Supply Of Instruments & Equipments In Animal Husbandry Unit - Computed Radiography System , X-Ray Generator , Laser Healing Machine ., Director Animal Husbandry-Delhi
TDR : 21469737
Tender Notice
BOQ
Expired
Director Animal Husbandry
Delhi
Supply Of Instruments & Equipments In Animal Husbandry Unit - Computed Radiography System , X-Ray Generator , Laser Healing Machine .
Name of Work: Supply of Instruments & Equipments in Animal Husbandry Unit
Sl.No.
Item Description
Item Code / Make
Quantity
Units
1
1
Equipments and Instruments:
2
2
Computed Radiography System with DICOM Printer and Veterinary Software with Petitioners (Set of Five): Image reader CR Console, suitable for system Imaging plate 35×43 cm (14?×17?), 35×35 cm (14?×14?), 1 each Ip cassette type cc:35×43 cm (14?×17?), 35×35 cm (14?×14?), 1 each. Min. 49 sec. Up to 80 ips/hr. 10 Pixels/mm, 5 pixels/mm min. 30 sec. Approx 165 sec. 10 base t/100 base tx, 560 × 540 × 392 mm (22?×21?×15?), 39 kg (86 lbs.), Single phase 50-60 Hz, Ac 120-240 v ±10% 1.9 a (max), Operating conditions: Temperature: 15-30°c, Humidity: 15-80% rh (no dew condensation), Atmospheric pressure: 750-1060 hpa, should be supplied with 3 kw on line ups, PC/key board/mouse/Veterinary Specific Software, x ray positioner set of five Veterinary specific and two led x ray viewers. supplies for 500 x-rays sheets/film, Standard component: Thermal head transfers heat while in contact with thermal film, recording method: 35 x 43 (14x17), applicable film: 26 x 36, 25x30 (10x12), Film loading: 20 x 25 (8x10) daylight film. Film magazines: Loading up to 2 magazines, approx Processing capacity: 50 sheets/hour 35x43 (14x17), 75 sheets/hour 26x36, approx. 65 sheets/hour 25x30 (10x12), Approx. 90 sheets/hour 20x25 (8x10) 84.7µm (300dpi) 12 bits 1 gb Pixel size: Automatic dicom network input x1 channel only external dimensions recording gradation: (width): weight: power supply: 530 x 590 x 365mm (21x23x14”) image memory: With small magazine 180mm higher with optional sheet-feeder unit density adjustment: Input channels: dry imager. 32 Kg (71 lbs.)/43 kg (95 lbs.) with optional sheet-feeder unit input. to be supplied with interface arrangement if required at other location then x ray room .To have lan interconnectivity and the dicom printer to have provision to be connected to ultra sound /Doppler unit also. The unit should be provided with cables and other accessories to be connected to on line ups. Along with Consumables for C R System -1000 sheets. The successive bidder has to provide training for one week for use and handling of the instruments on the place as required.
VPH1803
1
1 No
3
3
X-RAY GENERATOR - High frequency (50 KHz) X-Ray generator for general radiography/1000MA.1:- GENERATOR RATING Power Output 80 KW Radiography KV ranges 40 to 150KV. Radiography Ma Output Up to 1000Ma, Radiography mAs range 1mAs to 200mAs. 2:- CONTROL PANEL compact, soft feather Touch Control Panel Having following Functions& indications: ON/OFF Switch Digital Display OF KV &mAs. K V &mAs increase and decrease switches. Ready and X-Ray on switch with indicators. Bucky Selection Switch. Self-diagnostic Programmed with indicators for Earth Fault error, KV error, filament error & Tube’s Thermal Overload. Anatomical A Preprogramed Parameters of animal Anatomy should be available to select exposure Parameters based on body Part, examination view and size of the small & big animals. 4:- H.V.TANK a compact H.V. tank filled with high dielectric transformer oil. The H.V. Tank contains H.V. Transformer, filament transformers, H.V. rectifiers and H.V. cable receptacles. 5:- H.V. CABLE Pair of H.V. Cable compatible with the X-Ray Tube. 6:- TUBE STAND Counter Balanced 3D-Ceilling Suspended tube stand 3:- X-RAY TUBE for complete Anatomical Programming up to 216 Programmes. A dual action hand Switch with Retractable cord .01 No. Dual focus Stand have Longitudinal, Transverse and vertical movement. TUBE Head Rotation along its axis. Movements of stand should be: Longitudinal movement: 3350mm. Transverse movement: 2430 mm. Motorized Vertical up/down movement: 1600 mm Tube head Rotation along Horizontal axis ±90°. Tube head Rotation along vertical axis ±180°. 7:- POWER SUPPLY 3 Phase, 400Volts AC 50Hz with line resistance: <0.4 Ohms. Line Regulation ± 10% with proper independent earthling. Rotating Anode X –Ray tube of make /model Vertex (Varian)/A192, thermally Protected Have Following focal spots: Small Focus: 0.6 Focus: 1.2 Anode heat storage capacity of the tube should be 300 KHU. COLLIMATOR Provided. Large 8:- SERVO VOLTAGE STABILIZER a servo voltage stabilizer of suitable rating of 200 kw or of suitable rating. Compatible tables for large animals Supplied with hoof positioner/distance arm and protector set suitable for CR system cassettes12x15 inch. The successive bidder has to provide training for one week for use and handling of the instruments on the place as required.
VPH1805
1
1 No
4
4
Laser Healing Machine; -Class 3 B laser therapy to treat injured tendons, muscles and ligaments. Single and cluster head with OLED colour screen, RF inter lock should available in all waive length, have provided with recharge batteries should penetrate up to 4-5 cm, Two year warranty.