Procurement Of Misc . Laboratory Instruments Of Chemical Laboratory, MTPS-West Bengal

Damodar Valley Corporation has published Procurement Of Misc . Laboratory Instruments Of Chemical Laboratory. Submission Date for this Tender is 19-09-2019. Dry Cell Batteries Tenders in MTPS West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

21676130
Procurement Of Misc . Laboratory Instruments Of Chemical Laboratory
Open Tender
Indian
West Bengal
MTPS
19-09-2019

Tender Details

Procurement Of Misc . Laboratory Instruments Of Chemical Laboratory - 2 Digital Water Bath Specification:-1. Display: Digital Display Of Temperature With Set & Process Value; 2. Tank: Ss 304 Grade Tank; 3. Capacity: 5 Litres ( Min. ) ; 4. Temperature Range: Ambient To 99ºc; 5. Temperature Accuracy: ±0.2ºc; 6. Temperature Control: Digital Pid Controller; 7. Timer: 0.1 Hour To 99.9 Hours & Continuous; 8. Safety Protection: User Settable And Fixed Thermal Cut-Out; 9. Alarm: Low Water Level Alarm, Safety Shut Down Audible / Visual Alarm; 10. Operating Voltage: 230±10 Vac, 50 Hz; 11. Tank Designed For Easy Cleaning And Draining 3 Secador Desiccator Cabinet Specification:-1. Dimension ( H×W×D ) : 51×34×41 Cm ( Min. ) ; 2. Adjustable Tray; Make: Tarson / Riviera / Cole Parmer 4 Thermistor Style Digital Thermometer Specification:-1. Range: -50 To 70 Deg C;2. Resolution: 0.01 Deg C; 3. Accuracy: + / - 0.2 Deg C; 4. Probe: Solid Ss Probe; 5. Data Logging Facility 5 Portable Dew Point Meter Specification Make: Alpha Moisture System Ltd. / Cosa Xentaur Corporation / Shaw Moisture Meters ( U.K. ) Ltd. ( Detailed Specification Given In Sl. No. 4 Of Annexure - I ) 6 Digital Magnetic Stirrer Hot Plate Specification 1. Temperature Range: 50 - 450 Deg C; 2. Stirring Range: 100 - 1200 Rpm; 3. Min. Stirring Capacity: 5 Lit; 4. Min. Heating Load: 11 Kg; 5. Material Of Top Plate: Acid-Alkali Resistant Ceramic / Aluminium Top; 6. Dimension Of Top Plate: 7´×7´; 7. Built-In Support Rod Holder; 8. Digital Display Of Set Value & Process Value Of Temperature & Stirrer Speed; 9. External Sensor: Pt-1000; 10. Control Accuracy With External Temperature Sensor: ±0.2ºc; 11. Motor Type: Brushless Dc Motor; 12. Hot Warning Alarm / Display Even In Switched Off Condition; 13. Overheat Protection; Make: Tarson / Riviera / Remi / Cole-Parmer / Thermo Scientific / Borosil 7 Heating Mantle Specification 1. Display: Digital Display Of Temperature With Set & Process Value; 2. Flask Capacity: 500 Ml; 3. Temperature Range: 10 - 400 Deg C; 4. Aluminium Housing; 5. Temperature Control: Full Digital Pid Temperature Controller For Precise Control Of Temperature All Over The Range; 6. Temperature Probe Input; 7. External Sensor: Pt-1000; 8. Support Device At The Rear Of The Base To Hold Standard Rod 8 Vacuum Pump For Sampling Specification 1. Power: 230±10 V / 50 Hz; 2. Max. Power ( W ) : 190 W; 3. Max. Vacuum: -650 Mm / Hg; 4. Horse Power: 1 / 4 Hp; 5. Port Thread: 5 / 16; 6. Noise Level: 52 Db ( Max. ) ; 7. Suitable For Liquid Sampling And Also Perfect For Stack Or Ambient Gas Sampling; Make: Tarson / Riviera / Cole-Parmer / Fisher Scientific 9 Assman Psychrometer Specification 1. Measuring Range Of Thermometer: -30 Deg C To +50 Deg C;2. Resolution: 0.5 Deg C;3. Bulbs Are Installed In A Double Cylindrical Construction To Prevent Direct Sun Ray; 4. Fan: Spring-Wound / Battery Driven;5. Fan Aspiration: 8 Minutes Per Winding;6. Ventilator Fan Having More Air Sucking Facility; Make: Hisamatsu 10 Orsat Apparatus Specification 1. It Should Be Made Of Borosilicate Glass; 2. There Should Be Three Absorption Pipettes Of Two Compartment Type;3. 100 Ml Water Jacketed Gas Burette With Graduation Of 0.2 Ml Least Count;4. Manifold With Stopcock;5. Aspirator Bottle Of Capacity 250 Ml;6. Transparent Flexible Tubes; 7. Leak Proof Transparent Flexible Tubing Connector

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Procurement of Misc. Laboratory Instruments of Chemical Laboratory, MTPS, U#7&8, DVC
Sl. No. Item Description Specification for all Mat: Corten A) Quantity Units
1 1 MECHNICAL(Specification for all MATERIALS: Corten A)
2 1.01 Digital Water Bath Specification:-1. Display: Digital display of Temperature with Set & Process value; 2. Tank: SS 304 grade tank; 3. Capacity: 5 litres (min.); 4. Temperature range: Ambient to 99ºC; 5. Temperature accuracy: ±0.2ºC; 6. Temperature control: Digital PID Controller; 7. Timer: 0.1 hour to 99.9 hours & continuous; 8. Safety protection: User settable and fixed thermal cut-out; 9. Alarm: Low water level alarm, safety shut down audible/visual alarm; 10. Operating voltage: 230±10 VAC, 50 Hz; 11. Tank designed for easy cleaning and draining item1 1 Nos
3 1.02 SECADOR Desiccator Cabinet Specification:-1. Dimension (H×W×D): 51×34×41 cm (min.); 2. Adjustable Tray; Make: Tarson/Riviera/Cole Parmer item2 1 Nos
4 1.03 Thermistor Style Digital Thermometer Specification:-1. Range: -50 to 70 deg C;2. Resolution: 0.01 deg C; 3. Accuracy: +/- 0.2 deg C; 4. Probe: Solid SS probe; 5. Data Logging facility item3 1 Nos
5 1.04 Portable Dew Point Meter Specification Make: Alpha Moisture System Ltd./COSA Xentaur Corporation/Shaw Moisture Meters (U.K.) Ltd. (Detailed Specification given in Sl. No. 4 of Annexure - I) item4 1 Nos/set
6 1.05 Digital Magnetic Stirrer Hot Plate Specification 1. Temperature Range: 50 - 450 deg C; 2. Stirring Range: 100 - 1200 rpm; 3. Min. Stirring Capacity: 5 Lit; 4. Min. Heating Load: 11 Kg; 5. Material of Top Plate: Acid-Alkali resistant Ceramic/Aluminium top; 6. Dimension of Top Plate: 7´×7´; 7. Built-in Support Rod Holder; 8. Digital Display of Set Value & Process Value of Temperature & Stirrer Speed; 9. External Sensor: PT-1000; 10. Control Accuracy with external Temperature sensor: ±0.2ºC; 11. Motor Type: Brushless DC Motor; 12. Hot Warning Alarm/Display even in Switched Off condition; 13. Overheat protection; Make: Tarson/Riviera /Remi/Cole-Parmer/ Thermo Scientific/ Borosil item5 1 Nos
7 1.06 Heating Mantle Specification 1. Display: Digital display of Temperature with Set & Process value; 2. Flask Capacity: 500 ml; 3. Temperature Range: 10 - 400 deg C; 4. Aluminium Housing; 5. Temperature control: Full Digital PID Temperature Controller for precise control of Temperature all over the range; 6. Temperature probe input; 7. External Sensor: PT-1000; 8. Support device at the rear of the base to hold standard rod item6 1 Nos
8 1.07 Vacuum Pump for Sampling Specification 1. Power: 230±10 V/50 Hz; 2. Max. Power (W): 190 W; 3. Max. Vacuum: -650 mm/Hg; 4. Horse Power: 1/4 HP; 5. Port Thread: 5/16"; 6. Noise Level: 52 dB (max.); 7. Suitable for liquid sampling and also perfect for stack or ambient gas sampling; Make: Tarson/ Riviera/Cole-Parmer/Fisher Scientific item7 1 Nos
9 1.08 Assman Psychrometer Specification 1. Measuring Range of Thermometer: -30 deg C to +50 deg C;2. Resolution: 0.5 deg C;3. Bulbs are installed in a double cylindrical construction to prevent direct Sun ray; 4. Fan: Spring-wound/battery driven;5. Fan Aspiration: 8 minutes per winding;6. Ventilator fan having more air sucking facility; Make: Hisamatsu item8 1 ST
10 1.09 ORSAT APPARATUS Specification 1. It should be made of Borosilicate Glass; 2. There should be three absorption pipettes of two compartment type;3. 100 ml water jacketed gas burette with graduation of 0.2 ml least count;4. Manifold with stopcock;5. Aspirator bottle of capacity 250 ml;6. Transparent flexible tubes; 7. Leak proof transparent flexible tubing connector item9 1 SET