Replacement Of Old Electrical Panel By Cubical Panel Board With All ( E / M ) Equipment At C-3 Sda Bps . , Dismantling Of Old Panel , Structure , Damaged Components And Installation Of The Panel At Site By Making Foundation , Termination Of Cable Both Incoming & Out Going Side , Mongering Of Complete Panel , Including Cable Connection , Thgis Includes Cartage , Loading & Unloading Etc . , Lt Distribution Panel Sheet Steel Enclosure Made Out Of 2Mm Crca Sheet Totally Enclosed , Powder Coated Free Standing , Floor Mounted Type , Dust& Vermin Proof , Outward Opening , Lockable Doors Having Hidden Hinges And A Bolted Back Cover Both Using Non-Deteriorating Neoprene Rubber Gaskets To Provide Ip-54 Protection . The Each Part Of The Fabricated Panel Will Be Strictly Subjected To Seven Tank Treatment . The Various Components , Assemblies And Sub Equipments Of The Panel Will Be As Per Standard Given In Relevant Is . The Bus Bar Of The Panel Will Be Shaped Out Of High Conductivity , Electrolytic Conductor And Shall Be Liberal Sized In Aluminum . The Control Wiring Of The Panel Will Be Done With Pvc Flexible Copper Wires Of 1 . 5 Mm Cross Section . Each Wire Will Be Terminating With A Ferule Crimped To The Wire , Size 1600Mmx1800x375mm . Having Following Components Of Approved Make . , Mccb 415V , Tp 3Phase High Breaking Capacity 50 Ka , 50Hz , 200 Amp With Spreader - Make L&T / Siemens , Mccb 415V , Tp 3Phase High Breaking Capacity 50 Ka , 50Hz , 100 Amp - Make L&T , Mcb Single Pole 63 Amp . Make L&T / Havells , Mcb Triple Pole 32 Amp . Make L&T / Havells , Mcb Triple Pole 63 Amp . Make L&T / Havells , Pvc Insulated Copper Flexible Cable 16 Sq Mm . Make: Havells / Finolex / Polycab . , Power Capacitors 415V Unit Of 10 Kvar Make: Epcos , Over Load Relay 30-50 . Make: L&T / Siemens , Over Load Relay 6-10 . Make: L&T / Siemens , Digital Amp . Meter Make Ae / L&T , Digital Volt Meter 0-500V -Make Ae / L&T , Motor Protection Relay Mm10 Make: L&T / Siemens , Power Contactor 220V 3Phase 70 Amp . Make L&T / Siemens , Power Contactor 220V 3Phase 50 Amp . Make L&T / Siemens , Power Contactor 220V 3Phase 25 Amp . Make L&T / Siemens , Star Delta Timer On Delay Make: L&T / Siemens , Indicating Lights Led Type Ryb & On / Off . Make : L&T / Havells / Sg , Current Transformer200 / 5 , 100 / 5 . Make: Ae / Advance , On Load Changeover Switch 200 Amp . Open Execution Type . Make L&T / Havells . , Fitting Of The Above Components In Panel Enclosure With Terminal Blocks , Channels , Ferrules , Thimble , Support Insulator On Bus Bar , Required Hard Wares Control Wiring In 1 . 5 Sq Mm Wire Complete In All Respect . , Earthling G . I . Earth Plate 600Mmx600mmx6mm Thick Including Accessories , And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2 . 7Metre Long Etc . Charcoal / Coke And Salt As Required . ( Dsr-2018 Page No . 26 , 5 . 4 ) , Testing & Commissioning Of Panel As Per Required Parameters With Relevant Is . Testing Of The Panel Prior To Switching On As Follow . Continuity And Earth Testing , Meggaring Of All Equipments For Phase To Phase , Neutral To Body , Neutral To Earth And Phase To Earth . Checking For All Tightness Of Nut And Bolts , Alignments Of Doors Etc . Interlocking Tests . All Function Tests , Testing On Load With Engineer In Charge