Repair Of Leakages / Bursts , Detection Of Intersecting Polution Point , Removal Of Choking’S And Interconnection In Ac/Pvc/ Ci Pipe Line In Under Sub Dn Degana
Tender Value
6 Lakhs
Estimated cost
Bid Submission
09 Oct 2019
0 days left
EMD
3000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
merta city → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair Of Leakages / Bursts , Detection Of Intersecting Polution Point , Removal Of Choking’S And Interconnection In Ac / Pvc / Ci Pipe Line In Under Sub Dn Degana
BOQ
| Name of Work: REPAIR OF LEAKAGES / BURSTS , DETECTION OF INTERSECTING POLUTION POINT , REMOVAL OF CHOKING’S AND INTERCONNECTION IN AC/PVC/ CI PIPE LINE IN UNDER sub dn Degana | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Labour charges for leakage removal at existing pipeline laid in trenches by replacing damaged pipe by inserting new pipe piece of required length upto 1.20 mtr length and jointing it with existing pipeline by CI detachable joints. The work shall include excavation, backfilling, dewatering, dismentalling of AC coupling/CID joints/ MS clamp from existing pipeline, pipe cutting and end penetrations required at existing pipeline and for preparation of new pipe pieceetc, complete including testing of the work done for water tightness and taking care of all underground utilities like telephone ,electric cables, water, sewer lines etc. | |||
| 2 | 1.01 | 80 mm Dia. AC Cl-10/15 Pipeline | 1 | EACH | |
| 3 | 1.02 | 100 mm Dia. AC Cl-10/15 Pipeline | 1 | EACH | |
| 4 | 1.03 | 125 mm Dia. AC Cl-10/15 Pipeline | 1 | EACH | |
| 5 | 1.04 | 150 mm Dia. AC Cl-10/15 Pipeline | 1 | EACH | |
| 6 | 2 | Labour charges for leakage removal at existing pipeline laid in trenches by replacing damaged pipe by inserting new pipe piece of required length upto 1.20 mtr length and jointing it with existing pipeline by CI detachable joints. The work shall include excavation, backfilling, dewatering, dismentalling of PVC Socket /CID joints/ MS clamp from existing pipeline, pipe cutting and end penetrations required at existing pipeline and for preparation of new pipe pieceetc, complete including testing of the work done for water tightness and taking care of all underground utilities like telephone ,electric cables, water, sewer lines etc. | |||
| 7 | 2.01 | 63 mm Dia. UPVC Pipeline | 1 | EACH | |
| 8 | 2.02 | 75 mm Dia. UPVC Pipeline | 1 | EACH | |
| 9 | 2.03 | 90 mm Dia. UPVC Pipeline | 1 | EACH | |
| 10 | 2.04 | 110 mm Dia. UPVC Pipeline | 1 | EACH | |
| 11 | 3 | Labour charges for leakage removal at existing pipeline laid in trenches by replacing damaged pipe by inserting new pipe piece of required length upto 1.20 mtr length and jointing it with existing pipeline by CI detachable joints. The work shall include excavation, backfilling, dewatering, dismentalling of Socket /CID joints/ MS clamp from existing pipeline, pipe cutting and end penetrations required at existing pipeline and for preparation of new pipe pieceetc, complete including testing of the work done for water tightness and taking care of all underground utilities like telephone ,electric cables, water, sewer lines etc. | |||
| 12 | 3.01 | 80 mm Dia. C.I./D.I Pipeline | 1 | EACH | |
| 13 | 3.02 | 150 mm Dia. C.I./D.I Pipeline | 1 | EACH | |
| 14 | 4 | Labour charges for leakage removal at existing pipeline laid in trenches by using MS clamp and wooden dat, Lead wool of AC/UPVC/CI/DI/GI Pipe line with care by excavating trenches in all types of soil/rocks including road cutting to required length and depth if leakage found in old disconnected end or leakage in service connection and hole in pipeline then fixing MS leakage calmp after removing old connection clamp and G.I. fitting as persite condition or inserting lead wool in AC coupling/CI joints as the case found. The work shall include excavation, backfilling, dewatering, dismentalling of MS clamp from existing pipeline as required etc, complete including testing of the work done for water tightness and taking care of all underground utilities like telephone ,electric cables, water, sewer lines etc. | |||
| 15 | 4.01 | For Pipeline Size 50 mm to 150 mm | 1 | EACH | |
| 16 | 5 | Earth work in excavation by mechanical means (Hydraulic Exacavtor)/ Manual means over areas (exceeding 30 cm in depth 1.5 mtr in width as well as 10 Sqm on Plan) including disposal of excavated earth , lead upto 50 mtr and lift upto 1.5 mtr, disposed earth to be levelled and neatly dressed | |||
| 17 | 5.01 | All kinds of soil | 1 | CUM | |
| 18 | 6 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. | |||
| 19 | 6.01 | 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). | 1 | CUM | |
| 20 | 6.02 | M15 grade Nominal Mix 1:2:4 (1 cement : 2 coarse sand : graded stone aggregate 20 mm nominal size). | 1 | CUM | |
| 21 | 7 | Dismantling manually or by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 mtr lead as per direction of EIC | |||
| 22 | 7.01 | WBM (Avg thickness 250 mm) | 1 | SQM |
AI Tender Summary
Tender Timeline
Sep 16, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedOct 09, 2019
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 10, 2019
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender