}

Repair /Maintenance Of Ht Vcbs , Rmus , Transformers , Calibration Of Relays Meters Including Connected Works Of 11Kv Ht Distribution System And Repair / Maintenance Of Dg Sets At Ins Dega Under Age E/M No-Ii Of Ge ( U-I ) , Visakhapatnam, Garrison Engineer Utility-I Visakhapatnam-Andhra Pradesh

Military Engineer Services has published Repair /Maintenance Of Ht Vcbs , Rmus , Transformers , Calibration Of Relays Meters Including Connected Works Of 11Kv Ht Distribution System And Repair / Maintenance Of Dg Sets At Ins Dega Under Age E/M No-Ii Of Ge ( U-I ) , Visakhapatnam. Submission Date for this Tender is 17-09-2019. Air Compressor Tenders in Garrison Engineer Utility-I Visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

21561444
Repair /Maintenance Of Ht Vcbs , Rmus , Transformers , Calibration Of Relays Meters Including Connected Works Of 11Kv Ht Distribution System And Repair / Maintenance Of Dg Sets At Ins Dega Under Age E/M No-Ii Of Ge ( U-I ) , Visakhapatnam
Open Tender
NCB
Andhra Pradesh
Garrison Engineer Utility-I Visakhapatnam
17-09-2019

Tender Details

Repair / Maintenance Of Ht Vcbs , Rmus , Transformers , Calibration Of Relays Meters Including Connected Works Of 11Kv Ht Distribution System And Repair / Maintenance Of Dg Sets At Ins Dega Under Age E / M No-Ii Of Ge ( U-I ) , Visakhapatnam , M&L For De-Scaling Of Radiator By Dismantling The Upper & Lower Tank And Cleaning The Core Pipes With Cleaning Chemicals ( Radi Wash ) , Components And Arrest The Leaking Core By Brazing / Dummy With Lead Including Cleaning Of Upper And Lower Tanks And Replacing The Upper And Lower Gaskets And Required Nuts , Bolts , Refixing The Same Including Testing And Painting Complete All As Specified And Directed For The Following Capacities :- , ( A ) 320 Kva Dg Set , ( B ) 250 Kva Dg Set , ( C ) 160 / 200 Kva Dg Set , ( D ) 100 / 125 Kva Dg Set , ( E ) 62 . 5 / 63 Kva Dg Set , ( F ) 30 / 40 Kva Dg Set , M&L For Dismantling The Upper & Lower Tank Of Radiator And Replace The Copper Radiator Core Pipe Including Testing And Painting Complete All As Specified And Directed For The Following Capacities :- , ( A ) 320 Kva Dg Set , ( B ) 160 / 200 / 250 Kva Dg Set , ( C ) 100 / 125 Kva Dg Set , ( D ) 62 . 5 / 63 Kva Dg Set , ( E ) 30 / 40 Kva Dg Set , M&L For Preparation Of Old Painted Steel Surfaces Of Following Capacity Of Dg Sets Including Alternator , Radiator Support Channels Complete , Connected Equipments Complete And Painting With Two Coats Synthetic Enamel Paint Of Approved Colour Complete All As Directed . Note:-1 ) Painting Should Be Done With Existing Colour Codes And Painting Should Apply With The Help Of Spary Gun Using Air Compressor . 2 ) Quotated Rate Shall Deemed To Be Included For Preparation Of Old Painted Surface And Applying Zinc Chrome Primer Over Rusted Portion All As Directed . , ( A ) 320 Kva Dg Set , ( B ) 250 Kva Dg Set , ( C ) 160 / 200 Kva Dg Set , ( D ) 100 / 125 Kva Dg Set , ( E ) 62 . 5 / 63 Kva Dg Set , ( F ) 30 / 40 Kva Dg Set , Cleaning Of Diesel Tank Of Any Capacity Carefully By Draining Out Fuel In The Tank Including Disconnection From Fuel System , Descaling The Diesel Tank With Water Pressure And Removing The Complete Sludge Deposited , Drying The Tank , Repair To Any Leakage , Cleaning And Testing Of Fuel Line Upto Fuel Pump Inlet All As Directed For The Following Capacities :- , ( A ) 320 Kva Dg Set , ( B ) 250 Kva Dg Set , ( C ) 160 / 200 Kva Dg Set , ( D ) 100 / 125 Kva Dg Set , ( E ) 62 . 5 / 63 Kva Dg Set , ( F ) 30 / 40 Kva Dg Set , M & L For Replacement Of Complete Water Hose Pipe Set Including Clips , Nuts , Bolts And Washers Etc Of The Dg Set All As Specified And Dircted By Engr-In-Charge Of Following Capacity:- , ( A ) 320 Kva Dg Set , ( B ) 160 / 200 / 250 Kva Dg Set , ( C ) 100 / 125 Kva Dg Set , ( D ) 62 . 5 / 63 Kva Dg Set , ( E ) 30 / 40 Kva Dg Set , M & L For Replacement Of Complete Fuel And Lub Oil Hose Pipe Set With Clamp / Clip Etc Of The Following Capacity Of Dg Sets:- , ( A ) 320 Kva Dg Set , ( B ) 160 / 200 / 250 Kva Dg Set , ( C ) 100 / 125 Kva Dg Set , ( D ) 62 . 5 / 63 Kva Dg Set , ( E ) 30 / 40 Kva Dg Set , Supply And Replace Automatic Battery Charger Of 12 / 24 Volt , 0-10 Amps / 0-5 Amps Charging Rate With Auto Cut Off System Complete All As Specified Make: Elak Model: Ac-03 / Amara Raja Or Equivalent , M & L For Replacement Of Battery Lead Set Of 2 Nos 1 . 5 Mtr Long Copper Lead Of 35 Sqmm Size Including Gm Terminals At One End And Coper Lug At Other End All As Directed , Supply And Replace Ampere Meter Of Rating Upto 0 To 500 Amps , 96 X 96 Mm Square Flush Mounting Type As Reqiured At Site All As Specified . , Supply And Replace Volt Meter 3 Phase 415 Volt , 0-500 Volts , 96 X 96 Mm Square Flush Mounting Type All As Specified . , M&L For Repair And Servicing Of Self Starters Including Replacement / Rewinding Of Armature , Carbon Brush Set With Holder , King Pin Holder , Check Nut , Body Screens , Clutch Plate Assembly And Solenoid Switch Etc All As Directed For The Following Capacity Of Dg Sets:- , ( A ) 320 Kva Dg Set , ( B ) 160 / 200 / 250 Kva Dg Set , ( C ) 100 / 125 Kva Dg Set , ( D ) 62 . 5 / 63 Kva Dg Set , ( E ) 30 / 40 Kva Dg Set , Supply And Toping Up Of Engine Oil 15W40 Or As Per Manufacturers Recommendations For Topping Up Or Replacement . Make: Castrol / Servo / Hpcl , Supply And Toping Up Of Radiator Coolents As Per The Rcommendation Of Engine Manufacturer All As Directed . , M&L For Carrying Out B Check For Dg Set 320 Kva , As Per Manufacturers Recommendation Including Replacement Of Fuel Filters , Air Filters And Oil Filters , O Rings , Engine Oil , Gasket , Coolant Etc Complete . Make Of Engine: Greaves Cotton , M&L For Carrying Out B Check For Dg Set 200 / 250 Kva , As Per Manufacturers Recommendation Including Replacement Of Fuel Filters , Air Filters And Oil Filters , O Rings , Engine Oil , Gasket , Coolant Etc Complete . Make Of Engine: Greaves Cotton / Ashok Leyland , M&L For Carrying Out B Check For Dg Set 100 / 125 Kva , As Per Manufacturers Recommendation Including Replacement Of Fuel Filters , Air Filters And Oil Filters , O Rings , Engine Oil , Gasket , Coolant Etc Complete . Make Of Engine: Cummins , M&L For Carrying Out B Check For Dg Set 160 Kva , As Per Manufacturers Recommendation Including Replacement Of Fuel Filters , Air Filters And Oil Filters , O Rings , Engine Oil , Gasket , Coolant Etc Complete . Make Of Engine: Cummins , M&L For Carrying Out B Check For Dg Set 62 . 5 / 63 Kva , As Per Manufacturers Recommendation Including Replacement Of Fuel Filters , Air Filters And Oil Filters , O Rings , Engine Oil , Gasket , Coolant Etc Complete . Make Of Engine: Kirloskar / Cummins , M&L For Carrying Out B Check For Dg Set 30 / 40 Kva , As Per Manufacturers Recommendation Including Replacement Of Fuel Filters , Air Filters And Oil Filters , O Rings , Engine Oil , Gasket , Coolant Etc Complete . Make Of Engine: Kirloskar / Cummins , Disconnecting And Removing Existing Unserviceable Battery And S&F Maintenance Free Battery 12V 100 Ah With Minimum 2 Years Warrenty All As Specified And As Directed By Engineer-In-Charge . [ Make: Exide / Amco / Amron ] , Disconnecting And Removing Existing Unserviceable Battery And S&F Maintenance Free Battery 12V 180 Ah With Minimum 2 Years Warrenty All As Specified And As Directed By Engineer-In-Charge . [ Make: Exide / Amco / Amron ] , Checking Complete Wiring For Amf Panel And Identifying Fault In The Safety And Control System Wiring From Amf Panel To Engine Control Gadgets Like Hwt . Llop , And Shut Down Valve , Dynamo Self-Starter Etc For 250 / 320 Kva Dg Set Engine And Rectifying Fault In The Amf System Including Replacement Of Ec-2 Relay , Suitable Capacity Of Contactor , Burnt Control Wiring Cable With Thimbles And Ferrules , Blown Out Fuses For Proper Fuctioning And Testing The Dg Set All As Directed , Checking Complete Wiring For Amf Panel And Identifying Fault In The Safety And Control System Wiring From Amf Panel To Engine Control Gadgets Like Hwt . Llop , And Shut Down Valve , Dynamo Self-Starter Etc For 160 / 200 Kva Dg Set Engine And Rectifying Fault In The Amf System Including Replacement Of Ec-2 Relay , Suitable Capacity Of Contactor , Burnt Control Wiring Cable With Thimbles And Ferrules , Blown Out Fuses For Proper Fuctioning And Testing The Dg Set All As Directed , Checking Complete Wiring For Amf Panel And Identifying Fault In The Safety And Control System Wiring From Amf Panel To Engine Control Gadgets Like Hwt . Llop , And Shut Down Valve , Dynamo Self-Starter Etc For Up To 125 Kva Dg Set Engine And Rectifying Fault In The Amf System Including Replacement Of Suitable Capacity Of Contactor , Burnt Control Wiring Cable With Thimbles And Ferrules , Blown Out Fuses For Proper Fuctioning And Testing The Dg Set All As Directed , M&L For Disconnecting Carefully Electrical Connection From Both Ht / Lt ( Primary & Secondary ) Sides Of

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail