Tender For Repairs/Maintenance Of Geyser , Solar Water Heater And Summer / Cooling Appliances At Adm Area , Cpe , Itarsi, Itarsi-Madhya Pradesh

Military Engineer Services-MES has published Tender For Repairs/Maintenance Of Geyser , Solar Water Heater And Summer / Cooling Appliances At Adm Area , Cpe , Itarsi. Submission Date for this Tender is 02-10-2019. Air Conditioner Tenders in Itarsi Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

21780967
Tender For Repairs/Maintenance Of Geyser , Solar Water Heater And Summer / Cooling Appliances At Adm Area , Cpe , Itarsi
Open Tender
Indian
Madhya Pradesh
Itarsi
02-10-2019

Tender Details

Tender For Repairs/Maintenance Of Geyser , Solar Water Heater And Summer / Cooling Appliances At Adm Area , Cpe , Itarsi

Key Value

Document Fees
INR 500 /-
EMD
INR 10600.0 /-
Tender Value
INR 5.30 Lakhs /-

BOQ Items

Name of Work: RAPAIRS/MAINTENANCE OF GEYSER, SOLAR WATER HEATER AND SUMMER / COOLING APPLIANCES AT ADM AREA, CPE, ITARSI
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down ceiling fans/ exhaust fan / wall bracket fan of any sweep and make from any position carefully including disconnection of electric supply and deassembling of blades from fan and deposit in MES store for carrying out necessary repair/rewinding i.e overhauling, painting etc complete all as specified and directed. 244 EACH\nJOB
2 2 Removing the burnt out copper winding of ceiling fans of any make of size 1200 mm sweep and rewinding with super enamelled copper wire of approved quality of existing gauge and size including necessary insulation with leathoroid sheet varnishing of winding of coil, packing, proper insulation, gasket etc., including cleaning the rotor and the stator, overhauling, lubricating with fresh graese, assembling including rehanging in position, testing and commissioning complete all as specified and directed. 110 EACH\nJOB
3 3 All as per item No. 2 here in above but size 1400 mm sweep. 60 EACH\nJOB
4 4 All as per item No. 2 here in above but for exhaust fan of size 300 mm sweep. 6 EACH\nJOB
5 5 All as per item No. 2 here in above but for size 450 mm sweep. 5 EACH\nJOB
6 6 All as per item No. 2 here in above but wall bracket fan of any sweep. 3 EACH\nJOB
7 7 Opening up ceiling fan of any make and any sweep for overhauling such as cleaning the rotor and the stator, overhauling, lubricating with fresh oil/ graese, reassembling for proper running including rehanging in position and connecting up, testing and commissioning complete all as specified and directed.\nNote: Any unserviceable/burnout parts replaced shall be measured and paid separately under relavent items. However quoted rates shall be deemed to be included for rectification of any defect in the fan. 60 EACH \nJOB
8 8 Supply only capacitor 2.5/3.15 mfd, 230 volts for ceiling fans 1200/1400 mm sweep and any make complete all as directed.\nMake: Keltron/Havells/Crompton/Bajaj. 170 EACH
9 9 Supply only capacitor 4 mfd suitable for exhaust fans 300/450 mm sweep complete all as directed.\nMake: Keltron/Havells/Crompton/Bajaj. 10 EACH
10 10 Supply only ball bearing suitable for ceiling fan sweep 1200 mm complete all as directed. Make: NBC/SKF. 40 EACH
11 11 Supply only ball bearing suitable for ceiling fan sweep 1400 mm complete all as directed. Make: NBC/SKF. 20 EACH
12 12 Supply and fix split pin suitable for ceiling fan/exhaust fan of any sweep and make complete all as directed. 50 EACH
13 13 Supply only thrust rubber suitable for ceiling fan of any make and size. 50 EACH
14 14 Supply only self lubricating bush of gun metal as per ceiling fan/exhaust fan complete all as directed. 25 EACH
15 15 Supply only shaft of approved quality for ceiling fan/exhaust fan any make, type and size complete all as directed. 5 EACH
16 16 Supply and fix isolating gear suitable for bracket fan of any type and size complete all aspecified and directed. 5 EACH
17 17 Material and labour for preparing the surface of body/blades of ceiling fan, any sweep and make, applying one coat of spray paint with synthetic encamel white paint and writing the MES No. maker's serial No. etc with sythentic enamel black paint 1.5cm high letters complete all as directed. 170 EACH
18 18 S&F Electronic step type Fan regulator socket type 120/280 watt capacity including connecting up complete.make-Anchor or leader\nMake- Crompton/Havells/Anchor/KHAITAN/Leader 80 Each
19 19 Supply and fix PVC insulated, unsheathed three core copper flexible cable of size 2.5 sqmm including connection complete all as directed.\nMake- Havells / L&T / Anchor/ Polycab/Finolex 200 RM
20 20 Supply and fix PVC insulated, unsheathed three core copper flexible cable of size 1.5 sqmm including connection complete all as directed.\nMake- Havells / L&T / Anchor/ Polycab 200 RM
21 21 Supply and fix stop valve / angle valve cast copper alloy, screwed down, high pressure with ctutch or butterfly handles, screwed both ends for iron pipe 15mm dia complete all as specified and directed. Make- Leader/Zoloto/Vardhman/BIR Jalandhar 10 EACH
22 22 Supply and fix bib tap cast copper alloy, screwed down, high pressure with ctutch for iron pipe 15mm dia complete all as specified and directed. Make- Parryware/Jaquar/Cera/Marc/Seiko/Gem 10 EACH
23 23 Supply and fix hermetically sealed unit compressor, semi spherical type, working on 230 volts, 50 Hz suitable for water cooler of capacity 40 to 80 litrs including first fill of refrigerant gas, breezing jointing leak testing and commissioning complete all as specified and directed. \nMake-Kenstar/Crompton/Havells/Voltas/Blue Star 2 EACH \nJOB
24 24 Supply and fix hermetically sealed unit compressor, semi spherical type, working on 230 volts, 50 Hz suitable for window type AC, 1.5 ton capacity including first fill of refrigerant gas, breezing, jointing, leak testing and commissioning complete all as specified and directed.\nMake-Kenstar/Crompton/Havells/Voltas/Blue Star 2 EACH \nJOB
25 25 Supply and fix hermetically sealed unit compressor, semi spherical type, working on 230 volts, 50 Hz suitable for split AC 1.5 ton including first fill of refrigerant gas, breezing, jointing, leak testing and commissiong complete all as specified and directed.\nMake-Kenstar/Crompton/Havells/Voltas/Blue Star 2 EACH \nJOB
26 26 Supply and fix in repair out door unit for spit type air conditioner 1.5 ton including condenser, blower motor with fan and hermetically sealed unit compressor, semi spherical type, working on 230 volts, 50 Hz, first fill of refrigerant gas, complete with refrigerent gas tube connection and electrical connectin terminal with commissiong complete all as specified and directed.\nMake :- Carrier/Voltas/Samsung/Daikin 2 EACH \n
27 27 Material and labour for repairing of split/window air conditioner, water cooler, refregerator, arresting the leackage with nitrogen gas with adequet pressure replacing the deffective parts like, blower motor, copper tubing, condenser motor, thermostate, over load relay, condenser, starting relay, filling the refrigerent gas after vaccuming etc. and making the appliances serviceable complete all as per specified and directed.\nNote:-\n(i). Nitrogen gas for testing of leackage will be supplied by the contractor and rate for the same shall be deemed to be included in unit rate quoted. \n(ii). Blower motor, copper tubing, condenser motor, thermostate, over load relay, condenser, starting relay, filling the refrigerent gas shall be measured and paid under relavent items. 10 EACH JOB
28 28 Supply only 1/4" copper tubing for AC water cooler and refrigerator complete all as directed. 0.5 KG
29 29 Supply only 1/8" copper tubing for AC water cooler and refrigerator complete all as directed. 0.5 KG
30 30 Supply and fix 60-80 MFD starting capacitor complete all as directed.\nMake- Voltas/Blue star/Zeco/Accel/Carrier\n 3 EACH
31 31 All as per item No. 30 here in above but 80 -100 MFD.\nMake- Voltas/Blue star/Zeco/Accel/Carrier 3 EACH
32 32 All as per item No. 30 here in above but 100 -120 MFD.\nMake- Voltas/Blue star/Zeco/Accel/Carrier 3 EACH
33 33 Supply and fix 36 MFD running capacitors complete all as directed.\nMake- Voltas/Blue star/Zeco/Accel/Carrier 3 EACH
34 34 All as per item No. 33 here in above but 25 MFD.\nMake- Voltas/Blue star/Zeco/Accel/Carrier 3 EACH
35 35 All as per item No. 33 here in above but 16 MFD.\nMake- Voltas/Blue star/Zeco/Accel/Carrier 3 EACH
36 36 All as per item No. 33 here in above but 8 MFD.\nMake- Voltas/Blue star/Zeco/Accel/Carrier 3 EACH
37 37 Supply and fix over load protector as per existing make, sizes, model and capacity suitable for existing compressor of water cooler, refrigerator, air conditioner etc.,\ncomplete all as directed. 5 EACH
38 38 Supply and fix thermostate switch with knob for window type air conditioner existing make complete all as directed. 4 EACH
39 39 All as per item No. 38 here in above but for water cooler and refrigerator. 4 EACH
40 40 Supply and fix push type tap 15mm bore, brass chromium plated for water cooler complete all as directed.Make- ISI marked or as approved by GE 4 EACH
41 41 Supply and fix blower motor, 230 volts, single phase, 50Hz suitable for AC, water cooler of 1/4 HP capacity complete all as specified and directed. \n 4 EACH
42 42 All as per item No. 41 here in above but 1/6 HP capacity. 3 EACH
43 43 Supply and fix starting relays as per existing sizes/ model suitable for existing compressor of water cooler, air conditioner etc., complete all as directed.\n 5 EACH
44 44 Removing storage type water cooler of capacity 40 to 80 litrs from site and refixing the same after carry out the following works complete all as and directed:-\n(i) Rubbing the water cooler body after cleaning the complete body/surface fully rust free and applying putty wherever required. \n(ii) Applying two coats of superior quality synthetic enamel paint over one coat of red oxide primer to the outer surface except back side.\n(iii) Applying one coat of corrosive resistant paint and one coat of spray enamel paint inside including tinkering of sheet where ever required.\n(iv) Oiling/ greasing to fan motor.\n(v) Back side of water cooler shall be painted by black paint including marking the serial No. MES No _ _ . etc., on the cooler. \nNote: Painting shall be applied by spray machine only. 2 EACH \nJOB
45 45 Supply and charging of refrigrent R-22 gas for water cooler, AC, and refrigerator up to desired pressure complete all as directed.\n\n 10 KG
46 46 Supply and charging of Refrigerent R-134a gas for water cooler, AC, and refrigerator up to desired pressure complete all as directed.\nNote for Sl. item Nos. 46 and 47 :- Refrigerent gas shall be supllied in sealed container only.\n\n 8 KG
47 47 Supply and fix box/ pin type relay for compressor protection of refrigerator as per existing, including testing complete all as directed. 3 EACH
48 48 Taking down window/ split type AC from existing bracket/ support for cleaning internally oiling, greasing of blower motor/ fan including painting the chasis, wrtting MES No. etc., and refixing in position complete all as directed. 6 EACH \nJOB
49 49 Supply and install capacitor, metalized poly propylene heavy duty (MPP-H) three phase, 415 volts and 50 Hz system for permissible non-linear load 15 % of 5 KVAR capacity complete all as directed. 2 EACH
50 50 Material and labour for comprehensive maintenance of storage type geyser 25/50 litrs cpacity of any make and any description and carrying out the work such as cleaning of inlet and outlet water tubing removing of any leakage in geyser assembly and pipes including checking of electric connection and proper earthing to geyser, refixing after repair/ replacement of worn out nuts, bolts and washers etc., complete all as directed.\nNote: Spare parts of the geyser if any replaced shall be measered any paid under relavant item. 25 EACH \nJOB
51 51 Supply only heating element push type, single phase, 1.5 KW complete all as directed.\nMake: Bajaj/Racold/Usha/kraft. 15 EACH
52 52 Supply only heating element traingle type, single phase, 1.5 KW complete all as directed.\nMake: Bajaj/Racold/Usha/kraft. 10 EACH
53 53 Supply only themostate 9"/12" required for any type of geyser capacity 25/50 litrs with temperature adjustable knob and range of temparetur 0-80 degree celceius complete all as directed. 25 EACH
54 54 Supply only geyser assembly for any type of geyser of capacity 25 litrs with rubber gasket, nuts, bolts and washers complete all as directed. 2 EACH
55 55 Supply only indicator lamp with holder of required colour for any type of geyser of capacity 25/50 litrs with rubber gasket, nuts bolts and washers complete all as directed.\nMake-L&T/Legrand/Siemens/C&S/HPC/BCH/ABB 10 EACH
56 56 Supply and fix PVC connection of 15mm size, spirally reinforced with stainless steel wire inside the pipe for outlet hot water pipe connection with brass nuts at both ends of length 450 mm complete all as directed. 30 EACH
57 57 M&L Scrapping the old painted surfaces of geyser, cleaning and painting with two coats of white synthetic enamel paint over & including a coat of red oxide primer including writing MES No. with black paint with minimum 25 mm size of letters all as directed at site for 25 liters capacity geysers complete. 5 Each
58 58 Supply and replacement of water lifting pump (water immersed) for desert cooler with model - HM - 09, 240 volts, 50 Hz, 12 watts, 1.5 metre max head and output 800 LPH complete all as directed. \nMake: Kenstar/Khaitan/Crompton/Havells/Blue Star 10 EACH
59 59 Supply and fix khas pads/wood wool pad of required size for desert cooler of any make complete all as directed. 10 SET\n OF\nTHREE
60 60 Supply and fix blower motor, 230 volts, single phase, 50 Hz, suitable for desert cooler size 450/600mm as per site requirement including kit consists of mounting clamps, blades, speed contol switch, nut, bolts and washers complete all as specified and directed Make: CG/Cool home/Bajaj 12 EACH
61 61 Repair the the unserviceable solar water heating system and making serviceable by filling the Distilled water, cleaning the solar touch end glass, stopping the leackage with replacing the old unserviceable CPVC pipe/tee/bend/broken glass tubes etc. complete all as specified and directed. Note: CPVC pipe /glass tubes,CPVC acessories will be measured and paid saperately in respective item. 5 Each Job
62 62 Supply and fixing in repair 20 mm external dia Chlorinated Poly Vinyl Chloride (CPVC) pipe consisting of high grade polymer effectively bonded in the inside and outside of an aluminium tube CPVC-AL-CPVC by melt adhesive(including joining/fixing with cement solvent) suitable for hot water supply from solar water heater to the bathrooms and fixed to wall, ceiling etc. including all materials, fittings and fixing works and testing of pipe line test for solvent cement joints and adhesive joints and testing of all materials shall be as per manufactures instructions, literature and confirming to IS-15450 : 2004 or ASTM -1282 including making good the disturbed surfaces complete all as specified and directed. 25 RM
63 63 S & F in repair Special grade Borocilicate glass tube length of tube 1500 mm tube outer diameter 47 mm inner tube diameter 37 mm with selective absorption coating layer make on tube Tata BP compatible with 100 LPD and 200 LPD solar water heater .complete all as specified and directed, 8 No
64 64 S & F in repair 100 LPD Tata BP make Puf insulated hot water storage tank for 100 LPD solar water heater storage tank material 316 grade stanless steel outer clading material powdar coated GI sheet. complete all as specified and directed, 1 Each
65 65 S&F in repair anti rust ring for 1500 x 47 mm size special grade borocilicate glass tube (pack of 20 pieces each) complete all as specified and directed, 5 Each
66 66 S&F in repair silicon ring for 1500 x 47 mm size Tata BP special grade borocilivate glass tube (pack of 20 pieces each) complete all as specified and directed, 5 Each
67 67 S&F in repair plastic tube holder for 1500 x 47 mm size Tata BP special grade borocilivate glass tube (pack of 20 pieces each) complete all as specified and directed. 5 Each
68 68 S&F in repair brass elbo suitable for CPVC pipe line of size 20 mm complete jointing etc all as specified and directed. 6 Each
69 69 S&F in repair brass Tee suitable for CPVC pipe line of size 20 mm complete jointing etc all as specified and directed. 6 Each
70 70 S&F in repair Female brass threaded adopter suitable for CPVC pipe line of size 20mm complete jointing etc all as specified and directed. 6 Each
71 71 S&F in repairs Sheet metal inclosure with earth plug and socket single pole and neutral with single pole MCB 20 Amps 240 volts complete all as directed. Make- Havells//Schneider/Legrand / C&S/L&T 10 Each
72 72 M&L for repairing of RO based aqua guard installed for water cooler , with replacement of candle, checking of AC supply circuitary of aqua guard and made functional, replacement of step down transformer 230 volt to 12/24 volts, as per sample and complete all as directed at site. 2 Each
73 73 S&F in repair /Replacement of Membrane of RO plant machine capacity 50 Ltr/Hrs Make- Ureka Forbs/Aqua Guard 6 Each
74 74 S&F in repair /Replacement of Pree filter candle RO plant machine capacity 50 Ltr/Hrs, Activated carbon granuals twice and carbon black 2 Each
75 75 S&F in repair /Replacement of Diaphragm Pump 24 volt DC and open flow minimum 2.0 Ltr/min as per site requirement. Make- Ureka Forbs/Aqua Guard 4 Each
76 76 S&F in replacement of worn out/exhausted parts during the servicing such as Step down transformer and PCB with parts and all electrical parts / PVC pipes small pices for inlet and outlet connection of unit as per site requirement. 2 Each Job
77 77 Supply and fixing of heavy duty exhaust fan 300 mm sweep, turbo force 1400 RPM, single phase,totally enclosed heavy uty motor, with copper winding, aluminium rotor mounted on 2 ball bearings including mounting brackets fixing on frame complete all as specified and directed. Make Havells /CG/ Bajaj/Almonard/USHA/Khaitan/Orient 4 Each
78 78 Supply and Replacement of voltage stabilizer of capacity 3 KVA installing and testing complete all as specified and directed. Make- Blue Star/V Guard/SINETRAC/APLAB/BRENTFORD 4 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail