Design Engineering Supply Fabrication Erection Construct Of Peb Pre Engineered Building Shed Or Warehouse With Mezzanine Floor Smoke Detection Sprinkler System Along With Associated Allied Civil Structural Elect Instrum Mech Works At Scfp Tadepalli, SCFP Tadepalli (Andhra Pradesh)-Andhra Pradesh

Indian Oil Corporation Limited-IOCL has published Design Engineering Supply Fabrication Erection Construct Of Peb Pre Engineered Building Shed Or Warehouse With Mezzanine Floor Smoke Detection Sprinkler System Along With Associated Allied Civil Structural Elect Instrum Mech Works At Scfp Tadepalli. Submission Date for this Tender is 11-09-2019. Fabrication Work Tenders in SCFP Tadepalli (Andhra Pradesh) Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

21560909
Design Engineering Supply Fabrication Erection Construct Of Peb Pre Engineered Building Shed Or Warehouse With Mezzanine Floor Smoke Detection Sprinkler System Along With Associated Allied Civil Structural Elect Instrum Mech Works At Scfp Tadepalli
Open Tender
Indian
Andhra Pradesh
SCFP Tadepalli (Andhra Pradesh)
11-09-2019

Tender Details

Design Engineering Supply Fabrication Erection Construct Of Peb Pre Engineered Building Shed Or Warehouse With Mezzanine Floor Smoke Detection Sprinkler System Along With Associated Allied Civil Structural Elect Instrum Mech Works At Scfp Tadepalli

Key Value

Document Fees
Refer document
EMD
INR 612837.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Design, engineering, supply, fabrication, erection and construction of PEB (PRE-ENGINEERED BUILDING) shed / warehouse with mezzanine floor with smoke detection & Sprinkler system along with the associated allied civil, structural, electrical & instrumentation and mechanical works at SCFP Tadepalli.
Sr. No. Item Description Item Code / Make Quantity Units
1 1 Design, Engineering, Supply, fabrication, transporting, assembling & erecting in place, the Pre-designed, Pre-Engineered Prefab Structure including all columns, rafters, purlins, portals, trusses, beams, plates, sag rods, etc., with all primary & secondary structural members, etc complete for PEB shed having dimension of 50 M x 28 M with clear span of approx. 28 M, and catilever portion of 30 M x 5 M as per drawing. All structure to be painted with approved painting scheme as per the enclosed IOCL specifications. All fasteners to be used for fitting the roof and holding surface should be of non rusting coated. This item also includes Design, Preparation and submission of design details, detailed fabrication drawings for Pre Engineered Building. The design and drawings to be provided as per the IS norms in applicable zone and shall be finalized by IOCL/ consultant. Item also includes designing of entire structure and suitable foundation in line with enclosed specification & annexure. The job also includes providing monkey ladder in approved design, section thickness for safe access to roof. The design should be such that weather shade of effective widths & span, over openings are built within the form itself. Major Fabrication work shall be carried out at Shop/Factory. For Fabricated Plate Girder Steel Plates conform to IS 8500 Gr 540B Fe shall be used. All Rolled section shall conform to IS2062 Gr Fe 410 WA. Only connection/ fittings shall be permitted at site as directed by IOCL/ Consultant. The rate includes welding weights, site connection, nut & bolts, required dia anchor / foundation bolts with templates as per structure design and same will not be measured for payment. Only theoretical Weight of as built Structural members shall be measured for payment purpose. \nThe rate also include vetting of complete structural design by two govt. approved structural design engineers or consultants ( preferably govt institutes like IIT / VJTI etc.) and submission of structural stability certificate as per the requirement of MIDC or IOCL.\nPainting scheme shall be as:\n a) Surface preparation by shot blasting conforming to SA 2.5 (to be done at shop) b) Prime coat of Epoxy Based Zinc Ethyle Silicate Primer (min. 60% vol. solids), one coat of 75 - 80 micron DFT. (to be done at shop c) Intermediate coat of TWO PACK EPOXY HIGH BUILD MIO COATING (min. 60% vol. solids). one coat of 100 -125 micron DFT (to be done at field after touch up primer on welded surfaces).\nd) Final coats of TWO PACK ALIPHATIC ACRYLIC POLYURETHANE (min. 52% vol. solids), Two coats of combined 60 -70 micron DFT (to be done at field/Shop). Total DFT shall be 275 micron. Painting shall be done strictly as per the instruction of IOCL/CONSULTANT. Intermediate/Final Coat may be required to provide at Shop/field as directed by IOCL engineer in charge. (Rate shall include cost of supply of paint, primer, surface preparation, scaffolding all complete as per instructions of CONSULTANT/IOCL Engineer-in-Charge). Primer & paint shall be of approved make as specified by CONSULTANT/IOCL. BI01010001010000000000000515BI0100001115 115 MT
2 2 Demolishing C.C. /R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1000m, stacking serviceable and unserviceable material separately including cutting reinforcement bars. BI01010001010000000000000515BI0100001117 280 M3
3 3 Demolishing brick work manually/mechanical means including stacking of serviceable material & disposal of unserviceable material outside site at unobjectionable place & as/direction of Engineer-in-charge. BI01010001010000000000000515BI0100001118 10 M3
4 4 Demolishing stone masonry manually/ by mechanical means including stacking serviceable material & disposal of unserviceable material out of site at unobjectionable place and as per direction of Engineer-in-charge: BI01010001010000000000000515BI0100001119 75 M3
5 5 Excavation & Backfilling in All Types of Ordinary soil including blackish brown clayey soil, upto 1.5 m depth below FGL/NGL: Excavation and backfilling around foundation and trenches/pits in all types of soil viz. earth, sand, gravel, clay, soft & hard murum, Asphalt, WBM etc. (excluding soft/hard rock) for footings, steps, plinth beams, equipment foundations, drains, trenches, manholes, underground tanks/pits, etc including shoring strutting, dewatering wherever required (until foundation work is complete). Item also includes carting, stacking if required, filling, Spreading, levelling and compacting / consolidating, disposal of surplus materials outside IOCL premises to an unobjectionable place following local rules or as per instructions of CONSULTANT/IOCL Engineer In Charge (Rate includes removal of any vegetation, small shrubs etc.)\nAll Excavation Work has to be carried out Strictly as per Specification for Earthwork in Excavation. BI01010001010000000000000515BI0100001120 1450 M3
6 6 Excavation & Backfilling in All Types of Ordinary soil including blackish brown clayey soil, from 1.5 m to 3.0 m and more depth below FGL/NGL: Excavation and backfilling around foundation and trenches/pits in all types of soil viz. earth, sand,gravel, clay, soft & hard murum, Asphalt, WBM etc. (excluding soft/hard rock) for footings, steps, plinth beams, equipment foundations, drains, trenches, manholes, underground tanks/pits, etc including shoring strutting, dewatering wherever required (until foundation work is complete). Item also includes carting, stacking if required,filling, Spreading, levelling and compacting/ consolidating, disposal of surplus materials outside IOCL premises to an unobjectionable place following local rules or as per instructions of CONSULTANT/ IOCL Engineer In Charge (Rate includes removal of any vegetation, small shrubs etc.). All Excavation Work has to be carriedout Strictly as per Specfication for Earthwork in Excavation. BI01010001010000000000000515BI0100001121 3250 M3
7 7 Filling with available good excavated earth (Excavation excluded, rock excluding) Filling the sides of foundations, sub-structures, Plinth/below Grade Slab for development of plot etc. with approved quality of earth laid in layers not exceeding 300 mm in loose thickness including levelling, watering, ramming, rolling, compacting with 10-12MT mechanical roller / hand compactor/ mechanical rammer to 95% Modified Proctor Density etc as per specification in Earthwork in Filling. complete with any lead within 1 KM from IOCL premises as directed and instructed by CONSULTANT / IOCL Engineer In charge. The item includes cost of dewatering if required including payment of Royalty to Owner of borrow pit, if applicable; payment of applicable royalties, taxes, etc to Statutory Authority. All Filling Work shall be carried out Strictly as per Specification for Earthwork in Excavation. BI01010001010000000000000515BI0100001122 4680 M3
8 8 Filling with imported murrum in Plinth/below Grade Slab Supplying and filling with good quality of approved earth with PI (Plasticity Index) of 1 to 7 (Low plastic) containing not more than 20% cohesive fines namely clay and Max. dry density of material not less than 1.80 gm/cc below grade slab / within plinth, including identifying & locating of borrow pits, excavation at borrow pits outside Plant premises; including payment of Royalty to Owner of borrow pit, if applicable; payment of applicable royalties, taxes, etc to Statutory Authority for operating the borrow pit; loading at borrow pit end; including transportation from borrow pit to IOCL Premises; removing debris, organic matter, etc; spreading in layers not exceeding 300 mm loose depth; rolling, compacting with 10-12 MT mechanical roller / hand compactor/mechanical rammer to 95% Modified Proctor Density etc as per specification in Earthwork in Filling, dewatering during course of filling, watering, compacting the murum or sand to obtain 95% of modified proctor maximum laboratory dry density all complete as per specifications and instructions of IOCL Engineer-in-Charge. All Filling Work shall be carried out Strictly as per Specification for Earthwork in Excavation. BI01010001010000000000000515BI0100001123 500 M3
9 9 Sand Filling: Supplying and filling locally available good quality river sand in trenches, pits etc and under foundations in layers of 150 mm thick including watering and compacting to achive 95 % Modified Proctor Density etc all complete as per instructions of IOCL/CONSULTANT Engineer-in-Charge. BI01010001010000000000000515BI0100001124 90 M3
10 10 Anti-termite treatment\n'Anti termite treatment to bottom surface (in case of masonry foundation and basements) and the sides (upto a height of 300 mm from bottom) of the excavated trenches with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration)with water by weight at the rate of 5 litres per sq.m. area. The work shall be carried out as per specification described in 6.2.1 of code IS-6313 (part - II) 1981. (Mode of measurement will be the plan area of foundation treated). BI01010001010000000000000515BI0100001125 1400 M2
11 11 PCC (1:4:8) Providing and laying Plain Cement Concrete of nominal volumetric mix 1:4:8 (1 Cement: 4 Sand: 8 Crushed stone aggregates) with 40 mm and down size graded aggregates below RCC foundations and grade slab & any other work as per requirement including any required permanent brick /stone masonry including shuttering, dewatering, tamping, ramming, curing, etc with all leads & lifts and all complete as per instructions of CONSULTANT/IOCL Engineer-in- Charge. All PCC Work shall be carried out Strictly as per Specification for Plain & Reinforced Cement Concrete. BI01010001010000000000000515BI0100001126 5 M3
12 12 PCC (1:3:6) Providing and laying Plain Cement Concrete of nominal volumetric mix 1:3:6 (1 Cement: 3 Sand: 6 Crushed stone aggregates) with 40 mm and down size graded aggregates below RCC foundations and grade slab & any other work as per requirement including any required permanent brick /stone masonry including shuttering, dewatering, tamping, ramming, curing, etc with all leads & lifts and all complete as per instructions of CONSULTANT/IOCL Engineer- in-Charge. All PCC Work shall be carried out Strictly as per Specification for Plain & Reinforced Cement Concrete BI01010001010000000000000515BI0100001127 300 M3
13 13 PCC (1:2:4) Providing and laying Plain Cement Concrete of nominal volumetric mix 1:2:4 (1 Cement: 2 Sand: 4 Crushed stone aggregates) with 40 mm and down size graded aggregates below RCC foundations and grade slab & any other work as per requirement including any required permanent brick /stone masonry including shuttering, dewatering, tamping, ramming, curing, etc with all leads & lifts and all complete as per instructions of CONSULTANT/IOCL Engineer- in-Charge. All PCC Work shall be carried out Strictly as per Specification for Plain & Reinforced Cement Concrete. BI01010001010000000000000515BI0100001128 20 M3
14 14 DPC 40 mm thick with CC 1:2:4\nProviding and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes mixing water proofing material in cement concrete work @ 1 kg per 50kg of cement. Applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square meter on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil. BI01010001010000000000000515BI0100001129 10 M2
15 15 230mm thk. Rubble Soling with manual compaction Providing, supplying and placing 230 mm thick dry rubble stone packing/soling under floor, foundation, pavement, roads, steps, ramps & other similar locations, handset vertically in rectangular lines, interstices filled in with smaller stone chips including watering, compacting/consolidating & finishing to the required levels and lines etc with manual compaction etc complete as directed by CONSULTANT/IOCL Engineer-In- Charge. (Blinding layer shall be of metal, sand or murrum supplied by contractor) BI01010001010000000000000515BI0100001130 3100 M2
16 16 WBM\nSupply and laying of water bound macadam in layers, each of 75 mm thick (consolidated) with 63 mm to 45 mm stone aggregate. Each layer shall be consolidated by power roller after watering, spreading chippings of stone and murrum complete as per specifications. Item includes supply of murrum 6 mm thick, watering and rolling with power roller complete with preparation of surface. Rate per Layer BI01010001010000000000000515BI0100001131 6180 M2
17 17 RCC M 30 Below Plinth (Below FFL) \nProviding and laying in position ready mixed concrete of M30 grade, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all structures, equipment foundations, columns, beams, floors, slabs, roof slabs, buildings lintels, gutters staircases, fins, chajjas, pardis, sills, copings, projections, column/ beam encasings etc. all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , including the cost of centering, shuttering finishing but excluding the reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. (Note :- Cement content considered in this item is @ 340 kg/cum. BI01010001010000000000000515BI0100001132 750 M3
18 18 RCC M 30 above Plinth (Above FFL) Same as RCC M30 Below plinth but Concrete for RCC works at all levels above plinth level for all structures, equipment foundations, columns, beams, floors, slabs, roof slabs, buildings lintels, gutters staircases, fins, chajjas, pardis, sills, copings, projections, column/ beam encasings etc.(up to a ht.of 8 mts.) above plinth level. BI01010001010000000000000515BI0100001133 100 M3
19 19 HYSD Bars of Grade Fe 415 /500 TMT for reinforcement Supplying and placing in position High Yield Strength deformed TMT Bars conforming to IS: 1786, Fe415/500 for beams, slabs, columns, etc at all levels and locations of RCC work with all leads & lifts. including transporting the steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per specifications, binding with Contractor's own 16 gauge SWG binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, spacers, etc. all complete as per Bar bending schedule approved by CONSULTANT/IOCL Engineer-in-Charge. Separate measurement will be made under this item for authorised laps only as per approval of IOCL/Consultant.\nAll Reinforcement Work shall be carriedout Strictly as per Specification for Plain & Reinforced Cement Concrete. The weight of reinforcement shall be calculated as per theoretical weight given in standard steel table and wastage/ unauthorized overlaps/binding wires shall not be payable extra. BI01010001010000000000000515BI0100001134 118000 KG
20 20 Providing & laying design mix cement concrete of M-30 grade, in roads driveways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as/approved & specified design criteria,providing dowel bars with sleeve/ tie bars wherever reqd, laying at site, spreading & compacting, mechanically by screed board vibrators, vacuum dewatering process and finally finished by floating,brooming with wire brush including steel form work with sturdy MS.channel sections, curing making provision for contraction / expansion, construction and longitudinal joints( 10 mm wide x 50 mm deep ) by groove cutting machine, providing and filling joints with approved joint filler and sealants,complete all as/direction of Engineer -in- Charge (Dowel & tie bars to be paid separately under reinforcement) Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess / less cement used as / design mix is payable/ recoverable separately. BI01010001010000000000000515BI0100001135 625 M3
21 21 Providing & laying 80mm thick factory made Pre-cast cement concrete interlocking paver block of M 40 grade made by block making machine with strong vibratory compaction & of approved size and design/ shape shade and manufacturers and as per IOCL's specifications. The paver block will have peripheral chamfer,with average crushing strength more than 40 N/Sq.mm as/ BS6717 Part -1(1986), maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length & width and +/- 3mm on on thickness. The job includes supplying & laying a layer of 50mm thick clean course sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand,compacting with machine vibrator to required line and level, etc. complete.(Payment for provision of edge restraints shall be made separately);- Grey or Coloured 80mm thick paver blocks BI01010001010000000000000515BI0100001136 800 M2
22 22 Structural works Pipe Racks/ Pipe Supports & other Miscellaneous work Supplying, fabricating, welding and/or bolting, as required, erecting and fixing in position all types of structural steel work viz Beams, columns ,plates, bracings shop fabricated including all accessories viz. nuts, bolts, cleats, gussets,base plate, etc as per specification complete as directed by CONSULTANT/IOCL Engineer in charge. All Plates and Rolled Section Shall conform to IS 2062 Gr Fe 410 WA or Gr Fe 410 WB. The rate to include for welding weights, site connection, nut & bolts and same will not be measured for payment. This item includes the two coat of red oxide and one coat of synthetic enamle paint. Only theoretical Weight of Structural members shall be measured for payment purpose. All Structural Work shall be carried out Strictly as per Specification for Structural Steel Work BI01010001010000000000000515BI0100001137 30000 KG
23 23 Structural steel work in built up sections/ framed work in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cutting,hoisting,fixing in position.\nAll Painting Work shall be carried out preferably at Shop or as directed by IOCL Engineer in charge as per painting scheme given for above for PEB work. Final Touch up Paint may be provided at site after erection as directed by IOCL/CONSULTANT.\n- (Rate shall include cost of supply of paint, primer, surface preparation, scaffolding all complete as per instructions of\nCONSULTANT/IOCL Engineer-in-Charge). Primer & paint shall be of approved make as specified by CONSULTANT/IOCL\n\n\n BI01010001010000000000000515BI0100001138 7000 KG
24 24 230 thk Brick Masonry in CM 1:4 Supplying & constructing 230 thk brick masonary walls using bricks of first class burnt clay (class 5.0 as per IS:1077, Compressive strength of Brick 50 kg/cm2) of approved source at all locations and levels with cement mortar (1:4) including scaffolding, racking of joints, watering, but excluding cement plaster finish complete as directed and instructed by IOCL/Consultant Engineer incharge. Brickwork shall be carried out strictly as per Specification for Brick Masonry Work. BI01010001010000000000000515BI0100001139 200 M3
25 25 115 thk half Brick Masonry in CM 1:4 Supplying and constructing 115mm thick burnt clay brick masonry in super structure using first class bricks (class 5.0 as per IS:1077, Compressive strength of Brick 50 kg/cm2) of approved source in cement mortar (1:4) including necessary scaffolding, racking of joints, providing horizontal reinforcement mesh comprising of ms flats of section 3X25 or ms round bars of 6 to 8mm dia in every third or fourth course to increase its lateral stability and for anchoring with load bearing wall, watering but excluding cement plaster finish complete as directed and instructed by IOCL Engineer in charge.(up to a lift of 12 mts.) Transoms & mullions shall be provided in the brick work when length or height of wall exceeds 2M. Transoms shall be provided at lintel/door height. Spacing of mullions shall not exceed 1.5M c/c. Size of transoms/ mullions shall be 115mm x 115mm with M15 grade concrete using 10mm & down graded aggregate only. Supplying and placing formwork etc for transoms/ mullions etc shall be included in the quoted rate. BI01010001010000000000000515BI0100001140 100 M2
26 26 Random rubble masonry below plinth Random rubble masonry with hard stone in superstructure below plinth level, including levelling up with cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 20mm nominal size) with cement mortar 1:6 (1 cement: 6 sand ) as directed by IOCL/Consultant. BI01010001010000000000000515BI0100001141 225 M3
27 27 Random rubble masonry above plinth Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 20mm nominal size) with cement mortar 1:6 (1 cement: 6 sand ) as directed by IOCL/Consultant. BI01010001010000000000000515BI0100001142 175 M3
28 28 Colour Coated Profile Sheet for roofing/wall cladding\nProviding & fixing colour coated Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of bare metal thickness 0.50mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, with 5-7 micron epoxy primer and polyester top coat of 15-18 micron on both sides,total coated thickness(TCT) of 0.58mm.Sheet shall have protective guard film of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6 m or as desired by Engineer-in-charge. The fixing of sheet shall be complete as per manufacturer's specification including provision of Clip, washer, bolts, nuts, self drilling high grip screws with integral washeras necessary for fixing all complete as directed & instructed by CONSULTANT / IOCL Engineer. \nThe item also includes supply and fixing of Polycarbonate Translucent sheet of 2 mm thk having top surface plain & bottom surface textured and profile compatible with Zincalume /galvalume sheet with all accessories. The area of Polycarbonate Translucent sheet will be approx. @ of 5% of total covered area for lighting in both roofing & Cladding in matching profile of galvalume sheet as decided by IOCL. The measurement for payment shall be only for covered area for considering Polycarbonate and Galvalume sheets (i.e. net of covered area). BI01010001010000000000000515BI0100001143 3800 M2
29 29 Supplying, erecting and fixing in position plain sheet 600 mm wide Colour coated galvalume ridge cap and corner flushing rolled from 0.58 mm TCT BHP Zincalume AZ-150 High tensile steel (Minimum yield strength of 275 Mpa) including fixing to Sheets stiched by (4.8 x 16 mm) Hex head stitch screws with metal bounded EPDM washers complete in all respects inclusive of cost of all labour, materials, tool, tackles etc. as per specification and direction of Site Engineer/ Engineer-in-Charge. The specification of plain sheet for Ridge shall be the same as of clip-on sheet. BI01010001010000000000000515BI0100001144 50 M2
30 30 Same as above but Plain Sheet for Gutter (600 mm over all girth) with all the necessary accessories required including brackets, welding clamps, bolts, nuts galvanised iron and bituminious washers, drop ends, nozzles, stop ends etc. laid to required slopes making joints water tight, testing etc.complete as specified and directed. The specification of plain sheet for Ridge shall be the same as of clip-on sheet. BI01010001010000000000000515BI0100001145 100 M
31 31 Turbo Air Natural Ventilator at Roof : Providing & Fixing of Turbo Air Natural Roof Ventilator with 2 mm thk UV Stabilized FRP Base profile to match with Galvalume roof sheeting with adequate overlaps in all sides to avoid seepage/ leakage of water. The FRP Base of the Turbojet will be Tapering from minimum 750 to achieve 600m throat at top. The height of the Turbojet shall be about 600 mm. The ventilators shall have Vanes made out of Hi-Grade Industrial Aluminium and top plate & bottom ring of stainless steel.The turbojet shall have permanently lubricated & sealed type double bearing such as 6001ZZ of SKF and it should be maintenance free & leak proof. Turbojet shall be installed as per manufacturer specification and as directed by IOCL/CONSULTANT Engineer in charge. BI01010001010000000000000515BI0100001146 50 EA
32 32 Internal Cement plaster 12mm thk. Providing & applying cement plaster in C.M. 1:4 mix to all RCC & masonry work at all levels and locations including grooves, pattas,drip moulding, scaffolding, watering, raking out joints in masonary or concrete work as per masonry & plaster specification. The rate to include providing and fixing of 200mm wide chicken wire mesh of 26G & 12mm mesh size at the junction of different construction materials. The cement used shall be Portland Pozzolana Cement (Uniform Blended Portland cement with fine pozzolana) conforming to IS:1489 Part 1 and Part 2 BI01010001010000000000000515BI0100001147 500 M2
33 33 Providing and applying external sand faced plaster 20mm thk consists of 12 mm thk in C.M. 1:6 first coat and 8 mm thk in CM 1 : 2 second coat to all RCC and masonry works at all locations and levels including required grain finishing, curing etc. complete as per specification and as directed and instructed by CONSULTANT / IOCL Engineer in charge. NOTE: The rates includes the cost of the base coat of not less than 12mm thk., external patta, drip moulds, curing and providing and fixing 200mm wide G.I. chicken mesh 26g thk. & 15mm mesh size at junctions of brick and RCC/PCC work etc. as well as providing and mixing waterproofing compound of approved make in both coats as per manufacturers specifications. BI01010001010000000000000515BI0100001148 500 M2
34 34 Providing specified type of pointing in brick or stone masonry including curing etc. \nRaised and cut pointing on stone work with cement mortar 1:3 (1 cement: 3 fine sand) BI01010001010000000000000515BI0100001149 200 M2
35 35 Epoxy Finished Flooring Epoxy Painting in Floor for marking as directed by IOCL/CONSULTANT Engineer in change and as per Manufacturer Specification BI01010001010000000000000515BI0100001150 10 M2
36 36 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/stainless steel screws including fixing all complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately.\nFor windows & ventilators with powder coated aluminium sections including providing fixing hings/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (fitting shall be paid for separately). BI01010001010000000000000515BI0100001151 500 KG
37 37 Providing & Fixing Glazeing in with Toughened glass pans of 6mm thk. alluminium window EPDM rubber / new prene gaskate it is complected archti drg. And direction engg- in charage (cost of alliuminium snap bedding shall be paid in seperately. BI01010001010000000000000515BI0100001152 25 M2
38 38 Rolling Shutters (Motor operated) Gear operated type-rolling shutters with gear box and crank handle at waist level on inside as well as outside Providing & fixing rolling shutter made out of 18 gauge steel sheets for laths, including bottom rail, guide channels, lock plates, locking arrangement, fixing bolts, pulling handles, hood, rolling arrangement, standard make springs in brackets, necessary bearings, etc. including fixing of frames with rag bolts, grouting of parts in position etc. and also including two coats of red oxide zinc chromate primer and two coats of synthetic enamel paint of approved colour, shade & brand etc. complete as per relevant IS standard or as per manufacturer's requirements or as directed by IOCL. All fitted & fixed complete as per the drawings and instructions of CONSULTANT/IOCL Engineer In charge.(Measurement for the payment shall be the area of clear shutter size ). Approx. area of each Rolling shutter is 3 m x 3.5 m. BI01010001010000000000000515BI0100001153 5 EA
39 39 MS grill : Supply & fixing of MS grill in 12x12 MS square bar or 25/5 flat , spacing will be 150 mm as per IOC specs including painting with one coat of synthetic enamel over one coat of primer. BI01010001010000000000000515BI0100001154 1000 KG
40 40 Exterior Paint: Providing and applying one coat of approved primer & two coats of Exterior Emulsion paint of Asian make (ACE Paint) or equivalent of approved shade to all external surfaces of cement plastered work or concrete including scaffolding, preparation of the surfaces as per manufacturers requirements, crack filling with approved filler material, curing etc. complete as per manufacturers specifications & as directed by CONSULTANT / IOCL Engineer in charge BI01010001010000000000000515BI0100001155 500 M2
41 41 Interior Paint: Providing & applying one coat of primer, one coat of putty and three coats of acrylic Emulson paint of approved shade & make, carrying out the work as per manufacturer specification including cleaning, internal surface preparation, staging/ scaffolding etc. complete and as directed by CONSULTANT / IOCL Engineer incharge BI01010001010000000000000515BI0100001156 500 M2
42 42 Design, engineering, manufacture/supply, fabrication, welding, installation, testing &\ncommissioning of slope elevator for elevating empty container/ buckets bags/ urea bags from ground level to the mezzanine floor. The item rates are inclusive of provision of roller coveyor at ground floor of suitable size, belt conveyor having rough top belt-nylon impregnated PVC with moulded rubber embedded cleats or metal conveyor. This item is also inclusive of Roller lagging material, Rollers, free rollers etc required at both the end. The entire structure should be of MS and to be painted as per the painting scheme given above. BI01010001010000000000000515BI0100001157 1 LS
43 43 Grid False Ceiling\n Providing & Fixing 15mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture pintone/cosmos / Hexa or equivalent of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38mm made from 0.33mm thick (minimum) sheet, spaced 1200mm centre to centre, and cross "T" of size 24x28mm made out of 0.33mm (Minimum) sheet, 1200mm long BI01010001010000000000000515BI0100001158 50 M2
44 44 160 mm dia UPVC rain water down take pipe Providing, supplying, clamping and fixing 150mm Dia (6 kg/sqcm) UPVC rain water down take pipes from terraces to the ground level including fittings & providing of all required accessories etc complete as per drawings BI01010001010000000000000515BI0100001159 250 Rmt
45 45 110 mm dia UPVC rain water down take pipe Same as above but 110 mm dia BI01010001010000000000000515BI0100001160 100 Rmt
46 46 Sanitary and Water Supply Fittings Note: All catalogue nos. referred in various items of sanitary fittings are as per Hindustan Sanitary ware catalogues\nWater Closet---- Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat lid with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40mm flush bend 20mm over flow pipe with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend. BI01010001010000000000000515BI0100001161 2 Nos
47 47 Providing and fixing in position white vitreous ‘Hindustan’ Parryware or other approved make flat back urinals small size 355 x 465 large size 400 x 610 consisting of the following and inclusive of making water and drain connections. \na) C.P. brass waste coupling.\nb) C.P. brass bottle trap with extension piece and wall flange.\nc) High Level 1st quality P.V.C. flushing cistern ‘Commander’ , ‘Champion’ or ‘Parryware’ ‘Slimline’ make with all accessories like C.I. or M.S. fixing brackets, overflow pipe, waste coupling, C.P. brass chain and handle, 15 dia C.P. brass angle stop cock and 10 dia C.P./P.V.C. connector pipe.\nd) Flush valve (push button and 0.53 GPF/2.0LPF.\ne) C.P. flush pipe with C.P. distribution arms and C.P. spreaders for set of one, two and three urinals.\nAll above items are required for 1 Set of Urinal BI01010001010000000000000515BI0100001162 2 Nos
48 48 Partition wall between Urinals Supplying & fixing granite partition 16 mm thick between urinals.(Size 1000x600) as per direction of IOCL/CONSULTANT Engineer in charge BI01010001010000000000000515BI0100001163 2 Nos
49 49 SW Pipes\nProviding, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : for 150 mm dia pipe.This also includes Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design for 150 mm SW Pipe BI01010001010000000000000515BI0100001164 5 Rmt
50 50 Providing and fixing CP brass bib cock : 15 mm dia. BI01010001010000000000000515BI0100001165 3 Nos
51 51 Providing and fixing CP brass Stop cock : for 15 mm dia. BI01010001010000000000000515BI0100001166 3 Nos
52 52 Providing and fixing G.I. Pipes--25mm BI01010001010000000000000515BI0100001167 25 Rmt
53 53 Providing and fixing G.I. Pipes---15mm BI01010001010000000000000515BI0100001168 30 Rmt
54 54 Providing and fixing G.I. Pipes---40mm BI01010001010000000000000515BI0100001169 20 Rmt
55 55 PIPE CONNECTION 25MM TO 40 MM BI01010001010000000000000515BI0100001170 4 Nos
56 56 PIPE CONNECTION 15MM TO 25 MM BI01010001010000000000000515BI0100001171 4 Nos
57 57 Wash Basins--460 dia circular or oval BI01010001010000000000000515BI0100001172 2 Nos
58 58 Toilet Paper Holder BI01010001010000000000000515BI0100001173 2 Nos
59 59 mirror 600x450 size BI01010001010000000000000515BI0100001174 2 Nos
60 60 Liquid Soap Container BI01010001010000000000000515BI0100001175 3 Nos
61 61 C.P. Towel Rail--20 mm dia 600 mm long BI01010001010000000000000515BI0100001176 3 Nos
62 62 Hand Jet Spray BI01010001010000000000000515BI0100001177 2 Nos
63 63 Providing and fixing in position 25 litres instant type water heater BI01010001010000000000000515BI0100001178 1 Nos
64 64 Towel Ring BI01010001010000000000000515BI0100001179 3 Nos
65 65 RO water purifier with storage of min. 5 lit water. Make Eureka forbes or Kent or equivalent. BI01010001010000000000000515BI0100001180 1 Nos
66 66 Water Cooler BI01010001010000000000000515BI0100001181 1 Nos
67 67 RCC inspection chamber size 900 x 450 and depth upto 600mm BI01010001010000000000000515BI0100001182 3 Nos
68 68 RCC conical manhole 1200 mm dia at bottom and 530 mm dia at top and depth of 1.5 mtr. BI01010001010000000000000515BI0100001183 1 Nos
69 69 Sintex or equivalent water tanks 5000 litre BI01010001010000000000000515BI0100001184 2 Nos
70 70 SW Trap--150 mm dia. BI01010001010000000000000515BI0100001185 4 Nos
71 71 Providing gola 75x75 mm in cement concrete 1:2:4 BI01010001010000000000000515BI0100001186 1 Nos
72 72 Making khurras 45 cm x45 cm with average min thickness of 5 cm cement concrete 1:2 :4 BI01010001010000000000000515BI0100001187 1 Nos
73 73 RCC Hume Pipes - 300 mm dia. R.C.C. pipe\nProviding and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty\n BI01010001010000000000000515BI0100001188 50 M
74 74 Providing and laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen BI01010001010000000000000515BI0100001189 10 M
75 75 Supply and fixing DB in steel sheet enclosure with 4-pole MCCB of breaking capacity 16 KA of 100Amp , as per specifications and direction of Engineer in Charge BI01010001010000000000000515BI0100001190 1 EA
76 76 MCB DISTRIBUTION BOARD INCLUSIVE OF 3- PHASE MCB Supply & fixing of MCB Distribution Board double door type inclusive of MCB, Three Phase, as per Approved Make of following types: (MCB - 10KA Breaking Capacity) 4 way DB with 63A FP RCBO, 300 mA sensitivity as incoming - 1No.& 6 to 16A SP as outgoing - 4 Nos. for each phase. BI01010001010000000000000515BI0100001191 1 EA
77 77 Supply & Laying horizontally and vertically of PVC/XLPE insulated cables of following sizes on cable trays, supported on steel structures, in ready made trenches and / or to pull-through pipes. The rates shall include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, etc, including transportation from supply store to the place of installation, unpacking and return the cable drums to site stores with all labour and materials as per the standard specifications, drawings and directions of Engineer-in-charge. BI01010001010000000000000515BI0100001192
78 77.01 3.5 C x 95 Sq. mm, 'A2XFY' cable with FRLS insulation BI01010001010000000000000515BI0100001193 500 M
79 77.02 3.5 C x 150 Sq. mm, 'A2XFY' cable with FRLS insulation BI01010001010000000000000515BI0100001194 500 M
80 77.03 4C x 25 Sq. mm, 'A2XFY' cable with FRLS insulation BI01010001010000000000000515BI0100001195 100 M
81 77.04 4C x 16 Sq. mm, 'A2XFY' cable with FRLS insulation BI01010001010000000000000515BI0100001196 10 M
82 77.05 3C x 2.5 Sq. mm, 'YWY' cable ( For Lighting Circuits) with FRLS insulation BI01010001010000000000000515BI0100001197 600 M
83 77.06 Power Cables: 650/1100V grade, XLPE insulated, Al/Cu. conductor armoured, extruded PVC inner sheathed & extruded FRLS PVC outer sheathed conforming to IS 7098 (Part 1).\n1C x 630 sq.mm A2XWaY BI01010001010000000000000515BI0100001198 750 M
84 78 Termination of PVC/XLPE insulated cables of different sizes and connection of the Leads including supply of weather proof double compression type cable glands and tinned copper lugs, including cutting / stripping of cable insulation, fixing of cable glands, crimping of the cable cores, marking with wire number ferrules, etc., including all labour and materials, as per standard specifications and cable drums to site stores with alllabour and materials as per the standard specifications, drawings and directions of Engineerin- charge. BI01010001010000000000000515BI0100001199
85 78.01 3 .5C x 95 Sq. mm, 'A2XFY' cable BI01010001010000000000000515BI0100001200 10 EA
86 78.02 3 .5C x 150 Sq. mm, 'A2XFY' cable BI01010001010000000000000515BI0100001201 10 EA
87 78.03 4C x 25 Sq. mm, 'A2XFY' cable BI01010001010000000000000515BI0100001202 6 EA
88 78.04 4C x 16 Sq. mm, 'A2XFY' cable BI01010001010000000000000515BI0100001203 2 EA
89 78.05 3C x 4 Sq. mm, 'YWY' cable BI01010001010000000000000515BI0100001204 40 EA
90 78.06 3C x 2.5 Sq. mm, 'YWY' cable BI01010001010000000000000515BI0100001205 120 EA
91 78.07 Industrial type double compression nickel plated brass cable gland, crimping type tinned copper lugs & termination/fixing of the same including supply of crimping type tinned copper lugs & PVC/XLPE cable hoods etc for the following cable sizes.\n1C X 630 A2XWaY BI01010001010000000000000515BI0100001206 4 EA
92 79 PERFORATED GI CABLE TRAY \nSupplying, fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and/or fix to steel/RCC columns, beams or any other structure members with MS suspenders, angles, channels, etc complete as per the direction of Engineer in charge. BI01010001010000000000000515BI0100001207
93 79.01 S/F/I Perforated GI trays of 150mm x 50mm x 2mm with bends, tees, cross members etc. as per BI01010001010000000000000515BI0100001208 100 M
94 79.02 S/F/I Perforated GI trays of 300mm x 50mm x 2mm with bends, tees, cross members etc. as per BI01010001010000000000000515BI0100001209 100 M
95 80 Supply,Installation, connection and testing of following lighting fixtures with suitable lamps and 'junction box (100mmx100mm) provided for point wiring, with lamps and suitable control gear box, 'including supply of all hardware like anchor fasteners, bolts, etc. required for installation, labour and 'materials as per standard specifications,drawings and directions of Engineer-in-charge. BI01010001010000000000000515BI0100001210
96 80.01 Industrial type high bay fixture suitable 120W LED lamp with integral Diver and glass cover with IP-54 class of protection,equivalent to Bajaj Catalogue no.-BJHFL120LED, 'catalogue no.-LH01-102-XXX-50-XXCrompton Catalogue no.:-LHB120CDL/60, Wipro BI01010001010000000000000515BI0100001211 45 EA
97 80.02 Industrial type surface mounted low bay type fixture suitable 90W LED lamp with integral Driver and IP-54 class of protection,equivalent to Bajaj Catalogue no.-BJHFL80LED, Crompton Catalogue no.:-LHB90CDL/61, Wipro catalogue no.- LH01-751-XXX-50-XX BI01010001010000000000000515BI0100001212 2 EA
98 80.03 120W LED Street light type fixture with integral driver suitable for IP-66 class of protection, equivalent to Bajaj'Catalogue no.-BRTFG120LED, Crompton Catalogue no.:-LSTN120CDL, Wipro catalogue 'no.-LR02-132-XXX-57-XX BI01010001010000000000000515BI0100001213 4 EA
99 81 Point wiring of the light points, ceiling fans, exhaust fans and power plug points from the lighting panels / control switch-boxes to the various light / fan / power plug points, using Medium duty 25mm dia PVC conduits and conduit fittings. Embedding the same in R.C.C. slabs, beams and walls in concealed manner, with 1100V grade FRLS type PVC insulated, colour coded, 2.5 / 4 sq.mm stranded copper conductorwires from approved makes for phase and neutral conductors and 1.5/2.5sq mm FRLS PVC Insulated copper wire forearth conductor The switch-boxes shall be embedded in wall and be made of 14SWG M.S. sheet with milky white / matching colour PVC covers with brass / rust-proof wall fixing screws, as approved by Engineer-in-charge. Switches, Setp type 'Electronic fan regulator, etc., on the same phase shallbe housed in the same switch-box. Switches shall be modular Piano type and from approved makes only. The mode of mesurement of wiring to the various points will as under. Each switch / MCB and the corresponding point shall be considered as one full point. Where one switch / MCB controls more than one point, the first point from the switch / MCB shall be considered as one full point and the other points in the group shall be considered as half point each. The wiring 'specified here will cover the circuits from switchbox/ lighting panel to the point outlets only. BI01010001010000000000000515BI0100001214
100 81.01 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. BI01010001010000000000000515BI0100001215 3 EA
101 81.02 Switch-box (excluding the supply of switch-box and switches) -- Half points ( From switchbox to switchbox) BI01010001010000000000000515BI0100001216 6 EA
102 81.03 Light points (with 2.5 sq.mm. cu. wire)---- Full points BI01010001010000000000000515BI0100001217 15 EA
103 81.04 Light points (with 2.5 sq.mm. cu. wire)------Half points BI01010001010000000000000515BI0100001218 5 EA
104 81.05 6 Amps. Plug Point(with 2.5 sq.mm. cu. wire) ---- Full points BI01010001010000000000000515BI0100001219 5 EA
105 81.06 6 Amps. Plug Point(with 2.5 sq.mm. cu. wire) ----- Half point (installed on switchbox, etc.) BI01010001010000000000000515BI0100001220 10 EA
106 81.07 6/16 Amps. Plug Point(with 4 sq.mm. cu. wire)---- Full points BI01010001010000000000000515BI0100001221 2 EA
107 81.08 6/16 Amps. Plug Point(with 4 sq.mm. cu. wire) ---- Half point BI01010001010000000000000515BI0100001222 2 EA
108 81.09 20A, 1 phase metalclad, polycarbonate body power plug point with DP ELMCB, plug and socket. The enclosure shall be 14SWG, M.S., milky white powder coated type. BI01010001010000000000000515BI0100001223 1 EA
109 82 Providing earthing with 80 mm dia, 3.8 M long GI (Heavy duty) perforated pipe as per IS:3043 (with latest amendment) including providing suitable earth bus for interconnection, providing a mixture of salt & charcoal, making earth pit chamber with chequered plate cover as per standard Drwng. etc. all complete as per specif. & direction of Engineer-In-charge. BI01010001010000000000000515BI0100001224 25 EA
110 83 Supply, installation, testing and commissioning of Hot Dipped G.I. (85 Micron thick) /Copper earthing loop / grid conductors of following sizes along the cable trenchs / cable trays / on the wall or structures / buried in ground (500mm depth) including excavation and back filling. Installation shall include the welding at joints and providing anti corrosive point (black butimine) at the welded portion and clamping using G.I. clamps and necessary hardware and materials as per standard drawings, specifications and directions of Engineer-in-charge. BI01010001010000000000000515BI0100001225
111 83.01 50 x 6 mm Hot dipped GI Strip. BI01010001010000000000000515BI0100001226 600 M
112 83.02 25 x 3 mm Hot Dipped G.I. Strip BI01010001010000000000000515BI0100001227 400 M
113 83.03 8 SWG Hot dipped G.I wire BI01010001010000000000000515BI0100001228 10 M
114 84 Supply and installation of 19 mm dia. Hot dipped G.I. (85 micron thick) lightning rod, 1200mm long, on & the highest point of the building / structure / chimney, etc., complete with all hardwares, labour and materials, as per standard drawing, specifications and directions of Engineer-in-charge BI01010001010000000000000515BI0100001229 1 EA
115 85 Supply and Installation of 200x200mm Power coated LA junction box fabricated from 2.5mm thick Sheet BI01010001010000000000000515BI0100001230 1 EA
116 86 Supply and installation of the following items including supply of necessary hardware, as per directions of Engineer-in-charge. BI01010001010000000000000515BI0100001231
117 86.01 Shock Treatment chart complete with frame and glass BI01010001010000000000000515BI0100001232 1 EA
118 86.02 First aid box BI01010001010000000000000515BI0100001233 1 EA
119 86.03 Sand buckets with stand (3 nos. buckets in a stand ) BI01010001010000000000000515BI0100001234 1 EA
120 86.04 Caution board a) 415 V Grade BI01010001010000000000000515BI0100001235 1 EA
121 86.05 Rubber hand gloves a) 415 V Grade BI01010001010000000000000515BI0100001236 1 EA
122 86.06 Supply and laying of 900 mm wide, 6 mm thick rubber floormat. BI01010001010000000000000515BI0100001237 2 M
123 86.07 Supply, Installation, testing, Commissioning of 600 mm dia. 240V, 1-Ph, AC heavy duty non flameproof, air circulator fan including starter, kaul, mounting bracket and other accessories. (Suitable for wall/structure mounting type). BI01010001010000000000000515BI0100001238 4 EA
124 87 Providing & fixing roof mounted solar tubular day lighting system of 750 mm dia (Tube) consisting (i) Light Collector of UV stabilized optical grade 2 mm clear transparent Polycarbonate dome with/without light management deflection panels. (ii) Factory made metal kerb with 2 seal system or UV stabilized moulded FRP roof kerb/adopter with water breaker arrangement and to be fixed onto metal sheet roof. The adoptor/kerb base should be flat, roof hugging and 100% matching with corrugation profile of base roof sheet. (iii) 1200 mm long anodised & PVD coated Light transfer tubing system of 2 mm thick (min) Aluminium alloy sheet without joint (iv) Double glazed diffuser of UV stabilized optical grade Polycarbonate material along with injection moulded ABS plastic or FRP ring. The diffuser can also be of semi clear 2 mm (min) prismatic Polycarbonate dome shape with one side plain and surface structure on one side. The design and shape of solar light shall be as per manufacturer's specifications and fixing of the whole system shall be completely leak proof. The solar day lighter shall provide at least 200 LUX at ground when installed at approx. 10 M height under clear sky conditions of ambient light of 1,00,000 LUX . BI01010001010000000000000515BI0100001239 10 EA
125 88 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50mm including strengthening with 2mm dia GI wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge using hot dipped galvanised wire of 4mm dia (The rate for civil works for excavation, brick masonry, PCC shall be paid separately) BI01010001010000000000000515BI0100001240 500 M2
126 89 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer in charge. BI01010001010000000000000515BI0100001241 250 H
127 90 Supply and fixing High Density Polymer Water pipe as per IS 4984, PE-63 grade,10 Kg/sqcm rating for borewell including all fittings etc.\n40mm dia HDPE pipe for borewell at a depth above 100m BI01010001010000000000000515BI0100001242 250 M
128 91 Part B. Addressable Smoke detection with Fire alarm panel \nWork under Part B has to be carryied out from the Approved Licensed Agencies of Directorate of Maharashtra Fire Services or similar Licensed Agencies for Fire services of Andhra Pradesh, having license for that work. BI01010001010000000000000515BI0100001243
129 92 ADDRESSABLE 4 LOOP FIRE DETECTION ALARM PANEL - Supply, installation, testing & commissioning of Microprocessor based Intelligent and electronically addressable, modular, expandable, networkable, fire Alarm system panel for combined smoke detection system at Warehouse as well as office buildings. The panel shall have 4 loop capacity having distributed memory, the panel shall have LCD display unit, The panel shall have 240 volts AC power supply, automatic battery charger, 24 volts, sealed lead acid maintenance free batteries sufficient for 48 hours normal working and then be capable of operating the system for 15 minutes during emergency condition, capacity to store minimum 1000 history events. Panel shall have minimum 32 bit micro-processor; each loop should support at least 99 detectors & 99 devices. (Make : Morley Honeywell, Schrack, or equivalent) BI01010001010000000000000515BI0100001244 1 EA
130 93 Active Repeater - Supply, Installation, Testing and Commissioning of Active Repeaters at three positions – Location In Charge Cabin, warehouse office and Security cabin. Functions – Silence, Mute, reset, Accept, Evacuate and test controls. Should be compatible with the main Fire Alarm panel. The repeater panel shall duplicate all the audio-visual annunciations initiated at the main panel. Battery back up along with the charging facility as that of main panel shall be provided for uninterrupted operation for atleast 8 hours. (Make : Morley Honeywell, Schrack, or equivalent) BI01010001010000000000000515BI0100001245 3 EA
131 94 Supply, Installation, testing & commissioning of Intelligent Analogue Addressable optical smoke Detector with floating sensitivity complete with all accessories like base, base box, etc. to be installed in Office, warehouse. interconnecting to loop cable complete as required. (Make : Morley Honeywell, Schrack, or equivalent) BI01010001010000000000000515BI0100001246 100 EA
132 95 Multi sensor type Smoke Detectors - Supply, Installation, Testing and Commissioning of Addressable intelligent Multi sensor type smoke detectors along with mounting base for panel and electric room. (Make : Morley Honeywell, Schrack, or equivalent) BI01010001010000000000000515BI0100001247 2 EA
133 96 Heat Detectors - Supply, Installation, Testing and Commissioning of Addressable Heat detectors along with mounting base for Pentry and Kitchen area. (Make : Morley Honeywell, Schrack, or equivalent) BI01010001010000000000000515BI0100001248 2 EA
134 97 Supply, Installation, testing & commissioning of Intelligent Analogue Addressable optical Beam Smoke Detector with Transmitter-Receiver & Reflector complete with all accessories like base, base box, etc. to be installed under / above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required. (Make : Morley Honeywell, Beam LRK, or equivalent) BI01010001010000000000000515BI0100001249 4 EA
135 98 Supply, Installation, testing & commissioning of Analogue Addressable strobes cum hoooters (conventional hooters + control module ) (Specification :- 110 cd light & 85 dB with adjustable DB) at different locations complete with all fixing accessories, etc under false ceiling roof, wall etc. interconnecting to loop cable complete as required. (Make : Morley Honeywell, Schrack, or equivalent) BI01010001010000000000000515BI0100001250 5 EA
136 99 Manual Call Points - Supply, Installation, Testing and Commissioning of addressable manual call points along with mounting back base complete with push button, enclosed in box with provision for cable or conduit coupling. The unit to be painted fire red outside, white inside. The unit shall be located near the exits/ staircase / strategic locations, should be wall mounted with break the galss/pull down cover type. The unit shall be addressable and communicate with main panel like other detectors. (Make : Morley Honeywell, Schrack, or equivalent) BI01010001010000000000000515BI0100001251 5 EA
137 100 Supply, Installation, Testing and Commissioning of Addressable intelligent type fault isolator module with LED indicator for isolating shorted, de-wired and loose circuits between two successive fault isolators with auto reset arrangement. (Make : Morley Honeywell, Schrack, or equivalent) BI01010001010000000000000515BI0100001252 5 EA
138 101 Response Indicators – Visual - Supply, Installation, Testing and Commissioning of visual indicators when the detector in that particular area/zone has been activated due to smoke of fire. The control room of the plant should be provided with separate visual alarm. (Make : Morley Honeywell, Schrack, or equivalent) BI01010001010000000000000515BI0100001253 4 EA
139 102 Response Indicator – Audio/Hooter - Supply, Installation, Testing and Commissioning of 1 Number of Hooter/ Siren for 1 km distance to be installed at the roof top of the plant. The alarm should be of horn cum strobe type and should be intelligent addressable with main panel. (Make : Morley Honeywell, Agni, Kheraj or equivalent) BI01010001010000000000000515BI0100001254 1 EA
140 103 Supply, Installation, Testing and Commissioning of Addressable Control Module. (Make : Morley Honeywell, Schrack, or equivalent) BI01010001010000000000000515BI0100001255 1 EA
141 104 Supply, Installation, Testing and Commissioning of Addressable Monitor Module. (Make : Morley Honeywell, Schrack, or equivalent) BI01010001010000000000000515BI0100001256 1 EA
142 105 Supply, Installation, Testing and Commissioning of LED base Emergency Exit signage with 3 hours battery backup etc. as required. (Make : ANG / Prolite / Autolite / MDS or equivalent). BI01010001010000000000000515BI0100001257 1 EA
143 106 Supply and Laying (Underground/on wall mounting/depending upon the location/path) along with proper protection of 2 Core x 1.5 Sqmm copper conductor FRLS armored red color cable along with clamping or on existing cable tray with clamping wherever required. The laying also includes the civil work wherever required. (Cable Make – Polycab or equivalent) BI01010001010000000000000515BI0100001258 1500 Mtr
144 107 Part C. Automatic Sprinkler System\nWork under Part B has to be carryied out from the Approved Licensed Agencies of Directorate of Maharashtra Fire Services or similar Licensed Agencies for Fire services of Andhra Pradesh, having license for that work. BI01010001010000000000000515BI0100001259
145 108 Supply, cutting, welded, Installation, testing & commissioning of class ‘C’ heavy duty G I pipe conforming to IS 1239 including fittings like internal threaded coupling suitable for sprinklers, elbows, tees, flanges, tapers, nuts bolts, gasket etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint (after applying etch primer as per specifications) of required shade of Fire Red complete as required. The item also includes fully welded 200 mm saddle/pad plate of same pipe in 1/4th perimeter at bottom over supports. Structural steel required for pipeline support or laying on wall / ceiling or columns etc shall be paid under separate item. The connection/welding job of Sprinkler system with main hydrant line will also be part of this item. BI01010001010000000000000515BI0100001260
146 108.01 150NB BI01010001010000000000000515BI0100001261 100 M
147 108.02 100NB BI01010001010000000000000515BI0100001262 200 M
148 108.03 80NB BI01010001010000000000000515BI0100001263 600 M
149 108.04 65NB BI01010001010000000000000515BI0100001264 500 M
150 108.05 50NB BI01010001010000000000000515BI0100001265 200 M
151 108.06 40NB BI01010001010000000000000515BI0100001266 600 M
152 108.07 32NB BI01010001010000000000000515BI0100001267 800 M
153 108.08 25NB BI01010001010000000000000515BI0100001268 800 M
154 108.09 Supply, cutting, laying GI pipe of 50 mm under Fire hydrant pipeline. BI01010001010000000000000515BI0100001269 10 M
155 109 Supply, Installation,Testing, Commissioning of Hand Wheel Operated Gate Valves rising spindle type of following sizes on the pipeline including supply and fixing 3mm thk CAF gaskets, studs/ nuts, flanges, making flanges joint etc of approved make for the following sizes as per specifications and site instructions. BI01010001010000000000000515BI0100001270
156 109.01 150 mm dia BI01010001010000000000000515BI0100001271 2 EA
157 109.02 100 mm dia BI01010001010000000000000515BI0100001272 2 EA
158 110 Supply, installation , testing and comissiong of 25 mm dia automatic air release valve with isolation valve, all acesories as required. BI01010001010000000000000515BI0100001273 4 EA
159 111 Supply, installation testing & commissioning of 150 mm dia cast iron Y Type strainer as requird. BI01010001010000000000000515BI0100001274 4 EA
160 112 Supply, Installation, testing & commissioning of butterfly valve of 150 mm dia confirming to IS 13095 PN 16 complete with CAF gasket, GI bolts, nuts washers etc as required. BI01010001010000000000000515BI0100001275 4 EA
161 113 Supply,Installation,Testing, Commissioning of Ball valves of 25 NB on the pipeline including Supply and fixing 3mm thk CAF gaskets, studs/ nuts etc of approved make for the following sizes as per specifications and site instructions. BI01010001010000000000000515BI0100001276 4 EA
162 114 Supply, Installation, testing & commissioning of Installation control (Alarm) valve of cast iron body and brass/ bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box ball valves, MS pipe of reqd. size, flanges, orifice plate, gasket etc. of size 150 mm dia as reqd. (UL listed / FM approved ) BI01010001010000000000000515BI0100001277 2 EA
163 115 Supply, installation, testing & commissioning of Flow Switch of size : 150 mm dia (UL listed / FM approved ) BI01010001010000000000000515BI0100001278 4 EA
164 116 Supply, installation, testing & commissioning of Swing type wall mounting Fire Hose Reel conforming to IS:884 consisting of Red colour Powder coated metallic drum, 20 mm dia inlet, 20 mm dia x 30 m long high pressure nylon braided Rubber Hose Pipe as per IS: 444 or Thermoplastic Hose Pipe as per IS: 12585 with isolating valve and Brass/Bronze nozzle with chrome plated and other required accessories complete in all respect with Nuts/bolts. The make may be of NewAge, SBJ, Safegaurd etc. BI01010001010000000000000515BI0100001279 8 EA
165 117 Supply, Installation, testing & commissioning of 20 mm size Pendent type sprinklers of brass/bronze with chrome plated of standard design having K-115, Quartzoid bulb of rating 680 C, Quick Response (QR) with other accessories as required. The sprinklers shall be UL listed or FM approved. Sprinkler to be fitted with Teflon Tape and must be leak proof/leak tight. The make may be of NewAge, HD Fire, Spraysafe, Tyco, Viking etc \nThe work shall be carried out in a warehouse at all heights upto 12 M. BI01010001010000000000000515BI0100001280 350 EA
166 118 Supply, Installation, testing & commissioning of 15 mm size Pendent type sprinklers of brass/bronze with chrome plated of standard design having K-80, Quartzoid bulb of rating 680 C, Standard Response (SR) with other accessories as required. The sprinklers shall be UL listed or FM approved. Sprinkler to be fitted with Teflon Tape and must be leak proof/leak tight. The make may be of NewAge, HD Fire, Spraysafe, Tyco, Viking etc \nThe work shall be carried out ina warehouse at all heights upto 6 M.\n BI01010001010000000000000515BI0100001281 100 EA
167 119 Supply, Installation, testing & commissioning of 15 mm size Sidewall type sprinklers of brass/bronze with chrome plated of standard design having K-80, Quartzoid bulb of rating 680 C, Standard Response (SR) with other accessories as required. The sprinklers shall be UL listed or FM approved. Sprinkler to be fitted with Teflon Tape and must be leak proof/leak tight. The make may be of NewAge, HD Fire, Spraysafe, Tyco, Viking etc \nThe work shall be carried out ina warehouse at all heights upto 6 M.\n BI01010001010000000000000515BI0100001282 10 EA
168 120 Supply, Installation, testing & commissioning of UL approved S S Braided flexible drops 25 mm dia capable to with stand maximum working pressure of 175 psi with all fittings for making connection to sprinklers and with the branches.1.2 mtr length BI01010001010000000000000515BI0100001283 15 EA
169 121 Supply, Installation, testing & commissioning of S.S. Rossate plates suiatble for below false ceiling sprinkler - for office area BI01010001010000000000000515BI0100001284 15 EA
170 122 Supply, installation, testing and commissioning of pressure gauge of 100 mm dia , 0-21 kg/sq.cm range with 15 mm dia stop cok valve, piping etc as required BI01010001010000000000000515BI0100001285 2 EA
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail