Military Engineer Services-MES has published Repair , Maintenance Of Summer Appliances Water Coolers , Desert Coolers , Ac . Refrigerators , Deep Freezers , Geysers And Repair , Overhauling Of Ceiling Fans , Exhaust Fans , Air Circulators Etc At Kanasar Military Station. Submission Date for this Tender is 07-09-2019. Air Circulators Tenders in Kanasar Rajasthan. Bidders can get complete Tender details and download the document.
Name of Work : Repair/ maintenance of summer appliances water coolers, desert coolers, ac. refrigerators, deep freezers, Geysers and repair/ overhauling of ceiling fans, exhaust fans, air circulators etc at Kanasar Military Station | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down and Dismantling of ceiling fan 1200mm/1400mm sweep of any make new/old model by opening the cover, separating down rod, rotor and stator assembly, locating the fault and making the fan fully in serviceable condition including replacing the defective worn out screws of the cover, split pin, oiling, and greasing etc. including repainting with synthetic enamel paint by spraying including filling cavities with filler, re-writing of MES No as of original size with stencil, including cleaning of the rating plate with the thinner complete all as specified and directed by Engineer-in-Charge. Note :- Rewindng and parts such as bushings, bearings, condensers, ‘D’ clamps with nuts, quarter pin and rubber seal, down rod, PVC canopies, flexible wire & shaft etc shall be measured and paid for separately under the respective items here-in- after | 150 | Each Job | |
2 | 2 | M & L for Re-winding motor of ceiling fan any make/model model size 1200mm sweep with super enameled copper winding wire of existing specification, gauge & weight conforming to IS including insulating material & varnishing the motor windings with good quality varnish complete all as specified and directed by Engineer-in-Charge. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL | 120 | Each Job | |
3 | 3 | Supply for replacement of ball bearing of suitable size. Make: ''NBC/SKF conforming to IS | 80 | Each | |
4 | 4 | Supply for replacement of brass bush suitable for ceiling fan any make/model all as per original size/shape/type conforming to IS | 80 | Each | |
5 | 5 | Supply for replacement of shaft as per existing size and shape | 45 | Each | |
6 | 6 | Supply for replacement of blades for 1200 mm sweep fan as per sample kept in AGE's office. | 40 | Set of three | |
7 | 7 | M & L for Re-winding motor of ceiling fan any make/model model size 1400mm sweep with super enameled copper winding wire of existing specification, gauge & weight conforming to IS including insulating material & varnishing the motor windings with good quality varnish complete all as specified and directed by Engineer-in-Charge. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL | 30 | Each Job | |
8 | 8 | Supply, fixing in replacement of ball bearing of suitable size. Make: ''NBC/SKF conforming to IS | 30 | Each | |
9 | 9 | Supply, fixing in replacement of brass bush suitable for ceiling fan any make/model all as per original size/shape/type conforming to IS | 30 | Each | |
10 | 10 | Supply, fixing in replacement of shaft as per existing size and shape | 15 | Each | |
11 | 11 | Dismantling of Exhaust fan 225 mm /300 mm /450 mm sweep of any make, opening the cover, separating the rotor and stator assembly, locating the fault and making the exhaust fan fully in serviceable condition including replacing the defective worn out screws, flexible wire of size 23/0.0076, oiling, greasing, reassembling the fan and testing complete to the satisfaction of the Engineer in Charge. Note : Rewinding and parts such as capacitors, blades and shaft etc. shall be measured and paid for separately under the respective items here-in- after | 50 | Each Job | |
12 | 12 | M & L for Re-winding of exhaust fan 300 mm sweep with super enameled copper winding wires of size 35/36 SWG or as per existing size of wire confirming to IS including varnishing the motor windings with good quality varnish complete all as specified and directed by Engineer-in-Charge. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL | 20 | Each Job | |
13 | 13 | All as per serial item No. 12 here-in-before but of 450 mm sweep | 5 | Each Job | |
14 | 14 | All as per serial item No. 12 here-in-before but of 225 mm sweep | 15 | Each Job | |
15 | 15 | Supply, fixing in replacement of blades for exhaust fan 300 mm sweep as per sample kept in AGE's office. | 5 | Each set | |
16 | 16 | Supply, fixing in replacement of blades for exhaust fan 450 mm sweep as per sample kept in AGE's office. | 7 | Set of three | |
17 | 17 | Supply, fixing in replacement of shaft MS as per existing size and shape | 5 | Each | |
18 | 18 | Supply, fixing in replacement of condenser 04 MFD including necessary connection. Make : 'Tibcon/Orient/Crompton Greaves/ Kawality conforming to IS | 30 | Each | |
19 | 19 | Dismantling of cabin/wall mounting fans of any sweep/ size/ make, opening the cover, separating the rotor and stator assembly, locating the fault and making the fan fully in serviceable condition including replacing the defective worn out screws, flexible wire of size 23/0.0076, oiling, greasing, reassembling the fan and testing complete to the satisfaction of the Engineer in Charge. Note :- Rewinding and parts such bushings, etc will be measured and paid for separately under the respective items here-in -after | 3 | Each Job | |
20 | 20 | M & L for Re-winding of cabin fan with super enameled copper winding wires of existing specification, gauge & weight including insulating material & varnishing the motor windings with good quality varnish complete all as specified and directed by Engineer-in-Charge. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL | 3 | Each Job | |
21 | 21 | Supply for replacement of brass bush suitable for cabin/wall mounting fan any make/model all as per original size/shape/type | 6 | Each | |
22 | 22 | Supply, fixing in replacement down rod one foot long suitable for 1200/1400mm sweep of ceiling fan all as required at site complete all as specified and directed by Engineer-in-Charge | 80 | Each | |
23 | 23 | Supply, fixing in replacement 'D' clamp with nuts, check nuts, quarter pin and rubber reel suitable for 1200/1400mm sweep of ceiling fan all as required at site complete all as specified and directed by Engineer-in-Charge | 80 | Each | |
24 | 24 | Supply, fixing in replacement PVC Canopies (set of two) with steel screws as ordered or sample given by the Engineer-in-Charge | 50 | Each | |
25 | 25 | Supply, fixing in replacement condenser in replaceme 2.5 MFD conforming to IS including necessary connection complete all as specified and directed by Engineer-in-Charge. Make: 'Tibcon/Orient/ Crompton Greaves/ Kwality' | 200 | Each | |
26 | 26 | Supply, fixing in replacement of flexible wire of size 23/0.0076 stranded copper conductor complete all as specified and directed by Engineer-in-Charge. Make: 'PARAGON /FINOLEX/ INCAB/ HAVELLS/ PLAZA/ ANCHOR' | 10 | RM | |
27 | 27 | REPAIR TO WATER COOLERS | |||
28 | 28 | Taking down unserviceable compressor including bushes, grommets sleeves, washers , mounting rubbers, nuts, bolts, terminal cover, brazing and clips from existing water coolers of any make and Supply and fixing new hermetically sealed unit (compressor) of the makes and model as specified including providing new bushes , grommets, sleeves, washers, mounting rubbers , nuts and bolts, terminal covers, brazing and clips in the existing water coolers of capacity 40/80 Litre of make Blue Star/Voltas with necessary accessories required for smooth functioning all as specified | 4 | Each Job | |
29 | 29 | All as per item No. 28 here-in-before but water coolers of capacity 60/120 Litre of make Blue Star/Voltas | 1 | Each Job | |
30 | 30 | Taking down carefully existing internal wiring of existing water coolers and in lieu providing new internal wiring with PVC insulated copper conductor wire of size 40/0.0076 sqmm including replacement of main lead 03 meter long ,terminal clips, thimbles, 03 pin plug top 15 amps & soldering extra complete all as specified.\n Make of wire- PARAGON/FINOLEX/ INCAB/ HAVELLS/PLAZA/ANCHOR'\n | 7 | Each Job | |
31 | 31 | Taking down carefully the following accessories/ parts from the existing water coolers and in lieu providing new accessories / parts in the same water coolers as per details given below | |||
32 | 32 | Filter copper. | 6 | Each | |
33 | 33 | Capillary tube of existing size of copper as per sample as approved by Engineer-in-Charge | 6 | Each | |
34 | 34 | PVC water outlet pipe 15 mm dia including clamps | 6 | Each | |
35 | 35 | Drain pipe of same quality, length and diameter as per existing | 6 | Each | |
36 | 36 | Condenser size 12” x 12” or 12” x 15”. | 6 | Each | |
37 | 37 | Cleaning of complete existing gas system with CTC solution, testing of leakage, charging of refrigerant with R-134 (a) upto desired pressure after rectification of leakage in existing water coolers complete all as specified and as directed by Engineer-in-Charge | 6 | Each Job | |
38 | 38 | Taking down defective Fan motor of capacity 1/16 HP, 230 volts, single phase from water coolers, dismantling the old burnt winding from the motor and rewinding with super enameled copper wire as per existing size including replacement of shaft, bushes mounting rubbers , nuts bolts and re-fixing after reassembling and testing in existing water coolersall as per directed by the Engineer-in-Charge. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL. Note:- The unit rates quoted shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers insulating materials and clamps | 1 | Each Job | |
39 | 39 | All as per item No. 38 here-in-before but Fan motors of capacity 1/35 HP, 230 volts, single phase | 3 | Each Job | |
40 | 40 | All as per item No. 38 here-in-before but Fan motors of capacity 1/10 HP, 230 volts, single phase | 1 | Each Job | |
41 | 41 | Supply & fixing in replacement blade of aluminium as per sample kept in AGE office for blower motor of water cooler (any make, model & capacity) complete all as specified & directed by the Engineer-in-Charge | 7 | Each Set | |
42 | 42 | Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/35 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified .\nMake of fan motor:-Shriram / Polor/ Cool Home/ Frac Master\n | 3 | Each | |
43 | 43 | Supply and fixing in repair push cock (Stainless steel) of existing make and specifications for water cooler | 10 | Each | |
44 | 44 | Supply and fixing in repair thermostat for water cooler Make :- Indfoss/ Whirlpool/ Electrolux | 8 | Each | |
45 | 45 | Supply and fixing in repair relay with OLP suitable for water cooler. Make : Annapurna/ Hitachi/ Whirpool/ Godrej | 8 | Each | |
46 | 46 | Supply and fixing in repair running capacitor 36 MFD. Make : Tibcon/Sharda/Epcos/ Testla/ Siemens | 5 | Each | |
47 | 47 | Supply and fixing in repair capacitor 10 MFD Make : Tibcon/Sharda/Epcos/ Testla/ Siemens | 5 | Each | |
48 | 48 | Supply and fixing in repair capacitor 15 MFD (Running) Make : Tibcon/Sharda/Epcos/ Testla/ Siemens | 3 | Each | |
49 | 49 | Supply and fixing in repair capacitor 40/60 MFD (starting) Make : Tibcon/Sharda/Epcos/ Testla/ Siemens | 4 | Each | |
50 | 50 | Supply and fixing in replacement Cable 3 core, copper conductor size 40/0.0076 for water cooler all as specified. Make of cable:- Plaza/ Finolex / Kalinga/ Havells | 50 | RM | |
51 | 51 | REPAIR TO AIR CONDITIONERS | |||
52 | 52 | Taking out the unserviceable compressor from the air conditioner window/split type 2 ton capacity of any make & type and supply and fixing in replacement same capacity reconditioned compressor obtained from the factory out let make Kirloskar/ Tecumseh/ Carrier (with two year guarantee), including soldering of copper pipe, cleaning the refrigerant system, condenser tubing by vacuumisation, cleaning the system by CTC solution, pressure testing of the system, charging of refrigerant gas with R- 134 (a) gas and compressor oil in the system to its rated capacity including checking of leakage, replacement of foundation rubber pads , nut and bolts, including testing on full load complete all as specified and as directed by Engineer-in-Charge | 1 | Each Job | |
53 | 53 | All as per serial item No 52 here in before but for window type A/C 1.5 Ton capacity of any make | 2 | Each Job | |
54 | 54 | Material and labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for de-moistureing the system and gas charging by R-134 (a) upto the required pressure for 1.5 ton window/ split type air conditioner complete all as specified and directed by Engineer-in-charge | 2 | Each Job | |
55 | 55 | All as per serial item No 54 here in before but for window / Split type A/C 2 Ton capacity of any make | 1 | Each Job | |
56 | 56 | Taking down of old unserviceable fan motor of any capacity from the window type/ split type Air Conditioners 1.5/2 TR capacity and dismantling old and unserviceable burnt winding wire and rewinding with super enameled copper wire of existing gauge and size including heat varnishes replacement of shaft, bearing and bush complete as found unserviceable after opening complete all as specified and as directed. Make of winding wire: MILAN/ ATLAS/ CHETAK/ DEVIDAYAL (The unit rates quoted shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers insulating materials and clamps). | 2 | Each Job | |
57 | 57 | Taking down carefully window / split type AC 1.5/2.0 ton capacity, from its location and removing dirt and dust from interior and exterior of the Air conditioner and washing the condensor and evaporator with vami clean solution and other areas by soap solution, spraying pressurised water on condensor and evaporator with proper protection of electrical fixtures and connections, drying by blowing air, including replacement of air filter as per existing make and model, placing the window type air conditioner in its place all as specified and directed by Engineer-in-charge | 5 | Each Job | |
58 | 58 | Supply and fixing in repair capacitor 45 MFD (Running) Make : Tibcon/Sharda/Epcos/ Testla/ Siemens | 3 | Each | |
59 | 59 | Supply and fixing in repair capacitor 50 MFD Make : Tibcon/Sharda/Epcos/ Testla/ Siemens | 2 | Each | |
60 | 60 | REPAIR TO REFRIGERATORS | |||
61 | 61 | Taking down unserviceable compressor including bushes, grommets sleeves, washers, mounting rubbers, nuts, bolts, terminal cover, brazing and clips from existing refrigerators of Make : Voltas / Whirlpool/ Kelvinator/ Zenith/ MEC capacity 165/180/310 ltrs compete all as directed | 2 | Each Job | |
62 | 62 | Supply and fixing new compressor obtained from manufacturer or authorised dealer of Voltas / Whirlpool/ Kelvinator/ Zenith/ MEC alongwith test certificate and with Two year guarantee card, commissioning and testing on full load of new compressor including supply and charging of refrigerant gas in the system its rated capacity and including replacement of copper filter single capillary bushes, grommets, sleeves , washers , mounting rubbers nuts and bolts, terminal covers, brazing and clips of existing make and capacity in the existing refrigerator for 165/180 ltrs capacity complete all as directed by Engineer - in – Charge | 1 | Each Job | |
63 | 63 | All as per item No. 62 here-in-before but for 310 ltrs capacity of any make | 1 | Each Job | |
64 | 64 | Cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing refrigerators of 165/180/310 ltrs capacity of make and model as per existing complete all as specified and as directed | 3 | Each Job | |
65 | 65 | Taking down carefully the following accessories/ parts from existing refrigerator of any make for 165/180/310 liters capacity and in lieu providing new accessories / parts as per existing in the same refrigerators as under :- | |||
66 | 66 | Evaporator for 310 liters refrigerators of any make | 2 | Each | |
67 | 67 | Filter suitable for 310 liters of any make. | 2 | Each | |
68 | 68 | Capillary tubes of existing sizes of copper as per sample approved by Engineer-in-Charge | 2 | Each | |
69 | 69 | Supply and fixing in replacement thermostat for refrigerator 310 Ltr capacity Make Indfoss | 2 | Each | |
70 | 70 | Supply and fixing in replacement relay for refrigerator 310 Ltr capacity Make : Godrej/ Hi- Tech | 2 | Each | |
71 | 71 | Supply for replacement Vegetable tray for refrigerator of 165 Ltrs capacity as per sample approved by Engineer-in-Charge | 2 | Each | |
72 | 72 | Supply for replacement Vegetable tray for refrigerator of 240 Ltrs capacity as per sample approved by Engineer-in-Charge | 2 | Each | |
73 | 73 | Supply for replacement Vegetable tray for refrigerator of 310 Ltrs capacity as per sample approved by Engineer-in-Charge | 2 | Each | |
74 | 74 | Taking down carefully the following parts from the existing AC and in lieu providing new accessories/parts as per existing as under | |||
75 | 75 | Contactor for split AC | 5 | Each | |
76 | 76 | PCB of AC split/ window (1.5/2.00/3.00 ton) | 4 | Each | |
77 | 77 | Starting relay for AC | 5 | Each | |
78 | 78 | REPAIR TO DESERT COOLERS | |||
79 | 79 | Removing of old paint complete with emery paper and cleaning with scrapper and preparation of internal surfaces & bottom of the desert coolers of any size and apply one coat of black bituminous paint complete all as specified | 40 | Each Job | |
80 | 80 | Removing of old paint complete with emery paper and cleaning with scrapper and preparation of external surfaces including steel grills, side panel etc of the desert coolers of any size applying one coat of synthetic enamel paint complete all as specified | 40 | Each Job | |
81 | 81 | Taking down carefully old unserviceable water pumps and in lieu providing new submersible type water pump heavy duty of capacity 1/70 HP , 230 volts 50 HZ single phase complete all as specified. Make :- Khaitan/Poler/Cool home | 65 | Each Job | |
82 | 82 | Taking down carefully fan motor from existing desert coolers and in lieu providing new fan motor kit 1/6 to 1/8 HP 230 volts 50 HZ including replacement of mounting legs complete all as specified and directed. \nMake : Khaitan/ Crompton Greaves \n | 30 | Each Job | |
83 | 83 | Taking down carefully fan motor 1/6 to 1/8 HP 230 volts, 50 HZ, from existing desert coolers and refixing the same fan motor after rewinding with super enameled copper wire of existing size complete including replacement of mounting legs complete all as specified and directed by Engineer-in-Charge. Make of copper wire : MILAN/ ATLAS/ CHETAK/ DEVIDAYA | 15 | Each Job | |
84 | 84 | Taking down the following parts from the existing desert coolers in lieu providing new parts as per existing as under :- | |||
85 | 85 | Capacitor for desert cooler 4 MFD 230 volts Make: Asian/ Tibcon/ | 50 | Each | |
86 | 86 | PVC front grill including nuts bolts and washers suitable for 18/20” sweep desert coolers. Make Alka/Konark | 40 | Each | |
87 | 87 | Supply and fixing in replacement wood wool pads (set of three) weight not less than 500 gms superior quality complete all as directed by Engineer-in –Charge | 80 | Each Set | |
88 | 88 | Supply and fixing in replacement Supporting Jali for desert coolers \n( set of three )\n | 80 | Each Set | |
89 | 89 | Supply and fixing in replacement Plug top, 3 pin, 5 Amps, 230 Volts, ISI marked, complete all as specified and as directed by Engineer-in-Charge. Make : Anchor/MDS/Leader/ LEGRAND/HAVELLS | 30 | Each | |
90 | 90 | Supply and fixing in replacement Fan blade size of aluminium for desert cooler as as per sample approved by Engineer-in-Charge | 30 | Each Set | |
91 | 91 | Supply and fixing in replacement of PVC flexible pipe 15 mm dia of superior quality heavy duty suitable for desert cooler of any capacity complete all as directed by Engineer-in –Charge | 125 | RM | |
92 | 92 | Supply and fixing in replacement ball brass valves, high pressure, with polythene float and fly-nut (PTMT) complete, screwed for iron pipe or brass ferrule , suitable for 15mm bore pipe complete all specified and as directed.Make Prayag/ Polytuf | 8 | Each | |
93 | 93 | Repair to Geysers | |||
94 | 94 | Taking down and opening of the geysers 25/50 ltrs capacity storage type any make complete for inspection, descaling by chemical treatment of internal parts such as tank, base plate assembly (siphon system), heating element, etc re-assembling and refixing the same to its original position after testing on pressure complete all as directed by the Engineer-in-charge. \nNote:- Items such as glass wool, tank, siphon system, outer cover etc if found unserviceable under above item will be measured and paid for separately under its relevant item as supply only | 50 | Each Job | |
95 | 95 | S&F in replacement Thermostat switch ISI marked to Geysers 25/50 ltrs all as specified & directed by the Engineer-in-Charge. Make : Alert/Theta /Bajaj. | 35 | Each | |
96 | 96 | S&F in replacement siphon assembly suitable for Geysers 25 ltrs all as specified & directed by the Engineer-in-Charge. | 5 | Each | |
97 | 97 | S&F in replacement Low density polythene pipe (LDPE) connection arrangement with pipe of pressure rating 2.5 kgf/cm2 , 15 mm bore, 30 cm to 45 cm long with brass unions (Chromium plated) one on each side all as specified & directed by the Engineer-in-Charge. | 50 | Each | |
98 | 98 | S&F in replacement Plug and socket in sheet metal enclosure with 2 pin and earth plug and socket complete with and including MCB, SP, 20 Amps , 240 volts heavy duty all as specified.Make:-Legrand Cat Part 607851/ equivalent cat part No. in Hagger /L&T/ Standrad | 10 | Each | |
99 | 99 | S & F in replacement MCB suitable for 6 to 32 Amps, 240 Volt AC supply , SPN, with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make:- Anchor/MDS/Leader/ LEGRAND/HAVELLS | 25 | Each | |
100 | 100 | S & F in replacement heating element ISI Marked of rating 1.5 KW capacity including washers for 25 ltrs capacity Geysers all as specified.\nMake :- THETA/ ALERT | 15 | Each | |
101 | 101 | S & F in replacement heating element ISI Marked of rating 2 KW capacity including washers for 50 ltrs capacity Geysers all as specified.\nMake :- THETA/ ALERT | 25 | Each | |
102 | 102 | Supply and fixing in replacement Plug top, 3 pin, 15 Amps, 230 Volts, ISI marked, complete all as specified and as directed by Engineer-in-Charge. Make:- Anchor/MDS/Leader/ LEGRAND/HAVELLS | 20 | Each | |
103 | 103 | Supply and fixing in repair release valve suitable for 15 mm bore of pipe for 25/ 50 ltrs capacity Geysers, ISI marked all as specified.\nMake :- Jindal/Prakash/ UNIK/KS. | 15 | Each | |
104 | 104 | Supplied and fixed in repairs bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule suitable for 15mm bore GI pipe complete all as specified and as directed by Engineer-in-Charge.\nMake :- JAQUAR/PRAYAG/SIEKO/PARKO/ HINDWARE/MARC\n | 14 | Each |