Military Engineer Services-MES has published Tender For Repair Maintenance To Ug Cable Oh Line God Insulators Lt Panel Apfc Panel Etc Including Preventive Maintenance To External Services At Nofra Noi Mo Goa Under Ge Gomantak. Submission Date for this Tender is 12-09-2019. Power Factor Panel Tenders in CWE NAVY VASCO Goa. Bidders can get complete Tender details and download the document.
Name of Work: REPAIR/MAINTENANCE TO UG CABLE, OH LINE, GOD, INSULATORS, LT PANEL, APFC PANEL ETC INCLUDING PREVENTIVE MAINTENANCE TO EXTERNAL SERVICES AT NOFRA, NOI, MO GOA UNDER GE GOMANTAK VASCO | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | M&L for taking down UG cable of any size all as specified and as directed.\nNote : Excavation shall be measured and paid separately. | 1000 | RM | |
2 | 2 | Excavation in trenches not exceeding 1.5 m width and not exceeding 1.5m in depth getting out in hard/dense soil all as specified and as directed. | 77.13 | Cum | |
3 | 3 | Excavation in trenches not exceeding 1.5 m width and not exceeding 1.5 in depth getting out soft disintegrated rock all as specified and as directed. | 92.21 | Cum | |
4 | 4 | M & L for sand cushion in trenches for cable protection all as directed and as specified.\nNote:-Punned thickness of sand shall be measured and paid. | 66.29 | Cum | |
5 | 5 | Supply and lay PCC cable cover class LV type I flat size 250mm x150mmx40mm with ISI mark all as specified and as directed. | 5100 | Each | |
6 | 6 | Supply and lay PCC cable cover class HV, type 1, flat size 300mm x 180mm x 40mm with ISI mark all as specified and as directed. | 400 | Each | |
7 | 7 | Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil/ soft disintegrated rock all as specified and as directed. | 85.09 | Cum | |
8 | 8 | Removal of surplus soil to a distance not exceeding 50 m and depositing where directed all as specified and as directed. | 84.25 | Cum | |
9 | 9 | Supply and laying HT XLPE cable insulated , screened, PVC bedded , galvanized steel strip armoured, electric power cable (Heavy duty) with aluminium conductor, cross sectional area 95 Sq mm 3 core 11KV grade, including dismantling of existing cable all as specified and as directed. | 80 | RM | |
10 | 10 | Supply & fixing UG LT cable XLPE insulated armoured heavy duty 1100 volts grade(Earthed) with aluminium conductor multi standarded including centre gland, lugs, jointing materials etc laid in trenches or fixed it to wall all as specified and as directed for following sizes:- | |||
11 | 10.1 | (a) 25 Sq mm 3.5 Core | 150 | RM | |
12 | 10.2 | (b) 35 Sq mm 3.5 Core | 200 | RM | |
13 | 10.3 | (c) 50 Sq mm 3.5 Core | 150 | RM | |
14 | 10.4 | (d) 70 Sq mm 3.5 Core | 150 | RM | |
15 | 10.5 | (e) 95 Sq mm 3.5 Core | 150 | RM | |
16 | 10.6 | (f) 120 Sq mm 3.5 Core | 100 | RM | |
17 | 10.7 | (g) 150 Sq mm 3.5 Core | 100 | RM | |
18 | 11 | M&L for fixing GI tubing 40mm dia light grade use for the protection of cable all as specified and as directed. | 24 | RM | |
19 | 12 | M&L for fixing GI tubing 50 mm dia light grade use for the protection of cable all as specified and as directed. | 12 | RM | |
20 | 13 | M&L for fixing GI tubing 80mm dia light grade use for the protection of cable all as specified and as directed. | 12 | RM | |
21 | 14 | M & L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sq mm including dismantling old burnt cable joint termination all as specified and as directed. | 2 | Job | |
22 | 15 | M & L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sq mm including dismantling old burnt cable joint termination all as specified and as directed. | 2 | Job | |
23 | 16 | M & L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sq mm including dismantling old burnt cable joint termination all as specified and as directed. | 1 | Job | |
24 | 17 | M & L for cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm including dismantling old burnt cable joint termination all as specified and as directed. | 2 | Job | |
25 | 18 | S & F in repair MCCB 415V 3 phase 50 HZ 4 pole 63 Amps breaking capacity 16 KA all as specified and as directed. | 1 | Each | |
26 | 19 | S & F in repair MCCB 415V 3 phase 50 HZ 4 pole 100 Amps breaking capacity 16 KA all as specified and as directed | 1 | Each | |
27 | 20 | S & F in repair MCCB 415V 3 phase 50 HZ 4 pole 200 Amps breaking capacity 25 KA all as specified and as directed . | 1 | Each | |
28 | 21 | S & F in repair MCCB 415V 3 phase 50 HZ 4 pole 250 Amps breaking capacity 25 KA all as specified and as directed | 1 | Each | |
29 | 22 | Material and labour for repairs to existing damaged jumper, over head conductors and testing of insulators, lightning arrestor, GOD, DO fuse, repairs to HT/LT cables insulator damaged than excavation work carry out and looping cable out and fixing to OH conductor with proper insulation, including testing of cable after jointing all as specified and as directed\nNote :\n(a) The quoted rates shall inlcude for minor items such as HT fuse wire, conductor wire for jointing of jumper up to 1.5 meter length, insulation tap, excavation work involved for looping cable only, transportation & ladder etc.\n(b) Contractor shall arrange electrician/labour within 1 Hrs to repairing of damaged jumper/over head conductor.\n(c) If contractor are failed to attend the complaints in time necessary penalty charges will be recovered. | 15 | Each \n Job | |
30 | 23 | M&L for repair to Gang Operated Air Break switches, 11 KV, Current capacity 200 Amps by replacing following spares all as specified and as directed | |||
31 | 23.1 | (a) Moving male contact blades Brass. | 3 | Each | |
32 | 23.2 | (b) Fixed female contact jaw Brass. | 3 | Each | |
33 | 23.3 | (c) Tinned copper flexible jumper | 3 | Each | |
34 | 23.4 | (d) MS Jumper carrier | 3 | Each | |
35 | 23.5 | (e) Back connector plate | 3 | Each | |
36 | 24 | M & L for Heavy gang operated triple pole mechanically operated air break on load disconnecting switch each pole consists of galvanized iron base HT 11KV with polymer insulators per phase non ferrous knife and spring loaded contact GI pipe of adequate length for operation from ground level and operating handle complete in both OFF and ON position capacity 11 KV 200 Amps including taking down old one all as specified and as directed | 4 | Each \nSet | |
37 | 25 | M & L for 11 KV Heavy Drop Out Fuse complete in each pole consist of galvanized iron base HT 11KV with polymer insulators including taking down old one all as specified and as directed. | 4 | Each \nSet | |
38 | 26 | M&L for HT 11 KV Disc type insulator with hardware, single disc assembly, polymeric insulator, vitreous145mm high and 255 mm dia and socket type, including taking down old unserviceable all as specified and as directed | 12 | Each | |
39 | 27 | S&F for Pin type polymer insulator including one galvanized mild steel spindle two GI washers and one GI iron nut 150mm height, 150mm dia for 11 KV grade including dismantling the old U/S insulator all as specified and as directed | 12 | Each | |
40 | 28 | S & F Lightning arrestor HT 11000 KV pole mounting with polymeric insulator complete with all fittings transmission class nominal discharge current up to 65 KA including removing the defective one complete all as specified and as directed. | 6 | Each | |
41 | 29 | S&F Electrical Insulating mat blue in colour confirming IS:15652-2006 of size 2m x 1m x 2.5 mm thick complete all as specified and as directed. | 2 | Each | |
42 | 30 | M & L for preparation of old painted surface of electric pole by removing all dirt, dust, etc and painting complete surface including connected accessories with one coat of Apex emulsion paint and aluminium paint of approved colour including cross arms/bracing support on poles and writing of pole Nos etc all as specified and as directed for following pole:- | |||
43 | 30.1 | (a) HT concrete pole of any length | 50 | Each \nJob | |
44 | 30.2 | (b) LT concreate pole of any length | 300 | Each \nJob | |
45 | 30.3 | (c ) LT steel tubular pole of any length | 10 | Each \nJob | |
46 | 31 | M & L for preparation of old painted surface of fencing, gate and angle iron with connected accessories along MES installation by removing all old paint, dirt, dust, etc and painting complete surface of installation with one coat of synthetic enamel paint of approved colour and foundation/platform of installation painting with one coat Apex emulsion paint including writing of identification etc all as specified and as directed. | 6 | Each \nJob | |
47 | 32 | M & L for preparation of old painted surface of Feeder Pillar box/LT Panel by removing all dirt, dust, etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including writing of identification etc all as specified and as directed | 10 | Each \nJob | |
48 | 33 | M & L for cutting and removing grass, vegetation bushes etc from surrounding E/M installation and removing all rubbish to a distance not exceeding 50 m all as specified and as directed | 500 | Sqm | |
49 | 34 | M & L for trimming trees, vegetation bushes etc from bellow the over head line and removing all rubbish to a distance 1.5 meter both sides of the over head line all as specified and as directed | 60 | Each \nJob | |
50 | 35 | M & L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate for repair of earth pit, cable duct PCC near GOD and transformer etc all as specified and as directed | 3 | Cum | |
51 | 36 | M & L for filling and spreading aggregate using 40 mm grade trap stone aggregate around 4 pole , 2 pole structure and transformer etc all as specified and as directed | 15 | Cum | |
52 | 37 | M&L for dismantling old cross arms MS clamp and angle from LT/HT pole all as specified and as directed | 3 | Qtl | |
53 | 38 | M&L for cross arm bracing support to clamps and back plate fabricated from structural steel section like angles channels flat etc including nuts bolts and washers welding bending cold or hot drilling holes for bolts if any shape and size and including applying two coats of aluminium paint over one coat of red oxide primer all as specified and as directed | 3 | Qtl | |
54 | 39 | Supply and installation of LT panel 'KIOSK type' cubical, weather, dust and vermin proof (out door type) CRPI approved suitable for operation on 1100 volts 3 phase, 4wire, 50 HZ AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3mm thick CRCA steel sheet as suitable size having opening and locking arrangement both from front and rear side with cable tray of size not less than 20cm including copper bus bar strip size 50x6 mm, 04 Nos. fixing on angle iron size of 50 x 50 x 6mm including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories:- | 1 | Each | |
55 | 39.1 | (i) MCCB 400 Amps 4 Pole 50 KA - 01 No (Incoming)\n(ii) MCCB 100 Amps 4 pole 30 kA - 04 Nos (Outgoing)\n(iii) S&F multi function digital meter with LCD display incl CT having CTR 50/5 (Parameters : V, A, F, PF, kW, kVA, KWh) - 01 No\n(iv) Selector Switches for Voltage and ampere - 02 No\n(vii) Indicators with neon lamp with RYB shade, 240 volts 50 c/s of suitable capacity resistance - 01 set | |||
56 | 40 | Material & Labour for Feeder Pillar Box of suitable size made out of 3 mm MS Sheet, powder coated, having insulated Bus Bar copper strip 50x3mm with colour code, mounted on angle iron frame of angle size 50x50x6mm, grouted on ground using PCC 1:3:6, door opening on front and back, necessary holes on bus bar for connecting the Cable including MCCB 200 Amps, 4 pole, 25KA breaking capacity as incoming (one no) & MCCB 100 Amps, 4 pole, 25KA breaking capacity 2 Nos as outgoing, multifunction digital meter with LCD display incl CT having CTR 50/5 (Parameters : V, A, F, PF, kW, kVA, KWh), Selector switch for voltage and ampere etc all as specified and as directed | 1 | Each | |
57 | 41 | S & F Volt meter digital panel mounting type of size 96 mm x 96 mm range 0 to 500 Volts AC all as specified and as directed. | 2 | Each | |
58 | 42 | S & F Ammeter panel mounting type of size 96 mm x 96 mm range 0 to 200 Amps with CT coil all as specified and as directed. | 2 | Each | |
59 | 43 | S & F Neon type indicator lamp switch by various colour 230 V AC suitable size to match the existing complete all as specified and as directed. | 2 | Set of\n three | |
60 | 44 | S & F Selector switch suitable for volt meter completed all as specified and as directed. | 4 | Each | |
61 | 45 | S & F Capacitor metalized poly propylene heavy duty extended life of capacity 5 KVAR for non linear load for 3 phase 440 V & 50 Hz system for permissible non-linear load all as specified and as directed. | 2 | Each | |
62 | 46 | S & F Capacitor metalized poly propylene heavy duty extended life of capacity 7.5 KVAR for non linear load for 3 phase 440 V & 50 Hz system for permissible non-linear load all as specified and as directed. | 2 | Each | |
63 | 47 | S & F Capacitor metalized poly propylene heavy duty extended life of capacity 10 KVAR for non linear load for 3 phase 440 V & 50 Hz system for permissible non-linear load all as specified and as directed. | 2 | Each | |
64 | 48 | S & F Capacitor metalized poly propylene heavy duty extended life of capacity 15 KVAR for non linear load for 3 phase 440 V & 50 Hz system for permissible non-linear load all as specified and as directed. | 2 | Each | |
65 | 49 | S & F Contactor MNX 40, Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1, Aux. Contacts 2 NO + 2 NC all as specified and as directed.\n Make: L&T type MNX 40 or equivalent as per Appendix 'B'. | 2 | Each | |
66 | 50 | Supply and fixing in repair 7 stage APFC relay, CT secondary 5 Amps, 415V, microprocessor based with programmable sequence controller, fault indicator, power factor indicator, power factor indicator complete all as specified and as directed. | 1 | Each | |
67 | 51 | Supply and apply petroleum jelly on GOD after removing carbon, dust etc complete all as specified and as directed | 4 | Kg | |
68 | 52 | Dismantling of ACSR conductor of any size from pole all as specified and as directed. | 1 | Qtl | |
69 | 53 | M&L for aluminium conductor steel wire reinforced (ACSR) fixed as over head line incl lighting through pole and on insulator with aluminium binding wire and including jumpers all as specified and as directed. | 1 | Qtl |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail