Cost of testing is payable separately.73
7474The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO /IEC 17011 and accredits labs as per ISO/ IEC 17025.74
75751. \nPerformance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr\n2. \nStatic Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml.\n3. \nDynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml\n4. \nStructural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm75
76765. \nSeismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site.\n6. \nOnsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml7613.383SQM
777716.68 \nProviding and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.7746.4684SQM
7878Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.78
7979Bricks (1K+ 45 P = 46 KM.)79151.73No.
8080Local Sand (3 KM.)8018.7163Cum
8181Coarse Sand (1k+11P=12 KM.)81366.331Cum
8282Chips (45) km82392.968Cum
8383Cement (45KM.)83213.257Cum
8484Steel ( 45 KM.)8441.6265Cum
8585Earth( 1 km)85394.207Cum
8686Sanitary Installation Work86
87873.2.1\nSupplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'P' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/ P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50 grms, 15mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specificatin and direction of E/I. \n(A) 580 mm long \n(C) with 12.50 ltrs. low level P.V.C. Cistern876EACH
88883.2.2\nSupplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C with Ptrap of parry/Hindustan or any other approved I.S.S make ineluding supplying and fixing 15 liters C.I mosquito proof low down flushing cistern of approved make with complete fittings with C.I handle and R.S or bracket wit h telescopic flush pipe with brass eoupling and plumbers joints spindle stop coci of approved quality weight not less than 450grams 15mm P.V.C alkathene pipe 45cm long with brass coupling at both ends and white /black plastic solid state seal and lead of commander / cuckoo or other I.S.S make with hinges or screws etc painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I. \n(I) With 'P' trap\n(b) 12.5 Lit Law Lavel PVC Cistern.887EACH
8989DSR 17.7\nProviding and fixing wash basin with C.I. brackets, 15 mm C.P. brass\npillar taps, 32 mm C.P. brass waste of standard pattern, including\npainting of fittings and brackets, cutting and making good the walls\nwherever require:\n17.7.9 White Vitreous China Surgeon type wash basin of size\n660x460 mm with single 15 mm C.P. brass pillar taps\nwith elbow operated levers ISI Marked8919EACH
9090DSR 17.8\nProviding and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.9019EACH
9191DSR 17.70\nProviding and fixing PTMT Bottle Trap for Wash basin and sink. \n17.70.1 Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms915EACH
9292DSR 18.52.1\nProviding and fixing C.P. brass Stop Cock (concealed) of standard designand of approved make conforming to IS 8931. \n18.52.1 15mm nominal bore928EACH
9393DSR 18.64 \nProviding and fixing PTMT swivelling shower, 15 mm nominal bore,\nweighing not less than 40 gms9311EACH
9494DSR 17.72\nProviding and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.9416EACH
9595DSR 17.73\nProviding and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.\n17.73.1 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms9512EACH
96963.2.3\nSuppling, Fitting and Fixing Flat Back or angular, liped front viterous wide glazed earthen were urinal of Hindustan / Parrywere or any other approved ISI marked with 5 litres capacity C.I. automatic flushing cistern of reliance for any other ISI approved make with all fittings with CI or RS Brackets, Standard Size G.I. flush pipe with fitting clams 15mm CI buddy brass spindle stop cock of approved quality weight not less than 400 grms, 15 mm PVC / alkthene pipe 450 mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint over a primer coat of red oxide cutting wall and floor, making good the same etc. all complete as per specification and direction of E/I.\n(a) Flat back or standing corner (600mm x 350mm)968EACH
9797D.S.R 18.50\nProviding and fixing C.P.brass long body bib cock of approved quality conforming to standard and weight not less thain 810gms.97
989818.50.1 15mm nominal bore9813EACH
9999D.S.R. 18.53\nProviding and fixing C.P. brass angle valve for , gyser & others points of approved quality conforming to IS 8931. \n18.53.1 15mm nominal bore, approved brand C.P. fittings.9964EACH
100100DSR 18.65\nProviding and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.10029EACH
101101D.S.R. 18.17 \nProviding and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end )101
102102DSR 18.17.2\n32 mm nominal bore.1024EACH
103103D.S.R. 18.18 \nProviding and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete.103
104104DSR 18.18.2\n20mm nominal bore1044EACH
105105DSR 18.18.3\n25mm nominal bore1054EACH
106106DSR 17.31\nProviding and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.10619EACH
107107DSR 18.58\nProviding and fixing PTMT grating of approved quality and colour.107
108108DSR 18.58.2 \nRectangular type with openable circular lid\nDSR 18.58.2.1\n150 mm nominal size square 100 mm diameter of the inner hinged round grating10835EACH
109109DSR 17.10\nProviding and fixing stainless steel A ISI 304(18/8) kitchen sink as per I.S.13983 with C.I. Brackets stainless steel plug 40mm including painting of fittings and brackets cutting and making goods the walls wherever required :\nDSR 17.10.1 \nKitchen sink with drain board\nDSR 17.10.1.2\n510x1040 mm bowl depth 225 mm1092EACH
110110DSR 18.74\nProviding and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.\n18.74.2 15 mm nominal bore with 45 cm length.11064EACH
111111DSR 17.22B\nProviding and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.\n(a) 15 mm nominal dia\n11111EACH
112112DSR 12.41 \nProviding and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,\n(i) Single socketed pipes.112
11311312.41.1 75 mm diameter11350M
11411412.41.2 110 mm diameter11490M
115115D.S.R 12.42 \nProviding and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.115
116116DSR 12.42.1.1 \nCoupler 75 mm11625EACH
117117DSR 12.42.1.2\nCoupler 110 mm11735EACH
118118DSR 12.42.2 Single pushfit Coupler118
119119DSR 12.42.2.1\n75 mm11915EACH
120120DSR 12.42.2.2\n110 mm\n12025EACH
121121DSR 12.42.3 Single tee with door121
122122DSR 12.42.3.1\n75 X 75 X 75 mm12215EACH
123123DSR 12.42.3.2\n110 X 110 X 110 mm12325EACH
124124DSR 12.42.4\nSingle tee without door124
125125DSR 12.42.4.1 \n75 X 75 X 75 mm12515EACH
126126DSR 12.42.4.2\n110 X 110 X 110 mm12625EACH
127127DSR 12.42.5\nBend 87.5°127
128128DSR 12.42.5.1 75 mm Bend12825EACH
129129DSR 12.42.5.2\n110 MM Bend12925EACH
130130D.S.R. 12.42.6 \nSHOE - 110MM130
13113112.42.6.1 75 MM13110EACH
13213212.42.6.2 110 MM Shoe13210EACH
133133D.S.R.12.43 \nProviding and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.133
134134DSR 12.43.1\n75 mm13433EACH
135135DSR 12.43.2\n110 mm13577EACH
136136DSR 18.8\nProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I.(Approved Brand - ASTRAL/ SUPREME)136
137137Concealed work including cutting chases and making good the wall etc..137
138138DSR 18.8.1.\n15mm dia13865M
139139DSR 18.8.2.\n20mm dia13980M
140140DSR 18.7\nProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.140
141141Exposed on Wall141
142142DSR 18.7.3\n25 mm nominal outer dia Pipes14265METER
143143DSR 18.7.4\n32 mm nominal outer dia Pipes143100METER
144144DSR 19.6\nProviding and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete.144
145145DSR 19.6.2\n150 mm dia R.C.C. pipe145100METER
146146D.S.R. 19.30\nConstructing brick masonary chamber for Underground C. I. Inspection Chamber and bend with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. Cover with frame (light duty) 455X610 mm internal dimensions, total weight of cover with frame to be not less than 38 KG. (weight of cover 23 kg. and weight of frame 15 kg) RCC top slab with 1:1.5:3 mix (1 cement:1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 mix (1 cement:5 coarse sand :10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm th. with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:146
14714719.30.1.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.514720EACH
148148Analysed and Approved\nProviding and Fixing Hand Shower ( Health Faucet) ( ABS Body) ALD-CHR-585 Jaquar made. Hand Shower with 1 meter Long Easy Flex Tube in Chrome Finish & Wall Hook.1487EACH
149149Analysed and Approved\nPvc trap including all fittings\n14960EACH
150150D.S.R/18.48 \nProviding and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.1508000LTRS
151151Septic tank151
152152(89) 5.1.1\nEarth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing ro15246.186Cum.
153153(90) 5.1.2\nExtra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)15346.186Cum.
154154(91) 5.1.10\nProviding coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as pe1541.401Cum.
1551555.3.2.\nProviding P.C.C.M 150 in normal mix of (1:2:4) in foundation with approved quality of ston chips 20mm to 6 mm size graded and clean coarse sand to F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in positi1552.803Cum.
156156(92)5.6.1\nProviding designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I15617.64Sqm
1571575.2.2\nProviding designation 75A brick work in C.M (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curri1579.833cum
158158(95) 5.2.23\nProviding designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out1586.9Sqm
159159(94) 5.3.9(ii)\nProviding R.C.C.M 200 with nominal mix of (1: 1.5: 3) in roof slab with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer an1591.816Cum.
160160(94) 5.3.11\nProviding R.C.C.M 200 nominal mix of (1:1.5: 3) in beam of all types with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placi1600.39Cum.
161161(94) 5.7.2\nProviding 12mm thick cement plaster (1:4) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I16154.7Sqm
162162(94) 5.7.11\nProviding 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.16281.85Sqm
163163Basic Rate of JSR Page no 20 item no- 7\nProviding and laying brick bats in soakpit with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I.1634.945Cum
164164(5.5.4\nProviding Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet1640.1M.T.
1651655.5.5\nProviding Tor steel reinforcement of 10mm , 12mm & 16mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in positio165
166166(a) 10 mm TMT bar FE 500 ( Only Valid for SAIL & TATA Steel )1660.089M.T.
167167(98) JPHCL approved rate\nprovding and laying of 110mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc.(SUPREME S.W.R.).1676M
168168(99) Basic Rate of JSR Page no 42 item 26 (B)\nSupplying, fitting and fixing C.I. cover with frame for manhole and inspection chamber with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per building specific1684Each
169169Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.169
170170Bricks (1K+ 45 P = 46 KM.)1706.575%0 Nos.
171171Coarse Sand (1k+11P=12 KM.)1716.466Cum.
172172Chips (45) km1725.5276Cum.
173173Cement (45KM.)1732.944MT
174174Steel ( 45 KM.)1740.894MT
175175Section III 200x150xmm dia Deep bore Well With Pump set & electrification etc works.175
176176DW & SD \nBasic rate item no. 116\nSuppling all materisls labour and tools and cost of drilling 200mm x 165mm bore well in all kinds of soil and rock in rural area for installation of pump set with hydrolic DTH rig machine, all complete including suplying all materials tools, drilling rig, Air compressor and equipments, as well as fuel, lubricants and cost of transprtation of Rig machine and other vehicles up to the site.176
177177a) From 0.0M to 50.0 M belew G.L17750P/M
178178b) From 51.0 M to200.00 M belew G.L178100P/M
179179DW& SD \nBasic rate item no. 117(A)\nsupplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe itc including all taxes, VAT, Excise duty, freight charges with inspection charges etc as applicable, etc all complete job.17920P/M
180180DW& SD \nCleaning Flushing and devloping of drilled hole for testing the discharge of water development of bore well by continueous flow of water bu using heavy compresser upto satisfaction of E/I. To get uniterrupted flow of water free from sand and soil etc.1801Hr
181181DW & SD \nBasic rate item no. 117(B)\nSupplying and fitting M.S cap over 200mm dia casing pipe as per direction of E/I For safety of drilling bore including providing of guard for safety of the same till returned final.1811Each
182182DW & SD \nBasic rate item no. 120(II) Page no-44(i)\nSupplying 100 mm dia submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/ fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump.182
183183PM 1-2-2\nSubmersible Pump 150 mm dia ( with Bronze impeller) up to 8 stages 2.0 HP1831Each
184184Analysed & Approved \nSupplying complete panel board with all accessories ( starter 1 no, volt meter 1 no, amp meter 1 no,100 amp kit kat ( male & female ) all complete job.1841Each
185185DW & SD \nBasic rate item no. CB 1-3 Page no- 44(xi)\nSupplying 3 core flat flexible submersible cable with, copper conductor, PVC insulated and PVC sheathed.\n3 Core 4mm thick185130M
186186Analysed & Approved \n2no heavy duty clamp 40mm dia suitable for 200 mm dia pipe with all complete job.1862Each
187187DW & SD \nBasic rate item no. 9(K) (v) Page no 13\nSupplying & lowering 40mm da column G. I. pipe with all complete job.18770P/M
188188Approach road (20 mtr)188
1891893.16\nEmbankment construction with material obtained from borrow pits18960Cum.
1901905.1.10\nProviding coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as pe19025Cum.
1911915.6.2\nProviding designation 75 A one brick edge soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I191100Sqm
1921925.3.2.1\nProviding P.C.C.M 200 in normal mix of (1:1.5:3) in foundation with approved quality of ston chips 20mm to 6 mm size graded and clean coarse sand to F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in positi19213.5Cum.
193193Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.193
194194Bricks (1K+ 45 P = 46 KM.)1945.4%0 Nos.
195195Local Sand (3 KM.)19528.0021Cum.
196196Coarse Sand (1k+11P=12 KM.)1965.8Cum.
197197Chips (45) km19711.614Cum.
198198Cement (45KM.)1985.56MT
199199Concertina coil fencing (500'00\" ft)199
2002005.1.1\nEARTH WORK IN EXCAVATION IN FOUNDATION Trenches in hard soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I20022.68Cum.
2012013.3.3\nProviding P.C.C. M-10 with nominal mix of (1:3:6) in Foundation with approved quality of stone metal grade III (53 to 22.4 mm size) and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixture, placing in position, vibration, striking, curing, taxes and royalty all complete as per building specification & direction of E/I.20122.68Cum.
202202Approved basic rates of material item No. 29+ 10%C.P.\nSupplying of M.S.ANGLE OF 50X50X6 for support of Concertina wire including all carriage, taxes, all complete.2021.575Mt
2032035.5.24\nLabour for cutting of M.S. angle iron post to required length& fixing in column , one end spitted as fishtailed in length of 150mm complete as per building specification & direction of E/I.203140Each
2042045.5.23\nDrilling 6 mm dia holes M.S. angle iron for fixing of staples etc. as per building specification & direction of E/I.204700Each
205205Approved basic rates of material item No. 3 (b)+ 10%C.P.\nSuplying of galvonised barbed wire of 4 points, 2 ply 12 SWG, 150 apart for fencing.205375.92Kg
2062065.5.22\nLabour for fitting & fixing barbed wire fencing in six rows horizontal up to a height of 1.25 M & two diagonals including fixing of post in cement concrete at 2.5 M centres including cost of staples (but excluding the cost of cement concrete angle iron post its cutting & making holes ,nuts & bolts ) all complete as per building specification & direction of E/ I.206304.8Mtr
207207DSR16.53\nProviding and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)207457.2Mtr
2082085.8.41\nProviding primer one coat of red lead paint of approved make over steel surfce including preparing the surface after cleaning removing dust , dirt. Scales smokes & grease & cleaning the surface throughly including cost of scaffolding & taxes all complete as per building specification & direction of E/I. ( Mode of measurement of area shall be multiple by the co-efficient as indicated in building specification.)20856.6411Sqm
2092095.8.45\nProviding 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills& railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.20956.6411Sqm
210210Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.210
211211Coarse Sand (1k+11P=12 KM.)21110.6596Cum.
212212Chips (45) km21221.3192Cum.
213213Gate213
2142145.1.1\nEarth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.21412.978Cum.
2152155.1.2\nExtra for earth work in hard soil as per specification and direction of E/I.( vide classification of soil item B)21512.9778Cum.
2162165.1.10\nProviding coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)2160.7015Cum.
2172175.6.1\nProviding designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.2177.015Cum.
2182185.3.2\nProviding P.C.C.M 100 in normal mix of (1:3:6) in foundation with approved quality of stone metal grade II (50mm to 25mm size) clean coarse sand to F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I2180.7015Cum.
2192195.3.5.1\nProviding R.C.C.M 200 (1: 1.5: 3) in foundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing ( but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I2192.541Cum.
2202205.3.14\nProviding R.C.C.M 200 (1:1.5:3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I2202.21125Cum.
2212215.3.11\nProviding R.C.C.M 200 (1:1.5: 3) in beam of all types with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I2213.70925Cum.
2222225.2.3\nProviding designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.2224.97566Cum.
2232235.7.3\nProviding 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I22399.5807Cum.
224224DSR 13.46.1\nFinishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer\napplied @ 2.20 kg/ 10 sqm)22499.5807Sqm
225225(5.5.4\nProviding Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet2250.3M.T.
2262265.5.5\nProviding Tor steel reinforcement of 10mm , 12mm & 16mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in positio226
227227(b) 12 mm TMT bar FE 500 ( Only Valid for SAIL & TATA Steel )2270.25M.T.
228228(c) 16 mm TMT bar FE 500 ( Only Valid for SAIL & TATA Steel )2280.45M.T.
2292295.3.16.1\nSupplying,fitting and fixing 20 guage G.C.l. sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1\".2.4 ) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specrfication and direction of E/|22918.3188Sqm
2302305.8.41\nProvinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.)23036.6375Sqm
2312315.8.45\nProviding two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I23136.6375Sqm
232232Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.232
233233Bricks (1K+ 45 P = 46 KM.)2330.266No.
234234Coarse Sand (1k+11P=12 KM.)2346.33995Cum
235235Chips (45) km2357.954Cum
236236Cement (45KM.)2361.69Cum
237237Steel ( 45 KM.)2371Cum
238238Note:- OF MAKE\n (1)PVC insuleted copper conductor wire of make:-Havell's/Polycab/Anchor \n (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG\n (3) GI modular box of make -: Anchor/ Havells/Legrand/ \n (4)Switches/soket outlet for modular type:- Anchor (roma)/Havells(cabtree)Legrand\n (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:-Havell's/L&T/C&S\n (6)XLPE/PVC aramoured cable:-Havell's/Polycab/V-guard\n (7) LED ITTING FIXTURE -: Havells/Bajaj/Crompton (Model/as per E/I )\n (8) CEALING / WALL / EXHAUST FAN -: Havells / Bajaj / Usha / Crompton (Model/as per E/I )\n (9)OCTAGONAL POLE-: Bajaj/Philips/Surya\n (10) CHEMICAL EARTHING OF MAKE - TRUEPOWER EARTHING\n (11) CENTRALISED AIR CONDITIONING OF MAKE - VOLTAS/MITSHUBISHI/ \n TOSHIBA/DAIKIN\n (12)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED\n\n \n238
2392391.3\nPoint wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.239
2402401.3.1\nGroup A240108Point
2412411.3.2\nGroup B241112Point
2422421.4\nTwin control point wiring PVC conduit with modular type switch:-wiring for Twin control point with 1.5 sq mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, 2 way modular, switch, pheonlic lamineted sheet,suitable size G.I.box etc.as required.2423Point
2432431.5\nPower plug wiring in PVC conduit (2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.243498Metre
2442441.7\nCircuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required244
2452451.7.2\n2x2.5 sq mm+1x2.5 sq mm earth wire245616Metre
2462461.7.5\n2x10 sq mm+1x10 sq mm earth wire24647Metre
2472471.7.10\n4x6 sq mm+2x6 sq mm earth wire247220Metre
2482481.7.11\n4x10 sq mm+2x10 sq mm earth wire248198Metre
2492491.16\nTeliphone wiring existing conduit:- Supplying and drawing following pair 0.5 sq mmFR PVC insuleted copper conductor, unaramed teliphone cable in existing recessed PVC conduit as required249
2502501.16.3\n3 Pair250270Metre
2512511.17\nTV cable in existing conduit :- Supplying and drawing co-axial TV cable RG-6 grade copper conductor,PE insulated,with PVC sheath in the existing recessed PVC conduit as required.25190Metre
2522521.21\nS/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required .252
2532531.21.1\n20mm253310Metre
2542541.24\nS/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required254
2552551.24.1\n5/6 amps, one way switch25581Each
2562561.24.3\n15/16 amps, one way switch2568Each
2572571.24.4 \n5/6 amps, 3 pin socket outlet25781Each
2582581.24.5\n15/16 amp 6 pin socket outlet2588Each
2592591.24.7\nTeliphone socket with shutter outlet25914Each
2602601.24.8\nTV socket socket outlet2603Each
2612611.25\nS/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.26132Each
2622621.26\nS/F Modular type blanking plate:-Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc, as required.26220Each
2632631.27\nS/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.263
2642641.27.1\n1 or 2 module(78mm x 78mm x 45mm)26433Each
2652651.27.3\n6 module(78mm x 205mm x 50mm)26528Each
2662661.27.4\n8/9 module(78mm x 230mm x 60mm)2664Each
2672671.32\nS/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch conection painting etc, as required.26733Each
2682681.33\nS/F ceiling rose:-\nSupplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.268109Each
2692691.34\nS/F Batten holder:-\nSupplying and fixing batten/angle holder including connection etc, as required.2693Each
2702701.36\nS/F Dingdong Call bell :-\nSupplying and fixing dingdong call bell suitable for DC/AC single phase,230 volt, complete as required.2703Each
2712711.41\nITC fluorescent/LED fitting directly on surface:-\nInstaliation, testing and commissioning of prewired, fluorescent fitting of all types, complete with all accessosries and tube etc. directly on ceiling /wall including connection with 1.5 sq mm.FR PVC insulated, copper conductor.271142Each
2722721.44\nITC ceiling/wall fan:-\nInstaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required27259Each
2732731.48\nITC exhaust fan up to 450 mm, sweep:-\nInstallation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required.27317Each
2742742.8\nS/F S.P. MCB DB:-\nSupplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)274
2752752.8.8\n8 Way,Double door2751Each
2762762.9\nS/F T.P.MCB DB:-\nSupplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)276
2772772.9.4\n4 way (4+12),Double door, Horizontal type2778Each
2782782.11S/F 'B' series. S.P.MCB:-\nSupplying and fixing 6 amps to 32 amps rating,240 volts, 'B' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.278
2792792.11.1\n6/32 amps,single pole, \"B\" SERIES27952Each
2802802.12\nS/F 'C' series. S.P.MCB:-\nSupplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.280
2812812.12.1\n6/32 amps,single pole, \"C\" SERIES28141Each
2822822.12.6\n40 amps ,DP2821Each
2832832.16.9\n40 amps,TPN2834Each
2842842.12.10\n50/63 amps, TPN2844Each
2852852.13\nS/F SP MCB blanking plate:-\nSupplying and fixing Single pole blanking plate in exiting MCB DB complete etc as required.2854Each
2862862.19\nP/F M.V. danger notice plate:-\nProviding and fixing M.V danger notice plate of 200mm x150mm made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red coiour on front side as required.2861Each
2872873.9\nS/L 8 SWG copper wire ground :-\nSupplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.28720Metre
2882884.2\nP/F G.I. lightning conductor finial:-\nProviding and fixing of lighting cnductor finial, made of 25 mm dia 300mm long, copper tube having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required.2885Each
2892894.4\nReverting, sweating and soldering of copper/G.I. tape(with another coppr/G.I. tape, base of the finial or any other metallic object) as required.28915Each
2902904.7\nP/F G.I. lightning conductor tape in horizontal run:-\nProviding and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(For horizontal run)290135Metre
2912914.8\nP/F G.I lightning conductor tape in vertical run:-\nProviding and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(for vertical run)29149Metre
2922925.1\nMV cable laying upto 25 sq.mm. in ground:-\nLaying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 25 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.292135Metre
2932935.2\nMV cable laying upto 120 sq.mm. in ground:-\nLaying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 25 sq.mm.but not exceeding 120 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.293105Metre
2942948.5\nErection of steel pole upto 10 m in C.C.:- Erection of steel tubular pole of length exceeding 8 metres but not exceeding 10 metres in cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required.2944Each
295295\nS/L PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:1554, part-1)295
296296code no 1905\n16 sq.mm. 4 core296130Metre
297297code no 1908\n50 sq.mm. 3.5 core29720Metre
298298code no 1910\n95 sq.mm. 3.5 core298214.765Metre
299299DSR 12.37\nSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required2992Each
300300DSR9.1\nSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.300
301301DSR9.1.33\n4 X 16 sq. mm (28mm)3019Each
302302DSR9.1.22\n3½ X 50 sq. mm (35mm)3022Each
303303DSR9.1.24\n3½ X 95 sq. mm (45mm)3032Each
304304FIXTURE AND CHEMICAL EARTHING304
305305CODE No.2104\nProviding of 12'' (300 mm)exhaust fan of make bajaj/havells/usha/crompton30517Each
306306CODE No.2101\nProviding of 48'' (1200 mm) ceiling fan of make bajaj/havells/usha/crompton30635Each
307307CODE No.2105\nProviding of 16'' (400 mm) Wall fan of make bajaj/havells/usha/crompton30724Each
308308CODE No.2203\nProviding of Reces/surfaces mounted LED round down light (15/16 watt) of make bajaj/havells/jaquar/crompton30852Each
309309CODE No.2218\nProviding of LED street light (90/100 watt) of make bajaj/havells/jaquar/crompton3096Each
310310CODE No.2225\nProviding of LED Flood light (120 watt) of make bajaj/havells/jaquar/crompton3104Each
311311CODE No.2263\nProviding of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/jaquar/crompton3113Each
312312CODE No.2229\nSupply of LED batten (10/12 watt) of make bajaj/havells/jaquar/crompton3128Each
313313CODE No.2230\nSupply of LED batten (20/22 watt) of make bajaj/havells/jaquar/crompton31347Each
314314CODE No.2225\nSupplying and fixing of LED 15/16 W of make bajaj/havells/jaquar/crompton3146Each
315315Anaylised & Approved\nITC LED 25/ 90W street ligt on wall with 25 mm dia .75meter long GI pipe bend, J /U Hook 4 nos., along with two coat painting of GI pipe bend etc as required3152Each
316316Code no. 2301\nSupply /fitting/fixing of 50 mm dia chemical Earthing Electrode 3 mtr length ,Backfill compound chemical 4 bag (per bag 25 kg), Earth cutting removing and installation charge as. required. OF MAKE POWERGRIP EARTHING ELECTRODE. RANCHI/ELECTROGRIP RANCHI3169Set
317317Code no. 2001\nSupplying and fixing of 7 Mtr height octagomal Hot-Dip Galvanized pole (BOP-7030) with top dia 70 mm,bottom dia 130mm & made of 3 mm thick sheet ,base plate diamentions 200 MM X 200 MM X 12 MM (LxBxT) including suitable size of foundetion bolt and 1'6'' long 50mmX50mm MS angle along with welded horizontally on top of octagonal pole all complete on exiting concreat platform as required OF MAKE BAJAJ/SURYA/PHILIPS3174Each
318318Code no. 2017\nSupplying and fixing of 1.5 mtr single arm suitable for 70 mm top of existing Octagonal pole OF MAKE BAJAJ/SURYA/PHILIPS3184Each
319319Anaylised & Approved\nSupplying fitting fixing testing and commisioning of Water pump controlar for single phase submerssible motor with sensor as required of make AQUATECH/MAXTAN TECHNOLGIES/RMG AUTO PUMP CONTROLAR3191SET
3203201.16\nTeliphone wiring existing conduit:- Supplying and drawing following pair 0.5 sq mmFR PVC insuleted copper conductor, unaramed teliphone cable in existing recessed PVC conduit as required (FOR WATER PUMP CONTROLAR WIRING)320
3213211.16.3\n3 Pair32190Metre
3223221.21\nS/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required . (FOR WATER PUMP GONTROLAR WIRING)322
3233231.21.1\n20mm32385Metre
324324Analaysed & Approved\nMain Panel : Supplying fixing testing commissioning of 16 swg crca sheey steel panel box including painting, copper wiring, CT,PT,digital ampmeter,volt meter,copper basbar(40mmx6mm) 3 set, MCCB 4 pole 35 KA 1No,MCB 4 POLE 63 AMP 4 Nos,MCCB 4POLE 40 AMP 5 Nos, DP 40 AMP3 NOs,SP 16 AMP 2 NOs,contactor 4 pole 80 amp 1no, contractorh 4 pole 63 amp 1no,slector switch 2nos,surge protectin device 1 nos, push botton 2 nos, RYB INDICATOR 3 NOs, etc as required3241Set
325325CCTV325
3263261.27\nSupplying and fixing following size /modules G.I. box along with modular base and cover plate for modular switches in recess etc. as required326
3273271.27.1\n1 or 2 modules (78mmx78mmx45mm)3278Each
328328Analaysed & Approved\nProviding, drawing, fitting, fixing, connecting and testing of indoor/ outdoor 1/3\" SONY Effo E, 650 TVL OLUX ,External Adujustable IR Camera,28-12mm built-in iris lens,with 36 pcsIR LED. IR 40m, IP-66 including connections along with all standard accessories, i,e complete in all respect. Make-BOSCH. EVER FOCUS / TOSHIBA / PERITO / PANSONIC3288Each
329329Featues329
3303301. 1/3\" Color SONY Super Had II Day & Night CCD Sensor.330
3313312. Razor Sharp High Resolution: 650 TV Lines (Color)331
3323323. 35 IR LED's enable vieing in total darkness up to 75 FT.332
3333334. 0 Lux at IR on.333
3343345. 2.8-12 EXTERNBAL adjustable Vari-focal lens.334
3353356. 2DDNR (2D Digital Noise Reduction)335
3363367. Weatherproof.336
3373378. Compact & Light Weight .337
3383389. Vandal-resistant: Polycarbonate Cover & Metal Body.338
33933910. DC 12V339
340340Analaysed & Approved\nProviding, fitting, fixing, connecting and testing of 8 Ch. Video and audio in put, 8 SATA interfaces, 4CIF/2CIF, 6 fps/Ch,alarm,I/O 16/4 along with all standard accessories complete in all respect with required size of wall mount rack. Make- BOSCH/EVER FOCUS/ Hik- VISION/ PERITO.3401Each
341341Key features :-341
342342DS-8104/8108/8116HDI-ST Standalone DVR.342
343343H.264 video compression.343
344344HDMI and VGA output at up to 1920 x 1080 P resolution.344
345345Dual Stream345
3463464/8/16 CH Sychronous playback.346
347347HDD quota and group management347
348348Rear panel of DS 8116 HDI-ST Video in Audio in Video spot out Video out Audio out Line in RS 232 serial interface VGA interface HDMI interface eSATA interface LAN interface Terminal switch RS-485 serial interface, keyboard interface, alarm in, alarm out GND 100-240 VAC power input Power switch348
349349Analaysed & Approved\nSupply, fitting, fixing, commissioning and testing 32\" LED colour Full HD TV totally flat full HD, resolution-1920 x 1080 with 2 x HDMI, 1 x USB, remote control & battery for remote control along with all accessories & 1 year warranty. for Live View and Replay of Recorded View HD TV Make:- Make:- Sony Model: KLV-32R482B / Samsung Model: 32J5300 / LG Model: 32LF560T.3491Each
350350Analaysed & Approved\nProviding, fitting, fixing, connecting and tesing of 4 Port video switcher, cable, along with all standard accessories complete in all respect. Make-Good Local Brand.3501Each
351351Analaysed & Approved\nProviding of NAS storage 2TB internal HDD along with all standard accessories complete in all respect. Make- DLINK/SEAGATE/WESTERN-DIGITAL.3511Each
352352Analaysed & Approved\nProviding, fitting, fixing, connecting and testing of 12 V DC 10 Amp. Charger along with all standard accessories complete in all respect. Make- Good Local Brand.3521Each
3533531.21\nS/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required .353
3543541.21.2\n25mm354175Metre
355355Analaysed & Approved\nWiring and commisioningof 3+1 video cable and Power copper cable for entire CCTV in existing 2mm thick 25mm PVC Pipe surface/ recess with all accessosories as required..355180Metre
356356Rain Water Harvesting356
3573575.1.1\nEarth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.35729.538Cum.
3583585.1.2\nExtra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)35829.538Cum.
3593595.1.10\nProviding coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)3597.512Cum.
3603605.6.1\nProviding designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I36011.333Sqm
3613615.3.2\nProviding P.C.C.M 150 in normal mix of (1:2:4) in foundation with approved quality of stone chips 20 mm 6 mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I3610.85Cum.
3623625.2.3\nProviding designation 75A brick work in CM (1:6) in Foundation and plinth with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.36214.1Cum.
363363SOR Page 20 of Itm no 9 & 10% CP\n Stone Metal at quarry site .. Traxes and royalty all complete as per building specification and direction of E/I.\n0.90 m Gravel filling363
3643640.90 M stone Boulder filling3645.152Cum.
3653655.3.30.1\nProviding precast R.C.C.M -200 with nominal mix.of (1:1.5:3) slab of desired size with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including curing, shuttering, carrying the slab manually to site and laying in position, (but excluding the cosat of reinforcement) taxes and royalty all complete as per building specification and direction of E/I3650.753Cum
3663665.7.1\nProviding 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.3666.21Sqm
3673675.7.6 \n Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I.3676.21Sqm
3683685.5.4\nProviding Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)3680.113M.T.
369369DSR 12.41.2\nProviding and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.\n110 mm diameter36931.8M
370370DSR 12.42 \nProviding and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :\n5382, leaving 10 mm gap for thermal expansion.370
371371( 12.42.5.2) 110 mm bend3718Each
372372( 12.42.6.2) Shoe 110 mm3722Each
373373DSR 12.43.2\nProviding and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand)\nand making good the wall etc. complete\n(110 mm )37312M
374374Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.374
375375Bricks (1K+ 45 P = 46 KM.)3756.09%0 Nos.
376376Local Sand (3 KM.)3767.512Cum.
377377Coarse Sand (1k+11P=12 KM.)3775.8Cum.
378378Chips (45) km3781.412Cum.
379379Cement (45KM.)3791.838MT
380380Steel ( 45 KM.)3800.113MT
381381SOR PHED (page no 31 sl no 117) DT: \nBasic rate for 115/125 mm dia drilled Tube Well for drilling in all kinda of Soil and rock for installation o hand pump with DI rings all complete including supplyin all materials, labours , tools drilling rigs air compressor and equipments s well as fuel li\ubricant for making 115/125 mm dia boring etc and cost of transporting rig machine and other vechile up to site of work including contrctor profit & OH chares as per specification and directtion of Engineer Incharge fo the year 2015-16.381
382382Drilling upto 30 M depth below G.L in Rular area38230P/M
383383Drilling beyond 31 mtr upto 55 mtr below GL in Rural area38330P/M
384384SOR PHED (page no 17 sl no 105) \nBasic rate of 32 mm UPVC pipe 125 mm dia conforming o IS: latest version:\n38430P/M
385385S/M/L for F/f wire mesh pipe3851Each
386386Drain (50 M)386
3873875.1.1\nEarthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I.38727Cum
3883885.1.2\nExtra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)38827Cum.
3893895.1.10\nProviding coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)3893.375Cum.
3903905.6.1\nProviding designation 75 A one brick flat soling joints filles with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I39045Sqm
3913915.3.2\nProviding PCC M-150 with nominal mix of (1:2:4) in filling in plinth & sunken slab of toilet with approved quality of stone metal grade III (53 to 22.4mm size) and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixture, placing in position, vibration, striking, curing taxes and royalty all complete as per building specification & direction of E/I.3915.25Cum
3923925.2.3\nProviding designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.3929.375Cum.
3933935.3.30.1\nProviding precast R.C.C.M -200 with nominal mix.of (1:1.5:3) slab of desired size with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including curing, shuttering, carrying the slab manually to site and laying in position, (but excluding the cosat of reinforcement) taxes and royalty all complete as per building specification and direction of E/I3931.6Cum
3943945.7.3\nProviding 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I39485Sqm
3953955.7.11\nProviding 1.5 mm thick cement punning including curing, carriage of water with all leads and lifts of water as per building specification and direction of E/I.39585Sqm
3963965.5\nProviding TMT reinforcement of following dia rods as per approved design and drawing including carriage of M.S. rods of (Straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.396
3973975.5.4\n8 mm dia - TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)3970.1625MT
398398Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.398
399399Bricks (1K+ 45 P = 46 KM.)3994.7625%Nos.
400400Local Sand (3 KM.)4003.375Cum
401401Coarse Sand (1k+11P=12 KM.)4017.6Cum
402402Chips (45) km4026.05Cum
403403Cement (45KM.)4038.45MT
404404Steel ( 45 KM.)4040.1625MT
405405Land Development ( with toe wall)405
4064065.1.1\nEarth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.40625.2Cum.
4074075.1.2\nExtra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)40725.2Cum
4084085.1.8\nFilling in foundation trenches and plinth layers not exceeding 150 mm thick well watered rammed fully compacted and fine dressed with earth obtained after cutting with in a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I ( Mode of measurement compacted volume)408275Cum.
4094095.1.10\nProviding coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)4092.25Cum.
4104105.2.3\nProviding designation 75A brick work in CM (1:6) in Foundation and plinth with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.41033.75Cum.
4114115.6.1\nProviding designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I41130Sqm
4124125.3.2\nProviding P.C.C.M 150 in normal mix of (1:2:4) in foundation with approved quality of stone chips 20 mm 6 mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I4122.25Cum.
4134135.7.1\nProviding 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.413123Sqm
4144145.7.11\nProviding 1.5 mm thick cement punning including curing, carriage of water with all leads and lifts of water as per building specification and direction of E/I.414123Sqm
415415Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.415
416416Bricks (1K+ 45 P = 46 KM.)41614.67%0 Nos.
417417Local Sand (3 KM.)4170.458Cum.
418418Coarse Sand (1k+11P=12 KM.)41816.51Cum.
419419Chips (45) km4192.025Cum.
420420Cement (45KM.)4204.913MT
421421Add 1% Lebour Cess4211Nos
422422Add 12% GST4221Nos

AI Tender Summary

OUR REF NO 21830263
AUTHORITY Government Departments
TENDER VALUE 2.14 Crore
LAST DATE 30-09-2019
Authority
Authority Name Jharkhand Police Housing Corporation Limited
Work Description Construction Of Fortified Police Station At Gudri In The District Of West Singhbhum .
Basic Detail
Tender No JPHCL/GR 14/NIT 09/2019-20
Bidding Type Tender
Location
City Gudri
State Jharkhand
Key Dates
Publish Date 18 Sep 2019
Submission Date 30 Sep 2019
Open Date 03 Oct 2019
Finance
Tender Value 2.14 Crore
Tender Fee 10000
EMD 4.29 Lakhs
Exemption Not Available
Document List
BA828AEA-56EE-46F9-AAB5-09F88DA5999E.html
Tendernotice_1.pdf
TechnicalBidDocument1.pdf
BOQ_54986.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 18, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 30, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 03, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

BA828AEA-56EE-46F9-AAB5-09F88DA5999E.html

pdf

Tendernotice_1.pdf

pdf

TechnicalBidDocument1.pdf

xls

BOQ_54986.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders