Providing Wiring / Rewiring And Miscellaneous Electrical Equipments In Type-I Gbph Staff Qtrs , New Delhi-1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Piano Type Switch, Phenolic Laminated Sheet, Suitable Size Ms Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A Group A 2 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required. A Group A 3 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 4 Wiring For Light / Power Plug With 4X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 2 Nos. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 5 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. A 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire B 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 6 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. A 6 X 1.5 Sq. Mm 7 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. A 20 Mm B 25 Mm 8 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required. A 5 / 6 A Switch B Bell Push 9 Supplying And Fixing Metal Box Of 150 Mm X 75 Mm X 60 Mm Deep ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Providing And Fixing 3 Pin 5 / 6 A Socket Outlet And 5 / 6 A Piano Type Switch, Connections, Painting Etc. As Required. 10 Supplying And Fixing Metal Box Of 180 Mm X 100 Mm X 60 Mm Deep ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Providing And Fixing 6 Pin 5 / 6 A & 15 / 16 A Socket Outlet And 15 / 16 A Piano Type Switch, Connections, Painting Etc. As Required. 11 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 12 Supplying And Fixing Brass Batten / Angle Holder Including Connections Etc. As Required. 13 Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 V, Complete As Required. 14 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) A 8 Way, Double Door 15 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. A Single Pole B Single Pole And Neutral 16 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. A 100 A 17 Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 18 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 19 Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A, “C” Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. 20 Supplying & Fixing Of 3 Mm. Thick Phenolic Laminated Hylam Sheet Of Assorted Sizes On Existing Switch Box With Cadmium Plated Screws Etc. Complete As Reqd. 21 Supplying, Installation, Testing And Commissioning Of 4Ft. 20 Watt Led Fitting Endura Linear Neo Surface And Wall Mounted Led Batten, Extruded Aluminium Housing Provided For Efficient Heat Dissipation With Polycarbonate Diffuser & Integrated Electronic Driver Etc .I / C Connection Etc As Reqd. The Luminaries Shall Be Submitted With Lm-80 Report With A Life Of 50000 Hours @ L-70 And Led Photo Biological Safety Report Conforming To Iec 62471 & Led Source Manufacturer And Lm-79 Report From Nabl Accredited Lab. The Led Chip Should Be Of Cree, Nichia, Lumiled, Osram, Seoul .I / C By Back The Existing Light 22 Supplying, Installation, Testing And Commissioning Of 1200 Mm Sweep Ceiling Fan, 5 Star Rating I / C Wiring The Down Rod Of Standard Length ( Up To 30Cm ) With 1.5Sqmm Fr Pvc Insulated Copper Conductor Single Core Cable As Reqd. .I / C Buy Back Of Old Existing Celing Fan 23 S.I.T.C. Of Heavy Duty Exhaust Fan Of 300Mm Sweep & 1400 Rpm In The Existing Opening I / C Making The Hole To Suit The Size Of The Above Fan, Making Good The Damage, Connection, Tasting, Commissioning Etc As Reqd.I / C Buy Back Of Old Existing Exhaust Fan 23 Supplying, Installation, Testing & Commissioning Of Led Streetlight Of System Wattage 45 W Ip66 Multiple Led With Lens Optics And Pressure Die-Cast Aluminium Housing For Effective Thermal Management. Total System Lumen Of 45W Led Should Be 4200 Or Above In Cool Day Light ( 5000K To 6000K ) , Lumen Efficacy>90 Lm / W, Power Factor>0.95, Cri>70. Complete With Mounting Brackets & Accessories As Required With Connections. The Luminaries Shall Be Submitted With Lm-80 Report With A Life Of 50000 Hours @ L-70 And Led Photo Biological Safety Report Conforming To Iec 62471 & Led Source Manufacturer And Lm-79 Report From Nabl Accredited Lab. The Led Chip Should Be Of Cree, Nichia, Lumiled, Osram, Seoul.