| 1 | 1 | Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material outside the University Campus. | item1 | 710 | Sqm |
|---|
| 2 | 2 | Demolishing mud phaska in terrracing including stacking of serviceable material and disposal of unserviceable material outside the University Campus. | item2 | 72 | Cum |
|---|
| 3 | 3 | Providing and laying APP(make Texsa / sika /Pidlite ) modified prefabricated five layer 3mm thick water proofing membrance, black finishing reinforced with non - woven polyster mat consisting of a coat of bitumen primer for bitumen membrance @ 0.40 ltr/sqm. by the same membrance manufacture of density at 25 degree C, 0.87 - 0.89 kg/ ltr. and viscocity 70 - 160 cps. Over the primer coat the layer of mambrane shall be laid using butane torch and sealing all jonts etc., and preparing the surface complete . The vital physical and chemical parameters of membrane shall be : joint strength in longitudinal and transverse direction at 23 degree C as 650/450N/5cm.Tear strength in longitudinal and transverse direction as 300/250N. softening point of membrance not less then 150 degree C. cold flexibility shall be upto - 2 degree C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrance. | item3 | 710 | Sqm |
|---|
| 4 | 4 | 10cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25mm thick mud mortar mixed with bhusa at 35 Kg per Cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks of class designation 100 grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finishing neat: With F.P.S. brick tiles. \n\n | item4 | 710 | Sqm |
|---|
| 5 | 5 | Making khurras 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) over PVC sheet 1mt x 1mt x 400 micron finished with 12mm cement plaster 1:3 ( 1cement : 3 coarse sand) and a coat of neat cement . Rounding the edge and making and finishing the outlet complete. | item5 | 12 | Each |
|---|
| 6 | 6 | Providing angular fillets 75cm x 75 cm cement concrete 1:2:4 (1 cement : 2 sand : 4 crushed aggregate 20 mm nominal size) | item6 | 335 | Rmt |
|---|
| 7 | 7 | Providing and fixing on wall face unplasticised - rigid PVC rain water pipe conforming to IS - 13592 type A including jointing with seal ring conforming to IS :5382 leaving 10mm gap for Thermal expansion. Including all required fitting , sockets, Plain/ Door bends , shoe etc. complete in all respect all lead and lift Single socket pipes - 100 mm diameter of 4kg/cm2 pressure (Prince/ Uniplas/ Finolex)\n | item7 | 92 | Rmt |
|---|
| 8 | 8 | Supply of Labour for cleaning of Roof and other allied works \n | item8 | 70 | Per day |
|---|
| 9 | 9 | 10-15mm thick cement plaster 1:4 (1cement: 4 sand) in single coat on rough/fair side of walls for interior/exterior plastering and making grooves where required. All work upto floor V level. | item9 | 115 | Sqm |
|---|
| 10 | 10 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 metres lead : With cement mortar 1:4 (1Cement: 4 Coarse Sand) | item10 | 55 | Sqm |
|---|
| 11 | 11 | Repair to Washed stone grit plaster in patches including cutting the old damaged grit plaster wherever required on exterior walls of height upto 10m above ground level in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement : 1/2 coarse sand : 2 stone chippings 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing the top layer with brushes and water to expose the stone chippings, complete as per specification and direction of the Engineer-in-charge. inlcuding cost of providing grooves as per required pattern at site. Nothing extra on account of scaffolding shall be paid. The contractor should quote the rate accordingly. | item11 | 20 | Sqm |
|---|
| 12 | 12 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material outside the University Campus. | item12 | 15 | Cum |
|---|
| 13 | 13 | Brick work with common burnt clay F.P.S.(non-modualar) bricks of class designation 75 in foundation, plinth and in superstructure with cement mortar 1:6 (1 cement : 6 sand). All work upto floor V level. | item13 | 15 | Cum |
|---|