Project Description
Tender For Operation & Comprehensive Maintenance Of Ems At Telephone Bhavan & S / Qtr, Latur ( Dist:Latur ) . , Operation & Comprehensive Maintenance Of The Following Electro- Mechanical Services As Per Specifications And Details Of Services Etc . Attached . A ) E . I . & Fans B ) Pumps C ) Compound-Lighting D ) Lightning Conductor E ) Sub-Station F ) E . A . Set G ) Fire Detection And Alarm , Fire Extinguishers , Fire Fighting . H ) Split A / C Unit , Window A / C Units , Water Coolers And Voltage Stabilizers I ) Package Ac Plant J ) Geysers , Room Heaters And Desert Coolers . K ) Avr L ) Lifts Note :1 ) Minimum Staff Required Is As Below . A ) Skilled Worker-00 No Per Day B ) Semi Skilled Worker-03 Nos Per Day C ) Unskilled Worker-01Nos . Per Day . 2 ) Only Operation Is Included In Respect Of Lift . , A ) I Year , B ) Ii Year , Servicing & Routine Maintenance ( B Check ) Of 380 Kva Capacity Of Dg Set Complete With Cleaning Of Air Cleaner Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , Check & Reset Injector Pressure , Check & Reset Injector Pump Timing , Retighten Cylinder Head Nuts , Adjust Engine Valve Clearance , Replacement Of Radiator Water By Fresh Distilled Water With Addition Of Coolant Additive Concentrate , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Check Air Piping , Belt Tensions I / C Cleaning & Dedusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc & Actual Load Testing Of Dg Set After Servicing Etc As Directed . [ B Check Once In 12 Months . Servicing Should Be Done From Authorised Dealer Only ] , Servicing & Routine Maintenance ( B Check ) Of 320 Kva Capacity Of Dg Set Complete With Cleaning Of Air Cleaner Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , Check & Reset Injector Pressure , Check & Reset Injector Pump Timing , Retighten Cylinder Head Nuts , Adjust Engine Valve Clearance , Replacement Of Radiator Water By Fresh Distilled Water With Addition Of Coolant Additive Concentrate , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Check Air Piping , Belt Tensions I / C Cleaning & Dedusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc & Actual Load Testing Of Dg Set After Servicing Etc As Directed . [ B Check Once In 12 Months . Servicing Should Be Done From Authorised Dealer Only ] , Supplying & Fixing Of Fully Charged 12 Volt , 180Ah Lead Acid Maintenance Free Battery For Starting Of 380 / 320 Kva Dg Set Complete With End Sockets Etc . As Reqd . Note- 1 ) The Battery ( S ) Of Each Dg Set Shall Be Replaced Once During Currency Of Contract & Agency Shall Consider Rebate For Old Battery While Quoting Of Rates . , Supplying & Fixing Fine Filters Having Efficiency Of 95% Efficiency Down To 10 Microns ( Eu-4 Class ) Suitable For 10Tr Package Ac Units . Note-The Filters Of Each Pkg Unit Shall Be Replaced At Once During Currency Of Contract . , Supplying & Fixing Pre Filters / Coarse Filters Having Efficiency Of 90% Efficiency Down To 20 Microns ( Eu-2 Class ) Suitable For 10 Tr Package Ac Units . Note-The Filters Of Each Pkg Unit Shall Be Replaced At Once During Currency Of Contract . , Abcd
BOQ
| Name of Work: Operation & Comprehensive Maintenance of EMS at Telephone Bhavan & S/qtr, Latur (Dist:Latur). | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Operation & comprehensive Maintenance of the following Electro- mechanical services as per specifications and details of services etc. attached.\na) E.I. & Fans\nb) Pumps\nc) Compound-Lighting\nd) Lightning conductor \ne) Sub-station\nf) E.A. Set\ng) Fire detection and Alarm, Fire Extinguishers, Fire Fighting.\nh) Split A/C unit, Window A/c Units, Water Coolers and Voltage Stabilizers \ni) Package AC Plant \nj) Geysers, Room heaters and Desert Coolers.\nk) AVR\nl) Lifts\n\nNOTE :1) Minimum staff required is as below.\n\na) Skilled Worker-00 No per Day b) Semi skilled Worker-03 Nos per Day c) Unskilled worker-01Nos. per Day.\n2) Only operation is included in respect of lift.\n\n\n | 1001 | ||
| 2 | 1.1 | a) I Year | 1002 | 12 | Months |
| 3 | 1.2 | b) II Year | 1003 | 12 | Months |
| 4 | 2 | Servicing & Routine maintenance (B check) of 380 KVA capacity of DG set complete with cleaning of Air cleaner element, Replacement of engine lube oil of proper grade (seal pack of reputed make), replacement of lube oil filter elements, replacement of fuel filter elements, Check & reset injector pressure, Check & reset injector pump timing, Retighten cylinder head nuts, Adjust engine valve clearance, Replacement of radiator water by fresh distilled water with addition of coolant additive concentrate, Cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, check air piping, belt tensions i/c cleaning & dedusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc & actual load testing of DG set after servicing etc as directed. \n[\"B\" check once in 12 months.Servicing should be done from authorised dealer only] | 1004 | 2 | Jobs |
| 5 | 3 | Servicing & Routine maintenance (B check) of 320 KVA capacity of DG set complete with cleaning of Air cleaner element, Replacement of engine lube oil of proper grade (seal pack of reputed make), replacement of lube oil filter elements, replacement of fuel filter elements, Check & reset injector pressure, Check & reset injector pump timing, Retighten cylinder head nuts, Adjust engine valve clearance, Replacement of radiator water by fresh distilled water with addition of coolant additive concentrate, Cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, check air piping, belt tensions i/c cleaning & dedusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc & actual load testing of DG set after servicing etc as directed.\n [\"B\" check once in 12 months.Servicing should be done from authorised dealer only] | 1005 | 2 | Jobs |
| 6 | 4 | Supplying & fixing of fully charged 12 volt,180AH lead acid Maintenance Free battery for starting of 380/320 KVA DG set complete with end sockets etc.as reqd.\nNOTE-\n1) The battery(s) of each DG set shall be replaced once during currency of contract & agency shall consider rebate for old battery while quoting of rates.\n | 1006 | 4 | Nos |
| 7 | 5 | Supplying & fixing Fine Filters having efficiency of 95% efficiency down to 10 microns (EU-4 class) suitable for 10TR Package AC units . \nNOTE-The Filters of each PKG unit shall be replaced at once during currency of contract.\n | 1007 | 49 | Sq. Ft |
| 8 | 6 | Supplying & fixing pre filters/coarse filters having efficiency of 90% efficiency down to 20 microns (EU-2 class) suitable for 10 TR Package AC units .\nNOTE-The Filters of each PKG unit shall be replaced at once during currency of contract.\n | 1008 | 49 | Sq. Ft |
| 9 | 7 | abcd | 1009 |