Tender For Recycle Of Water Supply For 195 Map Accn At Banikhet Under Age ( I ) Dalhousie
Tender Value
8.30 Lakhs
Estimated cost
Bid Submission
10 Sep 2019
0 days left
EMD
16600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Banikhet → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Recycle Of Water Supply For 195 Map Accn At Banikhet Under Age ( I ) Dalhousie
BOQ
| Name of Work: Recycle of water supply for 195 MAP ACCN at Banikhet under AGE(I) Dalhousie (Job No. MAP-II : Construction of Md Accn at Dalhousie/Bakloh (PKG-MES) Phase-II) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Sch 'A' Part-I B/R Work:-\nExcavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. and getting out in soft/loose soil. | BI01010001010000000000000515BI0100001113 | 14.7 | Cum |
| 2 | 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm | BI01010001010000000000000515BI0100001114 | 3 | Cum |
| 3 | 3 | Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point | 11.7 | Cum | |
| 4 | 4 | Material and labour for PCC 1:4:8 (using 40mm graded granite crushed stone aggregate) type D-2 as in foundation, filling and mass concrete. | 3 | Cum | |
| 5 | 5 | M&L for hardcore of gauge n exc. 63mm, deposited, broken brick bat or broken stone boulders, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified & directed. | 5.55 | Cum | |
| 6 | 6 | Material and labour for Brick work with sub class \"B\" bricks in CM 1:6 straight or curved on plan exceeding 6 M mean radius. | 12 | Cum | |
| 7 | 7 | Rendering 15mm thick in CM 1:6 on fair face of brick or concrete surface and finished fair and even & smooth without using extra cement and providing three coats of white wash all as specified & directed. | 9.15 | Sqm | |
| 8 | 8 | Material and labour for rotational moulded polythene water storage tank of capacity 5000 ltr (cylinderical vertical with closed top) hoisted and fixed in any position including 20mm float valve. | 3 | Each | |
| 9 | 9 | Material and labour for PCC 1:2:4 type B-1 (using 40mm graded granite crushed stone aggregate) as in plinth courses, coping,cills,bed plated and like including weathering slightley rounded or champerd angles and throating as directed including use and waste of form work. | 0.6 | Cum | |
| 10 | 10 | Material and labour for 100 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in, sub base and paving even and fair with out using extra cement all as specified and as directed. | 33 | Sqm | |
| 11 | 11 | Material and labour for 100 mm thick PCC 1:2:4 type B-2 using 20 mm graded crushed stone aggregate as in, sub base and paving even and fair with out using extra cement all as specified and as directed. | 33 | Sqm | |
| 12 | 12 | Sch 'A' Part-II Water Supply Work:-\nExcavation in trenches for laying of pipeline not exceeding 1.5m wide and not exc. 1.5m in depth and getting out in any type of soil. | 105 | Cum | |
| 13 | 13 | Returning, filling in, including spreading, levelling, watering and well ramming in layers and not exc. 25cms. Thick with soil. | 90 | Cum | |
| 14 | 14 | Removal of excavated soil/material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point. | 15 | Cum | |
| 15 | 15 | Supply and fixing 3 layer PP-R polyproplene random copolymer concealed pipes SDR7.4 (PN-16) UV stablized antimicrobial fusion welded having thermal stablity for hot & cold water supply all PP-R plain & brass threaded polyproplene random fittings laid in trenches, floor or wall complete with fittings like socket, bends, reducer, union etc of outer dia 50 mm bore, ISI marked complete all as specified and directed by Engineer-In-Charge. | 30 | RM | |
| 16 | 16 | Supply and fixing High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors or laid in trenches complete with all fittings like socket, bends, reducer, union etc of 40 mm bore, ISI marked complete all as specified and directed by Engineer-In-Charge. | 1300 | RM | |
| 17 | 17 | All as per srl item No. 16 here-in-before but 15 mm bore. | 230 | RM | |
| 18 | 18 | Supply and fixing ball valve suitable for HDPE pipe and fixed for 50mm bore of pipe complete. | 9 | Each | |
| 19 | 19 | All as per srl item No. 18 here-in-before but for 40mm bore pipe. | 2 | Each | |
| 20 | 20 | Supply and fixing bib tap 15mm bore stander of PTMT any colour high pressure for HDPE pipe fixed complete. (Minimum weight 90gms, complete all as specified and directed. | 15 | Each | |
| 21 | 21 | M&L for construction of valve pit complete of internal size 750mm x 750mm x 750mm with sub class 'B' brick, 23Cm thick brick masonry with cement mortar 1:6 and rendering 10mm thick in cement mortar 1:4 internally and flush pointing on the back side in cement mortar 1:3 as the work preceeds and flooring 40mm thick with PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates over 75mm thick hardcore of gauge n.exc.63mm using broken stone/boulders, including 4mm thick MS sheet cover including angle iron frame of size 50x50x5mm complete including painting to all steel surface with two coats of synthetic enamel paint over a coat of red oxide primer, with 150mm long 2 Nos hinges, one No handles of appropiate size and locking arrangement with 65mm brass pad lock with 02 Nos key of Make Godrej or Navtal, including necessary excavation, returning filling and removal of surplus soil to a distance n.exc. 50 mtr complete all as specified and directed. | 2 | Each | |
| 22 | 22 | Supply, installation, comissioning and testing of 2 Nos ( 01 working + 01 stand by) Pumping sets, centrifugal, electric driven, complete of 5 HP suitable for 50mm dia PP-R pipe outlet.complete all as specified and directed.\n | 1 | Each Job | |
| 23 | 23 | Supply, installation, comissioning and testing of 2 Nos (01 working + 01 stand by) Pumping sets, centrifugal, electric driven, complete of 2HP suitable for 50mm dia PP-R pipe out let. complete all as specified and directed. | 1 | Each Job | |
| 24 | 24 | M&L for Demolation of unreinforced cement concrete of any description and any in position. | 2 | cum | |
| 25 | 25 | M&L for cement concrete type D-2 1:2:4 40 mm graded aggregate foundation, filling and mass concret all as specified and directed by Engr-in-charge. | 4 | Cum | |
| 26 | 26 | M&L for header of 160 mm dia bore PP-R pipe of 1.5 mtr length including complete with all fittings like socket, bends, union, end cap, including 2m X 1m X0.5m 1:2:4 PCC base for header including making connection of inlet and outlet with centrifugal pump complete all as specified and directed by Engr-in-Charge. | 2 | Each Job | |
| 27 | 27 | Supply and fix notice plate written as \"NO DRINKING WATER\" duly painted (colour approved by Enge-in-Charge) of size 250mmx250mmx4mm of M.S. plate fixed on angle iron of size 25mmx25mmx4mm with bolt/welding erected in cement concrete (1:2:4) foundation of size 25cmx25cmx40cm the top edge of plate should be 2 feet above from ground level complete all as specifide and as directed. | 15 | Each | |
| 28 | 28 | Sch 'A' Part-III Electric Work:-\nExcavation in trenches for laying of Cable not exceeding 1.5m wide and not exc. 1.5m in depth and getting out in any type of soil. | 10 | Cum | |
| 29 | 29 | Returning, filling in, including spreading, levelling, watering and well ramming in layers and not exc. 25cms. Thick with soil. | 4.5 | Cum | |
| 30 | 30 | Removal of excavated soil/material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point. | 5.5 | Cum | |
| 31 | 31 | Supplying and laying , 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed of follwing size:-\nsize 16 Sqmm, 4 Core | 60 | RM | |
| 32 | 32 | Supplying and laying , 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed of follwing size:-\nsize 10 Sqmm, 3 Core | 13 | RM | |
| 33 | 33 | Supplying and laying , 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed of follwing size:-\nsize 6 Sqmm, 3 Core | 15 | RM | |
| 34 | 34 | Material and labour for sand cushioning to underground cable 8 cm thick layers below the cable and 15 cm thick above the cable in trenches using fine screened river sand complete all as specified and directed by Engr in Charge. (Note:-Punned thickness shall be measured and paid) | 4 | CUM | |
| 35 | 35 | Material and labour for well burnt sub class 'B' bricks of nominal size 230X115X075 mm abutting each other for cable protection all as specified and directed by Engr in Charge. | 434 | Each | |
| 36 | 36 | M&L for Earthing complete with galvanized GI earth plate electrode of size 60 cm x 60 cm x 6.00 mm thick buried directly in ground vertical position earth pit not less than 2.25 mtrs below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized iron strip of size 25 x 4 mm as earth lead by means of bolts ,nuts ,check nuts and washer galvanized iron or steel all as shown in electric plate no 1 of SSR part I connected to earthing test point or as specified or indicated and testing on completion including excavation and earth work in any type of soil, PCC (1:3:6) pit with RCC M-25 cover 54cm x 54 cm x 50 mm thick with hard drawn steel wire fabric weighting exceeding 4 kg/sqm with suitable handle made of 10 mm dia MS bar 20 mm bore GI tubing medium grade watering pipe with funel and wire mesh, 40 mm dia GI light grade protection pipe 5 meter length for drawing earth lead wire protection common salt, charcoal etc complete all as shown in EP No. 1 of SSR 1, testing on completion complete all as specified and directed by Engr in Charge | 2 | Each | |
| 37 | 37 | Supply, installation, testing & commisioning cubical type canopy headed LT feeder pillar box CPRI approved factory made totally enclosed, dust and vermin proof (protection class IP-54) double shutter gear (front & back opening) with locking arrangement made of MS angle iron 40 mmx 40mm x 6 mm & FI 40mm x 6mm frame work and 3.15 mm thick CRCA sheet duly painted powder coated paint after necessary surface preparation. The panel shall be suitable for 415 volts 50 HZ 3 phase 4 wire system and shall be complete for fixing following including internal wiring with copper conductor of suitable size including excavation & PCC work for base and 200 amps capacity busbar duly fixed on 16 nos insulators complete all as specified and directed by Engr-in-charge. Brick masonary should be 60 cms above ground level including comprising of the following:\n(a) MCCB 32 to 40 A 4 pole, 18 KA (Incoming ng for Main supply) - 01 Nos \n(CAT Part NO CM90518OOCO of L&T or equivalent in Havells, Siemens, Legrand))\n(b) MCCB TP 16 A , 415 volts, 4 pole - 04 Nos \n(CAT Part NO CM90517OOCO of L&T or equivalent in Havells, Siemens, Legrand)\n(c) Single phase preventer (O/L range 8-22) - 04 nos\n(CAT Part NO MPR303BE080 of L&T or equivalent in Havells, Siemens, Legrand)\n(d) Voltmeter digital type with selector switch 0-415 A - 01 Nos\n(e) Ampere meter digital type with selector switch 0-400 A - 01 Nos\n(f) Phase indicating lamp (RYB)- 01 Set\n(g) Supply and fixing Direct on line starter for centrifugal pump 5 HP, 5.5 KW including all contractor and over load relay required. L&T CAT part No SS95647 or equivalent in havell ligrend,havells,CG. - 02 nos\n(h) Supply and fixing Direct on line starter for 2 HP centrifugal pump set, 3.7 KW including all contractor and over load relay required. Havells Cat part No IHPDOLLA* or equivalent in L&T, legrant, Siemens - 02 Nos\n\n\n | 1 | Each Job |
AI Tender Summary
Tender Timeline
Sep 03, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedSep 10, 2019
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 12, 2019
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender