Provision Of Automatic Meter Reading And Billing System Including Supply And Installation Of Meters At Officers Married Accn Area Of Little Binaga And Kamat Bay Location And Provision Of Smart Prepaid Meters For Private Parties At Naval Base Karwar, GE(SB) Karwar Naval Base Karwar-Karnataka

Military Engineer Services-MES has published Provision Of Automatic Meter Reading And Billing System Including Supply And Installation Of Meters At Officers Married Accn Area Of Little Binaga And Kamat Bay Location And Provision Of Smart Prepaid Meters For Private Parties At Naval Base Karwar. Submission Date for this Tender is 14-09-2019. Accounting Software Tenders in GE(SB) Karwar Naval Base Karwar Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

21663047
Provision Of Automatic Meter Reading And Billing System Including Supply And Installation Of Meters At Officers Married Accn Area Of Little Binaga And Kamat Bay Location And Provision Of Smart Prepaid Meters For Private Parties At Naval Base Karwar
Open Tender
Indian
Karnataka
GE(SB) Karwar Naval Base Karwar
14-09-2019

Tender Details

Provision Of Automatic Meter Reading And Billing System Including Supply And Installation Of Meters At Officers Married Accn Area Of Little Binaga And Kamat Bay Location And Provision Of Smart Prepaid Meters For Private Parties At Naval Base Karwar

Key Value

Document Fees
INR 500 /-
EMD
INR 68000.0 /-
Tender Value
INR 34 Lakhs /-

BOQ Items

Name of Work : PROVISION OF AUTOMATIC METER READING AND BILLING SYSTEM INCLUDING SUPPLY AND INSTALLATIN OF METERS AT OFFICERS MARRIED ACCN AREA OF LITTLE BINAGA AND KAMAT BAY LOCATION AND PROVISION OF SMART PREPAID METERS FOR PRIVATE PARTIES AT NAVALBASE KARWAR.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply and Installation of AMR enable single phase LPRF Meter with the following specifications:-\n(a) AC single phase two wire, tamper proof, static meter of class 1.0, 240 V, 50 Hz, 10 A - 60 Amps, conforming to IS-13779 and relevant IEC standards with inbuilt low power radio frequency (LPRF) communication facility in 865-867 MHz Cyan Connode or equivalent mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry.\n(b) Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand\n(c) Taking out old energy meter of any description and in any position and depositing to MES store yard complete all as specified and as directed.\nMAKE: CAPITAL/ L&T/ CYANCONNODE/SECURE/HPL 274 Each
2 2 Supply and Installation of AMR enable three phase LPRF Meter with the following specifications:-\n(a) AC three phase four wire, tamper proof, static meter of class 1.0, 415 V, 50 Hz, 10 A - 60 Amps, conforming to IS-13779 and relevant IEC standards with inbuilt low power radio frequency (LPRF) communication facility in 865-867 MHz Cyan Connode or equivalent mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry.\n(b) Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand\n(c) Taking out old energy meter of any description and in any position and depositing to MES store yard complete all as specified and as directed.\nMAKE: CAPITAL/ L&T/ CYANCONNODE/SECURE/HPL 5 Each
3 3 Supply and installation of data concentrator Units (DCU) with the following specifications:-\n(a) IP 51 rated data concentrator unit (DCU) compatible for remote Automatic Meter Reading (AMR) solution and capable of communicating with the static energy Meter in the corresponding LPRF frequency band of 865-867 MHz and with the data server through GPRS and shall have minimum data transfer rate of 9600 bps, internal memory to store data of 50 modules for 6 month period and shall be based on Cyantech Mesh network within 50 meter range. \nMAKE:- CAPITAL/ L&T/ CYANCONNODE/SECURE/HPL 9 Each
4 4 IP 51 rated Repeater unit with inbuilt Low Power Radio Frequency (LPRF) Communication Facility and capable of communicating within Cyantech Mesh network with inbuilt AC power supply. \nMAKE:- CAPITAL/ L&T/ CYANTECH/SECURE/HPL 4 Each
5 5 Supply and installation of GPRS Modem :- \n(a) GPRS commmunication capabilities\n(b) In built protocol stack for meter read, store and forward to central server\n(c) Built in SMPS power suppy from 90 to 470V SC (Single and three phase operation)\n(d) Automatic AT interfacing and GPRS enabling\n(e) Remote modem configuration using GSM-SMS with configured master mobile number\n(f) Remote modem configuration using GPRS \n(g) Scheduled meter data read whenever required\n(h) Automatic meter data packet restoration if GPRS connection fails\n(i) Operating temperature -10 to +60 degree Celcius\n(j) Operating Humidity upto 95% RH (Non condensing)\n(k) Including provision of Sim card\nMake:- AMitech, WIred In , L & T , Secure , HPL 1 Each
6 6 Hosting and configuration of the web based software with following modules:-\n(i) Meter Data Management Module\nThe meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The system would support offline meter data entry.The meter data management system would capture and provide the following data:\n(a) 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy, Power, Current, Voltage, Power Factor and Frequency\n(b) Monthly and quarterly billing survey data for cumulative energy and max demand\n(ii) Billing Module\nThe billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users.\n 279 Each
7 6.01 (iii) Occupation and Vacation Module \nThe system would support occupation / vacation based on the unit categories. The system would support qutomatic data capture on occupation and vacation events.\n(iv) Customer Portal\nThe system would include a customer portal for the resident / occupant to log in and view their own energy / billing data.\n(v) energy / Accounting Module \n The system would include features of energy accounting. the system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available.\n(vi) Comunication module \nThe system would provide communication of energy data and bills via print, email and SMS methods.\n(vii) Meter Master Data\nThe system would support meter master data repository. the system would support meter replacement process.\n(viii) Excel Export\nThe system would support export of metering and billing data in excel format.\nMAKE: INNOLOGIX / L&T/ CAPITAL/ SECURE / HPL
8 7 Four years anuual maintenance and operational cost including Server support, software and GPRS charges post one year manufacturer's warranty . 1116 Each
9 8 Supply and Installation of Single Phase Smart Prepaid meter with the following specifications:-\n(a) AC single phase two wire, tamper proof, static meter of class 1.0, 240 V, 50 Hz, 10 A - 60 Amps, anti tamper features\n(b) Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, \n(c) Meter should have connect / disconnect functionality operable from prepaid billing software\n(d) Meter should have internal or external GPRS modem to provide connectivity with the billing software\n(e) Taking out old energy meter of any description and in any position and depositing to MES store yard complete all as specified and as directed.\nMAKE: CAPITAL/ L&T/ CYANCONNODE/SECURE/HPL 65 Each
10 9 Supply and Installation of Three Phase Smart Prepaid meter with the following specifications:-\n(a) AC Three phase four wire, tamper proof, static meter of class 1.0, 415 V, 50 Hz, 10 A - 60 Amps, anti tamper features\n(b) Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, \n(c) Meter should have connect / disconnect functionality operable from prepaid billing software\n(d) Meter should have internal or external GPRS modem to provide connectivity with the billing software\n(e) Taking out old energy meter of any description and in any position and depositing to MES store yard complete all as specified and as directed.\nMAKE: CAPITAL/ L&T/ CYANCONNODE/SECURE/HPL 13 Each
11 10 Supply and Installation of Three Phase Smart Prepaid meter with the following specifications:-\n(a) AC Three phase four wire, tamper proof, static meter of class 1.0, 415 V, 50 Hz, 5 Amps, CT operated anti tamper features\n(b) Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, \n(c) Meter should have connect / disconnect functionality operable from prepaid billing software\n(d) Meter should have internal or external GPRS modem to provide connectivity with the billing software\n(e) Taking out old energy meter of any description and in any position and depositing to MES store yard complete all as specified and as directed.\nMAKE: CAPITAL/ L&T/ CYANCONNODE/SECURE/HPL\nNote:- (i) Existing CTs are to be used for connecting of CT operated prepaid meters (ii) No extra cost will be paid for central wiring. 7 Each
12 11 Hosting and configuration of the web based software with following modules:-\n(i) Meter Data Management Module\nThe meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data:\n(a) 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy, Power, Current, Voltage, Power Factor and Frequency\n(b) Monthly and quarterly billing survey data for cumulative energy and max demand\n(ii) Prepaid Billing Module\nThe billing module would collect the data from the meter data management module,calculate billing determinant and make energy data / billing data available to admin and end users.\nMAKE: INNOLOGIX / L&T/ CAPITAL/ SECURE / HPL 85 Each
13 12 Five years of operational cost and anuual maintenance support for the software and GPRS provisioning after completion of the project 425 Each
Disclaimer :