| 1 | 1 | WIRING SYSTEM\nLIGHT POINT WIRING \n\nWiring for the following light points with 1.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires of approved make in MMS PVC conduit With accessories including providing and fixing of 6 amps single pole rocker operated flush mounted switch of approved quality colour make & design mounted on 1.6 mm thick GI box with earthing of fixtures and the outlet box with 1.5 sq.mm PVC insulated copper conductor stranded flexible \"FRLS\" wire. | | | |
|---|
| 2 | 1.01 | Primary light point include 6 amps single pole rocker operated flush mounted switch with 3runs 1.5sqmm CU FRLS flexible wires in 20mm MMS PVC conduit (from switch board to first light point - cost of switch, Metal box & board included) | | 33 | Nos |
|---|
| 3 | 1.02 | Primary light point from DB to first light point with 3runs 1.5sqmm CU FRLS flexible wires in 20mm MMS PVC conduit with all accessories & metal box is also included - (cost of MCB not included) | | 3 | Nos |
|---|
| 4 | 1.03 | Secondary light point with 3runs 1.5sqmm CU FRLS flexible wires in 20mm MMS PVC conduit with all relevant accessories without switch ( from light point to light point - cost of switch & board NOT included). | | 38 | Nos |
|---|
| 5 | 1.04 | Wiring for one way ceiling fan point with 1.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible \"FRLS\" wires in MMS PVC conduit including fan hook box, 6 amps switch and 100 watts socket type Step fan regulator of approved make in GI box and earthing the fan and outlet box with 1.5 sq. mm. PVC insulated copper conductor stranded flexible FRLS wire. | | 8 | Nos |
|---|
| 6 | 1.05 | Wiring for Exhaust fan point with 1.5 sq. mm. Insulated copper conductor 1100 volts grade stranded flexible FRLS wires of approved make in MMS PVC conduit including providing and fixing of 6 amps flush mounted switch at the normal switch level in 1.6 mm thick GI box and 6 amps 3 pin flush mounted socket outlet near exhaust fan and earthing of exhaust fan through the third pin of the socket outlet and GI box with 1.5 sq. mm. PVC insulated copper conductor flexible FRLS wire. | | 6 | Nos |
|---|
| 7 | 2 | POWER RECEPTACLES AND ISOLATORS | | | |
|---|
| 8 | 2.01 | Providing and fixing of 6/16 amps universal switch socket with 16 amp one way rocker operated flush mounted switch of approved make and design in 1.6 mm thick GI box with grid plates including the termination of wires with copper lugs and insulating the end with pvc tape. | | 6 | Nos |
|---|
| 9 | 2.02 | Providing and fixing of 6 amps 5 pin universal socket with 6 amp one way rocker operated flush mounted switch of approved make and design in 1.6 mm thick GI box with grid plates including the termination of wires with copper lugs and insulating the end with pvc tape. | | 6 | Nos |
|---|
| 10 | 2.03 | Providing and fixing of 32 amps 3ph 5 pin Metal Clad / MDF socket with 32 amp MCB of approved make and design in 1.6 mm thick GI box or MS Encloser or with grid plates including the termination of wires with copper lugs and insulating the end with pvc tape. | | 3 | Nos |
|---|
| 11 | 2.04 | Supply, installation, testing and commissioning of 32 amps 4 pole ELCB / RCCB 100 / 300mA in 1.6 mm thick MS enclosure of approved make design and painted with approved paint shade. | | 3 | Nos |
|---|
| 12 | 2.05 | Supply, installation, testing and commissioning of 40 amps 4 pole ELCB / RCCB 100/ 300mA in 1.6 mm thick MS enclosure of approved make design and painted with approved paint shade. | | 1 | Nos |
|---|
| 13 | 2.06 | Supply, installation, testing and commissioning of 63 amps 4 pole ELCB / RCCB 100 / 300mA in 1.6 mm thick MS enclosure of approved make design and painted with approved paint shade. | | 2 | Nos |
|---|
| 14 | 2.07 | Providing and fixing of 25 amps socket with 25 amp one way with Indicator rocker operated flush mounted switch of approved make and design in 1.6 mm thick GI box with grid plates including the termination of wires with copper lugs and insulating the end with pvc tape.(for Geyser/Oven) | | 1 | Nos |
|---|
| 15 | 3 | LIGHTING/POWER CIRCUIT MAIN\nProviding and fixing of following PVC insulated copper conductor 1100 volt grade stranded flexible FRLS wire in MMS PVC conduit concealed or surface mounted making connections where ever required to complete the installation. | | | |
|---|
| 16 | 3.01 | 2 runs 2.5 sqmm and 1 run 1.5sqmm (earth) wires in 20mm dia PVC Conduit | | 800 | Rm |
|---|
| 17 | 3.02 | 2 runs 4 sqmm and 1 run 2.5sqmm (earth) wires in 20mm dia PVC Conduit | | 300 | Rm |
|---|
| 18 | 3.03 | 2 runs 6 sqmm and 1 run 4.0sqmm (earth) wires in 20mm dia PVC Conduit | | 200 | Rm |
|---|
| 19 | 3.04 | 2 runs 10 sqmm and 1 run 6.0sqmm (earth) wires in 20mm dia PVC Conduit | | 10 | Rm |
|---|
| 20 | 4 | M.V.CABLES\nSupplying, laying, testing and commissioning of 1100V grade XLPE insulated steel wired/ tape armoured, unarmoured, aluminium/ copper conductor cables . The cables shall be laid in concrete trenches or buried directly underground or on cable trays. The concrete trenches will be measured separate. The cost of the cable trays or ladders, excavation and back filling of trenches will be measured separate. the unit cost of the cable shall include clamps, fasteners etc. as required for proper installation. | | | |
|---|
| 21 | 4.01 | 3.5C 50sqmm A2XFY cable | | 60 | Rm |
|---|
| 22 | 4.02 | 3.5C 35sqmm 2XWY cable | | 30 | Rm |
|---|
| 23 | 4.03 | 4C 10sqmm 2XWY cable | | 1 | Rm |
|---|
| 24 | 4.04 | 4C 6sqmm 2XWY cable | | 100 | Rm |
|---|
| 25 | 4.05 | 4C 4sqmm 2XWY cable | | 1 | Rm |
|---|
| 26 | 4.06 | 4C 2.5sqmm 2XWY cable | | 60 | Rm |
|---|
| 27 | 5 | Providing & Installation of cable terminations for the above cables including Double compression type chrome plated brass glands and lugs(crimping type), PVC taping with Gland Cap & sleeves as required and all accessories complete. | | | |
|---|
| 28 | 5.01 | 3.5C 50 sqmm A2XFY cable | | 4 | Nos |
|---|
| 29 | 5.02 | 3.5 35sqmm 2XWY cable | | 8 | Nos |
|---|
| 30 | 5.03 | 4C 10sqmm 2XWY cable | | 4 | Nos |
|---|
| 31 | 5.04 | 4C 6sqmm 2XWY cable | | 6 | Nos |
|---|
| 32 | 5.05 | 4C 4sqmm 2XWY cable | | 6 | Nos |
|---|
| 33 | 5.06 | 4C 2.5sqmm 2XWY cable | | 4 | Nos |
|---|
| 34 | 6 | LIGHT FIXTURES (For Common area only)\nSupply, Installation, testing and commissioning of following type of light fixtures as per drawings and specifications with all other accessories such as supporting rods / frames, anchor fasteners, necessary hardware etc. The rate shall include for fittings along with transformers where required, diffuser, chokes, starter, power factor improvement capacitors, wires, downrods etc., complete with all accessories to complete the installation as required.Note: all the ballast to be of electronics type. | | | |
|---|
| 35 | 6.01 | 1x18 - LED Downlighter | | 39 | Nos |
|---|
| 36 | 6.02 | 1x7 W Mirror optic light | | 7 | Nos |
|---|
| 37 | 6.03 | 36W panel light | | 19 | Nos |
|---|
| 38 | 6.04 | Strip Light | | 1 | Mtr |
|---|
| 39 | 6.05 | 1x10 W - Floor Washer Light (TPW1162) | | 4 | Nos |
|---|
| 40 | 6.06 | Wall Bracket Light | | 6 | Nos |
|---|
| 41 | 6.07 | Curve Light Point | | 1 | Nos |
|---|
| 42 | 6.08 | LED TUBE LIGHT 20W | | 7 | Nos |
|---|
| 43 | 7 | EARTHING SYSTEM\nSupplying, storing, shifting and fixing of following bare copper/ GI strips / wires in horizontal vertical runs including jointing, riveting etc. as per relevant specifications and all necessary fixing accessories, saddles, clamps, hardware’s, etc and effecting connections including tinning and riveting the joints Earthing system shall comply to IS:3043-1987. All equipment motors, DBs, panels to be connected on both ends (double earthing) with suitable strip/ wires | | | |
|---|
| 44 | 7.01 | Providing Chemical Earthing Ashlok Type 75mm dia GI 2.5 M long Electrode burried in ground with alternate layer of Charcoal & graphite powder including construction of masonary chamber with CI Cover. | | 2 | Nos |
|---|
| 45 | 7.02 | 50 mm x 6 mm thick GI strip | | 1 | RM |
|---|
| 46 | 7.03 | 50 mm x 6 mm thick CU strip | | 20 | RM |
|---|
| 47 | 7.04 | 25 mm x 3 mm thick CU strip | | 40 | RM |
|---|
| 48 | 7.05 | 25 mm x 3 mm thick GI strip | | 1 | RM |
|---|
| 49 | 7.06 | Single core 16 sq mm green colour copper cable | | 20 | RM |
|---|
| 50 | 8 | SMALL DISTRIBUTION BOARDS\nDesign, supply, installation, testing and commissioning of following miniature type circuit breaker type boards, wall mounted (flush / surface) as per drawings and specifications and as required. The distribution board shall be of sheet steel enclosure with copper busbars suitable for single phase or three phase MCBs. The MCBDB shall have sheet steel hinged lockable door top to prevent access to MCBs from outside. The DB shall have suitable neutral and earth terminal block to facilitate easy termination of wires. All wires inside the DBs shall be terminated using copper end terminations with labelling of each outgoing circuits . All dbs shall be of double door type. | | | |
|---|
| 51 | 8.01 | LPDB-1 MCB TPN DB\nIncomer having:\n1NO -MCCB 4P 200A 36KA\n1set of Phase indicating lamps\nOutgoing feeders:\n3NOS - 63/ A FP, 10 KA, 300 / 100mA, RCCB\n10NOS - MCB FP 32A 10 Nos. MCB 63A FP | | 1 | Nos |
|---|
| 52 | 8.02 | LPDB-2(8WAY TPN)\nIncomer having:\n3nos(1) - 40A, DP ELCB 300mA10kA, \nOutgoing feeders:\n18 (10) -16/10/6A SP, 10KA, MCB | | 1 | Nos |
|---|
| 53 | 8.03 | VTPNDB - (12WAY TPN) \nIncomer having:\nOne(1) - 100A FP, ELCB 300mA 10kA, \nOutgoing feeders:\n63A TP MCB - 04\n16A/32A/MCB TP - 06 | | 1 | Nos |
|---|
| 54 | 8.04 | EDB - (8WAY SPN) \nIncomer having:\nOne(1) -25 /32 / 40A DP, ELCB 100 / 300mA 10kA, \nOutgoing feeders:\n6NOS -16/10/6A SP, 10KA, MCB | | 1 | Nos |
|---|
| 55 | 9 | VOICE, TV & DATA\nSupply and fixing of embeded medium duty PVC MMS conduit as per IS 9537 part-3 or surface mounted of following sizes including cost of junction boxes, bends, elbows, sockets, tees etc. laying in slab, cutting chasis and making good or surface mounted including all fixing hardware. | | | |
|---|
| 56 | 9.01 | 20MM MMS PVC CONDUIT | | 400 | Rm |
|---|
| 57 | 9.02 | 25MM MMS PVC CONDUIT | | 1 | Rm |
|---|
| 58 | 9.03 | 32MM MMS PVC CONDUIT | | 1 | Rm |
|---|
| 59 | 9.04 | Supply and wiring for TELEPHONE system using 2 pair 0.5SQMM CU ANNEALED UTP cable. PVC conduits rate NOT to be included. | | 210 | Rm |
|---|
| 60 | 9.05 | Supply and wiring for TV system using RG-6 co-axial cable (copper conductor only)of MATV as per the specification. PVC conduits rate NOT to be included. | | 20 | Rm |
|---|
| 61 | 9.06 | Supply and wiring for TV system using RG-11 co-axial cable of MATV as per the specification. PVC conduits rate NOT to be included. | | 60 | Rm |
|---|
| 62 | 9.07 | Supply and wiring for DATA system using 4 pair Category 6 LAN cable consisting of 24 AWG solid copper conductors and as per the specification. The cable shall have flexible jacket and ripcord for easy Stripability. PVC conduits rate NOT to be included. | | 200 | Rm |
|---|
| 63 | 9.08 | Supply, installation, testing and commissioning of clip on type voice outlets mounted on a GI outlet box with front plate and all necessary accessories complete as required including the termination of wires. (RJ 11) | | 7 | No |
|---|
| 64 | 9.09 | Supply, installation, testing and commissioning of plug on type data point mounted on a GI outlet box with front plate and all necessary accessories complete as reqd including the termination of wires.(RJ45) | | 7 | No |
|---|
| 65 | 9.1 | Supply, installation, testing and commissioning of TV outlet mounted on a GI outlet box with front plate and all necessary accessories of wires.complete as required including the termination of wires. | | 2 | No |
|---|
| 66 | 9.11 | Supply, installation, testing and commissioning of Audio Video Connector outlet mounted on a GI outlet box with front plate and all necessary accessories of wires.complete as required including the termination of wires. | | 1 | No |
|---|
| 67 | 9.12 | Supply, installation, testing and commissioning of 4-WAY SPLITTER lockable 16 gauge sheet steel enclosure with all necessary accessories complete as required including the termination of wires. | | 1 | No |
|---|
| 68 | 9.13 | Supply, installation, testing and commissioning of 6-WAY SPLITTER lockable 16 gauge sheet steel enclosure with all necessary accessories complete as required including the termination of wires. | | 1 | No |
|---|
| 69 | 9.14 | Supply and installation, testing and commissioning 20 pair mdf make telephone tag block in lockable 16 gauge sheet steel enclosure complete as required. | | 1 | No |
|---|
| 70 | 9.15 | Supply, installation of Cat 6 Keystone UTP Jack information outlet with 1 meter Patch Chord & Dust Cover-White | | 7 | Nos |
|---|
| 71 | 9.16 | Supply , installation of 19-inch, 12U 600mm deep Equipment Rack with standardized (EIA 310-D, IEC 60297 and DIN 41494 SC48D) frame or enclosure for mounting multiple patch panels, network switches, shall have Lockable doors, with proper ventilated and open able doors from all sides, with casters and with cooling fans as above complete with necessary mounting hardware & accesories. | | 1 | Nos |
|---|
| 72 | 9.17 | Sitc Of Following sizes annealed copper 0.5sqmm telephone armoured jelly filled cabels and telephone tag blocks in sheet steel metal enclosure to be laid on either on exsiting cable tray or on ceiling etc | | 1 | Rm |
|---|
| 73 | 9.18 | 10 pair telephone cable | | 10 | Rm |
|---|
| 74 | 10 | FIRE ALARM SYSTEM (Make: System Sensor,SHRACK, BOSCH,Apollo) | | | |
|---|
| 75 | 10.01 | Supply, Installation , Testing & Commissioning of Vds approved Addressable type Multicriteria detector with VDS approved Base for use as heat or smoke or combined both with automatic electronic addressing ( Smoke + Heat + RoR), 8-bit microprocessor type and must have integrated short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each detector). The detector shall have IP 44 protection catagory & ambient temperature -20°C to + 60°C. Detector should be individually programmbale for Smoke or Heat or Multicriteria for various temperature and smoke levels as per EN-54 standards with time based scheduling The quoted item shall completely comply to the technical specification | | 9 | Nos |
|---|
| 76 | 10.02 | Supply, Installation , Testing & Commissioning of Vds approved Analogue Addressable Control module with IP66 casing containing One relay outputs and 2 Monitored Input, Relay containing a potential-free DPDT contact with a fail-safe and in-built short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each Control Module). The ambient temperature range shall be -20°C to +60°C. The quoted item shall completely comply to the technical specification. | | 6 | Nos |
|---|
| 77 | 10.03 | Supply, Installation , Testing & Commissioning of Vds /approved Addressable Loop Powered multi tone sounder with integrated short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each loop powered sounder) & having operating temperature -10°C to + 55°C | | 2 | Nos |
|---|
| 78 | 10.04 | Supply, Installation , Testing & Commissioning of Vds approved Addressable manual call point which is used for manually trigger a fire alarm suitable for interconnecting to the loop technology directly. This must have inbuilt short circuit isolator, (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each MCP). The ambient temperature range shall be -20°C to +50°C. The quoted item shall completely comply to the technical specification. | | 2 | Nos |
|---|
| 79 | 10.05 | supply,Installation, Testing & commisionong of Response Indicator with Highly-visible LED indicators (Full compliance with the latest standards is essential) | | 6 | Nos |
|---|
| 80 | 10.06 | Supply, Installation , Testing & Commissioning of Vds approved 32 bit microprocessor based TCP/IP, Intelligent Addressable Fire Alarm Control panel with 1 loop standalone with battery back up for minimum 24 hours. , The control panel, batteries, battery charger etc, shall be Vds approved and as per EN-54 standard . The panel shall consisting with minimum 240 character LCD display. ,batteries, red color housing/cabinet. Panel should be able to record atleast 10000 events history. Each loop should be capable to have atleast 250 elements / addresses out of which min. 200 nos. shall be detectors. | | 1 | Nos |
|---|
| 81 | 10.07 | Supply,Installation, Testing & Comminissionig of 2c 1.5mm2, 1100V copper conductor, PVC insulated and sheilded armoured and overall FRLS PVC sheathed cable for fire Alarm system. Cable shall be cleated to wall, ceiling. (Red Coloured) confirming to IS standards and specifications. | | 200 | Rm |
|---|
| 82 | 10.08 | Miscellaneous Accessories.(lot) CONNECTIVITY OF EXISTING BUILDING TO BUNKER | | 1 | Nos |
|---|
| 83 | 11 | CCTV SURVIELLANCE SYSTEM | | | |
|---|
| 84 | 11.01 | Supply, Storing & Fixing IP based 1/3\" CCD colour High resolution fixed and Auto Iris indoor- fixed dome fixed lens Camera activity and motion dual based programmable to be connected to DVR to be used.\n\nHorizontal Resolution 480 T.V. Lines\nSensitivity-1.0 lux / F = 1.2\nS/N ratio - Over 48 DB\nIR- fixed lens 3.6mm\nPower Supply-A.C.\nOperating Temp. 40°C to + 50 °C\n | | 4 | Nos |
|---|
| 85 | 11.02 | Supply, Storing, fixing & testing of 16 channel Network Video Recorder (NVR) and Transmission Speed 10/100/1000 Based and with all necessary adapters, plug cables, converters and required accessories -with following features.\n\nReal time recording-16fps., Video format PAL / NTSC, Video Compression- H. 264 format\nHard disk should be sufficient for 15 days recording at 165fps/ 1 cif. Vendors have to provide the Calculation Sheet for the HDD for DVR. Minimum 1 TB HDD Should be considered.\n\"? 16-Channel real-time H.264 recording\n? View and record video in CIF, 2CIF, or 4CIF/D1\nresolution\n? Supports VGA 16:9, 16:10 and 4:3 aspect ratios in\nvarious resolutions\n? Control Center software for simplified management\nof remote recorders\n? Built-in web viewer for remote viewing, playback,\ncontrol, and configuration\n? Live display support on mobile devices\n? Smart Search\n? Third-party Pan/Tilt/Zoom camera control\"\nThis should also contain the Licenses required for viewing & controlling the Cameras from the NVR & from the IP too. Minimum 10 users must be able to Log in to the System, PoN Port 6, USB Port YES, Remote Upgrade YES, Max Power per Pon Port 300mA | | 1 | Nos |
|---|
| 86 | 11.03 | Supply, Storing, fixing & testing of 12V DC 2.5 Amps. Power supply unit with Battery backup. | | 4 | Nos |
|---|
| 87 | 11.04 | Supply, Storing & Fixing of following sizes monitor\n22\" LCD Monitor | | 1 | Nos |
|---|
| 88 | 11.05 | Supply, Storing, fixing of DVR Rack suitable for DVR and audio amplifier (MAKE -LOCAL ) | | 1 | Nos |
|---|
| 89 | 11.06 | Supply, installing & testing Software for viewing and Recording with minimum 1 users license | | 1 | Nos |
|---|
| 90 | 11.07 | Network Video Recorder Server with 1 TB Hard Disk | | 1 | Nos |
|---|
| 91 | 11.08 | Supply & Laying of 3+1 shielded power and co-axial pair cable in 25mm dia PVC MMS Conduit - cost of conduit to be included. | | 200 | Rmt |
|---|
| 92 | 11.09 | Supply and laying of RG 6 Co- axial armoured video cable in 25mm dia PVC MMS Conduit - cost of conduit to be included. | | 30 | Rmt |
|---|
| 93 | 11.1 | Supply and laying of CAT 5 cable 0.5mm sqmm tinned copper wire in 25mm dia PVC MMS Conduit - cost of conduit to be included. | | 30 | Rmt |
|---|