}

Retrofitting Of Mcc Panels For Replacement Of Electromechanical Relays With Numerical Retrofitting Of Mcc Panels For Replacement Of Electromechanical Relays With NumericalReplays For Phbpl Bolpur Pump Station . , PHBPL BOLPUR-West Bengal

Indian Oil Corporation Limited has published Retrofitting Of Mcc Panels For Replacement Of Electromechanical Relays With Numerical Retrofitting Of Mcc Panels For Replacement Of Electromechanical Relays With NumericalReplays For Phbpl Bolpur Pump Station . . Submission Date for this Tender is 27-09-2019. Electrical Panel Tenders in PHBPL BOLPUR West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

21784811
Retrofitting Of Mcc Panels For Replacement Of Electromechanical Relays With Numerical Retrofitting Of Mcc Panels For Replacement Of Electromechanical Relays With NumericalReplays For Phbpl Bolpur Pump Station .
Open Tender
Indian
West Bengal
Phbpl Bolpur
27-09-2019

Tender Details

Retrofitting Of Mcc Panels For Replacement Of Electromechanical Relays With Numerical Retrofitting Of Mcc Panels For Replacement Of Electromechanical Relays With NumericalReplays For Phbpl Bolpur Pump Station . , Numerical And Programmable 3-Phase Feeder Protection Relay Type Siemens-7Sr1004 , Micom-P14db Or Any Similar Equivalent Model . Make:Siemens/Alstom/Schneider/Ge/L&T Or Any Similar Equivalent Make . Auxiliary Power Supply : Relay Shall Be Suitable For Aux Supply Operating Range From 60V To 240 Vac /Dc . Current Inputs: Relay Shall Have Site Selectable 1A/5A Current Inputs . Voltage Inputs : Relay Shall Have Min . 03 Voltage Inputs For Measurement Of Pt Voltage . Shall Have Phase To Phase & Phase To Neutral Voltage Measurement . Protections : 50 , 51 , 50N , 51N , 67 , 37 , 51C , 46Bc , 46 , 49 , 50Bf , 81Hb12 , 27 , 59 , 81 , 47 Etc . Supervision: Cts , Vts , T/Ccs , ThdMonitoring: Primary/Secondary Current Phases And EarthPrimary/Secondary Line And Phase VoltagesApparent Power And Power FactorReal And Reactive PowerPositive Phase Sequence ( Pps ) Voltage &Negative Phase Sequence ( Nps ) Voltage & CurrentZero Phase Sequence ( Zps ) Voltage And CurrentFrequencyTotal Harmonic DistortionTrip Circuit Healthy/FailureFault RecordsEvent RecordsCircuit Breaker Trip CountersThermal Overload Status Monitoring . Communication Port : Dnp 3 . 0 ( Rs485 ) /ModbusCommunication Protocol : Iec 61850Flush Mountable , Watchdog Relay With Programmable Leds . Software For Setting And Fault Record - 2 Cds Required , SuitableFor Xp Operating System . Five Sets Of Operation /Application Manual To Be Supplied Along With The Lot In Hardcopy . , Numerical And Programmable 3-Phase Motor Protection Relay Type Siemens-7Sr1706 , Micom-P24dm Or Equivalent Or Any Similar Equivalent Model . Make:Siemens/Alstom/Schneider/Ge/L&T Or Any Similar Equivalent Make . Auxiliary Power Supply : Relay Shall Be Suitable For Aux Supply Operating Range From 60V To 240 Vac /Dc . Current Inputs: Relay Shall Have Site Selectable 1A/5A Current Inputs . Voltage Inputs : Relay Shall Have Min . 03 Voltage Inputs For Measurement Of Pt Voltage . Shall Have Phase To Phase & Phase To Neutral Voltage Measurement . Protections :50 , 51 , 50N , 51N , 67 , 37 , 49 , 46 , 50Bf , 81B , 27 , 59 , 81 , 14 , 48/66 Etc . Supervision: Cts , Vts , T/Ccs . Monitoring: Primary/Secondary Current Phases And EarthPositive Phase Sequence ( Pps ) CurrentNegative Phase Sequence ( Nps ) CurrentZero Phase Sequence ( Zps ) CurrentTrip Circuit Healthy/FailureFault RecordsEvent RecordsCircuit Breaker Trip CountersThermal Overload Status MonitoringCommunication Port : Dnp 3 . 0 ( Rs485 ) /ModbusCommunication Protocol : Iec 61850Flush Mountable , Watchdog Relay With Programmable Leds . Software For Setting And Fault Record - 2 Cds Required , SuitableFor Xp Operating System . Five Sets Of Operation /Application Manual To Be Supplied Along With The Lot In Hardcopy . [Please Ignore The Make & Type Of Relay In The Header & Po Text . ] , Retrofitting Service Work And Commission

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail