Addition/Alteration In Ngos Transit Facility At Nstl Visakhapatnam ., NSTL, Visakhapatnam.-Andhra Pradesh

Defence Research And Development Organisation -DRADO has published Addition/Alteration In Ngos Transit Facility At Nstl Visakhapatnam .. Submission Date for this Tender is 16-09-2019. Civil Work Tenders in NSTL, Visakhapatnam. Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

21551728
Addition/Alteration In Ngos Transit Facility At Nstl Visakhapatnam .
Open Tender
Indian
Andhra Pradesh
NSTL, Visakhapatnam.
16-09-2019

Tender Details

Addition/Alteration In Ngos Transit Facility At Nstl Visakhapatnam . , Subhead-I :Earth Work , Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1 . 5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms , Lift Up To 1 . 5 M , Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed , Within A Lead Of 50 M . , A ) All Kinds Of Soil . , Filling Available Excavated Earth ( Excluding Rock ) In Trenches , Plinth Sides Of Foundatios Etc , In Layers Not Exceeding 20Cm In Depth Consolidating Each Diposited Layer By Ramming And Watering , Lead Upto 50Meter And Lead Upto 1 . 5Meter , Supply Of Good Earth Of Approved Quality Obtained From Outside Md Land Filling In Layers Not Exceeding 20Cms Thick At All Heights And Depths In Foundations , Pits , Trenches , Sewer Lines Around Structures And Foundation Under Floors Other Places Including Dressing And Levelling Watering , Consolidation To Achieve Minimium Of 95% Proctor Density Etc . , Complete As Per Drawing Specifications , Payments Shall Be Made For The Quantity After Deducting The Voids . , Subhead-Ii :Anti Termite Treatment , Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified . , A ) Chlorpyriphos/ Lindane Emulsifiable Concentrate Of 20% , Diluting And Injecting Chemical Emulsion For Post-Constructional Anti-Termite Treatment ( Excluding The Cost Of Chemical Emulsion ) : , A ) Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2 . 25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc . , With Chlorpyriphos/ Lindane E . C . 20% With 1% Concentration . , B ) Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole , 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 ( 1 Cement : 2 Coarse Sand ) To Match The Existing Floor : , With Chlorpyriphos/ Lindane E . C . 20% With 1% Concentration . , Subhead-Iii :Plain And Reinforced Cement Concrete Work , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , B ) 1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40Mm Nominal Size ) . , A ) 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work , Using Cement Content As Per Approved Design Mix , Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering , Shuttering , Finishing And Reinforcement , Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate , Retard Setting Of Concrete , Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge . ( Note :-Cement Content Considered In This Item Is @ 330 Kg/Cum . Excess/Less Cement Used As Per Design Mix Is Payable/Recoverable Separately ) . , A ) All Works Upto Plinth Level , B ) All Works Above Plinth Level Upto Floor V Level , Add For Using Extra Cement In The Items Of Design Mix Over And Above The Specified Cement Content Therein . , Steel Reinforcement For R . C . C . Work Including Straightening , Cutting , Bending , Placing In Position And Binding All Complete Upto Plinth Level . , A ) Thermo-Mechanically Treated Bars Fe-500 , Centering And Shuttering Including Strutting , Propping Etc . And Removal Of Form For : , A ) Foundations , Footings , Bases Of Columns , Etc . For Mass Concrete , B ) Suspended Floors , Roofs , Landings , Balconies And Access Platform . , C ) Lintels , Beams , Plinth Beams , Girders , Bressumers And Cantilevers . , D ) Columns , Pillars , Piers , Abutments , Posts And Struts . , Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement :3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size , Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth . , Subhead-Iv: Stone Work & Brick Work , Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 ( 1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size ) Upto Plinth Level With : , A ) Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) , Brick Work With Common Burnt Clay F . P . S . ( Non Modular ) Bricks Of Class Designation 3 . 5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : , A ) Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) , Half Brick Masonry With Common Burnt Clay F . P . S . ( Non Modular ) Bricks Of Class Designation 3 . 5 In Superstructure Above Plinth Level Up To Floor V Level , Including Placing In Position 2 Nos 6Mm Dia . M . S . Bars At Every Third Course Of Half Brick Masonry , A ) Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Subhead - V: Plastering & Surface Treatment , 6Mm Thick Plastering In Cement Mortar 1:3 ( 1 Cement: 3 Fine Sand ) At All Levels And Locations For All Concrete Surfaces Of Columns , Beams , Walls , And Slabs Finished Smooth And Even Etc . , Complete . , 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix : , A ) 1:6 ( 1 Cement: 6 Fine Sand ) , 12 Mm Cement Plaster On Inside Side Of Single Or Half Brick Wall Of Mix : , 1:6 ( 1 Cement: 6 Fine Sand ) , 18Mm Thick Cement Plastering On External Surfaces Of Brick Or Concrete Surfaces In Two Layers Consisting Of 6Mm Thick Cement Mortar 1:3 ( 1 Cement: 3 Fine Sand ) Top Coat Mixed With Integral Water Proofing Compound Over A Base Coat 12Mm Thick Cement Mortar 1:5 ( 1 Cement : 5 Coarse Sand ) , Finished Sand Face Etc . , Complete At All Levels And Locations . , White Washing With Lime To Give An Even Shade : , A ) New Work ( Three Or More Coats ) , Providing And Applying Distempering With Oil Bound Washable Distemper Of Approved Brand AndManufacture To Give An Even Shade : , A ) New Work ( Two Or More Coats ) Over And Including Water Tinnable Priming Coat With Cement Primer , Finishing Walls With Textured Exterior Paint Of Required Shade : , A ) New Work ( Two Or More Coats Applied @ 3 . 28 Ltr/10 Sqm ) Over And Including Priming Coat Of Exterior Primer Applied @ 2 . 20Kg/ 10 Sqm , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Including Pink Or Grey Primer And Red Oxide Zinc Chromate Primer Of Wood/Steel Surace . , A ) Two Or More Coats On New Work , Sub Head - Vi: Flooring Work , Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300mm Or More ( Thickness To Be Specified By The Manufacturer ) , Of 1Stquality Conforming To Is : 15622 , Of Approved Make , In Colours White , Ivory , Grey , Fume Red Brown , Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) , Including Grouting The Joints With White Cementand Matching Pigments Etc . , Complete . 300X300mm Size . Made Of Nitco Company : Model Name Exotica/Maxima Series . Or , Made Of Somany Company : Model Name Trekker/Sprinkle Series . Or , Made Of Kajaria Company: Model Name Granila Crema/Beige/Almando Made Of Johnson Company Model No: Quartz Iv Or V Grip Ivory Or V Grip Brown Or Lenux Bg Or Delta Crema Or Equivalent . , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Of Size 200X300mm Or More And Shade Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours & Shades Of Any Size As Approved By Engineer-In-Charge In Skirting , Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) An

Key Value

Document Fees
INR 500 /-
EMD
INR 17860.0 /-
Tender Value
INR 8.93 Lakhs /-

BOQ Items

Name of Work: ADDITION/ ALTERATION IN NGO'S TRANSIT FACILITY AT NSTL VISAKHAPATNAM.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SUBHEAD-I :EARTH WORK 1
2 1.01 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1.01
3 1.02 a) All kinds of soil. 1.02 17 Cum
4 1.03 Filling available excavated earth (Excluding Rock) in trenches,Plinth sides of foundatios etc,in layers not exceeding 20cm in depth consolidating each diposited layer by ramming and watering,lead upto 50meter and lead upto 1.5meter 1.03 12 Cum
5 1.04 Supply of good earth of approved quality obtained from outside MD land filling in layers not exceeding 20cms thick at all heights and depths in foundations, pits, trenches, sewer lines around structures and foundation under floors other places including dressing and levelling watering, consolidation to achieve minimium of 95% proctor density etc., complete as per drawing specifications, payments shall be made for the quantity after deducting the voids. 1.04 8 Cum
6 1.05 SUBHEAD-II :ANTI TERMITE TREATMENT 1.05
7 1.06 Supplying chemical emulsion in sealed containers including delivery as specified. 1.06
8 1.07 a) Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 1.07 20 Lit
9 1.08 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 1.08
10 1.09 a) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. 1.09
11 1.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 1.1 13 RMT
12 1.11 b) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : 1.11
13 1.12 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 1.12 6 Sqm
14 1.13 SUBHEAD-III :PLAIN AND REINFORCED CEMENT CONCRETE WORK 1.13
15 1.14 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1.14
16 1.15 b) 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size). 1.15 3 Cum
17 1.16 a) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 1.16 1 Cum
18 1.17 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :-cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). 1.17
19 1.18 a) All works upto plinth level 1.18 5 Cum
20 1.19 b)All works above plinth level upto floor V level 1.19 10 Cum
21 1.2 Add for using extra cement in the items of design mix over and above the specified cement content therein. 1.2 2 Quintal
22 1.21 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. 1.21
23 1.22 a) Thermo-Mechanically Treated bars Fe-500 1.22 1191 Tonne
24 1.23 Centering and shuttering including strutting, propping etc. and removal of form for : 1.23
25 1.24 a) Foundations, footings, bases of columns, etc. for mass concrete 1.24 19 Sqm
26 1.25 b) Suspended floors, roofs, landings, balconies and access platform. 1.25 45 Sqm
27 1.26 c) Lintels, beams, plinth beams, girders, bressumers and cantilevers. 1.26 48 Sqm
28 1.27 d) Columns, Pillars, Piers, Abutments, Posts and Struts. 1.27 22 Sqm
29 1.28 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1.28 10 Sqm
30 1.29 SUBHEAD-IV: STONE WORK & BRICK WORK 1.29
31 1.3 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : 1.3
32 1.31 a) Cement mortar 1:6 (1 cement : 6 coarse sand) 1.31 3 Cum
33 1.32 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1.32
34 1.33 a) Cement mortar 1:6 (1 cement : 6 coarse sand) 1.33 12 Cum
35 1.34 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level,including placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry 1.34
36 1.35 a) Cement mortar 1:4 (1 cement : 4 coarse sand) 1.35 10 Sqm
37 1.36 SUBHEAD - V: PLASTERING & SURFACE TREATMENT 1.36
38 1.37 6mm thick plastering in cement mortar 1:3 (1 cement: 3 fine sand) at all levels and locations for all concrete surfaces of columns, beams,walls, and slabs finished smooth and even etc., complete. 1.37 38 Sqm
39 1.38 15 mm cement plaster on rough side of single or half brick wall of mix : 1.38
40 1.39 a) 1:6 (1 cement: 6 fine sand) 1.39 30 Sqm
41 1.4 12 mm cement plaster on inside side of single or half brick wall of mix : 1.4
42 1.41 1:6 (1 cement: 6 fine sand) 1.41 25 Sqm
43 1.42 18mm thick cement plastering on external surfaces of brick or concrete surfaces in two layers consisting of 6mm thick cement mortar 1:3 (1 cement: 3 fine sand) top coat mixed with integral water proofing compound over a base coat 12mm thick cement mortar 1:5 (1 cement : 5 coarse sand), finished sand face etc., complete at all levels and locations. 1.42 45 Sqm
44 1.43 White washing with lime to give an even shade : 1.43
45 1.44 a) New work (three or more coats) 1.44 38 Sqm
46 1.45 Providing and applying Distempering with oil bound washable distemper of approved brand and\nmanufacture to give an even shade : 1.45
47 1.46 a) New work (two or more coats) over and including water tinnable priming coat with cement primer 1.46 55 Sqm
48 1.47 Finishing walls with textured exterior paint of required shade : 1.47
49 1.48 a) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm 1.48 40 Sqm
50 1.49 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade including pink or Grey primer and red oxide zinc chromate primer of wood/steel surace. 1.49
51 1.5 a) Two or more coats on new work 1.5 10 Sqm
52 1.51 SUB HEAD - VI: FLOORING WORK 1.51
53 1.52 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), including grouting the joints with white cementand matching pigments etc., complete. 300x300mm Size.\nMade of NITCO Company : Model name Exotica/Maxima series.or,\nMade of SOMANY Company : Model name Trekker/Sprinkle series.or,\nMade of KAJARIA Company: Model Name Granila Crema/Beige/Almando Made of Johnson Company Model No: QUARTZ IV OR V GRIP IVORY OR V GRIP BROWN OR LENUX BG OR DELTA CREMA Or equivalent. 1.52 38 Sqm
54 1.53 Providing and fixing Ist quality ceramic glazed wall tiles of size 200x300mm or more and shade conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours & shades of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. Made of NITCO Company : Model name Suede Leather series.or,\nMade of SOMANY Company : Model name Somany Digital Series.or,\nMade of KAJARIA Company : Model name Mystic Beige & Beige Forte.Made of Johnson Company Model No : UNIFLOW DEEP OR UNIFORM BRIGHT OR SOBARO BRIGHT OR SOBARO DEEP Or equivalent. 1.53 60 Sqm
55 1.54 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 1.54
56 1.55 a) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble (area of slab over 0.5 Sqm) 1.55 4 Sqm
57 1.56 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 1.56 18 Sqm
58 1.57 SUB HEAD - VII : STEEL, ALUMINIUM AND WOOD WORKS 1.57
59 1.58 Providing and fixing powder coated aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to IS: 733 and IS: 1285, powder coated, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM/neoprene felt etc., Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, CP Brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge (Glazing and panelling to be paid for separately).The gap between the aluminium member and the masonary should be filled with approved sealant etc, complete. 1.58
60 1.59 a) For fixed portion with powder coated Aluminium (minimum thickness of powder coating 50 micron) 1.59 20 Kg
61 1.6 b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM/neoprene gasket required including fittings like handles , locking arrangement etc., with powder coated Aluminium (minimum thickness of powder coating 50 micron) 1.6 15 Kg
62 1.61 Providing and fixing glazing in aluminium door window, ventilator shutters and partitions etc., with EPDM/neoprene gasket etc.,complete as per the architectural drawings and the directions of Engineer-in-charge(Cost of aluminium snap beading shall be paid in basic item). 1.61
63 1.62 a) With float glass panes of 4.0 mm thickness (weight not less than 10.0 kg / sqm) 1.62 10 Sqm
64 1.63 c) With float glass panels of 5.50mm thickness (for doors) of Saint Gobin or equivalent. 1.63 8 Sqm
65 1.64 Supplying, fabricating and fixing of M.S. grills to windows & ventilators frames using MS flats, square rods all as per design etc., complete with a shop coat of primer. 1.64 30 Kg
66 1.65 Providing and fixing pressed steel door frame of size 105x60mm single rebate, manufactured from cold rolled mild steel sheet of 1.25mm thick in frames including hinges jamb, lock jamb bead, base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges, 2.5mm thick with mortar guards, lock strike plate and shock absorber as specified, filling with cement concrete 1:5:10(1 cement: 5 coarse sand: 10 graded stone aggregate 12mm nominal size) complete with a shop coat of primer after pre treatment of surface etc., complete all as specified(AGEW or approved equivalent make). 1.65 13 Rmt
67 1.66 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1.66
68 1.67 a) 35 mm thick 1.67 3 Sqm
69 1.68 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm x 45mm having single rebate of 32mm x 15mm to receive shutter of 30mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat . Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 1.68 21 Rmt
70 1.69 Providing and fixing 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels conforming to IS: 14856 including fixing to frames. 1.69 5 Sqm
71 1.7 Providing and fixing the following hardware fittings of approved make. 1.7
72 1.71 a) Aluminium handles, powder coated, ISI marked to required colour or shade with necessary screws etc., complete. 1.71
73 1.72 i) 125mm long handles. 1.72 4 Each
74 1.73 b) Rubber cleats of 50mm size 1.73 4 Each
75 1.74 c) Powder coated ISI marked tower bolt to required colour or shade with necessary screws etc., complete.for following sizes. 1.74
76 1.75 i) 200x10mm 1.75 4 Each
77 1.76 ii) 150x10mm 1.76 4 Each
78 1.77 d) Aluminium hanging floor door stopper ISI marked powder coated to required colour or shade with necessary screws etc., complete. 1.77
79 1.78 i) Single rubber stopper 1.78 4 Each
80 1.79 e) Provfiding & fixing Aldrop 300mm long with 16mm dia rod, required colour or shade with necessary screws etc., complete 1.79 4 Each
81 1.8 ii) Brass CP mortice lock six levers handles of make with necessary screws etc., complete for single door. 1.8 2 Each
82 1.81 f) Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete. 1.81 4 Each
83 1.82 SUB HEAD - VIII : ROOF WORK 1.82
84 1.83 Providing and laying integral cement based water proofing treatment including preparation of surface as requried for treatrment of roofs, balconies, terraces etc., consisting of following operations. 1.83 30 Sqm
85 1.84 a)Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixture with proprietory water proofing compound conforming to IS: 2645 over the RCC slab including cleaning the surface before treatment. 1.84
86 1.85 b) Laying cement concrete using broken bricks/brick bats 25mm to 100mm size with 50% cement mortar 1:5 (1 cement: 5 course sand) admixture with proprietary water proofing compound conforming to IS 2645 to required slope and treating similarly the adjoining walls upto 300mm height including rounding of junctions of walls and slabs. 1.85
87 1.86 c) After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS 2645. 1.86
88 1.87 d) Finishing the surfaces with 20mm thick jointless cement mortar of mix 1:4(1 cement 4 coarse sand ) admixed with proprietary water proofing compound to IS 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300x 300 mm square. 1.87
89 1.88 e)The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer in charg, with average thickness of 120mm and min thickness at khurra 65mm (Service guarantee shall be given for a period of 5 years from the date of completion. Any defects noticed during this period shall be rectified immediately at the risk and cost of contractor. Plan area only shall be measured for payment) 1.88
90 1.89 Providing and fixing PVC rain water down take pipe of 6kg/cm2 pressure or grade etc.,including necessary fittings like clamps, bends, shoes and adhesives etc., complete all as directed. 1.89
91 1.9 (i) 110mm dia 1.9 6 Rmt
92 1.91 SUB HEAD- IX :STRUCTURAL STEEL 1.91
93 1.92 Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 1.92
94 1.93 a) In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete 1.93 10 Kg
95 1.94 SUB HEAD- X :MISCELLANEOUS 1.94
96 1.95 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 1.95 1 Cum
97 1.96 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer -in -charge. 1.96 10 Sqm
98 1.97 Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : 1.97 1 Cum
99 1.98 SUB HEAD-XI:SANITARY SERVICES: 1.98
100 1.99 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Make: Hindware code sleek plus single flush star white with all fittings and fixtures/hindware / parryware/equivalent. 1.99
101 2 a)W.C. pan with ISI marked white solid plastic seat and lid 2 2 Each
102 2.01 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: Make: hindware / parryware/equivalent. 2.01
103 2.02 a) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 2.02 2 Each
104 2.03 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern Make: Hindware-60002 star white with 5 lit P.V.C automatic flush cistern. Make: Hindware-61002, star white 2.03 1 Each
105 2.04 Providing and fixing PTMT Bottle Trap for Wash basin and sink. 2.04
106 2.05 a) Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms Make: Jaquar Model no:ALD-769L 250x190 or equivalent. 2.05 4 Each
107 2.06 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. Make: Jaquar Model no:1135N or equivalent. 2.06 4 Each
108 2.07 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore . 2.07 4 Each
109 2.08 Providing,fitting and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore Make: Jaquar or Equivalent. 2.08 2 Each
110 2.09 Providing and fixing C.P. Brass Flush Valve 2.09 2 Each
111 2.1 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: Make: Jaquar or Equivalent. 2.1
112 2.11 a) White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 2.11 4 Each
113 2.12 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.SLS-WHT-0572 2.12 4 Each
114 2.13 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 2.13 4 Sqm
115 2.14 Providing and fixing toilet paper holder : C.P. brass 2.14 2 Each
116 2.15 Providing fixing C.P. brass towel rail of size 600 mm long fixed to wooden cleats with CP brass Screws complete as per instructions of the engineer-in-charge Make: Jaquar Model no: 1111NM or Equivalent. 2.15 4 Each
117 2.16 Providing and fixing CP health faucet for ablution at toilets in heavy quality with450mm Long Braided Hose with Two 15mm Nuts & Rubber Washers Without Nipple & CP angle cock of approved make -Make :- Jaguar or equivalent) \n 2.16 2 Each
118 2.17 Providing and fixing approved type SS coat hooks with concealed type screws of approved make. Item Details:- Make :- Jaguar or equivalent\n 2.17 4 Each
119 2.18 Providing & fixing sqare mouth S W Gully trap grade A complete with CI grating brick machinery chamber with water tight C I cover with frame of 300x300 mm (Size inside ) The weight of cover to be not less than 4.5 kg & frame to be not less than 2.70 kg as per standard design 2.18
120 2.19 100x100 mm size P type. 2.19 2 Each
121 2.2 Supplying, laying, jointing, testing and commissioning; uPVC(SWR) pipe (Type-B) as per IS : 13592/1992 including specials of best quality and approved make fixed to wall/floor including chasing, cutting, making the hole in walls/floors, cutting the pipes to the required size of length jointing the pipes and specials with suitable resin and testing etc.,complete all as specified and directed. (Specials at junctions must have access doors wherever required.) 2.2
122 2.21 a) 75 mm dia 2.21 3 Rmt
123 2.22 SUB HEAD-XII :INTERNAL WATER SUPPLY SERVICES: 2.22
124 2.23 Supplying laying, jointing testing painting, commissioning GI pipes of medium quality including specials of approved make Tata/Apola /Zenith or equivalent make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, testing, commissioning etc.,complete as specifed and directed. 2.23
125 2.24 a) 15mm. 2.24 15 RM
126 2.25 b) 20mm 2.25 10 RM
127 2.26 c) 25mm 2.26 10 RM
128 2.27 Supplying and fixing in position best quality and approved make heavy quality screws down gun metal gate valves with hand wheel of the following sizes fixed to service lines including testing, making good the leakages, if any etc., 2.27
129 2.28 a) 25mm 2.28 1 Each
130 2.29 SUB HEAD-XIII : INTERNAL ELECTRIFICATION 2.29
131 2.3 LIGHTS POINTS 2.3
132 2.31 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 2.31 16 Nos
133 2.32 SUB MAIN WIRING 2.32
134 2.33 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2.33
135 2.34 a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 2.34 60 Metre
136 2.35 b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire (For Geyser) 2.35 75 Metre
137 2.36 Supply, and installation of following FLP/wall Glass fixtures made out of Cast Aluminium alloy, toughened clear glass cemented info a bazel ring which is bolted to the body. And lamp holder with insulator on a bush plate and secured with screws. The body shall be finished with epoxy Grey slove enamelled outside and white inside.th efixtuyre shall be inclusive of all accessories including lamp but with/without control gear. 2.36
138 2.37 a) 15 Wsurface mounted downlight Crompton LCDEP-15-CDL 2.37 6 Nos
139 2.38 b) 10 W Mirror Light Make Crompton LCTLN-10-CDL 2.38 4 Nos
140 2.39 EXHAUST FANS 2.39
141 2.4 Suppy,Installation & Testing of following 900RPM exhaust fan suitable for single phase 240V,AC supply complete moter, louvrs mounting bracketse all accessories installation materials required. 2.4
142 2.41 a) 300 mm sweep. (Crompton Greaves EXHD 300-4-1) 2.41 4 Nos
143 2.42 CEILLING FAN 2.42
144 2.43 Supply,Installation & Testing of 1200 mm sweep ceilling fan suitable for single phase 204V, AC supply coplete with double ball bearing moters 300 mm down rod connector comlpete. 2.43
145 2.44 a) 1200 mm sweep. (Aura - Metallic ) 2.44 2 Nos
146 2.45 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2.45
147 2.46 a) 15/16 A switch 2.46 4 Nos
148 2.47 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 2.47
149 2.48 a) 4 Module (125mmX75mm) 2.48 4 Nos
150 2.49 Supply, Fixing, Installation, Testing and commissioning of 15 Ltr 4 Star Rated Water Gyzer, Including fixing accessories make RACOLD/Equivalent brand. 2.49 4 Nos
151 2.5 SUB HEAD-XIV : EXTERNAL WATER SUPPLY 2.5
152 2.51 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 2.51
153 2.52 50 mm dia nominal bore 2.52 5 Metre
154 2.53 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2.53
155 2.54 50 mm nominal bore 2.54 1 Mach
156 2.55 iv) Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow\npipes but without fittings and the base support for tank. 2.55 1000 Liter
157 2.56 SUB HEAD-XV : SEWAGE DISPOSAL SYSTEM. 2.56
158 2.57 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 2.57
159 2.58 100mm diameter 2.58 10 Rmt
160 2.59 150mm diametre 2.59 10 Rmt
161 2.6 Constructing brick masonry chamber for underground inspection chamber and bends with 35 class designation bricks in cement mortar 1:5 ( 1 cement : 5 fine sand ) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 2.6
162 2.61 a) Chamber size450X610mm and 450mm deep,With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 2.61 1 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail