Communications and Information Technology  Government Departments Closing in 0 days TDR #21470433

Providing Of Electrical Installation Fans Mv Panel Earthing System Pkg Work At Air Force Station Nal 2 Distt Pdg Ei Fans Mv Panel Earthing System Precision Ac Pkg Work Fd System And Acd Cctv Camera Lighting Protection System In Proposed Refurbished

Issued by Government Departments · Bikaner, Rajasthan
Tender Value
3.59 Lakhs
Estimated cost
Bid Submission
26 Aug 2019
0 days left
EMD
7183
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bikaner → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Providing Of Electrical Installation Fans Mv Panel Earthing System Pkg Work At Air Force Station Nal 2 Distt Pdg Ei Fans Mv Panel Earthing System Precision Ac Pkg Work Fd System And Acd Cctv Camera Lighting Protection System In Proposed Refurbished Nfs Air Force Station At Nal2 Distt Bikaner Sh Pitc Of Addressable Fd And Fa System , Fire Alarm Control Panel ( Facp ) : Sitc Of Ul / Ulc / En 54 / Ce Listed Analogue Addressable Micro Processor Controlled , Standalone Main Fire Alarm Control Panel Having 1 Loop ( 1 Loop Card ) ( With Minimum 99 Detectors / 99 Devices Capacity Per Loop Card ) With Lcd Display , Capable Of Being Networked To The Central Monitoring System To Monitor And Integrate With Other Panels Such As Access Control System Along With Accessories Like Detectors , Lcps , Hooters , Control Modules , Monitor Modules Fault Isolation Modules , Response Indicators , Fire / Fault Indicators , Audio-Visual Signals , Central Processing Units , Complete With Lcd Display , Zone Indicating Leds , Having Multiple Access Levels , Event History File In Non-Volatile Memory ( Eeprom ) As Per The Detailed Specification , Complete With Psu , Battery Backup Along With Charger For 24 Hours In Non-Alarm Condition And 30 Minutes In Alarm Condition Etc . As Required For Each Panel . [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , Addressable Multisensor Detector: Supply , Installation , Testing And Commissioning Of Addressable Analogue Multisensor / Multicriteria Type , Ul / Ulc / En 54 / Ce Listed Photo Cum Thermal Detectors With Solid State Design , Indicating Led , Mounting Base , Mounting Bracket Etc . Base Box , Loop In & Loop Out Gland As Per Requirement And Detailed Specification As Per Following Positions . [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , A ) On Visible False Ceiling , B ) Above False / True Ceiling ( Base Box Is To Be Used ) , C ) Below False Flooring I / C S / F Of Ms Tripod ) , Addressable Heat Detector: Supply , Installation , Testing And Commissioning Of Addressable Analogue Type , Ul / Ulc / En 54 / Ce Listed Heat Detector Rate Of Rise Type With Solid State Design , Indicating Led , Mounting Base , Mounting Bracket Etc . Base Box , Loop In & Loop Out Gland As Per Requirement And Detailed Specification As Per Following Positions . [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , Addressable Control Modules: Supply Installation Testing And Commissioning Of Ul / Ulc / En 54 / Ce Listed , Addressable Control Module Complete With Junction Box Etc . For Control Options For Hooters & For Other Control Options Like Pa Evacuation , Access Doors Opening , Package Ac Trip Etc . In Case Of Emergency , As Required . [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , Addressable Monitoring Modules: Supply Installation Testing And Commissioning Of Ul / Ulc / En 54 / Ce Listed Addressable Monitoring Modules Complete With Junction Box Etc . To Monitor Status Of Other Systems Etc . As Required . [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , Manual Call Point: Supply Installation Testing And Commissioning Of Ul / Ulc / En 54 / Ce Listed Manual Call Points With No / Nc Contacts Slim Type With Pull Type / Break Glass With Reset Lock & Key Arrangement Suitable For Addressable Function [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , Electronic Hooter Cum Strobe: Supply Installation Testing And Commissioning Of Ul / Ulc / En 54 / Ce Listed Hooter Having Three Distinct Sounds With Addressable Relay Module And Strobe Light With Minimum 85 Db From 1 . 0 Mtr Distance Etc . As Required . [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , Fault Isolator Module: Supply Installation Testing And Commissioning Of Ul / Ulc / En 54 / Ce Listed Fault Isolation Module To Electrically Isolate Different Sections Of Detector Loops ( For Every 20 Detectors / Devices ) As Per Detailed Specifications . Etc . As Required . [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , Response Indicator: Response Indicator: Supply Installation Testing And Commissioning Of Response Indicator Having Twin Leds For Mounting On False Ceiling / Wall At The Entries Of The Cabin For Indicating The Operation Of Detectors In The Above False Ceiling / Below False Flooring Detectors Etc . As Required . [ Make: M / S . Agni Instruments / Agni Devices / Aruna Agencies / Carmel Sensor / Ravel Elect . / Honeywell Essar / Notifier / Navin Systems ] , Supplying And Fixing Of 25Mm Dia Flexible Metalic Conduit I / C End Termination Complete Etc As Reqd . , Supply , Installation Laying & Commissioning Of Copper Cable In Existing Conduit / On Tray / Surface Including Cable Laying Hardware Suitable For Fas With Red Colour Outer Sheath ( 2 C X 1 . 5 Sq . Mm Ywy Frls Shielded Armored Cable Including End Terminations In Red Colour . ) , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor , Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required , ( A ) 2 X 1 . 5 Sq . Mm , Supplying And Fixing Of 4 . 5Kg Capacity Co2 ( Carbon Dioxide ) Type Fire Extinguisher Confirming To Is:15683 And Cylinders Duly Charged Complete With 1Mtr Long Hose Pipe & Horn And Other Accessories Commissioning Etc . Complete As Required . , Supplying And Fixing Of 5 Kg Capacity Dry Chemical Powder Type Fire Extingusher Complete With Hose Pipe Duly Charged Ready To Use Etc . Complete As Required .

BOQ

Name of Work:Providing E.I & Fans, MV Panel, Earthing Sysytem Precision AC Packages Work, Addressable FD & FA System, ACD & CCTV Camera and Lighting Protection System in proposed refurbished NFS (Priority-II Package II) Air Force Station at NAL-2,Distt. Bikaner(SH-: PITC of addressable FD & FA system).
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Fire Alarm Control Panel (FACP): SITC of UL/ ULC/ EN 54/ CE listed Analogue addressable micro Processor controlled, Standalone Main Fire Alarm Control Panel having 1 loop (1 Loop Card) (with minimum 99 detectors/ 99 devices capacity per loop card ) with LCD display , capable of being networked to the central monitoring System to monitor and integrate with other panels such as Access control System along with accessories like detectors, LCP's, hooters, control modules, monitor modules Fault Isolation Modules, response indicators, fire/fault indicators, audio-visual signals, central processing units, complete with LCD display, zone indicating LEDs, having multiple access levels, event history file in non-volatile memory (EEPROM) as per the detailed specification, complete with PSU, Battery backup along with charger for 24 hours in non-alarm condition and 30 minutes in alarm condition etc. as required for each panel. [Make: M/s. Honeywell (Notifier/ system sensor/ firelite/morley)/ Kidde/ UTC Fire & security ( GST/ Edward)/ Siemens Fire Finder/ Bosch]1No.
22Addressable MultiSensor Detector: Supply, Installation, Testing and Commissioning of Addressable analogue MULTISENSOR / MULTICRITERIA type, UL/ULC/EN 54/CE Listed photo cum thermal detectors with solid state design, indicating LED, mounting base, mounting bracket etc. base box, loop in & loop out gland as per requirement and detailed specification as per following positions. [Make: M/s. Honeywell (Notifier/ system sensor/ firelite/morley)/ Kidde/ UTC Fire & security ( GST/ Edward)/ Siemens Fire Finder/ Bosch]
32.01a) On Visible False Ceiling8Nos
42.02b) Above False/ True Ceiling (Base Box is to be Used)17Nos
52.03c) Below False Flooring i/c S/F of MS tripod)12Nos
63Addressable Heat Detector: Supply, Installation, Testing and Commissioning of Addressable analogue type, UL/ ULC/ EN 54/ CE listed heat detector rate of rise type with solid state design, indicating LED, mounting base, mounting bracket etc. base box, loop in & loop out gland as per requirement and detailed specification as per following positions. [Make: M/s. Honeywell (Notifier/ system sensor/ firelite/ morley)/ Kidde/ UTC Fire & security ( GST/ Edward)/ Siemens Fire Finder/ Bosch]23Nos
74Addressable control modules: Supply Installation Testing and Commissioning of UL/ ULC/ EN 54/ CE Listed, Addressable control module complete with junction box etc. for control options for Hooters & for other control options like PA evacuation, Access Doors opening, Package AC trip etc. in case of emergency, as required. [Make: M/s. Honeywell (Notifier/ system sensor/ firelite/ morley)/ Kidde/ UTC Fire & security ( GST/ Edward)/ Siemens Fire Finder/ Bosch]11Nos
85Addressable monitoring modules: Supply Installation Testing and Commissioning of UL/ULC/EN 54/CE Listed Addressable monitoring modules complete with junction box etc. to monitor status of other systems etc. as required. [Make: M/s. Honeywell (Notifier/ system sensor/ firelite/ morley)/ Kidde/ UTC Fire & security ( GST/ Edward)/ Siemens Fire Finder/ Bosch]11Nos
96Manual Call Point: Supply Installation Testing and Commissioning of UL/ULC/EN 54/CE Listed Manual call points with NO/ NC contacts slim type with Pull type/ break glass with Reset Lock & Key arrangement suitable for addressable function [Make: M/s. Honeywell (Notifier/ system sensor/ firelite/ morley)/ Kidde/ UTC Fire & security (GST/ Edward)/ Siemens Fire Finder/ Bosch]1014No
107Electronic Hooter Cum Strobe: Supply Installation Testing and Commissioning of UL/ ULC/ EN 54/ CE listed Hooter having three distinct sounds with addressable relay module and strobe light with minimum 85 db from 1.0 Mtr distance etc. as required. [Make: M/s. Honeywell (Notifier/ system sensor/ firelite/ morley)/ Kidde/ UTC Fire & security (GST/ Edward)/ Siemens Fire Finder/ Bosch]3No
118Fault Isolator Module: Supply Installation Testing and Commissioning of UL/ ULC/ EN 54/ CE Listed Fault isolation module to electrically isolate different sections of detector loops (for every 20 detectors/ devices) as per detailed specifications.etc. as required. [Make: M/s. Honeywell (Notifier/ system sensor/ firelite/morley)/ Kidde/ UTC Fire & security (GST/ Edward)/ Siemens Fire Finder/ Bosch]1No
129Response Indicator: Response Indicator: Supply Installation Testing and Commissioning of Response indicator having twin LEDs for mounting on false ceiling/ wall at the entries of the cabin for indicating the operation of detectors in the above false ceiling/ below false flooring detectors etc. as required. [Make: M/s. Agni Instruments/ Agni Devices/ Aruna Agencies/ Carmel Sensor/ Ravel Elect./ Honeywell Essar/ Notifier/ Navin Systems]28Nos
1310Supplying and Fixing of 25mm dia Flexible Metalic conduit i/c end Termination complete etc as reqd.50Mtr
1411Supply, installation laying & commissioning of Copper cable in existing conduit / on tray / surface including cable laying hardware suitable for FAS with RED colour Outer sheath (2 C x 1.5 Sq. mm YWY FRLS Shielded Armored cable including end terminations in RED colour.)200Mtrs.
1512Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required
1612.01(a) 2 x 1.5 sq. mm50Mtr
1713Supplying and fixing of 4.5Kg capacity CO2 ( Carbon Dioxide) type fire extinguisher confirming to IS:15683 and cylinders duly charged complete with 1mtr long hose pipe & horn and other accessories commissioning etc. complete as required.2Nos.
1814Supplying and Fixing of 5 Kg capacity dry chemical powder type fire extingusher complete with hose pipe duly charged ready to use etc. complete as required.2Nos.

AI Tender Summary

OUR REF NO 21470433
AUTHORITY Government Departments
TENDER VALUE 3.59 Lakhs
LAST DATE 26-08-2019
Authority
Authority Name Bharat Sanchar Nigam Limited
Work Description Providing Of Electrical Installation Fans Mv Panel Earthing System Pkg Work At Air Force Station Nal 2 Distt Pdg Ei Fans Mv Panel Earthing System Precision Ac Pkg Work Fd System And Acd Cctv Camera Lighting Protection System In Proposed Refurbished Nfs Air Force Station At Nal2 Distt Bikaner Sh Pitc Of Addressable Fd And Fa System , Fire Alarm Control Panel ( Facp ) : Sitc Of Ul / Ulc / En 54 / Ce Listed Analogue Addressable Micro Processor Controlled , Standalone Main Fire Alarm Control Panel Having 1 Loop ( 1 Loop Card ) ( With Minimum 99 Detectors / 99 Devices Capacity Per Loop Card ) With Lcd Display , Capable Of Being Networked To The Central Monitoring System To Monitor And Integrate With Other Panels Such As Access Control System Along With Accessories Like Detectors , Lcps , Hooters , Control Modules , Monitor Modules Fault Isolation Modules , Response Indicators , Fire / Fault Indicators , Audio-Visual Signals , Central Processing Units , Complete With Lcd Display , Zone Indicating Leds , Having Multiple Access Levels , Event History File In Non-Volatile Memory ( Eeprom ) As Per The Detailed Specification , Complete With Psu , Battery Backup Along With Charger For 24 Hours In Non-Alarm Condition And 30 Minutes In Alarm Condition Etc . As Required For Each Panel . [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , Addressable Multisensor Detector: Supply , Installation , Testing And Commissioning Of Addressable Analogue Multisensor / Multicriteria Type , Ul / Ulc / En 54 / Ce Listed Photo Cum Thermal Detectors With Solid State Design , Indicating Led , Mounting Base , Mounting Bracket Etc . Base Box , Loop In & Loop Out Gland As Per Requirement And Detailed Specification As Per Following Positions . [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , A ) On Visible False Ceiling , B ) Above False / True Ceiling ( Base Box Is To Be Used ) , C ) Below False Flooring I / C S / F Of Ms Tripod ) , Addressable Heat Detector: Supply , Installation , Testing And Commissioning Of Addressable Analogue Type , Ul / Ulc / En 54 / Ce Listed Heat Detector Rate Of Rise Type With Solid State Design , Indicating Led , Mounting Base , Mounting Bracket Etc . Base Box , Loop In & Loop Out Gland As Per Requirement And Detailed Specification As Per Following Positions . [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , Addressable Control Modules: Supply Installation Testing And Commissioning Of Ul / Ulc / En 54 / Ce Listed , Addressable Control Module Complete With Junction Box Etc . For Control Options For Hooters & For Other Control Options Like Pa Evacuation , Access Doors Opening , Package Ac Trip Etc . In Case Of Emergency , As Required . [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , Addressable Monitoring Modules: Supply Installation Testing And Commissioning Of Ul / Ulc / En 54 / Ce Listed Addressable Monitoring Modules Complete With Junction Box Etc . To Monitor Status Of Other Systems Etc . As Required . [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , Manual Call Point: Supply Installation Testing And Commissioning Of Ul / Ulc / En 54 / Ce Listed Manual Call Points With No / Nc Contacts Slim Type With Pull Type / Break Glass With Reset Lock & Key Arrangement Suitable For Addressable Function [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , Electronic Hooter Cum Strobe: Supply Installation Testing And Commissioning Of Ul / Ulc / En 54 / Ce Listed Hooter Having Three Distinct Sounds With Addressable Relay Module And Strobe Light With Minimum 85 Db From 1 . 0 Mtr Distance Etc . As Required . [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , Fault Isolator Module: Supply Installation Testing And Commissioning Of Ul / Ulc / En 54 / Ce Listed Fault Isolation Module To Electrically Isolate Different Sections Of Detector Loops ( For Every 20 Detectors / Devices ) As Per Detailed Specifications . Etc . As Required . [ Make: M / S . Honeywell ( Notifier / System Sensor / Firelite / Morley ) / Kidde / Utc Fire & Security ( Gst / Edward ) / Siemens Fire Finder / Bosch ] , Response Indicator: Response Indicator: Supply Installation Testing And Commissioning Of Response Indicator Having Twin Leds For Mounting On False Ceiling / Wall At The Entries Of The Cabin For Indicating The Operation Of Detectors In The Above False Ceiling / Below False Flooring Detectors Etc . As Required . [ Make: M / S . Agni Instruments / Agni Devices / Aruna Agencies / Carmel Sensor / Ravel Elect . / Honeywell Essar / Notifier / Navin Systems ] , Supplying And Fixing Of 25Mm Dia Flexible Metalic Conduit I / C End Termination Complete Etc As Reqd . , Supply , Installation Laying & Commissioning Of Copper Cable In Existing Conduit / On Tray / Surface Including Cable Laying Hardware Suitable For Fas With Red Colour Outer Sheath ( 2 C X 1 . 5 Sq . Mm Ywy Frls Shielded Armored Cable Including End Terminations In Red Colour . ) , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor , Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required , ( A ) 2 X 1 . 5 Sq . Mm , Supplying And Fixing Of 4 . 5Kg Capacity Co2 ( Carbon Dioxide ) Type Fire Extinguisher Confirming To Is:15683 And Cylinders Duly Charged Complete With 1Mtr Long Hose Pipe & Horn And Other Accessories Commissioning Etc . Complete As Required . , Supplying And Fixing Of 5 Kg Capacity Dry Chemical Powder Type Fire Extingusher Complete With Hose Pipe Duly Charged Ready To Use Etc . Complete As Required .
Basic Detail
Tender No 18/EE(E)/BSNL/ED/SGNR/2019-20
Bidding Type Tender
Location
City Bikaner
State Rajasthan
Key Dates
Publish Date 20 Aug 2019
Submission Date 26 Aug 2019
Open Date 28 Aug 2019
Finance
Tender Value 3.59 Lakhs
Tender Fee 590
EMD 7183
Exemption Not Available
Document List
BOQ_519369.xls
Tendernotice_1.pdf
0568BEC3-EB38-4F8D-8A89-C8FFDE293DC7.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 26, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 28, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_519369.xls

pdf

Tendernotice_1.pdf

html

0568BEC3-EB38-4F8D-8A89-C8FFDE293DC7.html

TenderDetail