Repair , Maintenance Of Summer Appliances Water Coolers , Desert Coolers , Ac . Refrigerators , Deep Freezers , Geysers And Repair , Overhauling Of Ceiling Fans , Exhaust Fans , Air Circulators Etc At Kanasar Military Station, Kanasar-Rajasthan

Military Engineer Services-MES has published Repair , Maintenance Of Summer Appliances Water Coolers , Desert Coolers , Ac . Refrigerators , Deep Freezers , Geysers And Repair , Overhauling Of Ceiling Fans , Exhaust Fans , Air Circulators Etc At Kanasar Military Station. Submission Date for this Tender is 07-09-2019. Air Circulators Tenders in Kanasar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

21464859
Repair , Maintenance Of Summer Appliances Water Coolers , Desert Coolers , Ac . Refrigerators , Deep Freezers , Geysers And Repair , Overhauling Of Ceiling Fans , Exhaust Fans , Air Circulators Etc At Kanasar Military Station
Open Tender
Indian
Rajasthan
Kanasar
07-09-2019

Tender Details

Repair , Maintenance Of Summer Appliances Water Coolers , Desert Coolers , Ac . Refrigerators , Deep Freezers , Geysers And Repair , Overhauling Of Ceiling Fans , Exhaust Fans , Air Circulators Etc At Kanasar Military Station

Key Value

Document Fees
INR 500 /-
EMD
INR 10000.0 /-
Tender Value
INR 5 Lakhs /-

BOQ Items

Name of Work : Repair/ maintenance of summer appliances water coolers, desert coolers, ac. refrigerators, deep freezers, Geysers and repair/ overhauling of ceiling fans, exhaust fans, air circulators etc at Kanasar Military Station
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down and Dismantling of ceiling fan 1200mm/1400mm sweep of any make new/old model by opening the cover, separating down rod, rotor and stator assembly, locating the fault and making the fan fully in serviceable condition including replacing the defective worn out screws of the cover, split pin, oiling, and greasing etc. including repainting with synthetic enamel paint by spraying including filling cavities with filler, re-writing of MES No as of original size with stencil, including cleaning of the rating plate with the thinner complete all as specified and directed by Engineer-in-Charge. Note :- Rewindng and parts such as bushings, bearings, condensers, ‘D’ clamps with nuts, quarter pin and rubber seal, down rod, PVC canopies, flexible wire & shaft etc shall be measured and paid for separately under the respective items here-in- after 150 Each Job
2 2 M & L for Re-winding motor of ceiling fan any make/model model size 1200mm sweep with super enameled copper winding wire of existing specification, gauge & weight conforming to IS including insulating material & varnishing the motor windings with good quality varnish complete all as specified and directed by Engineer-in-Charge. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL 120 Each Job
3 3 Supply for replacement of ball bearing of suitable size. Make: ''NBC/SKF conforming to IS 80 Each
4 4 Supply for replacement of brass bush suitable for ceiling fan any make/model all as per original size/shape/type conforming to IS 80 Each
5 5 Supply for replacement of shaft as per existing size and shape 45 Each
6 6 Supply for replacement of blades for 1200 mm sweep fan as per sample kept in AGE's office. 40 Set of three
7 7 M & L for Re-winding motor of ceiling fan any make/model model size 1400mm sweep with super enameled copper winding wire of existing specification, gauge & weight conforming to IS including insulating material & varnishing the motor windings with good quality varnish complete all as specified and directed by Engineer-in-Charge. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL 30 Each Job
8 8 Supply, fixing in replacement of ball bearing of suitable size. Make: ''NBC/SKF conforming to IS 30 Each
9 9 Supply, fixing in replacement of brass bush suitable for ceiling fan any make/model all as per original size/shape/type conforming to IS 30 Each
10 10 Supply, fixing in replacement of shaft as per existing size and shape 15 Each
11 11 Dismantling of Exhaust fan 225 mm /300 mm /450 mm sweep of any make, opening the cover, separating the rotor and stator assembly, locating the fault and making the exhaust fan fully in serviceable condition including replacing the defective worn out screws, flexible wire of size 23/0.0076, oiling, greasing, reassembling the fan and testing complete to the satisfaction of the Engineer in Charge. Note : Rewinding and parts such as capacitors, blades and shaft etc. shall be measured and paid for separately under the respective items here-in- after 50 Each Job
12 12 M & L for Re-winding of exhaust fan 300 mm sweep with super enameled copper winding wires of size 35/36 SWG or as per existing size of wire confirming to IS including varnishing the motor windings with good quality varnish complete all as specified and directed by Engineer-in-Charge. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL 20 Each Job
13 13 All as per serial item No. 12 here-in-before but of 450 mm sweep 5 Each Job
14 14 All as per serial item No. 12 here-in-before but of 225 mm sweep 15 Each Job
15 15 Supply, fixing in replacement of blades for exhaust fan 300 mm sweep as per sample kept in AGE's office. 5 Each set
16 16 Supply, fixing in replacement of blades for exhaust fan 450 mm sweep as per sample kept in AGE's office. 7 Set of three
17 17 Supply, fixing in replacement of shaft MS as per existing size and shape 5 Each
18 18 Supply, fixing in replacement of condenser 04 MFD including necessary connection. Make : 'Tibcon/Orient/Crompton Greaves/ Kawality conforming to IS 30 Each
19 19 Dismantling of cabin/wall mounting fans of any sweep/ size/ make, opening the cover, separating the rotor and stator assembly, locating the fault and making the fan fully in serviceable condition including replacing the defective worn out screws, flexible wire of size 23/0.0076, oiling, greasing, reassembling the fan and testing complete to the satisfaction of the Engineer in Charge. Note :- Rewinding and parts such bushings, etc will be measured and paid for separately under the respective items here-in -after 3 Each Job
20 20 M & L for Re-winding of cabin fan with super enameled copper winding wires of existing specification, gauge & weight including insulating material & varnishing the motor windings with good quality varnish complete all as specified and directed by Engineer-in-Charge. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL 3 Each Job
21 21 Supply for replacement of brass bush suitable for cabin/wall mounting fan any make/model all as per original size/shape/type 6 Each
22 22 Supply, fixing in replacement down rod one foot long suitable for 1200/1400mm sweep of ceiling fan all as required at site complete all as specified and directed by Engineer-in-Charge 80 Each
23 23 Supply, fixing in replacement 'D' clamp with nuts, check nuts, quarter pin and rubber reel suitable for 1200/1400mm sweep of ceiling fan all as required at site complete all as specified and directed by Engineer-in-Charge 80 Each
24 24 Supply, fixing in replacement PVC Canopies (set of two) with steel screws as ordered or sample given by the Engineer-in-Charge 50 Each
25 25 Supply, fixing in replacement condenser in replaceme 2.5 MFD conforming to IS including necessary connection complete all as specified and directed by Engineer-in-Charge. Make: 'Tibcon/Orient/ Crompton Greaves/ Kwality' 200 Each
26 26 Supply, fixing in replacement of flexible wire of size 23/0.0076 stranded copper conductor complete all as specified and directed by Engineer-in-Charge. Make: 'PARAGON /FINOLEX/ INCAB/ HAVELLS/ PLAZA/ ANCHOR' 10 RM
27 27 REPAIR TO WATER COOLERS
28 28 Taking down unserviceable compressor including bushes, grommets sleeves, washers , mounting rubbers, nuts, bolts, terminal cover, brazing and clips from existing water coolers of any make and Supply and fixing new hermetically sealed unit (compressor) of the makes and model as specified including providing new bushes , grommets, sleeves, washers, mounting rubbers , nuts and bolts, terminal covers, brazing and clips in the existing water coolers of capacity 40/80 Litre of make Blue Star/Voltas with necessary accessories required for smooth functioning all as specified 4 Each Job
29 29 All as per item No. 28 here-in-before but water coolers of capacity 60/120 Litre of make Blue Star/Voltas 1 Each Job
30 30 Taking down carefully existing internal wiring of existing water coolers and in lieu providing new internal wiring with PVC insulated copper conductor wire of size 40/0.0076 sqmm including replacement of main lead 03 meter long ,terminal clips, thimbles, 03 pin plug top 15 amps & soldering extra complete all as specified.\n Make of wire- PARAGON/FINOLEX/ INCAB/ HAVELLS/PLAZA/ANCHOR'\n 7 Each Job
31 31 Taking down carefully the following accessories/ parts from the existing water coolers and in lieu providing new accessories / parts in the same water coolers as per details given below
32 32 Filter copper. 6 Each
33 33 Capillary tube of existing size of copper as per sample as approved by Engineer-in-Charge 6 Each
34 34 PVC water outlet pipe 15 mm dia including clamps 6 Each
35 35 Drain pipe of same quality, length and diameter as per existing 6 Each
36 36 Condenser size 12” x 12” or 12” x 15”. 6 Each
37 37 Cleaning of complete existing gas system with CTC solution, testing of leakage, charging of refrigerant with R-134 (a) upto desired pressure after rectification of leakage in existing water coolers complete all as specified and as directed by Engineer-in-Charge 6 Each Job
38 38 Taking down defective Fan motor of capacity 1/16 HP, 230 volts, single phase from water coolers, dismantling the old burnt winding from the motor and rewinding with super enameled copper wire as per existing size including replacement of shaft, bushes mounting rubbers , nuts bolts and re-fixing after reassembling and testing in existing water coolersall as per directed by the Engineer-in-Charge. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL. Note:- The unit rates quoted shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers insulating materials and clamps 1 Each Job
39 39 All as per item No. 38 here-in-before but Fan motors of capacity 1/35 HP, 230 volts, single phase 3 Each Job
40 40 All as per item No. 38 here-in-before but Fan motors of capacity 1/10 HP, 230 volts, single phase 1 Each Job
41 41 Supply & fixing in replacement blade of aluminium as per sample kept in AGE office for blower motor of water cooler (any make, model & capacity) complete all as specified & directed by the Engineer-in-Charge 7 Each Set
42 42 Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/35 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified .\nMake of fan motor:-Shriram / Polor/ Cool Home/ Frac Master\n 3 Each
43 43 Supply and fixing in repair push cock (Stainless steel) of existing make and specifications for water cooler 10 Each
44 44 Supply and fixing in repair thermostat for water cooler Make :- Indfoss/ Whirlpool/ Electrolux 8 Each
45 45 Supply and fixing in repair relay with OLP suitable for water cooler. Make : Annapurna/ Hitachi/ Whirpool/ Godrej 8 Each
46 46 Supply and fixing in repair running capacitor 36 MFD. Make : Tibcon/Sharda/Epcos/ Testla/ Siemens 5 Each
47 47 Supply and fixing in repair capacitor 10 MFD Make : Tibcon/Sharda/Epcos/ Testla/ Siemens 5 Each
48 48 Supply and fixing in repair capacitor 15 MFD (Running) Make : Tibcon/Sharda/Epcos/ Testla/ Siemens 3 Each
49 49 Supply and fixing in repair capacitor 40/60 MFD (starting) Make : Tibcon/Sharda/Epcos/ Testla/ Siemens 4 Each
50 50 Supply and fixing in replacement Cable 3 core, copper conductor size 40/0.0076 for water cooler all as specified. Make of cable:- Plaza/ Finolex / Kalinga/ Havells 50 RM
51 51 REPAIR TO AIR CONDITIONERS
52 52 Taking out the unserviceable compressor from the air conditioner window/split type 2 ton capacity of any make & type and supply and fixing in replacement same capacity reconditioned compressor obtained from the factory out let make Kirloskar/ Tecumseh/ Carrier (with two year guarantee), including soldering of copper pipe, cleaning the refrigerant system, condenser tubing by vacuumisation, cleaning the system by CTC solution, pressure testing of the system, charging of refrigerant gas with R- 134 (a) gas and compressor oil in the system to its rated capacity including checking of leakage, replacement of foundation rubber pads , nut and bolts, including testing on full load complete all as specified and as directed by Engineer-in-Charge 1 Each Job
53 53 All as per serial item No 52 here in before but for window type A/C 1.5 Ton capacity of any make 2 Each Job
54 54 Material and labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for de-moistureing the system and gas charging by R-134 (a) upto the required pressure for 1.5 ton window/ split type air conditioner complete all as specified and directed by Engineer-in-charge 2 Each Job
55 55 All as per serial item No 54 here in before but for window / Split type A/C 2 Ton capacity of any make 1 Each Job
56 56 Taking down of old unserviceable fan motor of any capacity from the window type/ split type Air Conditioners 1.5/2 TR capacity and dismantling old and unserviceable burnt winding wire and rewinding with super enameled copper wire of existing gauge and size including heat varnishes replacement of shaft, bearing and bush complete as found unserviceable after opening complete all as specified and as directed. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL (The unit rates quoted shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers insulating materials and clamps). 2 Each Job
57 57 Taking down carefully window / split type AC 1.5/2.0 ton capacity, from its location and removing dirt and dust from interior and exterior of the Air conditioner and washing the condensor and evaporator with vami clean solution and other areas by soap solution, spraying pressurised water on condensor and evaporator with proper protection of electrical fixtures and connections, drying by blowing air, including replacement of air filter as per existing make and model, placing the window type air conditioner in its place all as specified and directed by Engineer-in-charge 5 Each Job
58 58 Supply and fixing in repair capacitor 45 MFD (Running) Make : Tibcon/Sharda/Epcos/ Testla/ Siemens 3 Each
59 59 Supply and fixing in repair capacitor 50 MFD Make : Tibcon/Sharda/Epcos/ Testla/ Siemens 2 Each
60 60 REPAIR TO REFRIGERATORS
61 61 Taking down unserviceable compressor including bushes, grommets sleeves, washers, mounting rubbers, nuts, bolts, terminal cover, brazing and clips from existing refrigerators of Make : Voltas / Whirlpool/ Kelvinator/ Zenith/ MEC capacity 165/180/310 ltrs compete all as directed 2 Each Job
62 62 Supply and fixing new compressor obtained from manufacturer or authorised dealer of Voltas / Whirlpool/ Kelvinator/ Zenith/ MEC alongwith test certificate and with Two year guarantee card, commissioning and testing on full load of new compressor including supply and charging of refrigerant gas in the system its rated capacity and including replacement of copper filter single capillary bushes, grommets, sleeves , washers , mounting rubbers nuts and bolts, terminal covers, brazing and clips of existing make and capacity in the existing refrigerator for 165/180 ltrs capacity complete all as directed by Engineer - in – Charge 1 Each Job
63 63 All as per item No. 62 here-in-before but for 310 ltrs capacity of any make 1 Each Job
64 64 Cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing refrigerators of 165/180/310 ltrs capacity of make and model as per existing complete all as specified and as directed 3 Each Job
65 65 Taking down carefully the following accessories/ parts from existing refrigerator of any make for 165/180/310 liters capacity and in lieu providing new accessories / parts as per existing in the same refrigerators as under :-
66 66 Evaporator for 310 liters refrigerators of any make 2 Each
67 67 Filter suitable for 310 liters of any make. 2 Each
68 68 Capillary tubes of existing sizes of copper as per sample approved by Engineer-in-Charge 2 Each
69 69 Supply and fixing in replacement thermostat for refrigerator 310 Ltr capacity Make Indfoss 2 Each
70 70 Supply and fixing in replacement relay for refrigerator 310 Ltr capacity Make : Godrej/ Hi- Tech 2 Each
71 71 Supply for replacement Vegetable tray for refrigerator of 165 Ltrs capacity as per sample approved by Engineer-in-Charge 2 Each
72 72 Supply for replacement Vegetable tray for refrigerator of 240 Ltrs capacity as per sample approved by Engineer-in-Charge 2 Each
73 73 Supply for replacement Vegetable tray for refrigerator of 310 Ltrs capacity as per sample approved by Engineer-in-Charge 2 Each
74 74 Taking down carefully the following parts from the existing AC and in lieu providing new accessories/parts as per existing as under
75 75 Contactor for split AC 5 Each
76 76 PCB of AC split/ window (1.5/2.00/3.00 ton) 4 Each
77 77 Starting relay for AC 5 Each
78 78 REPAIR TO DESERT COOLERS
79 79 Removing of old paint complete with emery paper and cleaning with scrapper and preparation of internal surfaces & bottom of the desert coolers of any size and apply one coat of black bituminous paint complete all as specified 40 Each Job
80 80 Removing of old paint complete with emery paper and cleaning with scrapper and preparation of external surfaces including steel grills, side panel etc of the desert coolers of any size applying one coat of synthetic enamel paint complete all as specified 40 Each Job
81 81 Taking down carefully old unserviceable water pumps and in lieu providing new submersible type water pump heavy duty of capacity 1/70 HP , 230 volts 50 HZ single phase complete all as specified. Make :- Khaitan/Poler/Cool home 65 Each Job
82 82 Taking down carefully fan motor from existing desert coolers and in lieu providing new fan motor kit 1/6 to 1/8 HP 230 volts 50 HZ including replacement of mounting legs complete all as specified and directed. \nMake : Khaitan/ Crompton Greaves \n 30 Each Job
83 83 Taking down carefully fan motor 1/6 to 1/8 HP 230 volts, 50 HZ, from existing desert coolers and refixing the same fan motor after rewinding with super enameled copper wire of existing size complete including replacement of mounting legs complete all as specified and directed by Engineer-in-Charge. Make of copper wire : MILAN/ ATLAS/ CHETAK/ DEVIDAYA 15 Each Job
84 84 Taking down the following parts from the existing desert coolers in lieu providing new parts as per existing as under :-
85 85 Capacitor for desert cooler 4 MFD 230 volts Make: Asian/ Tibcon/ 50 Each
86 86 PVC front grill including nuts bolts and washers suitable for 18/20” sweep desert coolers. Make Alka/Konark 40 Each
87 87 Supply and fixing in replacement wood wool pads (set of three) weight not less than 500 gms superior quality complete all as directed by Engineer-in –Charge 80 Each Set
88 88 Supply and fixing in replacement Supporting Jali for desert coolers \n( set of three )\n 80 Each Set
89 89 Supply and fixing in replacement Plug top, 3 pin, 5 Amps, 230 Volts, ISI marked, complete all as specified and as directed by Engineer-in-Charge. Make : Anchor/MDS/Leader/ LEGRAND/HAVELLS 30 Each
90 90 Supply and fixing in replacement Fan blade size of aluminium for desert cooler as as per sample approved by Engineer-in-Charge 30 Each Set
91 91 Supply and fixing in replacement of PVC flexible pipe 15 mm dia of superior quality heavy duty suitable for desert cooler of any capacity complete all as directed by Engineer-in –Charge 125 RM
92 92 Supply and fixing in replacement ball brass valves, high pressure, with polythene float and fly-nut (PTMT) complete, screwed for iron pipe or brass ferrule , suitable for 15mm bore pipe complete all specified and as directed.Make Prayag/ Polytuf 8 Each
93 93 Repair to Geysers
94 94 Taking down and opening of the geysers 25/50 ltrs capacity storage type any make complete for inspection, descaling by chemical treatment of internal parts such as tank, base plate assembly (siphon system), heating element, etc re-assembling and refixing the same to its original position after testing on pressure complete all as directed by the Engineer-in-charge. \nNote:- Items such as glass wool, tank, siphon system, outer cover etc if found unserviceable under above item will be measured and paid for separately under its relevant item as supply only 50 Each Job
95 95 S&F in replacement Thermostat switch ISI marked to Geysers 25/50 ltrs all as specified & directed by the Engineer-in-Charge. Make : Alert/Theta /Bajaj. 35 Each
96 96 S&F in replacement siphon assembly suitable for Geysers 25 ltrs all as specified & directed by the Engineer-in-Charge. 5 Each
97 97 S&F in replacement Low density polythene pipe (LDPE) connection arrangement with pipe of pressure rating 2.5 kgf/cm2 , 15 mm bore, 30 cm to 45 cm long with brass unions (Chromium plated) one on each side all as specified & directed by the Engineer-in-Charge. 50 Each
98 98 S&F in replacement Plug and socket in sheet metal enclosure with 2 pin and earth plug and socket complete with and including MCB, SP, 20 Amps , 240 volts heavy duty all as specified.Make:-Legrand Cat Part 607851/ equivalent cat part No. in Hagger /L&T/ Standrad 10 Each
99 99 S & F in replacement MCB suitable for 6 to 32 Amps, 240 Volt AC supply , SPN, with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make:- Anchor/MDS/Leader/ LEGRAND/HAVELLS 25 Each
100 100 S & F in replacement heating element ISI Marked of rating 1.5 KW capacity including washers for 25 ltrs capacity Geysers all as specified.\nMake :- THETA/ ALERT 15 Each
101 101 S & F in replacement heating element ISI Marked of rating 2 KW capacity including washers for 50 ltrs capacity Geysers all as specified.\nMake :- THETA/ ALERT 25 Each
102 102 Supply and fixing in replacement Plug top, 3 pin, 15 Amps, 230 Volts, ISI marked, complete all as specified and as directed by Engineer-in-Charge. Make:- Anchor/MDS/Leader/ LEGRAND/HAVELLS 20 Each
103 103 Supply and fixing in repair release valve suitable for 15 mm bore of pipe for 25/ 50 ltrs capacity Geysers, ISI marked all as specified.\nMake :- Jindal/Prakash/ UNIK/KS. 15 Each
104 104 Supplied and fixed in repairs bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule suitable for 15mm bore GI pipe complete all as specified and as directed by Engineer-in-Charge.\nMake :- JAQUAR/PRAYAG/SIEKO/PARKO/ HINDWARE/MARC\n 14 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy