Special Repair To Building No Tr-31 ( Single Jcos Living Accn ) , Tr-53 ( Sig Store ) And Tr-07 ( Single Or Living Accn ) Including Roof Treatment With Truss And Ac Sheet , False Ceiling , Plastering , Joinery , Flooring , Tiling And Rewirin, GE (South) Mamun-Punjab

Military Engineer Services-MES has published Special Repair To Building No Tr-31 ( Single Jcos Living Accn ) , Tr-53 ( Sig Store ) And Tr-07 ( Single Or Living Accn ) Including Roof Treatment With Truss And Ac Sheet , False Ceiling , Plastering , Joinery , Flooring , Tiling And Rewirin. Submission Date for this Tender is 09-10-2019. Roofing Materials Tenders in GE (South) Mamun Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

21791680
Special Repair To Building No Tr-31 ( Single Jcos Living Accn ) , Tr-53 ( Sig Store ) And Tr-07 ( Single Or Living Accn ) Including Roof Treatment With Truss And Ac Sheet , False Ceiling , Plastering , Joinery , Flooring , Tiling And Rewirin
Open Tender
Indian
Punjab
GE (South) Mamun
09-10-2019

Tender Details

Special Repair To Building No Tr-31 ( Single Jcos Living Accn ) , Tr-53 ( Sig Store ) And Tr-07 ( Single Or Living Accn ) Including Roof Treatment With Truss And Ac Sheet , False Ceiling , Plastering , Joinery , Flooring , Tiling And Rewiring Under Ge ( South )

Key Value

Document Fees
INR 500 /-
EMD
INR 68000.0 /-
Tender Value
INR 34 Lakhs /-

BOQ Items

Name of Work : SPECIAL REPAIR TO BUILDING NO TR-31 (SINGLE JCOS LIVING ACCN), TR-53 (SIG STORE) & TR-07 (SINGLE OR LIVING ACCN) INCLUDING ROOF TREATMENT WITH TRUSS AND AC SHEET, FALSE CEILING, PLASTERING, JOINERY, FLOORING, TILING AND REWIRING UNDER GE (SOUTH) MAMUN AT MAMUN MIL STN
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down chowkhats or frames of any description not exc 1.50 Sqm each with shutters, (without taking off shutters from the frame) including builders hardware , complete all as specified and directed. 22 Each
2 2 Taking down chowkhats or frames of any description exc. 1.50 Sqm and n.exc 4.00 Sqm each with shutters, (without taking off shutters from the frame) including builders hardware complete all as specified and directed. 26 Each
3 3 M&L for pressed steel frames 125mmx60mm for door, made out of 1.25 mm thick MS sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plate and back filling for chowkats in PCC (1:3:6) type C-0 (using 12.5mm graded crushed stone aggregate) tarring ends incl 02 coats of synthetic enamel paint over a coat of red oxide primer on exposed surface complete all as specified and directed. 40.8 RM
4 4 M&L for pressed steel frames 105mmx60mm for door, made out of 1.25 mm thick MS sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plate and back filling for chowkats in PCC (1:3:6) type C-0 (using 12.5mm graded crushed stone aggregate) tarring ends incl 02 coats of synthetic enamel paint over a coat of red oxide primer on exposed surface complete all as specified and directed. 22 RM
5 5 M & L for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.\n 10 RM
6 6 M&L for 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12mm veneered particle board with commercial veneering on both faceS ,The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated, fitted to chowkhats incl 02 coats of synthetic enamel paint over a coat of pink primer after preparation of surfaces complete all as specified and directed. 22 Sqm
7 7 M&L for 35mm thick glazed and skeleton shutters (Factory made) of 2nd class hard wood and prepared to receive glass or gauge etc with rounded, chamfered or mitred sash bars edges of framing plain chamfered or rounded fitted with cut and mitred beads and fitted to chowkats for securing glass/gauge, size of stiles rails and other parts as per clause 8.20 (a) of SSR Part-I 2009 (Larger size to be provided) incl 02 coats of synthetic enamel paint over a coat of pink primer after preparation of surfaces complete all as specified and directed. 14 Sqm
8 8 M&L factory made solid panel wood grain printed PVC sheet door shutter using 5 mm thick x 15 mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900) used instead of exposed portion of PVC sheet beading, 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.\n 3.2 Sqm
9 9 M&L for Box type Steel windows and ventilators comprised of tubular frame and shutters made out of 1.25mm thick M S sheet tube factory made with double side hung wire gauged shutter & glass/glazed shutter (wire cloth and glass panes only shall be measured and paid separately) with steel handle and steel peg stay dovetailed or welded incl 2 Nos. tower bolts 150mm long for each leaf and 10mm square bar grills at spacing as shown on drg, welded to F I frame work, including other fittings; hinges, handles, tarred hold fasts fixed in PCC blocks all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 36 Sqm
10 10 M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty or fixed with beads/ glazing pins not .exc 0.5sqm in each pane complete all as specified and directed. 21 Sqm
11 11 M&L for Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks or galvanized wire staple complete all as specified and directed. 32 Sqm
12 12 M&L for 3mm thick figured glass, pin head type and glazing with oil putty or fixed with beads/ glazing pins not .exc 0.5sqm in each pane complete all as specified and directed. 1 Sqm
13 13 M&L for Aluminium anodised barrel tower bolt, extruded section 150mm long , complete all as specified and directed. 44 Each
14 14 M&L for Aluminium anodised handle, extruded section of size 150mm complete all as specified and directed. 44 Each
15 15 S&F Door closer hydraulically regulated, designation No. 3, universal type, complete all as specified and directed. 8 Each
16 16 M&L for 300 mm aluminium alloy sliding door bolt with hasp & staple (bolt type) and fixing clip of sheets cast or extruded section and fixing sliding bolt of extruded section complete all as specified and directed. 12 Each
17 17 M&L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection laid in slope finished even and fair including making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio (1:2) by weight including dismantling existing floor of any type and pattern and removal of rubbish out off the premises complete all as specified and directed. 98 Sqm
18 18 Dismantling timber scantlings 40 sq cm & over in section, in unframed work etc complete all as specified and directed. 5 Cum
19 19 M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 including welding of distance pieces cleats and application of 02 coats of synthetic enamel paint over a coat of red oxide primer after preparation of surfaces including dismantling of existing truss of any description complete all as specified and directed. 3210 KG
20 20 S&F tubular purlins fixed independently made out of medium grade tube (ERW or induction butt welded upto 40 mm bore confirming to I. S.1161-1979 grade St.-240 including welding of distance pieces, jointing plates and application of 02 coats of synthetic enamel paint over a coat of red oxide primer after preparation of surfaces including dismantling of existing truss of any description complete all as specified and directed. 2740 KG
21 21 S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm long and n exc 30cm long, 16mm dia of Shank, complete all as specified and directed. 46 Kg
22 22 M&L for Cement concrete (1:1.5:3) type A-1 (using 20mm graded crushed stone aggregates) such as in column for fixing of truss, benching, coping, Bed blocks and the like, rounded or chamfered on edges including necessary formwork including demolition of existing concrete of any description and removal of debris out off the premises complete all as specified and directed. 2 Cum
23 23 M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws incl dismantling of existing sheets of any type complete all as speecified and directed. \n[Note : The colour sheet shall be as approved by GE ] 460 Sqm
24 24 M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick having tensile strength of 550 Mpa as in ridge fixed with self tapping screws incl dismantling of existing sheets of any type complete all as speecified and directed.\n[Note : The colour sheet shall be as approved by GE ] 18 Sqm
25 25 M&L for False ceiling of 9.5mm thick gypsum tiles (600x600mm) laminated with PVC film on the face side & metalised polyester film on the back side with all four edges sealed with PVC film (shade either plain white or crack) in a grid size of 605x605mm from manufacturer M/s Saint Gobain or equivalent of Armstong/Everest including taking down existing ceiling board of any type/pattern with GI frame work with grid size of 605 x 605 mm for seamless ceiling comprising of GI perimeter channel 0.5 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI Hangers 2 mm dia (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm sixe 60mm long and expansion hold fasteners 12.5mm ida, 40mm long incl taking down existing grid complete all as specified. complete all as specified and directed.\nNote :- Invoice from company’s authorized dealer shall be submitted with material by the contractor along with dealership certificate. Certificate of genuineness from the manufacturer shall also be submitted by the contractor before getting the material passed from the department. 380 Sqm
26 26 M&L for Non-skid ceramic coloured rectified edges joint free tiles 8mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:4) including dismantling of existing floor, hearth or wall tiling complete all as specified and directed. 12 Sqm
27 27 M&L for Non-skid ceramic coloured rectified edges joint free tiles 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in floors etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:4) including dismantling of existing floor, hearth or wall tiling complete all as specified and directed. 210 Sqm
28 28 M&L for Industrial grade matt finish type-V, thickness 20 mm floor tile of size area exc 0.11Sqm but n.exc 0.18Sqm, set and jointed in neat cement slurry and pointed in coloured epoxy grout to match over and including 15mm thick screed bed in CM 1:4 (surface finished even and rough to receive tile) including roughening surfaces of existing concrete floor by picking, sweeping clean & washing down with water to remove dust and apply neat cement slurry @ 3.00kg of cement per sqm complete all as specified and directed. 84 Sqm
29 29 M&L for Industrial grade matt finish type-V, thickness 20mm tile of size area exc 0.11Sqm but n.exc 0.18Sqm in skirting/dado, set and jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 10mm thick backing coat in cement mortar 1:3 (surface finished even and rough to receivetile) including dismantling existing plastering/ existing tiles and removal of debris out off premises complete all as specified and directed. 6 Sqm
30 30 M&L for Glazed ceramic (coloured) tiles 7mm thick, of size 450mmx300mm on vertical surfaces such as dado etc, set and jointed in neat cement slurry and pointed in coloured epoxy grout to match tiles over and including 10mm thick backing coat in cement mortar (1:4), surface finished even and rough to receive tiles, including dismantling existing tiles of any type and pattern including cement mortar backing coat and removal of rubbish out off the premises complete all as specified and directed. 250 Sqm
31 31 S&F in repair 15mm bore Stop valves fancy type, chromium plated cast copper alloy long shank and exposed part kit with fitting sleeve, operarting lever & adjustable wall flange (concealed type) screwed both ends for iron pipe or for unions complete all as specified and directed. \nMake : Jaquar Cat part No CON-083FT & CON-083FTK or equivalent of Hindware/Marc. 2 Each
32 32 S&F 400mm x500mm cabinet mirror of selected quality 5mm thick glass with PVC storage cabinet fixed with chromium plated brass screws and cup washers to wall complete all as specified and directed. 2 Each
33 33 S&F in repair for single towel rail brass chromium plated 600mm long fixed with chromium plated screw and PVC cleat complete all as specified and directed.\nMake : Cat part No AQN-7711 of Jaquar or equivalent model in Hindware/Marc. 2 Each
34 34 S&F in repair Brass Chromium Plated shower rose with arms fancy type with swivel joints 75 mm face dia of appoved make and cat part for 15mm bore iron pipes complete all as specified and directed.\nMake : Prayag Cat part No BS-73 or equivalent model in Hindware/Marc. 2 Each
35 35 S&F 15 mm bore Stop valves/Angle valve cast copper alloy, chromium plated (ISI marked) , screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed. \n 10 Each
36 36 S&F in repair for 15mm bore bib taps fancy type with wall flange, chromium plated cast copper alloy long body with capstan heads, screwed for iron pipe or brass ferrule complete all as specified and directed.\n 10 Each
37 37 S&F 15 mm bore Stop valves/Angle valve cast copper alloy, chromium plated (ISI marked) , screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. \n 8 Each
38 38 S&F in repair for Rotational moulded polyethylene water storage tanks three layer of capacity 1000 litre, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm ball valve high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball and dismantling of existing PVC tank of any capacity, complete all as specified & directed. 1 Each
39 39 S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. Make:Paryag/Polytech 6 Each
40 40 M&L for GI water tubing surface/concealed, 15mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor, including taking down existing unserviceable GI tubing and connections complete all as specified and directed.\n(Note : Cutting chases and making good shall be measured and paid separately) 14 RM
41 41 M&L for GI water tubing surface/concealed, 20mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor, including taking down existing unserviceable GI tubing and connections complete all as specified and directed.\n(Note : Cutting chases and making good shall be measured and paid separately) 8 RM
42 42 Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not\nexc 10 cm girth complete all as specified & directed. 14 RM
43 43 S&F 20 mm bore mild steel drapery rod with 1mm thick PVC wood grain coating including brackets and knobs fixing on window and doors for hanging curtains \n 68 RM
44 44 M&L for Brick work with Fly Ash Brick (Non-Modular) Class 7.5, straight or curved on plan exceeding 6m mean radius built in CM (1:6) incl dismantling of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc and removal of rubbish out off the premises complete all as specified and directed. 32 Cum
45 45 M&L for 60mm thick factory made rubberised coloured (laminated) interlocking paver block (using vibro compaction method) (topping thickness not less than 5mm) in white cement and non fadable glossy pigment of approved shade of any shape and size conforming to IS-15658-2006 of M-35 grade laid over & including cleaned dry sand cushion 50mm thick over and including 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) including demolition of damaged cement concrete of any type or description and removal of debris out off the premises etc complete all as specified and directed. 466 Sqm
46 46 M&L for Rendering 15mm thick in two layers (base layer 10mm & finishing layer 5mm thick) in cement mortar (1:4) using liquid water proofing compound on brick work or concrete surfaces of wall, surfaces finished even and smooth using extra cement including taking down cement or cement lime plaster of any description and raking out joints, hacking for key, scrubbing down with water and removal of rubbish, out off the premises, etc complete all as specified & directed.\n(Note : WPC shall be measured and paid separately) 560 Sqm
47 47 M&L for rendering 10mm thick on brick work or concrete surface in CM (1:6) on wall surfaces finished even and smooth using extra cement including taking down cement or cement lime plaster of any description and raking out joints, hacking for key, scrubbing down with water and removal of rubbish, out off the premises complete all as specified & directed. 476 Sqm
48 48 M&L for preparation of newly plastered surfaces of wall & applying two coats of distemper oil emulsion (OBD) over a coat of primer as per manufacturer instructions (from same manufacturer of OBD) over a layer of wall care putty 3mm thick complete all as specified and directed. 476 Sqm
49 49 M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint over a coat of primer as per manufacturer instructions complete all as specified and directed. 560 Sqm
50 50 M&L for 20 mm bore gun metal gate valve, with cast iron wheel head, screwed both ends for GI pipe, fixed in repair, etc complete all as specified and directed. 1 Each
51 51 S&F in repair for Vitreous china white wash down water closet pan (pedestal pattern) with normal closing seat cover S-trap (Make : Jaquar Cat part No CNS-WHT-553SN or equivalent Cat Part/Model of Hindware/Parryware/ Somany) & hand shower (Health foucet) 8mm dia 1.5m long flex tube in chrome finish and wall hook with NRV (Back flow preventer) and connection to drain (or out going pipe) (Make : Jaquar Cat Part No ALD-577 or equivalent Cat Part/Model of Hindware/Parryware) and to flush pipe, antisyphonic pipe etc complete all as specified and directed 2 Each
52 52 S&F in repair PVC flushing cistern dual flush type 10 Ltr capacity, valve-less syphonic action type, low level, complete with inlet, ball valve, handle, including brackets/pins, PVC flush pipe 32mm bore and PVC connection 15mm bore 450mm long complete all as specified and directed. 2 Each
53 53 M&L for Vitreous china wash hand basin, white, flat back, size 550x400mm (Make : Jaquar Cat part No CNS-WHT-801 or equivalent model in Hindware/Parryware/Somany) including 15mm bore fancy type Pillar taps, cast copper alloy, with long screwed shank and fly nuts, chromium plated (Make : Jainko Cat part No PCJ-1 or equivalent model in Hindware/Marc.) brackets, CP waste coupling, 32mm bore PVC waste pipe of min 600mm long & 15 mm bore PVC connections, including cutting for and pinning in end of brackets or erecting stand fixed in repairs complete all as specified and directed. 2 Each
54 54 S&F LDEP waste pipe, 32mm dia suitable for WHBs/ Sinks, including threaded PVC socket suitable for shank of waste coupling complete all as specified & directed. 3 RM
55 55 S&F stainless grating doom 100mm dia with waste hole fixing in floor complete all as specified & directed. 2 Each
56 56 S&F stainless grating doom 100mm dia fixing in floor complete all as specified & directed. 2 Each
57 57 Form work to sides of soffits and floors or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhanges etc also splays between floors and beams for fair finished concrete surface of concrete complete all as specified and directed. 58 Sqm
58 58 M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 360 Kg
59 59 M&L for Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 270 Kg
60 60 M&L for RCC 1:1.5:3 type A-1 Nominal Mix using 20mm graded crushed stone aggregate as in as in slabs / chajjas supported on walls, beams and columns, in floors, roofs, landings, balconies, canopies, deck slabs, and in shelves and the like including demolition of existing RCC of any type and removal of rubbish out off the premises complete all as specified and directed. 6.5 Cum
61 61 Taking down carefully unserviciable/ damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc ) and removing material from site and making good to the disturbed surface to match with existing finish complete all as specified and directed. 129 Per \npoint
62 62 M&L for Modular Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box and approved make sunken modular metal flush gang box and suitable support frame and cover plate (inner/outer) of required modules for mounting modular switches/ sockets etc, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point complete all as specified and directed.\n(Note : Modular switch/bell push/fan regulator etc shall be measured and paid separately under respective items.) 81 Per Point
63 63 All as per Srl item No. 62 above but two point controlled by two Nos switch 06 Amp one way, complete all as specified and directed. 2 Per \npoint
64 64 All as per Srl item No. 62 above but for 5 pin 5 Amp socket outlet point on independent gang box and suitable support frame and cover plate (inner/outer) controlled by one switch 5Amp one way, etc complete all as specified and directed. 16 Per \npoint
65 65 All as per Srl item No. 62 above but for 5 Pin 5 Amp socket outlet point on same board controlled by one switch 5 Amps one way on same gang box support frame and cover plate etc complete all as specified and directed. 16 Per \npoint
66 66 All as per Srl item No. 62 above but for one 15Amp socket outlet point concealed using 2.5Sqmm FRLS PVC insulated multi-strand copper conductor wire including 1.5Sqmm FRLS PVC insulated unsheathed copper conductor earth wire and making good to disturbed surfaces of wall floor to match existing finishes complete all as specified and directed. 16 Per \npoint
67 67 S&F Modular Socket outlet, 5 pin, multi purpose 2 module 6 Amps, AC 230 volts, etc complete all as specified and directed. \nMake : Crabtree (Verona) Cat Part No : ACVKSWW065 /Legrand Cat Part No 673452/ Schenider Cat Part No P2005. 32 Each
68 68 S&F Modular Socket outlet, 5 pin, multi purpose, 2 module 6/16 Amp, AC 230 volts, etc complete all as specified and directed.\nMake : Crabtree (Verona) Cat Part No : ACVKCWW163 Legrand Cat Part No 673455 / Schenider Cat Part No P2106. 16 Each
69 69 S&F Modular Switch 2 way 6/10 Amps , 1 module etc complete all as specified and directed.\nMake : Crabtree (Verona) Cat Part No : ACVSXXW101 or equivalent of Legrand/Siemens/Schenider. 4 Each
70 70 S&F Modular bell push, 10 Amp, AC 230 Volt etc complete all as specified and directed.\nMake : Legrand Cat Part No 673404/ Anchor Roma Cat Par No 289101/ Schenider Cat Part No P1005. 8 Each
71 71 S&F Modular Switch 1 way 16 Amps , 1 module etc complete , all as specified and directed.\nMake : Crabtree (Verona) Cat Part No : ACVSXXW161 /Legrand Cat Part No 673411/ Schenider Cat Part No P1101. 16 Each
72 72 S&F Modular Switch 1 way 6/10 Amps , 1 module etc complete all as specified and directed.\nMake : Crabtree (Verona) Cat Part No : ACVSXXW101, Legrand Cat Part No 673401, Anchor Roma Cat Par No 289101, Schenider Cat Part No P1001. 105 Each
73 73 S&F Ceiling rose polycarbonate isolated body surface Bakelite, not less than 65 x 50 mm, three terminals, AC 230 volts etc, complete all as specified and directed. \nMake : Havells Cat Part No Reo/Cona Cat Part No 9246/GM Cat Part No 8224\n 34 Each
74 74 S & F Fan regulator modular step type suitable for 1200/1400mm sweep ceiling fan hum free, 120W- 2 module including necessary connections complete all as specified and directed. \nMake : Legrand Cat Part No 673028/Crabtree Cat Part No ACARFHW005/Anchor Roma Cat Part No 66502.\n 16 Each
75 75 S&F Lamp holder insulated body with back plate suitable for batten fitting including 7W LED lamp of approved make and cat part and PVC Round/Square block etc complete all as specifeid and directed.\nMake : Anchor (Penta) Cat Part No : 51170 or equivalent of Havells(Reo)/SSK (Topline)/GM (Vyoma) for Lamp holder & \nMake : Wipro/Philips/Crompton/Havells for LED lamp 17 Each
76 76 S&F for Bell Ding Dong AC 230 Volt, single Pole complete all as specified and directed.\nMake : Anchor Cat Part No 8024/Cona Cat Part No 2856/ Anchor Cat Part No 8272/GM Cat Part No 4001. 8 Each
77 77 S&F Surface mounted 1x20 watt LED tube light fittings (4 feet long), prewired, decorative luminaire with inbuilt LED tube rod and acrylic end covers with all accessories and PVC Round/Square block for fixing of fittings and making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed. \n 28 Each
78 78 S &F the Bulk head light fitting LED type 10 watt complete with 10 watt LED and having IP-63 protection and fixing on wall/ceiling complete with all accessories and including connecting up with ceiling rose with & including PVC insulated and overall sheathed flexible copper conductor cable and including 3 core 0.50 Sqmm complete all as specified and directed.\n\n 8 Each
79 79 S &F building LED security light luminaries 45 W LED 5000K AC 230 volts, new generation saving & enviromental friendly long life versatile pressure die cast aluminium luminaries with high power LED as light source complete making connection with street light/ building security light box or OH line using PVC insulated and sheathed single core multi stranded copper conductor cable of size 1.5Sqmm including suitable size 32mm of bracket and light grade pipe for muntaining of fitting complete all as specified and directed.\n\n 2 Each
80 80 S&F Surface mounted 1x11 watt LED mirror light fittings , prewired, decorative luminaire with inbuilt LED tube rod and acrylic end covers with all accessories and PVC Round/Square block for fixing of fittings and making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed. \nNotes for Srl Item Nos 77 to 80:-\n1. Driver shall be potted antivibration type.\n2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be povided.\n3. CRI (Colou Rendring Index) of fixture shall be > 70.\n4. CCT (Colout Correlated Temprature of fixture shall be 5700K ± 300 K.\n5. System Lumen Efficacy shall be > 100Lm/W\n6. 10 KV separate Surge Protection shall be provided as a part of fitting.\n7. 5 years gurantee shall be provided by contractor suppoted by OEM covering all parts of luminaire. \n8. Lenses shall be Modular Type. \n9. PCB used shall be MC PCB type \n10. The defect liability period of LED light shall be 05 years from the certified date of completion & the Contractor shall replace / repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair \n11. CA No shall be written on each fitting before installation.\n 4 Each
81 81 M &L for Double door MCB DB VTPN, 415 Volts, 04 Way made out of CRCA powder coated sheets, IP43 protection with copper bus bar with & incl MCCB TPN 415 volts 63 Amps including taking out old unserviciable MCB DB any size/type, complete all as specified and directed. \nMake: Legrand Cat Part No 6077-50 or equivalent model in Legrand/Hager/SCHNEIDER \n 1 Each
82 82 S&F Double door MCB DB SPN, 240 Volts, 08 Way made out of CRCA powder coated sheets, IP43 protection with copper bus bar including taking out old unsv DB any size/type, complete all as specified and directed. \nMake: Legrand Cat Part No 6077-11 or equivalent model in L&T/Hager/SCHNEIDER 6 Each
83 83 S&F for MCB single pole (SP) 240 volts, 6 to 40 Amps, 10KA (B-series) , complete all as specified and directed.\nMake : Legrand/Schneider/Hager \n 46 Each
84 84 S&F for MCB single pole neutral (SPN) 240 volts, 32 to 40 Amps, 10KA (B-series) complete all as specified and directed.\nMake : Legrand/Schneider/Hager \n 6 Each
85 85 M&L for Sub main wiring with FRLS PVC insulated unsheathed 2X6 sqmm multistranded copper conductor cable 1100 V with 1X6 sqmm FRLS PVC insulated green multistranded copper cable for continuous earth drawn through & including concealed PVC conduit of appropriate size not less than 20 mm dia & 1.8mm wall thickness with all accessories including cutting grooves and making good disturbed surface to match existing including taking down existing surface sub main wiring complete all as specified and directed. \n(Note: Two runs of FRLS PVC cable with one run of earth conductor and conduit shall be measured as one RM.)\nMake for wiring : Polycab/Anchor/Finolex \n 57 RM
86 86 M&L for earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, HDPE pipe 15mm bore as protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed.\nNotes: \n1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor.\n2. Earth filling shall be done by vegitable soil.\n3. Soil shall be free from stone, boulders, aggregate, gravels . 3 Each
87 87 Taking down ceiling fan of any sweep & size and refix in same position after overhauling including minor repairs by replacement of capacitor, safety pin, cap, nuts & bolts etc and making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose to fan, including testing to ensure efficient functioning including application of one coat of synthetic enamel paint by spray painting & rewriting number complete all as specified and directed. 16 Each Job
88 88 Supply , laying, testing and commissioning for 1100 volt grade XLPE insulated heavy duty cable, 16 sqmm 2 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable & bricks complete all as specified and directed.\nNote : Excavation & Earthwork shall be measured and paid separately. 80 RM
89 89 Supply , laying, testing and commissioning for 1100 volt grade XLPE insulated heavy duty cable, 25 sqmm 4 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable & bricks complete all as specified and directed.\nNote : Excavation & Earthwork shall be measured and paid separately. 50 RM
90 90 M & L for sand filling in trenches dry and and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed. \n[Note : Punned thickness shall be measured and paid] 7 Cum
91 91 M & L for well burnt bricks , laid flat ( old size) sub class B designation 75 for cable protection complete all as specifed and directed. 0.728 per 1000 Nos
92 92 S&F for GI tubing 40 mm bore light grade laid in trenches/floors/ fixed to wall/poles for protection of cable with necessary fittings and FI clamps duly painted complete all as specified and directed. \n 18 RM
93 93 Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc (for cable, pole stay manhole etc), in any type of soil and getting out, complete all as specified and directed. 20 Cum
94 94 Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm thick, etc complete all as specified and directed. 12 Cum
95 95 Removing excavation material n exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point etc complete all as specified and directed. 9 Cum