| 1 | 1.01 | SUPPLY & INSTALLATION OF 1.5 TR COMP\nLong Text:\nSupply & Installation of Scroll/Reciprocating/Rotary Compressor for 1.5TR split type AC. The work includes supply and installation of compressor, refrigerant gas filling, brazing to copper piping connection etc. The supply of new compressor is in the scope of Vendor. \nMakes- LG/EMERSON/DAIKIN/DONTOSS/HITACHI/TECUMSEH | Nil1 | 12 | EA |
|---|
| 2 | 1.02 | SUPPLY & INSTALLATION OF 2 TR COMP\nLong Text:\nSupply & Installation of Scroll/Reciprocating/Rot ary Compressor for 2TR split type AC. The work includes supply and installation of compressor, refrigerant gas filling, brazing to copper piping connection etc. The supply of new compressor is in the scope of Vendor.\nMakes-LG/EMERSON/DAIKIN/DONTOSS/HITACHI/TECUMSEH | Nil2 | 6 | EA |
|---|
| 3 | 1.03 | SUPPLY & INSTALLATION OF 4 TR COMP\nLong Text:\nSupply & Installation of Scroll/Reciprocating/Rot ary Compressor for 4TR, Voltas make Tower type AC. The work includes supply and installation of compressor, refrigerant gas filling, brazing to copper piping connection etc. The supply of new compressor is in the scope of Vendor. \nMakes-LG/EMERSON/DAIKIN/DONTOSS/HITACHI/TECUMSEH | Nil3 | 4 | EA |
|---|
| 4 | 1.04 | SUPPLY & INSTALLATION OF 1.5 TR BODY KIT\nLong Text:\nSupply & installation of 1.5 Ton complete Body Kit of Split type Air Conditioner without compressor | Nil4 | 5 | EA |
|---|
| 5 | 1.05 | SUPPLY & INSTALLATION OF 2 TR BODY KIT\nLong Text:\nSupply & installation of 2 Ton complete Body Kit of Split type Air Conditioner without compressor | Nil5 | 5 | EA |
|---|
| 6 | 1.06 | SUPPLY & INSTALLATION OF 4 TR BODY KIT\nLong Text:\nSupply & installation of 4 Ton complete Body Kit of tower type Air Conditioner without compressor | Nil6 | 5 | EA |
|---|
| 7 | 1.07 | SUPPLY & CHARGING OF R-22 GAS\nLong Text:\nSupply & charging of R-22 refrigerant gas in case of low pressure & leakage of refrigerant gas in 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower air conditioners. This work shall have guarantee for six months followed by a leak test | Nil7 | 100 | KG |
|---|
| 8 | 1.08 | ATTENDING & RECTIFYING PROBLEM OF AC\nLong Text:\nAttending & rectifying the problem including attending all complaints of the 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower A/Cs and rectifying it. During the maintenance the air filter shall be cleaned | Nil8 | 10 | EA |
|---|
| 9 | 1.09 | DRY CLEANING OF 1.5/2/4 TR AC\nLong Text:\nDry Cleaning of 1.5/ 2.0TR/3.0TR/4.0 TR Split/window/Tower/cassette Air Conditioners including filter with cooling and condenser coils | Nil9 | 40 | EA |
|---|
| 10 | 1.1 | OVERHAULING/WET SERVICING\nLong Text: \nOverhauling / wet servicing the work includes complete overhauling of the 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0TR Tower A/Cs during the maintenance the unit shall be thoroughly cleaned with water & detergents. All power and control circuit wiring shall be checked. | Nil10 | 10 | EA |
|---|
| 11 | 1.11 | INSTALLATION OF 1.5/2/4 TR AC\nLong Text:\nInstallation of 1.5/2.0 Ton split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners : The work includes lifting & shifting, installation at it's existing foundation,fixing of out door and indoor unit, leak testing, Pipe brazing, gas charging & testing of 1.5 TR split A/C to restore it in normal working condition. Foundation shall be prepared by the BCPL. Also battery trolley shall be provided | Nil11 | 5 | EA |
|---|
| 12 | 1.12 | SUPPLY OF STARTING CAPACITOR\nLong Text:\nSupply of Starting Capacitor 80-100 MFD for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty starting capacitor and installation of new starting capacitor 80-100 MFD & testing of air conditioners. | Nil12 | 20 | EA |
|---|
| 13 | 1.13 | SUPPLY OF RUNNING CAPACITOR\nLong Text:\nSupply of Running Capacitor 36-80 MFD for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty running capacitor, installation of new running capacitor & testing of air conditioners. | Nil13 | 20 | EA |
|---|
| 14 | 1.14 | SUPPLY OF STARTING RELAY\nLong Text:\nSupply of Starting Relay for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty starting relay, installation of new starting relay & testing\nof air conditioners. | Nil14 | 20 | EA |
|---|
| 15 | 1.15 | SUPPLY OF THERMOSTAT FOR 1.5/2/4 TR AC\nLong Text:\nSupply of Thermostat for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Thermostat, installation of new Thermostat & testing of air conditioners. | Nil15 | 10 | EA |
|---|
| 16 | 1.16 | SUPPLY OF OVERLOAD RELAY\nLong Text:\nSupply of Overload Relay for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty overload relay, installation of new overload relay & testing of air conditioners. | Nil16 | 15 | EA |
|---|
| 17 | 1.17 | REPAIRING OF OUTDOOR FAN MOTOR\nLong Text:\nRepairing of Outdoor fan motor for 3 TR cassette type air conditioner and\n4.0 TR Tower Air Conditioners. The work includes replacement of faulty Outdoor fan motor, installation of new Outdoor fan motor of split A/C & testing of air conditioners. | Nil17 | 10 | EA |
|---|
| 18 | 1.18 | SUPPLY OF OUTDOOR FAN BLADE\nLong Text:\nSupply of Outdoor fan blade of split A/C for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Outdoor fan blade of split A/C, installation of new Outdoor fan blade of split A/C & testing of air conditioners. | Nil18 | 20 | EA |
|---|
| 19 | 1.19 | REPAIRING OF INDOOR FAN/BLOWE MOTOR\nLong Text:\nRepairing of In door fan/blower motor for 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty In door fan/blower motor of split A/C, installation of new In door fan/blower motor of split A/C & testing of air conditioners. | Nil19 | 10 | EA |
|---|
| 20 | 1.2 | REPAIRING OF IN DOOR BLOWER OF 1.5/2 TR\nLong Text:\nRepairing of In door blower of split A/C for 1.5/2.0 TR split air conditioners. The work includes replacement of faulty In door blower of split A/C, installation of new In door blower of split A/C & testing of air conditioners. | Nil20 | 25 | EA |
|---|
| 21 | 1.21 | SUPPLY OF AIR FILTER OF SPLIT AC\nLong Text:\nSupply of Air filter of split A/C for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Air filter of split A/C, installation of new Air filter of split A/C & testing of air conditioners. | Nil21 | 20 | EA |
|---|
| 22 | 1.22 | SUPPLY OF CONTROL PCB OF SPLIT AC\nLong Text:\nSupply of Control PCB of split A/C for 1.5/2.0 TR split air conditioners,\n3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Control PCB of split A/C, installation of new Control PCB of split A/C & testing of air conditioners. | Nil22 | 10 | EA |
|---|
| 23 | 1.23 | SUPPLY OF FRONT GRILL OF SPLIT AC\nLong Text:\nSupply of Front grill of split A/C for 1.5/2.0 TR split air conditioners,\n3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Front grill of split A/C, installation of new Front grill of split A/C & testing of air conditioners. | Nil23 | 10 | EA |
|---|
| 24 | 1.24 | SUPPLY OF FAN MOTOR RUBBER PAD\nLong Text:\nSupply of Fan motor rubber pad for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Fan motor rubber pad, installation of new Fan motor rubber pad & testing of air conditioners. | Nil24 | 10 | EA |
|---|
| 25 | 1.25 | SUPPLY OF COMPRESSOR RUBBER PAD\nLong Text:\nSupply of Compressor rubber pad for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Compressor rubber pad, installation of new Compressor rubber pad & testing of air conditioners. | Nil25 | 15 | EA |
|---|
| 26 | 1.26 | SUPPLY OF GAS FILTER\nLong Text:\nSupply of Gas filter for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Gas filter, installation of Gas filter & testing of air conditioners. | Nil26 | 15 | M |
|---|
| 27 | 1.27 | SUPPLY OF DRAIN PIPE FOR 1.5/2/4TR AC\nLong Text:\nSupply of Drain Pipe for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Drain Pipe, installation of new Drain Pipe & testing of air conditioners. | Nil27 | 15 | EA |
|---|
| 28 | 1.28 | SUPPLY OF CAPILLARY TUBES\nLong Text:\nSupply of Capillary tubes for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Capillary tubes, installation of new Capillary tubes & testing of air conditioners. | Nil28 | 15 | EA |
|---|
| 29 | 1.29 | SUPPLY OF COPPER TUBES 1/4\" DIA\nLong Text:\nSupply of Copper tubes 1/4#DIA for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Copper tubes 1/4#DIA, installation of new Copper tubes 1/4#DIA & testing of air conditioners. | Nil29 | 10 | M |
|---|
| 30 | 1.3 | SUPPLY OF COPPER TUBES 3/8\" DIA\nLong Text:\nSupply of Copper tubes 3/8#DIA for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Copper tubes 3/8#DIA, installation of new Copper tubes 3/8#DIA & testing of air conditioners. | Nil30 | 10 | M |
|---|
| 31 | 1.31 | SUPPLY OF COPPER TUBES 1/2\" DIA\nLong Text:\nSupply of Copper tubes 1/2#DIA for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Copper tubes 1/2#DIA, installation of new Copper tubes 1/2#DIA & testing of air conditioners. | Nil31 | 20 | M |
|---|
| 32 | 1.32 | SUPPLY OF COPPER TUBES 5/8\" DIA\nLong Text:\nSupply of Copper tubes 5/8#DIA for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Copper tubes 5/8#DIA, installation of new Copper tubes 5/8#DIA & testing of air conditioners. | Nil32 | 10 | M |
|---|
| 33 | 1.33 | SUPPLY OF SPLIT A/C'S PIPING INSULATION\nLong Text:\nSupply of Split A/Cs piping insulation cover of In-door and Out door unit pipes for 1.5/2.0 TR split air conditioners, 3 TR cassette type air conditioner and 4.0 TR Tower Air Conditioners. The work includes replacement of faulty Split A/Cs piping insulation cover of In-door and Out door unit pipes, installation of new Split A/Cs piping insulation cover of In-door and Out door unit pipes & testing of air conditioners. | Nil33 | 120 | M |
|---|
| 34 | 1.34 | SUPPLY OF NRV FOR SUCTION/DISCHARGE\nLong Text:\nSupply NRV for A/C suction/discharge tube | Nil34 | 10 | EA |
|---|
| 35 | 2.01 | SUPPLY & CHARGING OF R-134A REFRIGERANT\nLong Text:\nSupply and charging of R-134A Refrigerant gas in case of low pressure & leakage of refrigerant gas in refrigerators capacity ranging from 165-320 ltr and deep freezer(300 ltrs). This work valid for six months followed by a leak test. | Nil35 | 20 | KG |
|---|
| 36 | 2.02 | SUPPLY & INSTALLATION OF NEW COMP 300L\nLong Text:\nSupply & installation of new compressor including supply of R-134 Gas & charging for 300 ltr deep freezer . The work includes replacement of faulty compressor, installation of new compressor. \nMakes-LG/EME RSON/DAIKIN/DONTOSS/HITACHI/TECUMSEH | Nil36 | 2 | EA |
|---|
| 37 | 2.03 | SUPPLY & INSTALLATION OF NEW COMP, 320L\nLong Text:\nSupply & installation of new compressor including supply of R-134 Gas for\n320 ltr deep freezer/REFRIGERATOR. The work includes replacement of faulty compressor, installation of new compressor.\nMakes-LG/EMERSON/DAIKIN/DONTOSS/HITACHI/TECUMSEH | Nil37 | 1 | EA |
|---|
| 38 | 2.04 | SUPPLY & INSTALLATION OF NEW COMP 165 L\nLong Text:\nSupply & installation of new compressor including supply of R-134 Gas & charging for 165 ltr deep freezer. The work includes replacement of faulty compressor, installation of new compressor. \nMakes-LG/EME RSON/DAIKIN/DONTOSS/HITACHI/TECUMSEH | Nil38 | 4 | EA |
|---|
| 39 | 2.05 | SUPPLY OF O/L RELAY\nLong Text:\nSupply of Overload Relay of deep freezer/refrigerator capacity ranging from\n165-320 ltr. refrigerator/deep freezer. | Nil39 | 3 | EA |
|---|
| 40 | 2.06 | SUPPLY OF MOTOR FOR DEEP FREEZER/REFRIGERATOR\nLong Text:\nSupply of motor for refrigerator /deep freezer capacity ranging from 165-320 ltr. The work includes replacement of faulty motor, installation of new motor & testing of refrigerator/deep freezer. | Nil40 | 3 | EA |
|---|