Purvanchal Vidyut Vitaran Nigam Limited has published Repairing Of Damaged Transformers Etc. Submission Date for this Tender is 28-08-2019. Bushings Tenders in Varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: Repair of Copper Wound 5 MVA, 8 MVA and 10 MVA 33/11KV transformers | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Repairing of 5 MVA Transformers | |||
2 | 1.01 | Labour charges for Preliminary inspection of transformers at PVVNL site/ workshop involving minor repairs at site/workshop. | item1 | 100 | Per T/f |
3 | 1.02 | Labour charges for Pre-inspection of transformers at PuVVNL site/ workshop for estimation involving major repairs unloading of T/f at Contractor's works & repair of T/f, as detailed below:-\nOpening of transformer cover, draining of oil, if any de-tanking core and coil assembly, and replacement of damaged parts, minor repair of core and tank (if required). Cleaning washing of dust & dirt etc. from all parts including core tank, Cooling tubes of radiators, removal of damaged parts, requiring replacement, fitting, fixing of new parts making connection and assembly complete in all respects, re-tanking after repairs, filling fresh transformer oil, making transformer ready for tests & testing for all tests as per clause 16.0 of Technical specification.\n | item2 | 100 | Per T/f |
4 | 1.03 | HV leg coils complete with insulation varnishing by vacuum impregnation (if required as per sample) and baking of coil assembly. | item3 | 120000 | Per KG |
5 | 1.04 | LV leg coils complete with insulation varnishing by vacuum impregnation (if required as per sample) and baking of coil assembly. | item4 | 80000 | Per KG |
6 | 1.05 | HV bushing 33/37.5 KV | item5 | 300 | Each |
7 | 1.06 | LV bushing 11 KV | item6 | 400 | Each |
8 | 1.07 | HV bushing metal parts | item7 | 300 | Each |
9 | 1.08 | LV bushing metal parts | item8 | 400 | Each |
10 | 1.09 | Set of gaskets (rubberized cork) | item9 | 100 | Each |
11 | 1.1 | Silicagel Breather with fresh silicagel | item10 | 100 | Each |
12 | 1.11 | Magnetic type oil level gauge with low level alarm contact. | item11 | 100 | Each |
13 | 1.12 | Tapping switch 33,37.5 KV complete with handle. | item12 | 100 | Each |
14 | 1.13 | Tapping Switch handle. | item13 | 100 | Each |
15 | 1.14 | Oil drain valve incorporating sampling device (with narrow orifice) & having suitable arrangement for locking. | item14 | 200 | Each |
16 | 1.15 | Filter Valve. | item15 | 200 | Each |
17 | 1.16 | Dial type thermometer of 150 mm dia with max. temp. indicator complete with resetting device and alarm contacts etc. | item16 | 100 | Each |
18 | 1.17 | Double float bucholz relay complete with resetting device and alarm contacts etc. | item17 | 100 | Each |
19 | 1.18 | Air release plug. | item18 | 300 | Each |
20 | 1.19 | Replacement of damaged core and lamination. | item19 | 100000 | Per KG |
21 | 1.2 | Pair of arcing Horn 33,37.5 KV | item20 | 700 | Per Pair |
22 | 1.21 | Radiator Valve | item21 | 400 | Per Unit |
23 | 1.22 | Replacement of OLTC contact. | item22 | 100 | Lump Sum |
24 | 1.23 | Replacement of OLTC Terminal barrier board | item23 | 100 | Lump Sum |
25 | 1.24 | Replacement of gaskets, lubrication of mechanical system. | item24 | 100 | Lump Sum |
26 | 1.25 | M.S. Clamping Rings. | item25 | 200 | Per T/f |
27 | 1.26 | Winding Temperature indicator (complete set) | item26 | 100 | Per Unit |
28 | 1.27 | Fresh transformer oil of standard quality as per IS: 335/83 and latest amendment thereof. | item27 | 250000 | per ltr |
29 | 1.28 | Sundry item viz. cover bolts plug caps, screw washers, insulation materials minor repairs of tank other parts required if any, Aluminium Name Plate etc. | item28 | 100 | Per T/f |
30 | 1.29 | Painting inside & outside of transformer including radiator tubes, conservator with suitable primer and two coats of suitable paint of dark green colour and marking etc. | item29 | 100 | Per T/f |
31 | 1.3 | Burnt/Damaged leg coils to be retained by the contractor. | item30 | 200000 | Per KG |
32 | 1.31 | Damaged metal parts of bushing to be retained by contractor (copper & brass). | item31 | 600 | Per KG |
33 | 1.32 | Transportation of damaged Transformer from site/store to contractors works upto 25 Km. | item32 | 100 | Per T/f |
34 | 1.33 | Transportaion of damaged Transformer from site/store to contractors works Above 25 Km. to 50 Km. | item33 | 100 | Per T/f |
35 | 1.34 | Transportaion of damaged Transformer from site/store to contractors works Above 50 Km. to 100 Km. | item34 | 100 | Per T/f |
36 | 1.35 | Transportaion of damaged Transformer from site/store to contractors works Above 100 Km. to 200 Km. | item35 | 100 | Per T/f |
37 | 1.36 | Transportaion of damaged Transformer from site/store to contractors works Above 200 Km. to 300 Km. | item36 | 100 | Per T/f |
38 | 1.37 | Transportaion of damaged Transformer from site/store to contractors works Above 300 Km. | item37 | 100 | Per T/f |
39 | 1.38 | Transportaion of repaired Transformer from contraactors works to site/store upto 25 Km. | item38 | 100 | Per T/f |
40 | 1.39 | Transportaion of repaired Transformer from contraactors works to site/store Above 25 Km. to 50 Km. | item39 | 100 | Per T/f |
41 | 1.4 | Transportaion of repaired Transformer from contraactors works to site/store Above 50 Km. to 100 Km. | item40 | 100 | Per T/f |
42 | 1.41 | Transportaion of repaired Transformer from contraactors works to site/store Above 100 Km. to 200 Km. | item41 | 100 | Per T/f |
43 | 1.42 | Transportaion of repaired Transformer from contraactors works to site/store Above 200 Km. to 300 Km. | item42 | 100 | Per T/f |
44 | 1.43 | Transportaion of repaired Transformer from contraactors works to site/store Above 300 Km. | item43 | 100 | Per T/f |
45 | 2 | Repairing of 8 MVA Transformers | |||
46 | 2.01 | Labour charges for Preliminary inspection of transformers at PVVNL site/ workshop involving minor repairs at site/workshop. | item 44 | 20 | Per T/f |
47 | 2.02 | Labour charges for Pre-inspection of transformers at PuVVNL site/ workshop for estimation involving major repairs unloading of T/f at Contractor's works & repair of T/f, as detailed below:-\nOpening of transformer cover, draining of oil, if any de-tanking core and coil assembly, and replacement of damaged parts, minor repair of core and tank (if required). Cleaning washing of dust & dirt etc. from all parts including core tank, Cooling tubes of radiators, removal of damaged parts, requiring replacement, fitting, fixing of new parts making connection and assembly complete in all respects, re-tanking after repairs, filling fresh transformer oil, making transformer ready for tests & testing for all tests as per clause 16.0 of Technical specification.\n | item 45 | 20 | Per T/f |
48 | 2.03 | HV leg coils complete with insulation varnishing by vacuum impregnation (if required as per sample) and baking of coil assembly. | item 46 | 28000 | Per KG |
49 | 2.04 | LV leg coils complete with insulation varnishing by vacuum impregnation (if required as per sample) and baking of coil assembly. | item 47 | 19200 | Per KG |
50 | 2.05 | HV bushing 33/37.5 KV | item 48 | 60 | Each |
51 | 2.06 | LV bushing 11 KV | item 49 | 80 | Each |
52 | 2.07 | HV bushing metal parts | item 50 | 60 | Each |
53 | 2.08 | LV bushing metal parts | item 51 | 80 | Each |
54 | 2.09 | Set of gaskets (rubberized cork) | item 52 | 20 | Each |
55 | 2.1 | Silicagel Breather with fresh silicagel | item 53 | 20 | Each |
56 | 2.11 | Magnetic type oil level gauge with low level alarm contact. | item 54 | 20 | Each |
57 | 2.12 | Tapping switch 33,37.5 KV complete with handle. | item 55 | 20 | Each |
58 | 2.13 | Tapping Switch handle. | item 56 | 20 | Each |
59 | 2.14 | Oil drain valve incorporating sampling device (with narrow orifice) & having suitable arrangement for locking. | item 57 | 40 | Each |
60 | 2.15 | Filter Valve. | item 58 | 40 | Each |
61 | 2.16 | Dial type thermometer of 150 mm dia with max. temp. indicator complete with resetting device and alarm contacts etc. | item 59 | 20 | Each |
62 | 2.17 | Double float bucholz relay complete with resetting device and alarm contacts etc. | item 60 | 20 | Each |
63 | 2.18 | Air release plug. | item 61 | 60 | Each |
64 | 2.19 | Replacement of damaged core and lamination. | item 62 | 24000 | Per KG |
65 | 2.2 | Pair of arcing Horn 33,37.5 KV | item 63 | 140 | Per Pair |
66 | 2.21 | Radiator Valve | item 64 | 80 | Per Unit |
67 | 2.22 | Replacement of OLTC contact. | item 65 | 20 | Lump Sum |
68 | 2.23 | Replacement of OLTC Terminal barrier board | item 66 | 20 | Lump Sum |
69 | 2.24 | Replacement of gaskets, lubrication of mechanical system. | item 67 | 20 | Lump Sum |
70 | 2.25 | M.S. Clamping Rings. | item 68 | 40 | Per T/f |
71 | 2.26 | Winding Temperature indicator (complete set) | item 69 | 20 | Per Unit |
72 | 2.27 | Fresh transformer oil of standard quality as per IS: 335/83 and latest amendment thereof. | item 70 | 58000 | per ltr |
73 | 2.28 | Sundry item viz. cover bolts plug caps, screw washers, insulation materials minor repairs of tank other parts required if any, Aluminium Name Plate etc. | item 71 | 20 | Per T/f |
74 | 2.29 | Painting inside & outside of transformer including radiator tubes, conservator with suitable primer and two coats of suitable paint of dark green colour and marking etc. | item 72 | 20 | Per T/f |
75 | 2.3 | Burnt/Damaged leg coils to be retained by the contractor. | item 73 | 48000 | Per KG |
76 | 2.31 | Damaged metal parts of bushing to be retained by contractor (copper & brass). | item 74 | 120 | Per KG |
77 | 2.32 | Transportation of damaged Transformer from site/store to contractors works upto 25 Km. | item 75 | 20 | Per T/f |
78 | 2.33 | Transportaion of damaged Transformer from site/store to contractors works Above 25 Km. to 50 Km. | item 76 | 20 | Per T/f |
79 | 2.34 | Transportaion of damaged Transformer from site/store to contractors works Above 50 Km. to 100 Km. | item 77 | 20 | Per T/f |
80 | 2.35 | Transportaion of damaged Transformer from site/store to contractors works Above 100 Km. to 200 Km. | item 78 | 20 | Per T/f |
81 | 2.36 | Transportaion of damaged Transformer from site/store to contractors works Above 200 Km. to 300 Km. | item 79 | 20 | Per T/f |
82 | 2.37 | Transportaion of damaged Transformer from site/store to contractors works Above 300 Km. | item 80 | 20 | Per T/f |
83 | 2.38 | Transportaion of repaired Transformer from contraactors works to site/store upto 25 Km. | item 81 | 20 | Per T/f |
84 | 2.39 | Transportaion of repaired Transformer from contraactors works to site/store Above 25 Km. to 50 Km. | item 82 | 20 | Per T/f |
85 | 2.4 | Transportaion of repaired Transformer from contraactors works to site/store Above 50 Km. to 100 Km. | item 83 | 20 | Per T/f |
86 | 2.41 | Transportaion of repaired Transformer from contraactors works to site/store Above 100 Km. to 200 Km. | item 84 | 20 | Per T/f |
87 | 2.42 | Transportaion of repaired Transformer from contraactors works to site/store Above 200 Km. to 300 Km. | item 85 | 20 | Per T/f |
88 | 2.43 | Transportaion of repaired Transformer from contraactors works to site/store Above 300 Km. | item 86 | 20 | Per T/f |
89 | 3 | Repairing of 10 MVA Transformers | |||
90 | 3.01 | Labour charges for Preliminary inspection of transformers at PVVNL site/ workshop involving minor repairs at site/workshop. | item87 | 30 | Per T/f |
91 | 3.02 | Labour charges for Pre-inspection of transformers at PuVVNL site/ workshop for estimation involving major repairs unloading of T/f at Contractor's works & repair of T/f, as detailed below:-\nOpening of transformer cover, draining of oil, if any de-tanking core and coil assembly, and replacement of damaged parts, minor repair of core and tank (if required). Cleaning washing of dust & dirt etc. from all parts including core tank, Cooling tubes of radiators, removal of damaged parts, requiring replacement, fitting, fixing of new parts making connection and assembly complete in all respects, re-tanking after repairs, filling fresh transformer oil, making transformer ready for tests & testing for all tests as per clause 16.0 of Technical specification.\n | item88 | 30 | Per T/f |
92 | 3.03 | HV leg coils complete with insulation varnishing by vacuum impregnation (if required as per sample) and baking of coil assembly. | item89 | 51000 | Per KG |
93 | 3.04 | LV leg coils complete with insulation varnishing by vacuum impregnation (if required as per sample) and baking of coil assembly. | item90 | 33000 | Per KG |
94 | 3.05 | HV bushing 33/37.5 KV | item91 | 90 | Each |
95 | 3.06 | LV bushing 11 KV | item92 | 120 | Each |
96 | 3.07 | HV bushing metal parts | item93 | 90 | Each |
97 | 3.08 | LV bushing metal parts | item94 | 120 | Each |
98 | 3.09 | Set of gaskets (rubberized cork) | item95 | 30 | Each |
99 | 3.1 | Silicagel Breather with fresh silicagel | item96 | 30 | Each |
100 | 3.11 | Magnetic type oil level gauge with low level alarm contact. | item97 | 30 | Each |
101 | 3.12 | Tapping switch 33,37.5 KV complete with handle. | item98 | 30 | Each |
102 | 3.13 | Tapping Switch handle. | item99 | 30 | Each |
103 | 3.14 | Oil drain valve incorporating sampling device (with narrow orifice) & having suitable arrangement for locking. | item100 | 60 | Each |
104 | 3.15 | Filter Valve. | item101 | 60 | Each |
105 | 3.16 | Dial type thermometer of 150 mm dia with max. temp. indicator complete with resetting device and alarm contacts etc. | item102 | 30 | Each |
106 | 3.17 | Double float bucholz relay complete with resetting device and alarm contacts etc. | item103 | 30 | Each |
107 | 3.18 | Air release plug. | item104 | 90 | Each |
108 | 3.19 | Replacement of damaged core and lamination. | item105 | 42000 | Per KG |
109 | 3.2 | Pair of arcing Horn 33,37.5 KV | item106 | 210 | Per Pair |
110 | 3.21 | Radiator Valve | item107 | 120 | Per Unit |
111 | 3.22 | Replacement of OLTC contact. | item108 | 30 | Lump Sum |
112 | 3.23 | Replacement of OLTC Terminal barrier board | item109 | 30 | Lump Sum |
113 | 3.24 | Replacement of gaskets, lubrication of mechanical system. | item110 | 30 | Lump Sum |
114 | 3.25 | M.S. Clamping Rings. | item111 | 60 | Per T/f |
115 | 3.26 | Winding Temperature indicator (complete set) | item112 | 30 | Per Unit |
116 | 3.27 | Fresh transformer oil of standard quality as per IS: 335/83 and latest amendment thereof. | item113 | 147000 | per ltr |
117 | 3.28 | Sundry item viz. cover bolts plug caps, screw washers, insulation materials minor repairs of tank other parts required if any, Aluminium Name Plate etc. | item114 | 30 | Per T/f |
118 | 3.29 | Painting inside & outside of transformer including radiator tubes, conservator with suitable primer and two coats of suitable paint of dark green colour and marking etc. | item115 | 30 | Per T/f |
119 | 3.3 | Burnt/Damaged leg coils to be retained by the contractor. | item116 | 84000 | Per KG |
120 | 3.31 | Damaged metal parts of bushing to be retained by contractor (copper & brass). | item117 | 180 | Per KG |
121 | 3.32 | Transportation of damaged Transformer from site/store to contractors works upto 25 Km. | item118 | 30 | Per T/f |
122 | 3.33 | Transportaion of damaged Transformer from site/store to contractors works Above 25 Km. to 50 Km. | item119 | 30 | Per T/f |
123 | 3.34 | Transportaion of damaged Transformer from site/store to contractors works Above 50 Km. to 100 Km. | item120 | 30 | Per T/f |
124 | 3.35 | Transportaion of damaged Transformer from site/store to contractors works Above 100 Km. to 200 Km. | item121 | 30 | Per T/f |
125 | 3.36 | Transportaion of damaged Transformer from site/store to contractors works Above 200 Km. to 300 Km. | item122 | 30 | Per T/f |
126 | 3.37 | Transportaion of damaged Transformer from site/store to contractors works Above 300 Km. | item123 | 30 | Per T/f |
127 | 3.38 | Transportaion of repaired Transformer from contraactors works to site/store upto 25 Km. | item124 | 30 | Per T/f |
128 | 3.39 | Transportaion of repaired Transformer from contraactors works to site/store Above 25 Km. to 50 Km. | item125 | 30 | Per T/f |
129 | 3.4 | Transportaion of repaired Transformer from contraactors works to site/store Above 50 Km. to 100 Km. | item126 | 30 | Per T/f |
130 | 3.41 | Transportaion of repaired Transformer from contraactors works to site/store Above 100 Km. to 200 Km. | item127 | 30 | Per T/f |
131 | 3.42 | Transportaion of repaired Transformer from contraactors works to site/store Above 200 Km. to 300 Km. | item128 | 30 | Per T/f |
132 | 3.43 | Transportaion of repaired Transformer from contraactors works to site/store Above 300 Km. | item129 | 30 | Per T/f |