Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #21384342

Repair /Maintenance Of Solar Water Heating System At Vsn Nagpur

Issued by Statutory Bodies & Commissions/Committees · GE AF Nagpur, Maharashtra
Tender Value
6.13 Lakhs
Estimated cost
Bid Submission
04 Sep 2019
0 days left
EMD
12260
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
GE AF Nagpur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair /Maintenance Of Solar Water Heating System At Vsn Nagpur , material & labour for dismantling of existing damaged fpc panel from solar water heater & connected , testing commissioning and cleaning of service tank/storage tank etc . with replacing the following given in schedule no 02 items including necessary electrical/water connection including transportation up and down complete all as specified and as directed . note: the items will be measured & paid for seperately as supply only ( item no 2 . 00 ) , supply only new fpc panels size 2m x 1m , taking down damaged panel & supply new , fixing , testing & commissioning of toughen u v glass ( 1mtr x 2mtr ) and as per existing size of glass for collector complete all as specified and as directed . , taking down u/s hot water tank capacity 500 lpd & supply and install , testing and commissioning of solar hot water tank 500 lpd capacity flate plate collector based on indirect transfer of heat tank duly insulated , complete all as specified and as directed . , takiing down u/s steeel stand and material and labour for fabrication steel stand for holding the panels / storage tank as required complete all as specified and as directed . , taking down u/s & supply and laying 20 mm bores of tubes medium grade galvanised with all fittings and fixed complete laid in trenches/wall and ceilin or laid in floors complete all as specified and as directed . , taking down u/s & supply and laying 25 mm bores of tubes medium grade galvanised with all fittings and fixed complete laid in trenches/wall and ceilin or laid in floors complete all as specified and as directed . , taking down u/s pipe & supply and fix k-tech pipe pf 15 mm bore dia for hot water including all fittings complete all as specified and as directed . , m & l for descaling of collector using fernox ds-3 cleaner chemical or oem recommendation to clear the deposites of temporary hard ness inside of collector tubes/flate plate collectors including braizing of leaking joint as required at site complete all as specified and as directed . ( smq map area ) , m & l for descaling of collector using fernox ds-3 cleaner chemical or oem recommendation to clear the deposites of temporary hard ness inside of collector tubes/flate plate collectors including braizing of leaking joint as required at site complete all as specified and as directed . ( otm area ) , m & l for descaling of collector using fernox ds-3 cleaner chemical or oem recommendation to clear the deposites of temporary hard ness inside of collector tubes/flate plate collectors including braizing of leaking joint as required at site complete all as specified and as directed . ( map omq area ) , m & l for descaling of collector using fernox ds-3 cleaner chemical or oem recommendation to clear the deposites of temporary hard ness inside of collector tubes/flate plate collectors including braizing of leaking joint as required at site complete all as specified and as directed . ( 22 p&s ) ) , taking down u/s & supply fixing , testing & commissioning of insulation for hot/cold water pipe 20/25 mm bore pipe of insulation on pipe complete all as specified and as directed . , m & l for descaling of heat exchanger inside of hot water tank after repair , testing & tank capacity 500 ltr existing tank including replacement of coldwater/hot water pipe complete all as specified and as directed . , m & l for descaling of heat exchanger inside of hot water tank after repair , testing & tank capacity 200 ltr existing tank including replacement of coldwater/hot water pipe complete all as specified and as directed . , material and labour for gas welding of leaking joint in the flat panel collector complete all as specified and as directed . , taking down u/s supply and fix gun metal , globe or gate valves with iron wheel head , screwed both ends for iron pipe of 25 mm , including taking down complete all as specified and as directed . , taking down u/s supply and fix gun metal , globe or gate valves with iron wheel head , screwed both ends for iron pipe of 20 mm , including taking down complete all as specified and as directed . , taking down u/s supply and fix brass metal nrv isi mark of size 20 dia complete with nuts , bolts , rubber gaskets etc including , testing complete all as specified and as directed . , taking down u/s s & f rotational moulded polyethylene water storage tanks isi marked of capacity 1000 ltrs 3 layers ( cylinderical vertical with closed top ) hoisted and fixed in position including all accessories complete all as specified and as directed . , taking down u/s and supply and fix bib tap , cast copper alloy chromium coated , screwed down , screwed for iron pipe or for brass ferrule and fixed size 15 mm bore dia of pipe complete all as specified and as directed . make: - jaquar/ prayag , m & l for pcc 1:3:6 with 20 mm aggregate for making foundation for placing of rotational moulded polyethylene water storage tanks of capacity 500 ltrs complete all as specified and as directed . , taking out of defective evacuated tube from tube collector panel based on direct transforming heat of capacity 250 lpd and supply and install new evacuated tube in to the direct transfer heat solar panel complete all as specified and as directed . , taking down u/s supply and fix solar hot water hose pipe 1 ( 25 . 4 ) mm dia conforming to is ( 444 ) type 2 ( wp ) suitable for water pressure 12kg/cm2 complete all as specified and as directed . , comprehensive maintenance for reverse osmosis plant and control panel of capacity 250 lph for producing safe drinking water of make / aqua pvt ltd including replacement of defective spare parts , chemical wash using oem recommended chemical , back wash , cleaning of media vessel i . sand and carbon , cleaning of membrane and making the units functional as per requirement and emergency mainenance complete all as specified and as directed . note: - ( i ) spare parts will be measured and paid separately . ( ii ) the rate shall be included complete repair of control panel including replacement of all u/s spare parts if required . , supply only ro filter media ( sand ) ( sediment filter ) for 250 lph capacity , supply only ro carbon media ( carbon filter ) for 250 lph capacity , supply only carbon micron filter for 250 lph ro plant , supply only post carbon filter for 250 lph ro plant , supply only membrane suitable for 250 ltr ro plant , note: - treated water quality required to be tested . if the parameter are not within permissible limit , the work has to be carried out till the parameters are obtained without any extra cost . ( tds-< 50 ppm , ph-7 . 0+/-0 . 2 , turbidity-nil , colour - nil ) , dismantling of raw water feed pump pump set 0 . 5hp 1 phase from ro plant after isolating the electric & connections , suction and delivery pipes etc opening the pump set , motor rotor and stator etc for repair/overhauling including replacing the unserviceable parts with new items given vide item no given below and reassemblying the pumpset and reinstalling on foundation frame connecting , testing and commissioning complete all as specified and as directed . , supply only spare parts for pump set of capacity 0 . 5 hpvide item no . 31 . 00 as follows: - , supply only bearing , supply only key for main shaft , supply only check nut , supply only impeller , supply only water seal , supply and laying of cpvc pipes 25 mm dia outer sdr 11 & plain cpvc sdr 11 fittings in trenches/floor complete all as specified and as directed . , supply and laying of cpvc pipes 20 mm dia outer sdr 11 & plain cpvc sdr 11 fittings in trenches/floors complete all as specified and as directed . , supply and fix ball valves / gate valves 20mm dia outer pipe cpvc pipe complete all as specified and as directed . , dismantling & complet overhau

BOQ

Name of Work: REPAIR /MAINT OF SOLAR WATER HEATING SYSTEM AT VSN NAGPUR
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Material & Labour for Dismantling of Existing Damaged FPC Panel from solar water heater & connected, testing commissioning and cleaning of service tank/storage tank etc. with replacing the following given in schedule No 02 items including necessary electrical/water connection including transportation up and down complete all as specified and as directed.\nNote: The items will be measured & paid for seperately as supply only (Item No 2.00)2Job
22Supply only new FPC Panels size 2m x 1m2Each
33Taking down Damaged panel & Supply new, fixing, testing & commissioning of toughen U V glass (1Mtr x 2Mtr) and as per existing size of glass for collector complete all as specified and as directed.10Each
44Taking down U/S Hot water tank capacity 500 lpd & Supply and install , Testing and commissioning of solar Hot water tank 500 lpd capacity flate plate collector based on indirect transfer of heat tank duly insulated, complete all as specified and as directed.1Each
55Takiing down U/S steeel stand and Material and Labour for fabrication steel stand for holding the panels / storage tank as required complete all as specified and as directed.1Each Job
66Taking down U/s & Supply and laying 20 mm bores of tubes 'medium grade' galvanised with all fittings and fixed complete laid in trenches/wall and ceilin or laid in floors complete all as specified and as directed.60RM
77Taking down U/s & Supply and laying 25 mm bores of tubes 'medium grade' galvanised with all fittings and fixed complete laid in trenches/wall and ceilin or laid in floors complete all as specified and as directed.30RM
88Taking down U/S pipe & Supply and fix K-Tech pipe pf 15 mm bore dia for hot water including all fittings complete all as specified and as directed.30RM
99M & L for descaling of collector using Fernox DS-3 cleaner chemical or OEM recommendation to clear the deposites of temporary hard ness inside of collector tubes/Flate plate collectors including braizing of leaking joint as required at site complete all as specified and as directed. ( SMQ MAP area )45Each
1010M & L for descaling of collector using Fernox DS-3 cleaner chemical or OEM recommendation to clear the deposites of temporary hard ness inside of collector tubes/Flate plate collectors including braizing of leaking joint as required at site complete all as specified and as directed. (OTM Area)28Each
1111M & L for descaling of collector using Fernox DS-3 cleaner chemical or OEM recommendation to clear the deposites of temporary hard ness inside of collector tubes/Flate plate collectors including braizing of leaking joint as required at site complete all as specified and as directed. (MAP OMQ area)16Each
1212M & L for descaling of collector using Fernox DS-3 cleaner chemical or OEM recommendation to clear the deposites of temporary hard ness inside of collector tubes/Flate plate collectors including braizing of leaking joint as required at site complete all as specified and as directed. (22 P&S))8Each
1313Taking down U/S & Supply fixing , testing & commissioning of insulation for hot/cold water pipe 20/25 mm bore pipe of insulation on pipe complete all as specified and as directed.250RM
1414M & L for descaling of heat exchanger inside of hot water tank after repair , testing & tank capacity 500 ltr existing tank including replacement of coldwater/hot water pipe complete all as specified and as directed.15Each Job
1515M & L for descaling of heat exchanger inside of hot water tank after repair, testing & tank capacity 200 ltr existing tank including replacement of coldwater/hot water pipe complete all as specified and as directed.3Each Job
1616Material and labour for gas welding of leaking joint in the flat panel collector complete all as specified and as directed.20Each Job
1717Taking down U/S Supply and fix gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe of 25 mm, including taking down complete all as specified and as directed.6Each
1818Taking down U/S Supply and fix gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe of 20 mm, including taking down complete all as specified and as directed.6Each
1919Taking down U/S Supply and fix brass metal NRV ISI mark of size 20 dia complete with nuts, bolts, rubber gaskets etc including, testing complete all as specified and as directed.5Each
2020Taking down U/S S & F rotational moulded polyethylene water storage tanks ISI marked of capacity 1000 Ltrs 3 layers (cylinderical vertical with closed top) hoisted and fixed in position including all accessories complete all as specified and as directed.3Each
2121Taking down U/s and Supply and fix bib tap, cast copper alloy chromium coated, screwed down, screwed for iron pipe or for brass ferrule and fixed size 15 mm bore dia of pipe complete all as specified and as directed. \nMake: - Jaquar/ Prayag8Each
2222M & L for PCC 1:3:6 with 20 mm aggregate for making foundation for placing of rotational moulded polyethylene water storage tanks of capacity 500 Ltrs complete all as specified and as directed.2Cum
2323Taking out of defective evacuated tube from tube collector panel based on direct transforming heat of capacity 250 lpd and supply and install new evacuated tube in to the direct transfer heat solar panel complete all as specified and as directed.10Each
2424Taking down U/S Supply and fix solar hot water hose pipe 1\" (25.4) mm dia conforming to IS (444) type 2 (WP) suitable for water pressure 12kg/cm2 complete all as specified and as directed.35RM
2525Comprehensive Maintenance for reverse osmosis plant and control panel of capacity 250 LPH for producing safe drinking water of make / aqua pvt ltd including replacement of defective spare parts, Chemical wash using oem recommended chemical , back wash, cleaning of media vessel i. sand and carbon, cleaning of membrane and making the units functional as per requirement and emergency mainenance complete all as specified and as directed.\nNote: - (i) Spare parts will be measured and paid separately.\n(ii) The rate shall be included complete repair of control panel including replacement of all u/s spare parts if required.1Each Job
2626Supply only RO filter media (sand) (sediment filter) for 250 lph capacity1Job
2727Supply only RO carbon media (carbon filter) for 250 lph capacity1Job
2828Supply only carbon Micron filter for 250 lph ro plant2Each
2929Supply Only post carbon filter for 250 lph ro plant1Each
3030Supply only Membrane suitable for 250 LTR RO plant1Each
3130.01Note: - Treated water quality required to be tested. If the parameter are not within permissible limit, the work has to be carried out till the parameters are obtained without any extra cost. (TDS-< 50 ppm, PH-7.0+/-0.2, Turbidity-Nil, Colour - NIL)\n
3231Dismantling of raw water feed pump pump set 0.5HP 1 phase from ro plant after isolating the electric & connections, suction and delivery pipes etc opening the pump set, motor rotor and stator etc for repair/overhauling including replacing the unserviceable parts with new items given vide item No given below and reassemblying the pumpset and reinstalling on foundation frame connecting, testing and commissioning complete all as specified and as directed.1Each
3337Supply only spare parts for pump set of capacity 0.5 HPvide item No. 31.00 as follows: -
3437.01Supply only bearing1Each
3537.02Supply only key for main shaft1Each
3637.03Supply only check nut1Each
3737.04Supply only impeller1Each
3837.05Supply only water seal1Each
3938Supply and laying of CPVC pipes 25 MM dia outer SDR 11 & plain CPVC SDR 11 fittings in trenches/floor complete all as specified and as directed.20RM
4039Supply and laying of CPVC pipes 20 MM dia outer SDR 11 & plain CPVC SDR 11 fittings in trenches/floors complete all as specified and as directed.15RM
4140Supply and fix ball valves / gate valves 20mm dia outer pipe CPVC pipe complete all as specified and as directed.2Each
4241Dismantling & complet overhauling of pressure multistage pump 1.5 HP and from RO plant after isolating the electric and earth lead connections, suction and delivery pipes etc opening the pump set, motor rotor and stator etc for repair/ overhauling maintiance of pressure pump for 100 LHP capacity of ro plant and supply and replace unserviceable spare parts as required to functionla of pump with new complete all as specified and as directed.1Each
4342Supply only spare parts for pump set of capacity 1.5 HP pressure vide item No. 41.00 as follows:-
4442.01Supply only bearing1Each
4542.02Supply only key for main shaft1Each
4642.03Supply only check nut1Each
4742.04Supply only multistaged impeller2Each
4842.05Supply only water seal1Each
4942.06Bush1Each
5043Material & Labour for Dismantling of Existing Damaged FPC Panel from solar water heater & refixing same after repaired and connected, testing commissioning and repairing of flanges, nut bolts and fixing support made otu of irn angles as pe existing size of panel and new refixing outside metalic frame around tough glass including necessary electrical/water connection including transportation up and down complete all as specified and as directed.4Job

AI Tender Summary

OUR REF NO 21384342
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 6.13 Lakhs
LAST DATE 04-09-2019
Authority
Authority Name Military Engineer Services
Work Description Repair /Maintenance Of Solar Water Heating System At Vsn Nagpur , material & labour for dismantling of existing damaged fpc panel from solar water heater & connected , testing commissioning and cleaning of service tank/storage tank etc . with replacing the following given in schedule no 02 items including necessary electrical/water connection including transportation up and down complete all as specified and as directed . note: the items will be measured & paid for seperately as supply only ( item no 2 . 00 ) , supply only new fpc panels size 2m x 1m , taking down damaged panel & supply new , fixing , testing & commissioning of toughen u v glass ( 1mtr x 2mtr ) and as per existing size of glass for collector complete all as specified and as directed . , taking down u/s hot water tank capacity 500 lpd & supply and install , testing and commissioning of solar hot water tank 500 lpd capacity flate plate collector based on indirect transfer of heat tank duly insulated , complete all as specified and as directed . , takiing down u/s steeel stand and material and labour for fabrication steel stand for holding the panels / storage tank as required complete all as specified and as directed . , taking down u/s & supply and laying 20 mm bores of tubes medium grade galvanised with all fittings and fixed complete laid in trenches/wall and ceilin or laid in floors complete all as specified and as directed . , taking down u/s & supply and laying 25 mm bores of tubes medium grade galvanised with all fittings and fixed complete laid in trenches/wall and ceilin or laid in floors complete all as specified and as directed . , taking down u/s pipe & supply and fix k-tech pipe pf 15 mm bore dia for hot water including all fittings complete all as specified and as directed . , m & l for descaling of collector using fernox ds-3 cleaner chemical or oem recommendation to clear the deposites of temporary hard ness inside of collector tubes/flate plate collectors including braizing of leaking joint as required at site complete all as specified and as directed . ( smq map area ) , m & l for descaling of collector using fernox ds-3 cleaner chemical or oem recommendation to clear the deposites of temporary hard ness inside of collector tubes/flate plate collectors including braizing of leaking joint as required at site complete all as specified and as directed . ( otm area ) , m & l for descaling of collector using fernox ds-3 cleaner chemical or oem recommendation to clear the deposites of temporary hard ness inside of collector tubes/flate plate collectors including braizing of leaking joint as required at site complete all as specified and as directed . ( map omq area ) , m & l for descaling of collector using fernox ds-3 cleaner chemical or oem recommendation to clear the deposites of temporary hard ness inside of collector tubes/flate plate collectors including braizing of leaking joint as required at site complete all as specified and as directed . ( 22 p&s ) ) , taking down u/s & supply fixing , testing & commissioning of insulation for hot/cold water pipe 20/25 mm bore pipe of insulation on pipe complete all as specified and as directed . , m & l for descaling of heat exchanger inside of hot water tank after repair , testing & tank capacity 500 ltr existing tank including replacement of coldwater/hot water pipe complete all as specified and as directed . , m & l for descaling of heat exchanger inside of hot water tank after repair , testing & tank capacity 200 ltr existing tank including replacement of coldwater/hot water pipe complete all as specified and as directed . , material and labour for gas welding of leaking joint in the flat panel collector complete all as specified and as directed . , taking down u/s supply and fix gun metal , globe or gate valves with iron wheel head , screwed both ends for iron pipe of 25 mm , including taking down complete all as specified and as directed . , taking down u/s supply and fix gun metal , globe or gate valves with iron wheel head , screwed both ends for iron pipe of 20 mm , including taking down complete all as specified and as directed . , taking down u/s supply and fix brass metal nrv isi mark of size 20 dia complete with nuts , bolts , rubber gaskets etc including , testing complete all as specified and as directed . , taking down u/s s & f rotational moulded polyethylene water storage tanks isi marked of capacity 1000 ltrs 3 layers ( cylinderical vertical with closed top ) hoisted and fixed in position including all accessories complete all as specified and as directed . , taking down u/s and supply and fix bib tap , cast copper alloy chromium coated , screwed down , screwed for iron pipe or for brass ferrule and fixed size 15 mm bore dia of pipe complete all as specified and as directed . make: - jaquar/ prayag , m & l for pcc 1:3:6 with 20 mm aggregate for making foundation for placing of rotational moulded polyethylene water storage tanks of capacity 500 ltrs complete all as specified and as directed . , taking out of defective evacuated tube from tube collector panel based on direct transforming heat of capacity 250 lpd and supply and install new evacuated tube in to the direct transfer heat solar panel complete all as specified and as directed . , taking down u/s supply and fix solar hot water hose pipe 1 ( 25 . 4 ) mm dia conforming to is ( 444 ) type 2 ( wp ) suitable for water pressure 12kg/cm2 complete all as specified and as directed . , comprehensive maintenance for reverse osmosis plant and control panel of capacity 250 lph for producing safe drinking water of make / aqua pvt ltd including replacement of defective spare parts , chemical wash using oem recommended chemical , back wash , cleaning of media vessel i . sand and carbon , cleaning of membrane and making the units functional as per requirement and emergency mainenance complete all as specified and as directed . note: - ( i ) spare parts will be measured and paid separately . ( ii ) the rate shall be included complete repair of control panel including replacement of all u/s spare parts if required . , supply only ro filter media ( sand ) ( sediment filter ) for 250 lph capacity , supply only ro carbon media ( carbon filter ) for 250 lph capacity , supply only carbon micron filter for 250 lph ro plant , supply only post carbon filter for 250 lph ro plant , supply only membrane suitable for 250 ltr ro plant , note: - treated water quality required to be tested . if the parameter are not within permissible limit , the work has to be carried out till the parameters are obtained without any extra cost . ( tds-< 50 ppm , ph-7 . 0+/-0 . 2 , turbidity-nil , colour - nil ) , dismantling of raw water feed pump pump set 0 . 5hp 1 phase from ro plant after isolating the electric & connections , suction and delivery pipes etc opening the pump set , motor rotor and stator etc for repair/overhauling including replacing the unserviceable parts with new items given vide item no given below and reassemblying the pumpset and reinstalling on foundation frame connecting , testing and commissioning complete all as specified and as directed . , supply only spare parts for pump set of capacity 0 . 5 hpvide item no . 31 . 00 as follows: - , supply only bearing , supply only key for main shaft , supply only check nut , supply only impeller , supply only water seal , supply and laying of cpvc pipes 25 mm dia outer sdr 11 & plain cpvc sdr 11 fittings in trenches/floor complete all as specified and as directed . , supply and laying of cpvc pipes 20 mm dia outer sdr 11 & plain cpvc sdr 11 fittings in trenches/floors complete all as specified and as directed . , supply and fix ball valves / gate valves 20mm dia outer pipe cpvc pipe complete all as specified and as directed . , dismantling & complet overhau
Basic Detail
Tender No GE/NAG/19-20/8302/33
Bidding Type Tender
Location
City GE AF Nagpur
State Maharashtra
Key Dates
Publish Date 13 Aug 2019
Submission Date 04 Sep 2019
Open Date 05 Sep 2019
Finance
Tender Value 6.13 Lakhs
Tender Fee 500
EMD 12260
Exemption Not Available
Document List
Tendernotice_1.pdf
SOC8302.pdf
TD8302.pdf
98233055-4E30-4F13-B594-56073D2F58C2.html
BOQ_307630.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 04, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 05, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

SOC8302.pdf

pdf

TD8302.pdf

html

98233055-4E30-4F13-B594-56073D2F58C2.html

xls

BOQ_307630.xls

TenderDetail