Design , Supply , Installation , Testing And Commissioning Of Tank Farm Management System Along With Associated Works At Raxaul Depot Under Bihar State Office, Raxaul Depot-Bihar

Indian Oil Corporation Limited-IOCL has published Design , Supply , Installation , Testing And Commissioning Of Tank Farm Management System Along With Associated Works At Raxaul Depot Under Bihar State Office. Submission Date for this Tender is 30-09-2019. Application Software Tenders in Raxaul Depot Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

21678353
Design , Supply , Installation , Testing And Commissioning Of Tank Farm Management System Along With Associated Works At Raxaul Depot Under Bihar State Office
Open Tender
Indian
Bihar
Raxaul Depot
30-09-2019

Tender Details

design , supply , installation , testing and commissioning of tank farm management system along with associated works at raxaul depot under bihar state office

Key Value

Document Fees
Refer document
EMD
INR 780592.0 /-
Tender Value
INR 7.80 Crore /-

BOQ Items

Name of Work: Design, Supply, Installation, Testing & Commissioning of Tank Farm Management System along with associated works at Raxaul Depot under Bihar State Office
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply Part BI01010001010000000000000515BI0100001112
2 2 Tank Farm Management System BI01010001010000000000000515BI0100001113
3 3 Supply of minimum SIL 2 certified Non - contact type Radar level gauges with instrument accuracy of +/- 1 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) BI01010001010000000000000515BI0100001114
4 4 For Cone Roof Vertical tanks (Primary and Secondary Radar Gauges) BI01010001010000000000000515BI0100001115 14 EA
5 5 For Internal Floating Roof Vertical tanks (Primary and Secondary Radar Gauges -) BI01010001010000000000000515BI0100001116 6 EA
6 6 For underground horizontal product tanks (Ethanol - 2 nos) BI01010001010000000000000515BI0100001117 2 EA
7 7 Supply of Non-contact type Radar level gauges with instrument accuracy of +/-3 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) BI01010001010000000000000515BI0100001118
8 8 For Water Tanks (4 nos.) BI01010001010000000000000515BI0100001119 4 EA
9 9 Supply of multi point temperature averaging sensor with integrated water interface probe (MSTW) along with mounting accessories etc complete as per specification and tender document. BI01010001010000000000000515BI0100001120
10 10 With minimum 8 elements temperature sensor (for above ground tanks - MS, HSD, Ethanol) BI01010001010000000000000515BI0100001121 10 EA
11 11 With minimum 2 elements temperature sensor (for U/G horizontal tanks - 2 nos.) BI01010001010000000000000515BI0100001122 2 EA
12 12 Supply of Density probe along with accessories etc for density measurement of the product in product tanks complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) BI01010001010000000000000515BI0100001123
13 13 For A/G Tanks with 3 elements BI01010001010000000000000515BI0100001124 10 EA
14 14 For U/G Tanks with 1 elements (Ethanol -2 nos) BI01010001010000000000000515BI0100001125 2 EA
15 15 Supply of Tank Side indicator along with mounting accessories etc complete as per specification and tender document for displaying respective tank inventory data. (TSI will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) BI01010001010000000000000515BI0100001126
16 16 For Vertical Product tanks - (Primary & Secondary Radar Gauges) BI01010001010000000000000515BI0100001127 20 EA
17 17 For U/G Product tanks (2 nos) BI01010001010000000000000515BI0100001128 2 EA
18 18 For Water Tanks (4 no) BI01010001010000000000000515BI0100001129 4 EA
19 19 Supply of top mounted minimum SIL2 certified Overfill detector (vibrating fork type) of suitable probe length along with mounting accessories, spool piece of minimum 500mm, proof testing equipment, etc complete as per specification and tender document BI01010001010000000000000515BI0100001130
20 20 For Vertical Product tanks BI01010001010000000000000515BI0100001131 10 EA
21 21 For U/G Product tanks (2 nos) BI01010001010000000000000515BI0100001132 2 EA
22 22 Supply of parallel redundant Communication Interface Units (CIU) including all accessories etc for tank farm management system complete as per specification and tender document. BI01010001010000000000000515BI0100001133
23 23 For Primary Radar gauges installed on A/G product tanks, under ground product tank, water tank & Sludge tank BI01010001010000000000000515BI0100001134 1 EA
24 24 For Secondary Radar Gauges installed on A/G product tanks BI01010001010000000000000515BI0100001135 1 EA
25 25 Supply of TFMS Server(Redundant Type) (Rack type mountable in 19" rack ) along with 1 no. rack type (1U) LED monitor of minimum size of 18.5" suitable for 24x7 operation, keyboard drawer, optical mouse, Licensed OS (latest supported by TFMS software), Licensed Antivirus, Licensed latest MS Office professional, TFMS licensed software from Radar Gauge OEM etc complete as per specification and tender document. BI01010001010000000000000515BI0100001136 2 EA
26 26 Supply of TFMS Workstation with minimum 23" LED colour monitor, standard keyboard, mouse, Licensed OS(latest supported by TFMS software), Licensed Antivirus, Licensed latest MS Office professional, TFMS licensed client software from same Radar Gauge OEM etc complete as per specification and tender document. BI01010001010000000000000515BI0100001137
27 27 19" Rack type at Control Room, form factor - Rack, CPU height - 2U BI01010001010000000000000515BI0100001138 1 EA
28 28 Tower type at TM's room BI01010001010000000000000515BI0100001139 1 EA
29 29 Push Buttons Outside Dyke Walls BI01010001010000000000000515BI0100001140
30 30 Supply of Exd/FLP Local Push button station cum indication lamp out side tank farm dyke wall for remote opening and closing of ROSOVs from LPBS, along with FLP double compression gland, TBs, mounting structure, accessories etc complete as per specifications and tender document. BI01010001010000000000000515BI0100001141
31 31 For ROSOVs (A/G product tank's inlet & outlet line- 20 nos. ) BI01010001010000000000000515BI0100001142 20 EA
32 32 Supply of Exd/FLP Local Push button station cum indication lamp out side tank farm dyke wall for remote opening and closing of ROSOVs from LPBS, along with FLP double compression gland, TBs, mounting structure, accessories etc complete as per specifications and tender document. BI01010001010000000000000515BI0100001143
33 33 S/F of FLP Push Button for DBBVs BI01010001010000000000000515BI0100001144 20 EA
34 34 Control Room equipments BI01010001010000000000000515BI0100001145
35 35 Supply of Redundant SIL 3 TUV/ EXIDA certified Safety PLC along with PLC Panels, Marshalling Panels, Biometric fingerprint cum contactless smart card reader with accessories, limit switches, Dual redundant Input Output modules, Power supply units, Relays with base, barriers, TBs, Dual Ethernet ports per processor, Serial Interface Modules, HMI , wirings, glands, plugs, other modules/ hardware required for interfacing all the required field and control room equipments including spare requirements, licenses, tags, GUI, licensed OPC compliant software etc complete as per specification and tender document.\nNote: The offered safety PLC shall be of the same make family of the integrated Distributed Control System. BI01010001010000000000000515BI0100001146 1 SET
36 36 Supply of Complete Terminal Automation Software along with required licences, dongle/keys, GUI, SCADA etc meeting the complete functional and technical requirements of the tender document. \nVendor to provide required software, licences, dongle/keys, GUI, SCADA etc for TAS Management Server, Distributed Control System, Operator work stations, fire fighting OIC, Alarm display and annunciation OIC, Engineering Work Stations(for safety PLC & DCS), Web Server, OPC Server, Historian Server / work station, any other devices connected to Control & Management LAN of the integrated Distributed Control System complete as per specification and tender document.\nTAS software shall be interfaced with following but not limited to major sub-systems / equipments alongwith GUI development for monitoring, logging, reporting, controls & interlocks etc as per specification and tender document.\n- Safety PLC\n- TAS- Management Server\n- TLF Automation System (TT reporting, registration & entry system, TT Queuing, FAN generation, Bay allocation, Additive Dosing system, Ethanol blending System, Interface with TLF equipments like BCU, MFM, Barrier Gates, Bay Queue Display, Bay allocation Display, Invoice generated display, rack monitors, Proximity card readers etc)\n-Tank Wagon loading Automation system\n-Tank Wagon unloading Automation system\n-Tank Lorry Decantation System\n-TT calibration System\n-Bio Diesel Blending system BI01010001010000000000000515BI0100001147 1 LS
37 37 Supply of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, terminal blocks and wiring etc complete as per specification and tender document for mounting of below mentioned equipments. BI01010001010000000000000515BI0100001148
38 38 For mounting of TFMS Server along with associated rack mounted monitors, rack mounted keyboard, mouse, power adapters, networking & OFC components, CIUs MCBs etc as per specification and tender document. BI01010001010000000000000515BI0100001149 1 EA
39 39 For mounting of Rack mounted Master Control Stations for MOVs & DBBVs along with power adaptors, MCBs, required accessories etc as per specification and tender document. BI01010001010000000000000515BI0100001150 1 EA
40 40 Supply of Operator Interface Console Computer (OIC) minimum 23" colour LED monitor, standard keyboard, mouse, software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. BI01010001010000000000000515BI0100001151
41 41 19" Rack type at Control Room, form factor - Rack, CPU height - 2U BI01010001010000000000000515BI0100001152 2 EA
42 42 Tower mounted type in TM's Cabin BI01010001010000000000000515BI0100001153 1 EA
43 43 Supply of Engineering Workstation (EWS) with minimum 23" colour LED monitor, standard keyboard, mouse, PLC & DCS software, HMI software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. (Locations: 1 no. in CR for both DCS and Safety PLC) - 19" Rack type at Control Room, form factor - Rack, CPU height - 2U BI01010001010000000000000515BI0100001154 1 EA
44 44 Supply of 24 ports Layer 3 Managed Ethernet Switches (10/100/1000 MBPS) with SFP, copper, fibre modules/ports along with accessories for connecting Plant management LAN equipments like CCTV System, TAS - MS Server/ Redundant OPC server, TFMS Server, TFMS work station, OICs, IOCL intranet for SAP connectivity through fire wall, Network printers, Access Control Server, Web Server Access over IOCL Intranet, connecting to OIC/ work stations etc which needs to be connected to both Plant Management LAN and Plant Control LAN for getting the entire GUIs of Complete Terminal Automation System and any other third party devices which needs OPC for interfacing with DCS etc.\nNote: \n1. Ethernet Switches to be configured in Dual Redundant mode.\n2. OFC ports to be provided for connecting interbuilding LANs and any other equipment which are to be connected to above switch and the communication is through OFC cable. BI01010001010000000000000515BI0100001155 2 EA
45 45 Supply of 24 ports Layer 2 Managed Ethernet Switches (10/100/1000 MBPS) along with SFP, copper, fibre modules, accessories for connecting equipments installed in Plant Control LAN like TAS- MS Servers, OICs, TTES, EWS, OPC Servers, Fire fighting OICs, Alarm Display OIC, DCS, Safety PLC, inter connecting building work stations etc as per system architecture and design requirement complete as per specification and tender document.\nNote:\n1. The switches are to be configured in Dual Redundant mode.\n2. OFC ports to be provided for connecting interbuilding LANs, and any other equipment which are to be connected to above switch and the communication is through OFC cable. BI01010001010000000000000515BI0100001156 2 EA
46 46 Supply of Wall mounted Network Rack-minimum 15U 19" Rack for mounting of Terminal Server/Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at Security Room, TM room, Invoice Room, S&D for TAS equipments BI01010001010000000000000515BI0100001157 2 EA
47 47 UPS: Supply & Installation of appropriate capacity of UPS based on actual\r\nload calculation plus 20% spare or 20 kVA, whichever is greater Indoor type\r\nSuitable for input 3phase, 415Volts and out-put 220V A.C.,\r\n1-Ph, 50 Hz, and 3-phase N 415 Volts A.C. UPS with Parallel Redundant system with bypass Transformer, A.C. Distribution Board, VRLA SMF\r\nBattery Bank for both Inverter system [with 30 min battery\r\nback-up] and accessories in accordance with this\r\nrequisition, and UPS SLD attached. Complete as per\r\nspecifications / tender documents. BI01010001010000000000000515BI0100001158 1 SET
48 48 Supply of UPS Power Distribution Panel along with Biometric fingerprint cum contactless smart card reader with accessories for powering DCS Panel, Safety PLC Panel, TAS-MS, OIC, EWS, TFMS System, TTES, printers, Bay Instruments other control room equipments, Tank Farm Instruments, CCTV system, Fire Detection System, Access control system, Bay Queue Display boards, other display boards, ROSOV ESD port, header line instruments and any other TAS equipments where UPS power are required for smooth un-interrupted operation. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation, MCB etc are to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring with digital voltmeter & digital ammeter separately for UPS and Auxilliary supply etc as per specifications and tender document.\nNote: Minimum 20% spare power points to be made available for future use. BI01010001010000000000000515BI0100001159 1 LS
49 49 Supply of IP based Redundant GSM modem suitable for 24x7 operation along with accessories for auto SMS as per specification and tender document. BI01010001010000000000000515BI0100001160 1 Set
50 50 Supply of minimum 42" HD LED monitor along with 1 no. of hooter, ACK push button, mounting accessories, cables etc for critical alarms display & annunciation complete as per specifications and tender document. BI01010001010000000000000515BI0100001161 1 EA
51 51 CABLING,JB,EARTHING BI01010001010000000000000515BI0100001162
52 52 Note: Supply of cables shall be along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners , OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), LAN face plates, conduits, structural steel for mounting of equipments, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc BI01010001010000000000000515BI0100001163
53 53 Supply of FRLS Armoured Copper Power cable as per tender specifications. BI01010001010000000000000515BI0100001164
54 54 3C x 2.5 sqmm BI01010001010000000000000515BI0100001165 1500 RM
55 55 12C x 2.5 sqmm BI01010001010000000000000515BI0100001166 200 RM
56 56 24C x 2.5 sqmm BI01010001010000000000000515BI0100001167 800 RM
57 57 Supply of FRLS Armoured Copper Control cable as per tender specifications. BI01010001010000000000000515BI0100001168
58 58 2C x 1.5 sqmm BI01010001010000000000000515BI0100001169 1500 RM
59 59 4C x 1.5 sqmm BI01010001010000000000000515BI0100001170 500 RM
60 60 8C x 1.5 sqmm BI01010001010000000000000515BI0100001171 50 RM
61 61 10C x 1.5 sqmm BI01010001010000000000000515BI0100001172 50 RM
62 62 12C x 1.5 sqmm BI01010001010000000000000515BI0100001173 50 RM
63 63 16C x 1.5 sqmm BI01010001010000000000000515BI0100001174 50 RM
64 64 18C x 1.5 sqmm BI01010001010000000000000515BI0100001175 50 RM
65 65 20C x 1.5 sqmm BI01010001010000000000000515BI0100001176 50 RM
66 66 24C x 1.5 sqmm BI01010001010000000000000515BI0100001177 800 RM
67 67 32C x 1.5 sqmm BI01010001010000000000000515BI0100001178 50 RM
68 68 36C x 1.5 sqmm BI01010001010000000000000515BI0100001179 50 RM
69 69 48C x 1.5 sqmm BI01010001010000000000000515BI0100001180 500 RM
70 70 Supply of FRLS Armoured Copper Signal cable as per tender specifications. BI01010001010000000000000515BI0100001181
71 71 1P x 1.5 sqmm BI01010001010000000000000515BI0100001182 1500 RM
72 72 2P x 1.5 sqmm BI01010001010000000000000515BI0100001183 1500 RM
73 73 3P x 1.5 sqmm BI01010001010000000000000515BI0100001184 50 RM
74 74 4P x 1.5 sqmm BI01010001010000000000000515BI0100001185 500 RM
75 75 6P x 1.5 sqmm BI01010001010000000000000515BI0100001186 50 RM
76 76 12P x 1.5 sqmm BI01010001010000000000000515BI0100001187 500 RM
77 77 Supply of FS Armoured Copper Power cable as per tender specifications. BI01010001010000000000000515BI0100001188
78 78 3C x 2.5 sqmm BI01010001010000000000000515BI0100001189 500 RM
79 79 Supply of FS Armoured Copper Control cable as per tender specifications. BI01010001010000000000000515BI0100001190
80 80 2C x 1.5 sqmm BI01010001010000000000000515BI0100001191 500 RM
81 81 4C x 1.5 sqmm BI01010001010000000000000515BI0100001192 500 RM
82 82 6C x 1.5 sqmm BI01010001010000000000000515BI0100001193 50 RM
83 83 8C x 1.5 sqmm BI01010001010000000000000515BI0100001194 50 RM
84 84 10C x 1.5 sqmm BI01010001010000000000000515BI0100001195 50 RM
85 85 12C x 1.5 sqmm BI01010001010000000000000515BI0100001196 50 RM
86 86 Supply of FS Armoured Copper Signal cable as per tender specifications. BI01010001010000000000000515BI0100001197
87 87 1P x 1.5 sqmm BI01010001010000000000000515BI0100001198 500 RM
88 88 2P x 1.5 sqmm BI01010001010000000000000515BI0100001199 500 RM
89 89 3P x 1.5 sqmm BI01010001010000000000000515BI0100001200 50 RM
90 90 4P x 1.5 sqmm BI01010001010000000000000515BI0100001201 50 RM
91 91 Supply of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents. BI01010001010000000000000515BI0100001202
92 92 50mm BI01010001010000000000000515BI0100001203 500 RM
93 93 100 mm BI01010001010000000000000515BI0100001204 500 RM
94 94 150 mm BI01010001010000000000000515BI0100001205 2000 RM
95 95 300 mm BI01010001010000000000000515BI0100001206 500 RM
96 96 600 mm BI01010001010000000000000515BI0100001207 50 RM
97 97 Supply of Exd/FLP Junction Box (Power/Control/Signal JB) with IP 65 as per specification suitable for hazardous area of zone 1, group IIA/IIB, T3 or better having CCOE/CMRI approval. It shall be complete in all respect. Accessories like certified double compression cable glands with PVC shrouds & plugs for excess entries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners. Complete as per specification / tender documents. BI01010001010000000000000515BI0100001208
98 98 24 ways JB BI01010001010000000000000515BI0100001209 4 EA
99 99 18 ways JB BI01010001010000000000000515BI0100001210 4 EA
100 100 12 ways JB BI01010001010000000000000515BI0100001211 4 EA
101 101 8 ways JB BI01010001010000000000000515BI0100001212 4 EA
102 102 6 ways JB BI01010001010000000000000515BI0100001213 4 EA
103 103 4 ways JB BI01010001010000000000000515BI0100001214 4 EA
104 104 Supply of 50 mm HDPE pipe of minimum 2.5 mm thick along with accessories as per tender specifications and instructions of Engineer in charge. BI01010001010000000000000515BI0100001215 1000 RM
105 105 Supply of 1C x 6 Sq. mm FRLS Flexible copper insulated green wire for earthing instruments and junction boxes etc complete as per specification and tender document BI01010001010000000000000515BI0100001216 1000 RM
106 106 Supply of GI strip ( 50mm X 6mm) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories required for complete Terminal Automation System as per Standard Design Engineering, specification and tender document. BI01010001010000000000000515BI0100001217 1500 RM
107 107 Supply of GI strip ( 25mm X 3mm) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories required for complete Terminal Automation System as per Standard Design Engineering, specification and tender document. BI01010001010000000000000515BI0100001218 1000 RM
108 108 Earth Pit BI01010001010000000000000515BI0100001219
109 109 Supply of Maintenance Free CPRI approved Earth pit ( Ashlok /Equivalent make ) as per IS : 3043 with 100 mm dia of minimum 3mtr length T45 model/equivalent safe earthing electrode with Pipe-in-pipe technology consisting of two mild steel pipes one inside the other, hot dip galvanized (80-100 microns), filled with high conductive & corrosion resistance crystalline mixture and backfilling compound around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Procedure recommended by chemical earth supplier and IS code to be finally adopted. Item also includes provision of earth station flags with pit nos and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation \nAll Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification) BI01010001010000000000000515BI0100001220
110 110 Tank dyke BI01010001010000000000000515BI0100001221 4 EA
111 111 Supply of 50 mm HDPE pipe of minimum 2.5 mm thick along with accessories as per tender specifications and instructions of Engineer in charge. BI01010001010000000000000515BI0100001222 500 RM
112 112 Supply of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc BI01010001010000000000000515BI0100001223 2 MT
113 113 Supply of hot dip galvanised Structural steel (MS) including civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc required for complete Terminal Automation System BI01010001010000000000000515BI0100001224 1 MT
114 114 Hydrocarbon Detection system BI01010001010000000000000515BI0100001225
115 115 Supply of Flameproof cum weather proof (IP 66 or better) min SIL 2 certified Hydrocarbon vapour detectors along with calibration kit, accessories and structural supports, canopy/sunshade etc as per specification and tender document. BI01010001010000000000000515BI0100001226
116 116 Point type Infrared detector\n(Indicative location: Each tank dyke sump pit inside dyke wall - 4 nos., Near ROSOVs of MS tanks- 2 nos., TLF and TW MS & Ethanol pump seal - 3 nos., Pump house drain pit - 1 no.; BI01010001010000000000000515BI0100001227 10 EA
117 117 Open path type Infrared detector (0-40m) along with alignment telescope, configuration & Testing kit etc (Tentative location: MS tanks covering ROSOVs -3 nos.; ) BI01010001010000000000000515BI0100001228 3 EA
118 118 Supply of weather proof and Explosion proof Hooter cum beacons/ flash light along with accessories and structural supports as per specification. ( Tentative location : Each product tank dyke-2 nos., Near Pump House - 1 no..) BI01010001010000000000000515BI0100001229 3 EA
119 119 Supply of one no. of Portable Hydrocarbon vapour detector along with accessories complete as per specification and tender document. BI01010001010000000000000515BI0100001230 1 EA
120 120 INSTALLATION OF EQUIPMENTS- BI01010001010000000000000515BI0100001231
121 121 Installation, Integration, Testing and Commissioning of minimum SIL 2 certified Non - contact type Radar level gauges with instrument accuracy of +/- 1 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) BI01010001010000000000000515BI0100001232
122 122 For Cone Roof Vertical tanks (Primary and Secondary Radar Gauges - HSD-3x2) BI01010001010000000000000515BI0100001233 14 EA
123 123 For Internal Floating Roof Vertical tanks (Primary and Secondary Radar Gauges - MS-3x2, Ethanol - 2x2) BI01010001010000000000000515BI0100001234 6 EA
124 124 For underground horizontal product tanks (Ethanol - 2 nos) BI01010001010000000000000515BI0100001235 2 EA
125 125 Installation, Integration, Testing and Commissioning of Non- Contact type Radar level gauges with instrument accuracy of +/-3 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) BI01010001010000000000000515BI0100001236
126 126 For Water Tanks (4 no) BI01010001010000000000000515BI0100001237 4 EA
127 127 Installation, Integration, Testing and Commissioning of multi point temperature averaging sensor with integrated water interface probe (MSTW) along with mounting accessories etc complete as per specification and tender document. BI01010001010000000000000515BI0100001238
128 128 With minimum 8 elements temperature sensor (for above ground tanks - MS, HSD, Ethanol) BI01010001010000000000000515BI0100001239 10 EA
129 129 With minimum 2 elements temperature sensor (for U/G horizontal tanks - Ethanol -2 nos) BI01010001010000000000000515BI0100001240 2 EA
130 130 Installation, Integration, Testing and Commissioning of Density probe along with accessories etc for density measurement of the product complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) BI01010001010000000000000515BI0100001241
131 131 For A/G Tanks with 3 elements BI01010001010000000000000515BI0100001242 10 EA
132 132 For U/G Tanks with 1 elements ( Ethanol -2 nos) BI01010001010000000000000515BI0100001243 2 EA
133 133 Installation, Integration, Testing and Commissioning of Tank Side indicator along with mounting accessories etc complete as per specification and tender document for displaying respective tanks inventory data. (TSI will have IEC & ATEX certified minimum along with any other certification as stated else where in tender) BI01010001010000000000000515BI0100001244
134 134 For Vertical Product tanks - (Primary & Secondary Radar Gauges) BI01010001010000000000000515BI0100001245 20 EA
135 135 For U/G Product tanks BI01010001010000000000000515BI0100001246 2 EA
136 136 For Water Tanks (4 no) BI01010001010000000000000515BI0100001247 4 EA
137 137 Installation, Integration, Testing and Commissioning of top mounted minimum SIL2 certified Overfill detector (vibrating fork type) of suitable probe length along with mounting accessories, spool piece of minimum 500mm, proof testing equipment etc complete as per specification and tender document BI01010001010000000000000515BI0100001248
138 138 For Vertical Product tanks BI01010001010000000000000515BI0100001249 10 EA
139 139 For U/G Product tanks (Ethanol -2 nos) BI01010001010000000000000515BI0100001250 2 EA
140 140 Installation of Paraller Redundant Communiaction Unit(For Primary & Secondary gauge) BI01010001010000000000000515BI0100001251
141 141 Primary Gauge BI01010001010000000000000515BI0100001252 1 EA
142 142 Secondary Gauge BI01010001010000000000000515BI0100001253 1 EA
143 143 Installation, Integration, Testing and Commissioning of Exd/FLP Local Push button station cum indication lamp out side tank farm dyke wall for remote opening and closing of ROSOVs from LPBS along with FLP double compression gland, TBs, mounting structure, accessories etc complete as per specifications and tender document. BI01010001010000000000000515BI0100001254
144 144 For ROSOVs (A/G product tank's inlet, outlet and recirculation line- 10 nos.) BI01010001010000000000000515BI0100001255 20 EA
145 145 Installation, Integration, Configuration, Testing and Commissioning of TFMS Server(Redundant Type) (Rack type mountable in 19" rack ) along with 1 no. rack type (1U) LED monitor of minimum size of 18.5" suitable for 24x7 operation, keyboard drawer, optical mouse, Licensed OS (latest supported by TFMS software), Licensed Antivirus, Licensed latest MS Office professional, TFMS licensed software from Radar Gauge OEM etc complete as per specification and tender document. BI01010001010000000000000515BI0100001256 2 SET
146 146 Installation, Integration, Configuration, Testing and Commissioning of TFMS Workstation with minimum 23" LED colour monitor, standard keyboard, mouse, Licensed OS (latest supported by TFMS software), Licensed Antivirus, Licensed latest MS Office professional, TFMS licensed client software from same Radar Gauge OEM etc complete as per specification and tender document. BI01010001010000000000000515BI0100001257
147 147 19" Rack type at Control Room, form factor - Rack, CPU height - 2U BI01010001010000000000000515BI0100001258 1 EA
148 148 Tower type at TM's room BI01010001010000000000000515BI0100001259 1 EA
149 149 Design, Engineering, Installation, Setup, Configuration, Integration, Testing & Commissioning of Redundant, SIL 3 TUV/ EXIDA certified Safety PLC along with PLC Panels, Marshalling Panels, Biometric fingerprint cum contactless smart card reader with accessories, limit switches, Dual redundant Input Output modules, Power supply units, Relays with base, barriers, TBs, Redundant host communication ports, Serial Interface Modules, any other communication module, HMI, wirings, glands, plugs, other modules/ hardware required for interfacing all the required field and control room equipments including spare requirements, licenses, tags, GUI, licensed OPC compliant software etc complete as per specification and tender document.\nNote: The offered safety PLC shall be of the same make family of the integrated Distributed Control System. BI01010001010000000000000515BI0100001260 1 SET
150 150 Design, Installation, Configuration, Testing & Commissioning of Complete Terminal Automation Software along with required licences, dongle/keys, GUI, SCADA etc meeting the complete funtional and technical requirements of the tender document. \nVendor to provide required softwares, licences, dongle/keys, GUI, SCADA etc for TAS Management Server, Distributed Control System, Operator work stations, Fire Fighting OIC, Alarm display and annunciation OIC, Engineering Work Stations(for safety PLC & DCS), Web Server, OPC Server, Historian Server / work station, any other devices connected to Control & Management LAN of the integrated Distributed Control System complete as per specification and tender document. \nTAS software shall be interfaced with following but not limited to major sub-systems / equipments alongwith GUI development for monitoring, logging, reporting, controls & interlocks etc as per specification and tender document.\n- Safety PLC\n- TAS Management Server\n- TLF Automation System (TT reporting, registration & entry system, TT Queuing, FAN generation, Bay allocation, Additive Dosing system, Ethanol blending System, Interface with TLF equipments like BCU, MFM, Barrier Gates, Bay Queue Display, Bay allocation Display, Invoice generated display, rack monitors, Proximity card readers etc)\n-Tank Wagon loading Automation system\n-Tank Wagon unloading Automation system\n-Tank Lorry Decantation System\n-TT calibration System\n-Bio Diesel Blending system BI01010001010000000000000515BI0100001261 1 LS
151 151 Installation of 42 U Rack Enclosure cabinet/System cabinet with 19" rack size, along with accessories like Biometric fingerprint cum contactless smart card reader with accessories, limit switches, earthing arrangements, breaker, fuses, terminal blocks and wiring etc complete as per specification and tender document for mounting of below mentioned equipments BI01010001010000000000000515BI0100001262
152 152 For mounting of TFMS Server along with associated rack mounted monitors, rack mounted keyboard, mouse, power adapters, networking & OFC components, CIUs, MCBs etc as per specification and tender document BI01010001010000000000000515BI0100001263 1 EA
153 153 For mounting of Rack mounted Master Control Stations for MOVs & DBBVs along with power adaptors, MCBs, required accessories etc as per specification and tender document BI01010001010000000000000515BI0100001264 1 EA
154 154 Installation, Configuration, Integration, Testing and Commissioning of Operator Interface Console Computer (OIC) minimum 23" colour LED monitor, standard keyboard, mouse, software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. BI01010001010000000000000515BI0100001265
155 155 19" Rack type at Control Room, form factor - Rack, CPU height - 2U BI01010001010000000000000515BI0100001266 2 EA
156 156 Tower mounted type in TM's Cabin BI01010001010000000000000515BI0100001267 1 EA
157 157 Installation, Integration, Testing and Commissioning of Engineering Workstation (EWS) with minimum 23" colour LED monitor, standard keyboard, mouse, PLC & DCS software, HMI software, SCADA, GUI, OS, Antivirus, MS office professional etc. complete as per specifications and tender document. (Locations: 1 no. in CR for both DCS and Safety PLC) - 19" Rack type at Control Room, form factor - Rack, CPU height - 2U BI01010001010000000000000515BI0100001268 1 EA
158 158 Installation, Integration, Configuration, Testing and Commissioning of 24 ports Layer 3 Managed Ethernet Switches (10/100/1000 MBPS) with SFP, copper, fiber modules/ports along with accessories for connecting Plant management LAN equipments like CCTV System, TAS - MS Server/ Redundant OPC server, TFMS Server, TFMS work station, OICs, IOCL intranet for SAP connectivity through fire wall, Network printers, Access Control Server, Web Server Access over IOCL Intranet, connecting to OIC/ work stations etc which needs to be connected to both Plant Management LAN and Plant Control LAN for getting the entire GUIs of Complete Terminal Automation System and any other third party devices which needs OPC for interfacing with DCS etc. \nNote: \n1. Ethernet Switches to be configured in Dual Redundant mode.\n2. OFC ports to be provided for connecting interbuilding LANs and any other equipment which are to be connected to above switch and the communication is through OFC cable. BI01010001010000000000000515BI0100001269 2 EA
159 159 Installation, Integration, Configuration, Testing and Commissioning of 24 ports Layer 2 Managed Ethernet Switches (10/100/1000 MBPS) along with SFP, copper, fiber modules, accessories for connecting equipments installed in Plant Control LAN like TAS- MS Servers, OICs, TTES, EWS, OPC Servers, Fire fighting OICs, Alarm Display OIC, DCS, Safety PLC, inter connecting building work stations etc as per system architecture and design requirement complete as per specification and tender document.\nNote:\n1. The switches are to be configured in Dual Redundant mode.\n2. OFC ports to be provided for connecting interbuilding LANs, and any other equipment which are to be connected to above switch and the communication is through OFC cable. BI01010001010000000000000515BI0100001270 2 EA
160 160 Installation of Wall mounted Network Rack-minimum 15U 19" Rack for mounting of Terminal Server/Ethernet switches/LIU/ OFC components along with accessories like power sockets, MCBs, fan, mounting accessories etc complete in all respective at Security Room, TM room, Invoice Room, S&D for TAS equipments. BI01010001010000000000000515BI0100001271 2 EA
161 161 Installation, Testing and Commissioning of UPS Power Distribution Panel along with Biometric fingerprint cum contactless smart card reader with accessories for powering DCS Panel, Safety PLC Panel, TAS-MS, OIC, EWS, TFMS System, TTES, printers, Bay Instruments other control room equipments, Tank Farm Instruments, CCTV system, Fire Detection System, Access control system, Bay Queue Display boards, other display boards, ROSOV ESD port, header line instruments and any other TAS equipments where UPS power are required for smooth un-interrupted operation. Miscellaneous Instrumentation comprising of suitable MCCBs for Isolation, MCB etc are to be provided. The panel shall be complete in all respects with necessary indication lamps for powering, necessary control wiring with digital voltmeter & digital ammeter separately for UPS and Auxilliary supply etc as per specifications and tender document.\nNote: Minimum 20% spare power points to be made available for future use. BI01010001010000000000000515BI0100001272 1 LS
162 162 Installation, Integration, Configuration, Testing and Commissioning of IP based Redundant GSM modem suitable for 24x7 operation along with accessories for auto SMS as per specification and tender document. BI01010001010000000000000515BI0100001273 1 EA
163 163 Installation, Integration, Configuration, Testing and Commissioning of minimum 42" HD LED monitor along with 1 no. of hooter, ACK push button, mounting accessories, cables etc for critical alarms display and annunciation complete as per specifications and tender document. BI01010001010000000000000515BI0100001274 1 EA
164 164 Note: Laying, glanding, ferruling, termination of cables shall be along with accessories like certified double compression cable glands with PVC shrouds, plugs for excess entries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners, OFC accessories (like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, media converters etc), LAN face plates, conduits, structural steel for mounting of equipments, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules, etc BI01010001010000000000000515BI0100001275
165 165 Laying, glanding, ferruling, termination of FRLS Armoured Copper Power cable as per tender specifications. BI01010001010000000000000515BI0100001276
166 166 3C x 2.5 sqmm BI01010001010000000000000515BI0100001277 1500 RM
167 167 12C x 2.5 sqmm BI01010001010000000000000515BI0100001278 200 RM
168 168 24C x 2.5 sqmm BI01010001010000000000000515BI0100001279 800 RM
169 169 Laying, glanding, ferruling, termination of FRLS Armoured Copper Control cable as per tender specifications. BI01010001010000000000000515BI0100001280
170 170 2C x 1.5 sqmm BI01010001010000000000000515BI0100001281 1500 RM
171 171 4C x 1.5 sqmm BI01010001010000000000000515BI0100001282 500 RM
172 172 8C x 1.5 sqmm BI01010001010000000000000515BI0100001283 50 RM
173 173 10C x 1.5 sqmm BI01010001010000000000000515BI0100001284 50 RM
174 174 12C x 1.5 sqmm BI01010001010000000000000515BI0100001285 50 RM
175 175 16C x 1.5 sqmm BI01010001010000000000000515BI0100001286 50 RM
176 176 18C x 1.5 sqmm BI01010001010000000000000515BI0100001287 50 RM
177 177 20C x 1.5 sqmm BI01010001010000000000000515BI0100001288 50 RM
178 178 24C x 1.5 sqmm BI01010001010000000000000515BI0100001289 800 RM
179 179 32C x 1.5 sqmm BI01010001010000000000000515BI0100001290 50 RM
180 180 36C x 1.5 sqmm BI01010001010000000000000515BI0100001291 50 RM
181 181 48C x 1.5 sqmm BI01010001010000000000000515BI0100001292 500 RM
182 182 Laying, glanding, ferruling, termination of FRLS Armoured Copper Signal cable as per tender specifications. BI01010001010000000000000515BI0100001293
183 183 1P x 1.5 sqmm BI01010001010000000000000515BI0100001294 1500 RM
184 184 2P x 1.5 sqmm BI01010001010000000000000515BI0100001295 1500 RM
185 185 3P x 1.5 sqmm BI01010001010000000000000515BI0100001296 50 RM
186 186 4P x 1.5 sqmm BI01010001010000000000000515BI0100001297 500 RM
187 187 6P x 1.5 sqmm BI01010001010000000000000515BI0100001298 50 RM
188 188 12P x 1.5 sqmm BI01010001010000000000000515BI0100001299 500 RM
189 189 Laying, glanding, ferruling, termination of FS Armoured Copper Power cable as per tender specifications. BI01010001010000000000000515BI0100001300
190 190 3C x 2.5 sqmm BI01010001010000000000000515BI0100001301 500 RM
191 191 Laying, glanding, ferruling, termination of FS Armoured Copper Control cable as per tender specifications. BI01010001010000000000000515BI0100001302
192 192 2C x 1.5 sqmm BI01010001010000000000000515BI0100001303 500 RM
193 193 4C x 1.5 sqmm BI01010001010000000000000515BI0100001304 500 RM
194 194 6C x 1.5 sqmm BI01010001010000000000000515BI0100001305 50 RM
195 195 8C x 1.5 sqmm BI01010001010000000000000515BI0100001306 50 RM
196 196 10C x 1.5 sqmm BI01010001010000000000000515BI0100001307 50 RM
197 197 12C x 1.5 sqmm BI01010001010000000000000515BI0100001308 50 RM
198 198 Laying, glanding, ferruling, termination of FS Armoured Copper Signal cable as per tender specifications. BI01010001010000000000000515BI0100001309
199 199 1P x 1.5 sqmm BI01010001010000000000000515BI0100001310 500 RM
200 200 2P x 1.5 sqmm BI01010001010000000000000515BI0100001311 500 RM
201 201 3P x 1.5 sqmm BI01010001010000000000000515BI0100001312 50 RM
202 202 4P x 1.5 sqmm BI01010001010000000000000515BI0100001313 50 RM
203 203 Laying of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents. BI01010001010000000000000515BI0100001314
204 204 50mm BI01010001010000000000000515BI0100001315 500 RM
205 205 100 mm BI01010001010000000000000515BI0100001316 500 RM
206 206 150 mm BI01010001010000000000000515BI0100001317 2000 RM
207 207 300 mm BI01010001010000000000000515BI0100001318 500 RM
208 208 600 mm BI01010001010000000000000515BI0100001319 50 RM
209 209 Installation of Exd/FLP Junction Box (Power/Control/Signal JB) with IP 65 as per specification suitable for hazardous area of zone 1, group IIA/IIB, T3 or better having CCOE/CMRI approval. It shall be complete in all respect. Accessories like certified double compression cable glands with PVC shrouds & plugs for excess entries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners. Complete as per specification / tender documents. BI01010001010000000000000515BI0100001320
210 210 24 ways JB BI01010001010000000000000515BI0100001321 4 EA
211 211 18 ways JB BI01010001010000000000000515BI0100001322 4 EA
212 212 12 ways JB BI01010001010000000000000515BI0100001323 4 EA
213 213 8 ways JB BI01010001010000000000000515BI0100001324 4 EA
214 214 6 ways JB BI01010001010000000000000515BI0100001325 4 EA
215 215 4 ways JB BI01010001010000000000000515BI0100001326 4 EA
216 216 Laying of 50 mm HDPE pipe of minimum 2.5 mm thick along with accessories as per tender specifications and instructions of Engineer in charge. BI01010001010000000000000515BI0100001327 1000 RM
217 217 Laying, glanding, ferruling, termination of 1C x 6 Sq. mm FRLS Flexible copper insulated green wire for earthing instruments and junction boxes etc complete as per specification and tender document BI01010001010000000000000515BI0100001328 1000 RM
218 218 Fabrication, cutting, laying and connecting of GI strip ( 50mm X 6mm) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories required for complete Terminal Automation System as per Standard Design Engineering, specification and tender document. BI01010001010000000000000515BI0100001329 1500 RM
219 219 Fabrication, cutting, laying and connecting of GI strip ( 25mm X 3mm) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories required for complete Terminal Automation System as per Standard Design Engineering, specification and tender document. BI01010001010000000000000515BI0100001330 1000 RM
220 220 Installation, Testing and Commissioning of Maintenance Free CPRI approved Earth pit ( Ashlok /Equivalent make ) as per IS : 3043 with 100 mm dia of minimum 3mtr length T45 model/equivalent safe earthing electrode with Pipe-in-pipe technology consisting of two mild steel pipes one inside the other, hot dip galvanized (80-100 microns), filled with high conductive & corrosion resistance crystalline mixture and backfilling compound around electrode, 25 mm dia G.I. watering pipe with funnel, test link, brick masonry earth pit including plastering in CM 1:4, 600x600 mm C.I. Manhole chamber including providing suitable earth bus for interconnection etc. Equivalent make shall be approved by client / consultants. Procedure recommended by chemical earth supplier and IS code to be finally adopted. Item also includes provision of earth station flags with pit nos. and date of inspection and the next due date of inspection. Job also includes provision of test certificate of earthing station from a licensed electrician as per the format of the Corporation\nAll Instruments, JBs, Equipments in Field and CCR shall be earthed by 6 mm2 PVC insulated copper cable to nearest Insulated copper Earth Bus bar ( minimum size 25 mm x 6 mm ) and this earth bar shall be connected to earth pit by redundant Multi stranded copper cable (Min 25 mm2 ). Signal and Power earth shall be separate as per specification) BI01010001010000000000000515BI0100001331
221 221 Tank Dyke BI01010001010000000000000515BI0100001332 4 EA
222 222 Laying of 50 mm HDPE pipe of minimum 2.5 mm thick along with accessories as per tender specifications and instructions of Engineer in charge. BI01010001010000000000000515BI0100001333 500 RM
223 223 Design, Fabrication, erection, weld, painting, cutting, drilling, grinding etc of Structural steel (MS) for erection of cable bridge (if required) for laying of above ground cables at road crossing or any other place within the Terminal including painting, Civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc BI01010001010000000000000515BI0100001334 5 MT
224 224 Design, Fabrication, erection, weld, cutting, drilling, grinding etc of hot dip galvanised Structural steel (MS) including civil foundations, nuts, bolts, washers, cleats, stiffners, gussets, base plate etc required for complete Terminal Automation System BI01010001010000000000000515BI0100001335 1 MT
225 225 Design, development, modification, configuration, testing and commissioning of existing TAS software, DCS/PLC logic, GUI etc including any hardware modification as addition of modules, ports etc for implementation of following features after FAT (if required) or during CAMC period as stated in tender document. The job includes necessary tro-& fro travel, lodging, boarding, food etc required for implementation at site complete in all respect and as per direction of EIC. BI01010001010000000000000515BI0100001336
226 226 Product tank addition BI01010001010000000000000515BI0100001337 10 per tank
227 227 Hydrocarbon Detection system BI01010001010000000000000515BI0100001338
228 228 Installation, integration, Calibration, Testing, and Commissioning Flameproof cum weather proof (IP 66 or better) min SIL 2 certified Hydrocarbon gas detectors along with calibration kit, accessories and structural supports etc as per specification and tender document. BI01010001010000000000000515BI0100001339
229 229 Point type Infrared detector\n(Indicative location: Each tank dyke sump pit inside dyke wall - 4 nos., Near ROSOVs of MS tanks- 2 nos., TLF and TW MS & Ethanol pump seal - 3 nos., Pump house drain pit - 1 no.; BI01010001010000000000000515BI0100001340 10 EA
230 230 Open path type Infrared detector (0-40m) along with alignment telescope, configuration & Testing kit etc (Tentative location: MS tanks covering ROSOVs -3 nos.; ) BI01010001010000000000000515BI0100001341 3 EA
231 231 Supply of weather proof and Explosion proof Hooter cum beacons/ flash light along with accessories and structural supports as per specification. ( Tentative location : Each product tank dyke-2 nos., Near Pump House - 1 no..) BI01010001010000000000000515BI0100001342 3 EA
232 232 Other Miscellaneous Items BI01010001010000000000000515BI0100001343
233 233 Providing training to IOCL employee as per schedule/Module for 2 days as per tender document BI01010001010000000000000515BI0100001344 1 EA
234 234 Submission of Final Detailed system design, Engineering, Documentations, as built drawings etc complete as per tender BI01010001010000000000000515BI0100001345 1 EA
235 235 SIL verification / Validation BI01010001010000000000000515BI0100001346
236 236 SIL verification from approved third party agencies. (For SIFs as per SIL Assessment study report/detail engg). All required documentation as per specs and other documentation mentioned elsewhere in tender scope has to be submitted. Complete as per specification / tender documents. BI01010001010000000000000515BI0100001347 1 LS
237 237 Validation of entire Safety System (SIS) for SIFs (for e.g. AOPS -SIF) shall be carried out from approved third party agency prior to trial period. Automation contractor shall bear the responsibility of its co-ordination and logistics. The third party has to submit a detailed report along with certification for SIS which is to be approved by IOCL along with all other required documentation as per specification and tender documents. BI01010001010000000000000515BI0100001348 1 LS
238 238 Supply of Master Control Station BI01010001010000000000000515BI0100001349 1 EA
239 239 WBM Road, Dyke cutting, concrete breaking for cable trenches including shoring, strutting etc, if required and repairing of the road and restoration of same using PCC 1:2:4 with 20mm down stone chip, dyke to original condition and disposing off excess materials within the work site as per direction of site engineer. Breaking the existing RCC work and disposing off the malba to an unobjectionable place as per the instruction of the site engineer. Job shall be complete in all respect including the cost of all labour, tools, materials, load lift hire charges of equipments if any. BI01010001010000000000000515BI0100001350 300 M2
240 240 Sand FILLING BI01010001010000000000000515BI0100001351 100 M3
241 241 Supply, installation, testing and commissioning of cubicle type power and motor control centre with 6nos of LED type (RYB) indicating lamps, 3 Nos. of ammeters,1No.of voltmeter with selector switch, 3nos. of 100/5A CTs, control fuses, control wiring etc., and to be fabricated out of 16 SWG MS sheet undergone 7 tank process and painted with anticorrosive primer and two coats of grey enamel paint and having following specific components complete as per enclosed standard drawings: 125A FP SFCOS with 125A HRC fuse as incomer-1 No 125A TPN busbar chamber with Aluminium bus 63A TPN SDFU with 50A HRC fuse as outgoings - 4 Nos 63A 100mA RCBO (MCB+ELCB) - 3 Nos. 63A 300mA RCBO (MCB+ELCB) - 1 No. 6-32A SP MCB - 40 Nos. 10A DP MCB - 12 Nos. 25A TP MCB - 3 Nos. Dummy plates - 23 Nos. BI01010001010000000000000515BI0100001352 1 EA
242 242 Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments,pillars,posts,struts, buttresses,string or lacing courses, parapets,coping, bed blocks, anchor blocks, plain window sills, fillets etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : BI01010001010000000000000515BI0100001353
243 243 iii) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001354 25 M3
244 244 Comprehensive Annual Maintenance Contract for a period of Seven years for entire Terminal Automation System after successful completion of SAT as described in Technical Bid. \nCost of all the required spares, hardwares, software modification, tools and tackles, ladders, labours, Preventive & Breakdown maintenance Service, calibration of instruments, proving & stampings of metering equipments, rectification/ replacement of faulty TAS equipment etc required for running and maintenance of the entire Terminal Automation System to the desired performance level throughout the contract period of CAMC is included in the item rates and the same has to be borne by the Vendor. \nThe scope also includes posting of Resident Engineer (s) to take care of running and maintenance of the entire Automation System complete as per the tender document. BI01010001010000000000000515BI0100001355
245 245 First Year @4% of the basic CAPEX cost excluding GST @ 18% BI01010001010000000000000515BI0100001356 1 EA
246 246 Second Year @4% of the CAPEX cost excluding GST @ 18% BI01010001010000000000000515BI0100001357 1 EA
247 247 Third Year @7% of the CAPEX cost excluding GST @ 18% BI01010001010000000000000515BI0100001358 1 EA
248 248 Fourth Year @7% of the CAPEX cost excluding GST @ 18% BI01010001010000000000000515BI0100001359 1 EA
249 249 Fifth Year @10% of the CAPEX cost excluding GST @ 18% BI01010001010000000000000515BI0100001360 1 EA
250 250 Sixth Year @6% of the CAPEX cost excluding GST @ 18% BI01010001010000000000000515BI0100001361 1 EA
251 251 Seventh Year @12% of the CAPEX cost excluding GST @ 18% BI01010001010000000000000515BI0100001362 1 EA
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail