Special Repair To Bldg No Klp-134 And Klp-135 Faculty Of Gunnery School Of Arty , Deolali Under The Aor Of Ge Deolali .
Tender Value
12.20 Lakhs
Estimated cost
Bid Submission
27 Sep 2019
0 days left
EMD
24400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Deolali → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Special Repair To Bldg No Klp-134 And Klp-135 Faculty Of Gunnery School Of Arty , Deolali Under The Aor Of Ge Deolali .
BOQ
| Name of Work: SPL REPAIR TO BLDG NO KLP-134 &KLP-135 FACULTY OF GUNNERY SCHOOL OF ARTY, DEOLALI UNDER THE AOR OF GE DEOLALI | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Taking down frame with shutters area exc 1.5 Sqm but not exc 4.00 sqm without taking off shutter from frame etc complete all as specified and directed. | 12 | Each | |
| 2 | 2 | Dismantling hearth or wall tiling of any description, size and thickness including cement mortor bedding (but not backing), removing rubbish off the premises etc complete all as specified and directed. | 360 | Sqm | |
| 3 | 3 | Taking down cement plaster on brick masonry walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. | 50 | Sqm | |
| 4 | 4 | Dismantling of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed. | 2 | Cum | |
| 5 | 5 | Demolition of plain cement concrete unreinforced in ground floor and paving above or below any thickness etc complete all as specified and directed. | 36 | Cum | |
| 6 | 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided for and fixed in any position etc complete all as directed. | 3 | Qtl | |
| 7 | 7 | Dismantling of asbestos cement sheet (corrugated,sem icorrugated) as in roof coverings etc complete all as specified and directed. | 360 | Sqm | |
| 8 | 8 | M&L for brickwork with flyash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 etc complete all as specified and directed. | 2 | Cum | |
| 9 | 9 | M&L for granite 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like with and including 15mm bedding in CM 1:6 and pointing in white cement (1:2) using marble dust with admixture of pigment to match the colour of tiles etc complete all as specified and directed. | 7 | Sqm | |
| 10 | 10 | Extra over Granite or marble slabs as in rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as specified and directed. | 10 | RM | |
| 11 | 11 | S&F coloured powder coated (50 micron) aluminium sections any type for doors, frames including joining cleat for fixing etc. complete all as specified and directed. | 200 | Kg | |
| 12 | 12 | S&F coloured powder coated (50 micron) aluminium door shutters with sections weighing not less than 1.00 kg/Rm including necessary joining cleats, glazing clips, ruber neoprene packing, handles 1Nos and roller bearings 02 Nos in each shutter, etc. complete all as specified and directed. | 2 | Sqm | |
| 13 | 13 | Supplying & fixing Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specifiedt and fixed to steel purlins with galvanised Self Driven Self Tapping screws of required lenght all as per manufacturers instructions etc complete all as specified and directed.\n | 320 | Sqm | |
| 14 | 14 | S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed. | 40 | Sqm | |
| 15 | 15 | M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate ) as in subase finished to receive floor treatment etc complete all as specified and directed. | 360 | Sqm | |
| 16 | 16 | M & L for 15 mm thick rendering in CM 1:6 on brick/ concrete surfaces and finishing the surfaces even and smooth with a thin layer of sagol etc complete all as specified and directed. | 30 | Sqm | |
| 17 | 17 | M&L for 15 mm thick rendering in CM 1:4 on brick/concrete external surfaces of walls sand faced sponge faced finish etc complete all as specified and directed. \n | 20 | Sqm | |
| 18 | 18 | M&L for complete removal of old treated surfaces on walls and applying 2mm thick white cement putty, one coat of alkali resistant primer and finally applying two coats of oil emulsion distemper etc complete all as specified and directed. | 55 | Sqm | |
| 19 | 19 | M&L for preparation of newly plastered surfaces of walls and applying one coat of alkali resistant primer over a coat of 2mm thick white cement putty,sanding the surfaces till smooth finish is obtained and finally applying two coats of oil emulsion distemper etc complete all as specified and directed. | 30 | Sqm | |
| 20 | 20 | M&L for preparing surfaces with wall care putty and applying two coats of weather proof paint (epoxy) ovaer a coat of primer complete all as specified and directed | 120 | SQM | |
| 21 | 21 | S & F 5.50 mm thick sheet tinted glass fixed in shutters etc complete all as specified and directed. | 145 | Sqm | |
| 22 | 22 | M & L for preparation of new steel surfaces exc 10 cm width/girth and applying two coats of synthethic enamel paint over a coat of primer etc complete all as specified and directed. | 50 | Sqm | |
| 23 | 23 | Taking down rolling shutters & Refixing after carrying out minor repairs and refixing steel rolling shutters including top cover anchoring rod hasp and staple and one shop coat of primer erected in position as indicated complete push pull or manual type complete all as specified and directed. | 230 | Sqm | |
| 24 | 24 | Dismantling of wall and ceiling boards of any description size any thickness including cover fillets etc complete all as specified and directed. | 210 | Sqm | |
| 25 | 25 | M&L for suspended false ceiling system using metallic (E grid)exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length)with and including 4mm thick HPSC(High pressure steam cured) pre-primed , self embossed . textured designer board, water resistant termite resistant , fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture complete all as specified and directed. Make :- EVEREST or other equivalent as approved. | 210 | Sqm | |
| 26 | 26 | S&F MS work as in Wind ties for roof includin and securing bolts and similar work conforming to Fe-290-Gde E 165 | 100 | kg | |
| 27 | 27 | S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to a common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates or is running rail conforming to FE-410-W(Gde E-250 alll as directed. | 200 | Kg | |
| 28 | 28 | M&L 15 mm thick in CM 1:6 screed bed or bedding layer of mortar for laying floor finishes etc complete all specified and directed. | 360 | Sqm | |
| 29 | 29 | M&L rubber moulded chequered cement concrete tiles in mixture of grey and white cement in equal proportion with pigment of size 300 x300 x20mm thick,set and jointed in neat cement slurry and pointed in coloured cment to match the colour of tile as in floors etc complete all as specified and as directed. | 150 | Sqm | |
| 30 | 30 | M&L Virified Ceramic tiles 10 mmthick (square/ rectangularpolished, area of each tilesnot exceeding 0.36 sqm butnot exceeding 0.42 sqm, infloors etc. set and jointed in neat cement slurry andpointed in white or colouredcement to match dark shade double charged complete all as specified and directed. | 210 | Sqm | |
| 31 | 31 | Taking down unserviceable carefully copper/aluminium point wiring (light, fan, socket or power) complete with teak wood battens including fittings such as switches, socket outlets, ceiling roses, pendent brackets, holders etc. but excluding fan regulators, tube light fittings and sketch fittings and making good disturbed surfaces of walls, floor etc.complete all as specified and directed. | 18 | Point | |
| 32 | 32 | Material and labour for point wiring with stranded copper conductor Cable PVC insulated unsheathed 1.5 Sqmm FRLS cable in and including in PVC conduit of suitable size In stone wall with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow,Tee,collers bend, PVC conduit for crossing etc. complete with PVC terminals box for mounting switches, sockets, fan regulators etc with one single core sheathed cable continuous 1.5 Sqmm,FRLS copper cable for earth wire complete all as specified and as directed for :-(a) One light point controlled by one switch with cable 1.5Sqmm Size | 12 | Point | |
| 33 | 33 | Material and labour for point wiring with stranded copper conductor Cable PVC insulated unsheathed 1.5 Sqmm FRLS cable in and including in PVC conduit of suitable size In stone wall with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow,Tee,collers bend, PVC conduit for crossing etc. complete with PVC terminals box for mounting switches, sockets, fan regulators etc with one single core sheathed cable continuous 1.5 Sqmm,FRLS copper cable for earth wire complete all as specified and as directed for :-(b) One fan point controlled by one switch with cable 1.5sqmm size | 4 | Point | |
| 34 | 34 | Material and labour for point wiring with stranded copper conductor Cable PVC insulated unsheathed 1.5 Sqmm FRLS cable in and including in PVC conduit of suitable size In stone wall with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow,Tee,collers bend, PVC conduit for crossing etc. complete with PVC terminals box for mounting switches, sockets, fan regulators etc with one single core sheathed cable continuous 1.5 Sqmm,FRLS copper cable for earth wire complete all as specified and as directed for :-(c) One 5 pin socket outlet 5 Amps on the same board. | 2 | Point | |
| 35 | 35 | Supply and fix modular switch one way 6A ,1 module complete all as specified and directed. | 18 | EACH | |
| 36 | 36 | Supply and fixing Socket 6A-2/3 pin combined 2 module complete all aspecified and directed. | 2 | EACH | |
| 37 | 37 | Supply and fixing Modular White cover plate with frame,8 Module | 1 | EACH | |
| 38 | 38 | Supply and fixing Modular Metal flush box 8 module | 1 | EACH | |
| 39 | 39 | Supply and fixing Modular White cover plate with frame,6 Module | 1 | EACH | |
| 40 | 40 | Supply and fixing Modular Metal flush box 6 module | 1 | EACH | |
| 41 | 41 | S&F OF Recess mounting 28 LED 5700K Luminaries fixtures diffused sutable for ceiling size 2'x2' feet endura make :- havells cat part no:-LHEWDRP7PK1W028 or equivalent in Philips / Bajaj. | 8 | Each | |
| 42 | 42 | M&L for cutting chases pinning in making good to facings where required and pointing in cement motor 1:3 to ends or edges of landings steps,cills sunshades,shelves,lintels,etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10cm girth in stone concrete block or slab walls complete all as specified and directed. | 11 | RM | |
| 43 | 43 | Supply and fixing Modular Fan requlator 120w With 360 degree rotational -2 module all as specified and directed | 4 | EACH | |
| 44 | 44 | S&F Sheet Metal enclosure for SPN DBs, 4 Ways, Double Door \n(IP-43), built in bus bars complete suitable for 240 Volts, AC, 50 Hz complete all as specified and as directed\nMake: L&T ( Cat No:-DBSPN004DD)/ Legrand /Havells | 2 | EACH | |
| 45 | 45 | S&F MCBs Single Pole of 240 volts 5-32 Amps,10KA Capacity, 'C' Series of Make:-Legrand,Cat No: 4085-87 to 90,92,93,94,95 or eqivalent in Siemens/L&T. | 4 | EACH | |
| 46 | 46 | S&F MCB Single pole + Neutral 240 Volts,32-63 Amps,10KA Capacity 'C' SERIES OF MAKE:Legrand,Cat No : 4086-17 to 20 or equivalent in siemens/L&T | 2 | EACH | |
| 47 | 47 | S&F Building security light fittings, with deep down aluminium housing, suitable for 20 W LED, complete pre-wired, incl suitable bracket all as specified and as directed. \n | 4 | EACH | |
| 48 | 48 | M & L for bracket made out of GI tubing 40mm dia,light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 50mm wide 5mm thick flat iron with M.S. nuts, bolts 75 mm long 12 mm dia -4 Nos & flat washer (3mm thick) 01 No. for each including preparation of steel surfaces and painting with two coats of aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete all as specified and as directed. | 4 | EACH | |
| 49 | 49 | Supply and fix ceiling rose of size 65 X 25 mm surface Bakelite three terminals complete all as specified and as directed. | 4 | EACH | |
| 50 | 50 | Supply, Laying , jointing and testing LT underground cable, heavy duty, 1100 Volts, 10Sqmm 2 Core XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed of sizes | 45 | RM | |
| 51 | 51 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed. | 5.525 | CUM | |
| 52 | 52 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed | 2.42 | CUM | |
| 53 | 53 | Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. | 3.105 | CUM | |
| 54 | 54 | M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed. | 0.25 | Per 1000 Nos | |
| 55 | 56 | Note: Amount of sch of credit of Rs. 19546.00 will be deducted from tolal amount of BOQ. |
AI Tender Summary
Tender Timeline
Sep 05, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedSep 27, 2019
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 03, 2019
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender