| 1 | 1 | Taking down cement plaster on brick surface or stone including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed. | BI01010001010000000000000515BI0100001112 | 500 | Sqm |
|---|
| 2 | 1.01 | M&L for 15mm thick rendering fare/ other than fair faces of brick/stone masonry walls in CM 1:6 finished complete all as specified and directed. | BI01010001010000000000000515BI0100001113 | 1500 | Sqm |
|---|
| 3 | 1.02 | M & L for preparing new plastered or unplastered surfaces of walls and M&L for applying two coat of cement base paint, white or tinted complete all as specified and directed . | BI01010001010000000000000515BI0100001114 | 600 | Sqm |
|---|
| 4 | 1.03 | Preparing old decorated plastered or unplastered surfaces of walls and M&L for applying one coat of cement base paint, white or tinted complete all as specified and directed . | BI01010001010000000000000515BI0100001115 | 500 | Sqm |
|---|
| 5 | 1.04 | M&L for Preparing old decorated plastered or unplastered surfaces of external walls and applying one coat of exterior emulsion paint complete all as specified and directed [Make:-'Apex Paint' of M/s Asian Paints or equivalent in M/s Berger or M/s ICI as approved by GE. | BI01010001010000000000000515BI0100001116 | 500 | Sqm |
|---|
| 6 | 1.05 | M&L for preparation of old plastered surfaces of walls and applying two coats of white wash including complete removal of existing surfaces all as specified and as directed . | BI01010001010000000000000515BI0100001117 | 500 | Sqm |
|---|
| 7 | 2 | Demolition of brick work or stone boulders masonry built in cement mortor or cement lime mortor including all quoins arches pillars etc., but excluding ashlar facing dressed stone work and precast concrete articles, complete all as specified and directed. | BI01010001010000000000000515BI0100001118 | 106.5 | Cum |
|---|
| 8 | 3 | M&L for brick work with sub class 'B' bricks , straight or curved on plan exc. 6 m mean radius built in CM 1:6 complete all as specified and directed. | BI01010001010000000000000515BI0100001119 | 70 | Cum |
|---|
| 9 | 4 | Description same all as per item No 3 above but, except brick using old retrieved bricks obtained from demolition in serviceable conditions complete all as specified and directed. | BI01010001010000000000000515BI0100001120 | 15 | Cum |
|---|
| 10 | 5 | M&L for brick work with sub class 'B' bricks , straight or curved on plan exc. 6 m mean radius in half brick thick walls built in CM 1:4 complete all as specified and directed. | BI01010001010000000000000515BI0100001121 | 100 | Sqm |
|---|
| 11 | 6 | M&L for stone walling of random rubble masonry uncourse, well bonded, bedded and solidly hearted built in CM (1:6) complete all as specified and directed. | BI01010001010000000000000515BI0100001122 | 7 | Cum |
|---|
| 12 | 7 | Description same all as per item No 6 above but, except stone complete all as specified and directed.\n(Note :- Old retrieved stones obtained from demolition in serviceable condition shall be used in the work). | BI01010001010000000000000515BI0100001123 | 3 | Cum |
|---|
| 13 | 8 | M&L for flush pointing to random rubble masonry/stone walling in cement mortar (1:4) complete all as specified and directed. | BI01010001010000000000000515BI0100001124 | 5 | X Sqm |
|---|
| 14 | 8.01 | Demolition of cement concrete ( unreinforced) ground floors and pavings, coping n. exc 15 cm thick below or above ground level and removing the demolished material to a distance exc 500 m but not exceeding 1.5 km and depositing where directed, complete all as specified and directed. | BI01010001010000000000000515BI0100001125 | 3.5 | Cum |
|---|
| 15 | 8.02 | M&L cement concrete 1:4:8 Type D2 (40mm graded Stone aggregate) as in foundation filling and mass concrete all as specified and directed. | BI01010001010000000000000515BI0100001126 | 2 | Cum |
|---|
| 16 | 8.03 | M & L for PCC (1:2:4) type B0, using 12.5mm graded stone aggregate as in coping including necessary form work complete all as specified and directed . | BI01010001010000000000000515BI0100001127 | 1.5 | Cum |
|---|
| 17 | 9 | Dismantling mild steel work of any description not otherwise provided for complete all as specified and directed. | BI01010001010000000000000515BI0100001128 | 3 | Qtl |
|---|
| 18 | 10 | M & L for MS work as in Grills, gratings, etc with ends of bars shouldered and /or riveted, or forged into spikes, framed guard bars, barred iron doors, ladder framed balusters, walk way, railings, frame work of water tanks ad similar work conforming to Fe290 Gde E-165 complete all as specified and directed. | BI01010001010000000000000515BI0100001129 | 1250 | Kg |
|---|
| 19 | 11 | M & L for MS work as in swan neck / brackets, post etc for fencing post & strut in fencing etc including cutting tops to shape as directed, drilling holes, riveting for wires etc including all necessary drilled bolting or riveting etc and similar work conforming to Fe290 Gde E-165 complete all as specified and directed. | BI01010001010000000000000515BI0100001130 | 5000 | Kg |
|---|
| 20 | 12 | S & F in repair galvanized 2 stranded steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and fixing to any type of standard hooks, including securing and tying at crossing with and provision of galvanized mild steel wire staples or steel pins etc complete all as specified and directed. | BI01010001010000000000000515BI0100001131 | 20 | 100 RM |
|---|
| 21 | 13 | Tightening /restraining and resecuring of old existing barbed wire including making good staples etc in same position complete all as specified and directed . | BI01010001010000000000000515BI0100001132 | 20 | 100 RM |
|---|
| 22 | 14 | Preparing new steel & iron surfaces of any description over 10cm in width or girth and M&L for applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed. | BI01010001010000000000000515BI0100001133 | 200 | Sqm |
|---|
| 23 | 15 | Preparing old painted steel & iron surfaces of any description over 10cm in width or girth and M&L for applying one coat of synthetic enamel paint complete all as specified and directed. | BI01010001010000000000000515BI0100001134 | 1000 | Sqm |
|---|
| 24 | 16 | Preparing old painted steel & iron surfaces of any description n.exc over 10cm in width or girth and M&L for applying one coat of synthetic enamel paint complete all as specified and directed. | BI01010001010000000000000515BI0100001135 | 100 | 10 Rm |
|---|
| 25 | 17 | Preparing New painted steel & iron surfaces of any description n.exc over 10cm in width or girth and M&L for applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed. | BI01010001010000000000000515BI0100001136 | 100 | 10 Rm |
|---|
| 26 | 18 | Preparing old painted steel & iron surfaces of any description n.exc over 10cm in width or girth and M&L for applying one coat of Aluminium paint complete all as specified and directed. | BI01010001010000000000000515BI0100001137 | 100 | Sqm |
|---|
| 27 | 19 | Dismantling of posts, struts (wood, steel or RCC) any section including taking out embedded portion in concrete or brick masnory of any position place incl swan neck fencing and making good to disturbed portion, n.exc 0.50 Cum, in soft/loose soil including getting out & removing excavated soil to a distance n.exc 50M and making good disturb surface complete all as specified and directed. all as specified. | BI01010001010000000000000515BI0100001138 | 300 | Each |
|---|
| 28 | 20 | Fixing only Chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provission of binding wire complete all as specified and directed. | BI01010001010000000000000515BI0100001139 | 1500 | Sqm |
|---|
| 29 | 21 | Supply only Chain link MS galvanised fencing any size or type all as specified and directed . | BI01010001010000000000000515BI0100001140 | 6000 | Kgs |
|---|
| 30 | 22 | S&F concertina coil 600 mm dia hot dip galvanized steel wire coated with LLR anticorrosive paint making diamond shape, fixed over babed wire with angle iron all as specified & shown on drawing. One coil of concertina to stretched to 8 mtr only. (Angle Iron, barbed wire etc. shall be measured and paid separately) | BI01010001010000000000000515BI0100001141 | 95 | Each coil |
|---|
| 31 | 23 | S&F concertina coil 1000 /1050 mm dia hot dip galvanized steel wire coated with LLR anticorrosive paint making diamond shape, fixed over babed wire with angle iron all as specified & shown on drawing. One coil of concertina to stretched to 8 mtr only. (Angle Iron, barbed wire etc. shall be measured and paid separately) | BI01010001010000000000000515BI0100001142 | 50 | Each coil |
|---|
| 32 | 24 | M&L for 12mm dia mild steel round bars for securing chain link fencing etc complete all as specified and directed. | BI01010001010000000000000515BI0100001143 | 700 | Kg |
|---|
| 33 | 25 | S&F of Mild steel screw bolt (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square exc 5cm but n.exc 10cm long complete all as specified and directed. | BI01010001010000000000000515BI0100001144 | 150 | Kg |
|---|
| 34 | 26 | Demolition of reinforced cement concrete as in roofs, floors (other than ground floors) beams,Col , staircase, landing, chajjas and similar suspended work all as specified. | BI01010001010000000000000515BI0100001145 | 2 | Cum |
|---|
| 35 | 27 | M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under-reamed piles, raft etc and mass concrete complete all as specified and directed. | BI01010001010000000000000515BI0100001146 | 5 | Cum |
|---|
| 36 | 28 | M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in columns, pillars, piers, posts and struts complete all as specified and directed. | BI01010001010000000000000515BI0100001147 | 3 | Cum |
|---|
| 37 | 29 | M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in floor/roof beam, cantilevers, lintel over 1.5m span complete all as specified and directed. | BI01010001010000000000000515BI0100001148 | 2 | Cum |
|---|
| 38 | 30 | Formwork flat rough finish to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter etc all as specified and directed. | BI01010001010000000000000515BI0100001149 | 70 | Sqm |
|---|
| 39 | 31 | Formwork flat rough finish to sides of pillars, posts, strunts, piers, columns and stanchions etc all as specified and directed. | BI01010001010000000000000515BI0100001150 | 50 | Sqm |
|---|
| 40 | 32 | Formwork flat rough finish to sides and soffits of floor or roof beams, beams, lintels cantilevers shelves including supports, overhangs etc etc also splays between floors and beams etc all as specified and directed. | BI01010001010000000000000515BI0100001151 | 50 | Sqm |
|---|
| 41 | 33 | M & L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete. | BI01010001010000000000000515BI0100001152 | 500 | Kg |
|---|
| 42 | 34 | M & L for Mild steel TMT bars ,5 mm to 10 mm dia as in stirrups , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia.complete all as specified and directed. | BI01010001010000000000000515BI0100001153 | 100 | Kg |
|---|
| 43 | 35 | M&L for 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 and finished the surface even and smooth without using extra cement. | BI01010001010000000000000515BI0100001154 | 105 | Sqm |
|---|
| 44 | 36 | M&L for 5mm thick rendering on fair faces of concrete surfaces in CM 1:3 and finished the surface even and smooth without using extra cement. | BI01010001010000000000000515BI0100001155 | 50 | Sqm |
|---|
| 45 | 37 | S&F welded steel wire febric expanded metal, weight not exceeding 4 Kg Per Sqm, cut to length, bent to shape required tying with and including annealed mild steel wire not less than 0.9 mm dia, or fixing with galvanised steel staples fixed with steel members , post , fencing etc complete all as specified and directed. | BI01010001010000000000000515BI0100001156 | 100 | Kg |
|---|
| 46 | 38 | Ditto - as per Item NO 37 but fixing only | BI01010001010000000000000515BI0100001157 | 50 | Kg |
|---|
| 47 | 39 | Cutting holes in brick walls built in cement mortar exc 150 sq.cm bot n exc 400 sq.cm , complete all as specified and directed. | BI01010001010000000000000515BI0100001158 | 50 | Per CMD |
|---|
| 48 | 40 | Cutting holes in stone walls built in cement mortar exc 150 sq.cm bot n exc 400 sq.cm , complete all as specified and directed. | BI01010001010000000000000515BI0100001159 | 20 | Per CMD |
|---|
| 49 | 41 | M&L for PCC (1:2:4) B-1, using 20 mm graded stone aggregates, as in kerb/benching/coping, bed plates, for fixing hold fast for fencing ( any type) water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. | BI01010001010000000000000515BI0100001160 | 1.7 | Cum |
|---|
| 50 | 42 | M&L for preparing newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed. | BI01010001010000000000000515BI0100001161 | 500 | Sqm |
|---|
| 51 | 43 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern on iron angle, complete all as specified and directed. | BI01010001010000000000000515BI0100001162 | 150 | Sqm |
|---|
| 52 | 44 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering/ MS work ( swan neck / brackets, post etc) to wall, fixed with self tapping screws as specified and directed. | BI01010001010000000000000515BI0100001163 | 100 | Sqm |
|---|
| 53 | 45 | All as per item No 44 above but except sheet complete all as specified and directed | BI01010001010000000000000515BI0100001164 | 50 | Sqm |
|---|