Chemicals and Fertilizers Boards / Undertakings / PSU Closing in 0 days TDR #21457346

Annual Rate Contract For Maintenance Jobs At Instrument Section Of Tdp At Rcf , Trombay Unit . As Per Nit , Pg-Calibration Of Faulty Pressure Gauges . , Pg-Fixing Of Diaphragm Type Pressure Gauge With Isolation Valve . , Pg-Fixing Of Diaphragm & Capillary Type Pressure Gauge . , Pg-Replacement Of Defective Pressure Gauge & Defective Pg With Isolation Valve . Pg Removal And Shifting To Workshop . , Pg-Rectification Of Leakage For Pg Having Leakage From Pg Bottom Chamber Or From Gasket . , Pg-Rectification Of Leakage From Pg 1 / 2 Inch Process Connection . , Lg- Replacement / Rectification Defective Drain Valve Of Level Gauge & Fixing New Level Gauge Drain Valve & Removal , Cleaning And Fixing Back Of Level Gauge Scale . , Lg-Shifting Of Level Gauge From Stores To Site . , Lg-Flushing , De-Chocking And Cleaning Of Magnetic Level Gauge & Fixing Of Level Gauge After Rectification . , Lg-Removal , Cleaning And Replacement Of Deformed Float & Rectification Of Leakage Problem

Issued by Boards / Undertakings / PSU · RCF, Chembur, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Aug 2019
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
RCF, Chembur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Corrigendum - Annual Rate Contract For Maintenance Jobs At Instrument Section Of Tdp At Rcf , Trombay Unit . As Per Nit , Pg-Calibration Of Faulty Pressure Gauges . , Pg-Fixing Of Diaphragm Type Pressure Gauge With Isolation Valve . , Pg-Fixing Of Diaphragm & Capillary Type Pressure Gauge . , Pg-Replacement Of Defective Pressure Gauge & Defective Pg With Isolation Valve . Pg Removal And Shifting To Workshop . , Pg-Rectification Of Leakage For Pg Having Leakage From Pg Bottom Chamber Or From Gasket . , Pg-Rectification Of Leakage From Pg 1 / 2 Inch Process Connection . , Lg- Replacement / Rectification Defective Drain Valve Of Level Gauge & Fixing New Level Gauge Drain Valve & Removal , Cleaning And Fixing Back Of Level Gauge Scale . , Lg-Shifting Of Level Gauge From Stores To Site . , Lg-Flushing , De-Chocking And Cleaning Of Magnetic Level Gauge & Fixing Of Level Gauge After Rectification . , Lg-Removal , Cleaning And Replacement Of Deformed Float & Rectification Of Leakage Problem From Isolation Valve . , Lg-Fixing Of Plug At Lg Drain And Vent . , Lg-Replacement Of Guide Wire & Defective Float Of Float And Board Lgs , Lg-Pointer Relocation Of Float And Board Lgs , Magnetic Flow Meter- Fixing Of Mag Flow Meter At New Location . , Magnetic Flow Meter - Removal , Cleaning And Fixing Back Of Flow Tube . , Magnetic Flow Meter - Replacement Of Defective Converter & Checking And Programming Of Converter . , Magnetic Flow Meter -Cabling , Glanding And Termination Of Mag Flow Meter & Checking Of Flow Tube & Checking Calibration Of Mag Flow Using Simulator . , Magnetic Flow Meter -Rectification / Replacement Of Defective Earthing & Rectification Of Leakage Problem Of Mag Flow . , Magnetic Flow Meter - Replacement Of Defective Float Of Float And Board Lgs And Checking Of Flow Tube Using Simulator & Relocation , Modification And New Installation Of Mag Flow Meter , Control Valve- Overhauling Of Control Valve , Control Valve - Removal And Shifting Of Control Valve To Workshop For Maintenance & Rectification Of Butterfly Valve Body Leakage From The Shaft End Leakage . , Control Valve - Removal And Rectification Of Gland , Flange & Seat Leakage . , Control Valve - Replacement Of Defective Afr Of Control Valve . , Control Valve - Control Valve Fixing Calibration And Taking In Line Control Valve Removal , Cleaning And Shifting To Store . , Control Valve - Control Valve Cable Laying , Dressing , Glanding And Termination . , Control Valve - Relocation , Modification And New Installation Of Control Valve , Ult- Tank Manhole Cover Removal And Shifting To Mechanical Workshop For Providing Nozzle For Ult & Preparing Canopy For Ult And Fixing . . , Ult-Fixing , Cabling And Termination Of Ult , Ult Removal , Cleaning And Mounted Back , Cable Laying Dressing For Ult . Fixing , Cabling And Termination Of Local Indicator For Ult . , Ult-Mounting Of Ult With Still Well On The Tank . , Ult-Calibration Of Ult To Match Lg And Lt & Providing Extended Nozzle For Ult . Replacement Of Dplt With Ult . , Ult-Mounting Of Ult After Maintenance . , Ult-Relocation , Modification And New Installation Of Ult , Level Switch- Removal Cleaning And Replacement Of Deform Float & Cleaning And Rectification Of Sump Level Switch . , Level Switch- Dechoking Of Isolation Valve And Level Switch & Rectification Of Leakage From Drain Valve . , Level Switch - Replacement Of Defective Drain Valve . , Level Switch - Providing Plug At Drain And Vent . , Level Switch - Rectification Of Leakage From Drain Valve & Leakage From Level Switch Flange Joint . , Level Switch - Relocation , Modification And New Installation Of Level Switch , Dpft- Calibration Of Dpft & Isolating , Cleaning Of Ft Flange And Taking In Line . , Dpft- Impulse Line Cleaning . , Dpft- Power Resetting Of Ft And Taken In Line . & Adjusting Zero Shift . , Dplt- Calibration Of Dplt & Isolating , Cleaning Of Lt Flange And Taking In Line . , Dplt- Dechoking Of Isolation , Cleaning Of Lt Flange And Taking In Line . , Dplt- Cleaning Of Lt Cable And Reterminating & Power Resetting Of Lt And Taken In Line . , Dplt- Adjusting Zero Shift . , Radar Lt- Lt Removal , Cleaning And Shifting To Store & Checking Calibration Of Radar Lt . , Radar Lt- Lt Fixing , Glanding & Termination & Programming Of Radar Level Transmitter . , Radar Lt- Checking Calibration Of Radar Lt , Dcs- Replacement Of Defective Fan & Loop Checking Of Motor Control Loop . , Dcs- Updating Of Panel And Jb Wiring . , Dcs- Fixing Cable Ducts Cover After Cable Dressing & Replacement Of Defective Glass Fuse . , Dcs- Cleaning Of All The Panels And Consoles . , Dcs- Terminals Tightened In All Panels , Mounting Of Fuse Tb And Normal Tb & Wiring Job For Panel . , Dcs- Fixing Of Relay Panel , Diode Array Block & Mounting Of Isolators . , Pressure Switch- Replacement Of Defective Pressure Switch . , Pressure Switch- Pressure Switch Removal , Calibration And Fixing Back . , Telephone- Replacement Of Defective Telephone Set & Defective Hand Set Cable For Telephone . , Telephone- Repairing Of Defective Telephone Set . , Telephone- One New Telephone Connection Given With Telephone Set , Telephone Line Loop Checking & Shifting Of Telephone From Different Location . , Rotameter- Removal Of Rotameter , Cleaning And Fixing Back . , Rotameter - Rectification Of Flange Leakage Problem & Replacement Of Defective Rotameter . , Rotameter - Installation / Fixing , Glanding , Termination Of Rotameter . , Rotameter - Loop Checking Of Rotament For Control Room Indication . , Rotameter - Cabling , Dressing , Glanding And Termination For Rotameter . , Rotameter - Covering Rotameter With Polyethene & Removal , Cleaning And Shifting Of Rotameter To Store . , Ph- Checking Calibration Of Ph Transmitters , Ph- Rtd And Ph Meter Cabling To Converter . , Pc- Routine Checking Cleaning And Up Keeping Of Pc & Providing Printer And Installing In Pc . , Pc- Replacing Defective Monitor & Defective Mouse Of Computer . , Pc- Relocating Pc With Table From One Location To Another Location . , Others- Shifting Of Material And Instrument From One Location To Another & Material Shifting From Main Store To Plant . , Others - Shifting Of Cable Drums . , Others - Covering With Polyethene Sheet On Field Instrument For Rainy Season Protection . , Others - Pa System Arrangement In Meeting Hall . , Others - 6Mm & 12Mm Ss Tubing . , Others - Rectification , Fixing Of Air Filter Regulator & Rectification Of Push Button Problem Of Plant Pa System . , Others - Fixing Of Magnet Of Plant Pa System . , Others - Power Resetting Of Pa System & Maintenance Of Attendance System . , Others - Cleaning Jb & Field Instrument . , Others - Rectification , Programming And Resetting Of Fire Alarm System . , Others - Preparing And Fixing Aluminum Canopy For Field Instrument And Jb . , Others - Replacement Of Defective Solenoid Valve . , Others - Multi Core Cable , Drop Cable , Power Cable Laying Glanding And Termination , Others - Housekeeping Job For Instruments In Different Units .

AI Tender Summary

OUR REF NO 21457346
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 27-08-2019
Authority
Authority Name Rashtriya Chemicals And Fertilizers Limited
Work Description Corrigendum - Annual Rate Contract For Maintenance Jobs At Instrument Section Of Tdp At Rcf , Trombay Unit . As Per Nit , Pg-Calibration Of Faulty Pressure Gauges . , Pg-Fixing Of Diaphragm Type Pressure Gauge With Isolation Valve . , Pg-Fixing Of Diaphragm & Capillary Type Pressure Gauge . , Pg-Replacement Of Defective Pressure Gauge & Defective Pg With Isolation Valve . Pg Removal And Shifting To Workshop . , Pg-Rectification Of Leakage For Pg Having Leakage From Pg Bottom Chamber Or From Gasket . , Pg-Rectification Of Leakage From Pg 1 / 2 Inch Process Connection . , Lg- Replacement / Rectification Defective Drain Valve Of Level Gauge & Fixing New Level Gauge Drain Valve & Removal , Cleaning And Fixing Back Of Level Gauge Scale . , Lg-Shifting Of Level Gauge From Stores To Site . , Lg-Flushing , De-Chocking And Cleaning Of Magnetic Level Gauge & Fixing Of Level Gauge After Rectification . , Lg-Removal , Cleaning And Replacement Of Deformed Float & Rectification Of Leakage Problem From Isolation Valve . , Lg-Fixing Of Plug At Lg Drain And Vent . , Lg-Replacement Of Guide Wire & Defective Float Of Float And Board Lgs , Lg-Pointer Relocation Of Float And Board Lgs , Magnetic Flow Meter- Fixing Of Mag Flow Meter At New Location . , Magnetic Flow Meter - Removal , Cleaning And Fixing Back Of Flow Tube . , Magnetic Flow Meter - Replacement Of Defective Converter & Checking And Programming Of Converter . , Magnetic Flow Meter -Cabling , Glanding And Termination Of Mag Flow Meter & Checking Of Flow Tube & Checking Calibration Of Mag Flow Using Simulator . , Magnetic Flow Meter -Rectification / Replacement Of Defective Earthing & Rectification Of Leakage Problem Of Mag Flow . , Magnetic Flow Meter - Replacement Of Defective Float Of Float And Board Lgs And Checking Of Flow Tube Using Simulator & Relocation , Modification And New Installation Of Mag Flow Meter , Control Valve- Overhauling Of Control Valve , Control Valve - Removal And Shifting Of Control Valve To Workshop For Maintenance & Rectification Of Butterfly Valve Body Leakage From The Shaft End Leakage . , Control Valve - Removal And Rectification Of Gland , Flange & Seat Leakage . , Control Valve - Replacement Of Defective Afr Of Control Valve . , Control Valve - Control Valve Fixing Calibration And Taking In Line Control Valve Removal , Cleaning And Shifting To Store . , Control Valve - Control Valve Cable Laying , Dressing , Glanding And Termination . , Control Valve - Relocation , Modification And New Installation Of Control Valve , Ult- Tank Manhole Cover Removal And Shifting To Mechanical Workshop For Providing Nozzle For Ult & Preparing Canopy For Ult And Fixing . . , Ult-Fixing , Cabling And Termination Of Ult , Ult Removal , Cleaning And Mounted Back , Cable Laying Dressing For Ult . Fixing , Cabling And Termination Of Local Indicator For Ult . , Ult-Mounting Of Ult With Still Well On The Tank . , Ult-Calibration Of Ult To Match Lg And Lt & Providing Extended Nozzle For Ult . Replacement Of Dplt With Ult . , Ult-Mounting Of Ult After Maintenance . , Ult-Relocation , Modification And New Installation Of Ult , Level Switch- Removal Cleaning And Replacement Of Deform Float & Cleaning And Rectification Of Sump Level Switch . , Level Switch- Dechoking Of Isolation Valve And Level Switch & Rectification Of Leakage From Drain Valve . , Level Switch - Replacement Of Defective Drain Valve . , Level Switch - Providing Plug At Drain And Vent . , Level Switch - Rectification Of Leakage From Drain Valve & Leakage From Level Switch Flange Joint . , Level Switch - Relocation , Modification And New Installation Of Level Switch , Dpft- Calibration Of Dpft & Isolating , Cleaning Of Ft Flange And Taking In Line . , Dpft- Impulse Line Cleaning . , Dpft- Power Resetting Of Ft And Taken In Line . & Adjusting Zero Shift . , Dplt- Calibration Of Dplt & Isolating , Cleaning Of Lt Flange And Taking In Line . , Dplt- Dechoking Of Isolation , Cleaning Of Lt Flange And Taking In Line . , Dplt- Cleaning Of Lt Cable And Reterminating & Power Resetting Of Lt And Taken In Line . , Dplt- Adjusting Zero Shift . , Radar Lt- Lt Removal , Cleaning And Shifting To Store & Checking Calibration Of Radar Lt . , Radar Lt- Lt Fixing , Glanding & Termination & Programming Of Radar Level Transmitter . , Radar Lt- Checking Calibration Of Radar Lt , Dcs- Replacement Of Defective Fan & Loop Checking Of Motor Control Loop . , Dcs- Updating Of Panel And Jb Wiring . , Dcs- Fixing Cable Ducts Cover After Cable Dressing & Replacement Of Defective Glass Fuse . , Dcs- Cleaning Of All The Panels And Consoles . , Dcs- Terminals Tightened In All Panels , Mounting Of Fuse Tb And Normal Tb & Wiring Job For Panel . , Dcs- Fixing Of Relay Panel , Diode Array Block & Mounting Of Isolators . , Pressure Switch- Replacement Of Defective Pressure Switch . , Pressure Switch- Pressure Switch Removal , Calibration And Fixing Back . , Telephone- Replacement Of Defective Telephone Set & Defective Hand Set Cable For Telephone . , Telephone- Repairing Of Defective Telephone Set . , Telephone- One New Telephone Connection Given With Telephone Set , Telephone Line Loop Checking & Shifting Of Telephone From Different Location . , Rotameter- Removal Of Rotameter , Cleaning And Fixing Back . , Rotameter - Rectification Of Flange Leakage Problem & Replacement Of Defective Rotameter . , Rotameter - Installation / Fixing , Glanding , Termination Of Rotameter . , Rotameter - Loop Checking Of Rotament For Control Room Indication . , Rotameter - Cabling , Dressing , Glanding And Termination For Rotameter . , Rotameter - Covering Rotameter With Polyethene & Removal , Cleaning And Shifting Of Rotameter To Store . , Ph- Checking Calibration Of Ph Transmitters , Ph- Rtd And Ph Meter Cabling To Converter . , Pc- Routine Checking Cleaning And Up Keeping Of Pc & Providing Printer And Installing In Pc . , Pc- Replacing Defective Monitor & Defective Mouse Of Computer . , Pc- Relocating Pc With Table From One Location To Another Location . , Others- Shifting Of Material And Instrument From One Location To Another & Material Shifting From Main Store To Plant . , Others - Shifting Of Cable Drums . , Others - Covering With Polyethene Sheet On Field Instrument For Rainy Season Protection . , Others - Pa System Arrangement In Meeting Hall . , Others - 6Mm & 12Mm Ss Tubing . , Others - Rectification , Fixing Of Air Filter Regulator & Rectification Of Push Button Problem Of Plant Pa System . , Others - Fixing Of Magnet Of Plant Pa System . , Others - Power Resetting Of Pa System & Maintenance Of Attendance System . , Others - Cleaning Jb & Field Instrument . , Others - Rectification , Programming And Resetting Of Fire Alarm System . , Others - Preparing And Fixing Aluminum Canopy For Field Instrument And Jb . , Others - Replacement Of Defective Solenoid Valve . , Others - Multi Core Cable , Drop Cable , Power Cable Laying Glanding And Termination , Others - Housekeeping Job For Instruments In Different Units .
Basic Detail
Tender No 2019_RCFL_492063_1
Bidding Type Tender
Location
City RCF, Chembur
State Maharashtra
Key Dates
Publish Date 06 Aug 2019
Submission Date 27 Aug 2019
Open Date 27 Aug 2019
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
3E783A24-4CB6-498E-808C-CF84D16DE32D.html
Tendernotice_1.pdf
BOQ_515355.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 06, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 27, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

3E783A24-4CB6-498E-808C-CF84D16DE32D.html

pdf

Tendernotice_1.pdf

xls

BOQ_515355.xls

TenderDetail
Loading tenders