Repair/Replacement/Maintenance Of Ceiling Fan , Exhaust Fan , Pedestal/Wall Fan , Internal Electrification And Certain E/M Works At Harni Airfield At Af Stn Baroda , Material And Labour For Taking Down And Transporting Of Celling Fan 1200 /1400 Mm From Any Location Inside Airforce Harni Air Camp & Harni Air Field Stn Mes E/M Store Yard For Stripping Of Fan Washing Thoroughly Of Bearing/Bush By Petrol , Washing/Cleaning Fan Blade , Body Thoroughly , Greasing And Oiling Complete And Replacement Of Wornout/Defective Unserviceable Parts ( Wherever Necessary ) Reassembling The Same After Repair/Replacement Of Defective And Unserviceable Parts Including Provision Of Twisted Twin Core Flexible Wire Of Size 23/0 . 0076 ( Isi Marked ) Not Less Than 0 . 5 Sqmm And Testing The Fan On Full Load To Entire Satisfaction Of Engr-In-Charge And Depositing Back To Mes E/M Store Yard Complete All As Specified And Directed . , All As Item No 1 Above But For Exhaust Fan Of Size 300Mm . , All As Item No 1 Above But For Wall Mounted /Pedestal Fan Of Size 450Mm/400Mm . , Note For Above Item No 1 . 00 To 3 . 00 :- ( I ) Replacement Of Parts/ Rewinding Shall Be Measured And Paid Seperately . ( Ii ) Quoted Rate Is Deemed To Be Inclusive Of Transporting Fan From Any Location In Air Force Harni Camp And Harni Air Field To Mes Store & Taking Down Unserviceable/ Defective Parts ) . , Hanging Carefully Ceiling Fan In Hook And Connecting Electrically Repaired Ceiling Fan Of Any Make Any Type Including Transporting From Mes Store Yard To Any Location In Side And Testing The Fan To The Entire Satisfaction Of Engineer-In-Charge Complete All As Specified And Directed . . , Material And Labour For Rewinding Of Ceiling Fan Of Any Make Any Type Of Size 1200/1400Mm With Supper Enamelled Copper Conductor Wire Of Suitable Size/Gauge As Per Exsting Including All Insulating Materials , Varnishing And Heating And Testing On Load Complete All As Specified And Directed . , Material And Labour For Rewinding Exhaust Fan Of Any Make Of Size 300Mm With Super Enamelled Copper Wire Of Suitable Size/Gauge Including All Insulation Materials , Varnishing And Heating And Testing On Load Complete All As Specified And Directed . , Material And Labour For Rewinding Of Pedestal Fan/Wall Mounted Fan Of Size 450/400Mm And Any Make With Super Enamelled Copper Wire Of Suitable Size/Gauge Including All Insulation Materials , Varnishing And Heating And Testing On Load Complete All As Specified And Directed . , Material And Labour In Replacement Of Unserviceable Ball Bearing Of Any Size Suitable For Any Type/Make Of Ceiling Fan Including Testing As Approved By Engr-In-Charge Complete All As Specified And Directed . , Material And Labour In Replacement Of Unserviceable Gun Metal Bush Of Size Suitable For Any Type/Make Of Ceiling Fan Including Fixing Complete All As Specified And Directed . , M&L In Repair Of Gun Metal Bush Suitable For Table/ Wall Mounted Fan/ Pedestal Fan Of Any Size Complete All As Specified And Directed . , Material And Labour In Replacement Of Fan Blades ( Set Of Three ) Of Existing Make/Type Of Ceiling Fan Of Size 1200/1400Mm Sweep Complete All As Directed By Engr-In-Charge . , Material And Labour In Replacement Of Unserviceable Capaciator 240 Volts Ac 2 . 5 Mfd Suitable For Ceiling Fan Including Condensor Spacer And Soldering Of Condenser Wire To Fan Wire And Fixing Complete All As Specified And Directed . , Material And Labour In Replacement Of Capaciator 240 Volts 4 Mfd Suitable For Exhaust Fan/Pedestal Fan Including Testing Complete All As Specified And Directed . , Material And Labour For Replacement Of Unserviceable Rubber Seals , Including Hanging Bolts , Nuts , Washer Split Pins Of Appropriate Size As Required And Fixing Complete All As Specified And Directed . , Material And Labour For Spray Painting Of Ceiling Fan Of Size 1200Mm/1400Mm , Fan Blades , Down Rod , Canopy Etc With A Coat Synthetic Enamel Paint Of Approved Colour And Quality Including Preparation Of Old Painted Surfaces , Cleaning Etc Complete All As Specified And Directed . , All As Item No 15 . 00 Above But For Exhaust Fan Of Size 300Mm Any Size Complete All As Specified And Directed . . , S&F In Repair Of Plastic Canopy Upper And Lower Size Any Make Of Ceiling Fan Fixed With Suitable Size Of Screws All As Directed . , Checking And Attending Complaint By Means Of Repairing/Rectifying The Electric Defects/Faults Related To Elctrical Equipment , Devices , Accessories And Fixtures Maintained By Mes . Tightening The Loose Connections , Insulating The Naked Wire If Any And Ensuring Continuity Of Electric Supply To Harni Camp By Providing One Electrician 0900 Hrs To 1730 Hrs Including Sunday And Holidays . ( Including Lunch Break From 1300Hrs To 1330Hrs ) . Note : 1 . This Item Covers Only Cost Of Labour For Attending Complaint And Taking Down Of Old Material . 2 . Item Replaced Shall Be Measured And Paid Under Respective Item Of This Schedule . 3 . Electrician Should Not Absent On Duty , If Found Absent A Recovery Of Rs 500/- Per Day Will Be Charged Complete All As Specified And Directed . , Taking Down Carefully Copper / Aluminium Point Wiring Including ( Light , Fan , Socket Or Power Complete Fittings , Such As Switches , Ceiling Roses , Pendant Holders , Batten Holders , Shades Conical Fan Regulators , Light Or Power Sockets Etc ) Removing Materials From Site And Making Good Disturbed Surfaces Of Walls Roofs Etc Complete All As Specified And Directed . , Taking Down Carefully Unsv Main Switch And Dbs Including Mcbs Of Of Any Size , Type And Capacity And Depositing At Site Complete All As Specified And Directed . , M&L For Point Wiring Complete With 1 . 5 Sqmm Single Core Pvc Insulated And Pvc Unsheathed ( Frls ) Multistranded Copper Conductor Cable 1100 Volt Grade Enclosed In And Including Pvc Casing And Capping With Accessories Fixed On Surface On Walls/Ceiling By Means Of Pvc Sleeves Dash Fastners And Cadmium Plated Screws All As Per Isi Including Sunk Type Boxes For Mounting Fitting Like Switches , Socketes Fan Regulators With 3 Mm Thick Phenolic Laminated Sheet Top Covers Concealed In Walls Etc Including 1 . 5 Sqmm Single Core Multi Stranded Copper Conductor Pvc Insulated And Unsheathed Cable As Earth Continuity Conductor To Common Earth Dolly . , One Light/Fan/Bell Point Controlled By One One/Way Switch . , One 3 Pin 5 Amps Socket Outlet On Same Board With Other Switch . , One 3 Pin 5 Amps Socket Outlet On Independent Board . , All As Above Item No 21 . 00 Above But Wiring With 2 . 5 Sqmm Multistranded Copper Conductor Unsheathed And 1 . 5 Sqmm Copper Conductor Unsheathed Cable As Earth Continuity Conductor For One 3 Pin 15 Amps Socket Outlet Point On Independent Board Complete All As Specified And Directed . , M&L For Drawing In Existing Conduit System Of Wiring Concealed Point Wiring Complete With Multistranded Copper Conductor 1 . 5 Sqmm Size Pvc Insulated Unsheathed Cable 1100 Volt Grade , Conforming Is 694 & Color Code Drawing In Existing Conduit System Of Wiring , Complete , Sunk In Pressed Existing Steel Terminal Boxes Of Available Size With Providing Top Cover 3 Mm Thick Plastic Laminated Sheet Fixed With Brass Screw And Washer With All Accessories Including Single Core Solid Conductor Copper 1 . 5 Sqmm Size Solid Pvc Insulated Unsheathed Cable As Earth Wire To Common Earth And Connected To Earth Dolly Drawn In Same Conduit Complete All As Specified . , One Light/Fan/Bell Point Controlled By One Way Switch . , One 3 Pin 5 Amps Socket Outlet On Same Board With O