Repair To Transformer Of Capacity 500 Kva With Sm No 263/3249/Tr/16 Under Ge ( North ) Patiala ( Make Crompton ) .

Issued by Statutory Bodies & Commissions/Committees · GE(N) PATIALA, Punjab
Tender Value
1.45 Lakhs
Estimated cost
Bid Submission
19 Sep 2019
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
GE(N) PATIALA → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair To Transformer Of Capacity 500 Kva With Sm No 263 / 3249 / Tr / 16 Under Ge ( North ) Patiala ( Make Crompton ) . , Repair To The Transformer Including Following:- ( A ) Taking Down Unsv Transformer From Site And Transporting To Yard . ( B ) Opening Of Top Cover And Lift Up Of Core For Inspection Of Defect Through Tripad And Chain Pulley Block . ( C ) Draining Of Transformer Oil ( D ) Taking Down And Replacement Of Windings Of Ht Side One Limb-4 Coils With New Coil Of Weight 50 Kg / Coil ( E ) Fixing Of New Coil In Limb ( F ) Baking Of Core In Furnace ( G ) Coating Of Tank With Zinc Chromate Paint To Avoid Rusting Of Tank ( H ) Lowering The Core In Tank And Filling Of 450 Ltrs Of Transformer Oil Of Specific Gravity 0 . 89 Max And Dielectric Strength Not Less Than 60 Kv ( J ) Fixing The Top Cover And Tap Changer Connection ( K ) Testing Of Transformer Before Installation At Site . ( L ) Transportation Of Transformer To Site For Intallation And Commission . Note:- 1 . Test Result Shall Be Recorded After Repair . 2 . Old Dismanteled Material I . E Transformer Oil And Coils Shall Be The Property Of Department .

BOQ

Name of Work: REPAIR TO TRANSFORMER OF CAPACITY 500 KVA WITH SM NO 263/3249/TR/16 UNDER GE (NORTH) PATIALA (MAKE : CROMPTON).
Item DescriptionItem Code / MakeQuantityUnits
1Repair to the transformer including following:- \n\n(a) Taking down UNSV transformer from site and transporting to yard.\n\n(b) Opening of top cover and lift up of core for inspection of defect through tripad and chain pulley block.\n\n(c ) Draining of transformer oil\n\n(d) Taking down and replacement of windings of HT side one limb-4 coils with new coil of weight 50 Kg/coil\n\n(e) Fixing of new coil in limb\n\n(f) Baking of core in furnace\n\n(g) Coating of tank with zinc chromate paint to avoid rusting of tank\n\n(h) Lowering the core in tank and filling of 450 ltrs of transformer oil of specific gravity 0.89 Max and dielectric strength not less than 60 KV\n\n(j) Fixing the top cover and tap changer connection\n\n(k) Testing of transformer before installation at site.\n\n(l) Transportation of transformer to site for intallation and commission.\nNote:- 1. Test result shall be recorded after repair.\n2. Old dismanteled material i.e transformer oil and coils shall be the property of Department.\n\n\n1Each

AI Tender Summary

OUR REF NO 21791550
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.45 Lakhs
LAST DATE 19-09-2019
Authority
Authority Name Military Engineer Services
Work Description Repair To Transformer Of Capacity 500 Kva With Sm No 263 / 3249 / Tr / 16 Under Ge ( North ) Patiala ( Make Crompton ) . , Repair To The Transformer Including Following:- ( A ) Taking Down Unsv Transformer From Site And Transporting To Yard . ( B ) Opening Of Top Cover And Lift Up Of Core For Inspection Of Defect Through Tripad And Chain Pulley Block . ( C ) Draining Of Transformer Oil ( D ) Taking Down And Replacement Of Windings Of Ht Side One Limb-4 Coils With New Coil Of Weight 50 Kg / Coil ( E ) Fixing Of New Coil In Limb ( F ) Baking Of Core In Furnace ( G ) Coating Of Tank With Zinc Chromate Paint To Avoid Rusting Of Tank ( H ) Lowering The Core In Tank And Filling Of 450 Ltrs Of Transformer Oil Of Specific Gravity 0 . 89 Max And Dielectric Strength Not Less Than 60 Kv ( J ) Fixing The Top Cover And Tap Changer Connection ( K ) Testing Of Transformer Before Installation At Site . ( L ) Transportation Of Transformer To Site For Intallation And Commission . Note:- 1 . Test Result Shall Be Recorded After Repair . 2 . Old Dismanteled Material I . E Transformer Oil And Coils Shall Be The Property Of Department .
Basic Detail
Tender No 3001/JOB/2019-20/01/E3 dated 13 Sep 2019
Bidding Type Tender
Location
City GE(N) PATIALA
State Punjab
Key Dates
Publish Date 13 Sep 2019
Submission Date 19 Sep 2019
Open Date 20 Sep 2019
Finance
Tender Value 1.45 Lakhs
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
FCAEB170-6AC7-47DB-9B80-6DDAC3E308C4.html
Tendernotice_2.pdf
BOQ_316760.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 13, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 19, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 20, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

FCAEB170-6AC7-47DB-9B80-6DDAC3E308C4.html

pdf

Tendernotice_2.pdf

xls

BOQ_316760.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders