Military Engineer Services-MES has published Repair/Replacement/Maintenance Of Ceiling Fan , Exhaust Fan , Pedestal/Wall Fan , Internal Electrification And Certain E/M Works At Harni Airfield At Af Stn Baroda. Submission Date for this Tender is 29-08-2019. Bearings Tenders in GE AF BARODA Gujarat. Bidders can get complete Tender details and download the document.
Name of Work : REPAIR/REPLACEMENT/MAINTENANCE OF CEILING FAN, EXHAUST FAN, PEDESTAL/WALL FAN, INTERNAL ELECTRIFICATION AND CERTAIN E/M WORKS AT HARNI AIRFIELD AT AF STN BARODA | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Material and labour for taking down and transporting of celling fan 1200 /1400 mm from any location inside Airforce Harni Air Camp & Harni Air fIeld stn MES E/M store yard for stripping of fan washing thoroughly of bearing/bush by petrol, washing/cleaning fan blade, body thoroughly, greasing and oiling complete and replacement of wornout/defective unserviceable parts (wherever necessary) reassembling the same after repair/replacement of defective and unserviceable parts including provision of twisted twin core flexible wire of size 23/0.0076 (ISI marked) not less than 0.5 sqmm and testing the fan on full load to entire satisfaction of Engr-in-Charge and depositing back to MES E/M store yard complete all as specified and directed. | 110 | Each | |
2 | 2 | All as item no 1 above but for exhaust fan of size 300mm. | 15 | Each | |
3 | 3 | All as item no 1 above but for wall mounted /pedestal fan of size 450mm/400mm. | 15 | Each | |
4 | 3.01 | Note for above Item No 1.00 to 3.00 :- \n(i) Replacement of parts/ rewinding shall be measured and paid seperately. (ii) Quoted rate is deemed to be inclusive of transporting fan from any location in air force Harni camp and Harni air field to MES store & taking down unserviceable/ defective parts). | |||
5 | 4 | Hanging carefully ceiling fan in hook and connecting electrically repaired ceiling fan of any make any type including transporting from MES Store Yard to any location in side and testing the fan to the entire satisfaction of Engineer-in-Charge complete all as specified and directed.. | 110 | Each | |
6 | 5 | Material and labour for rewinding of ceiling fan of any make any type of size 1200/1400mm with supper enamelled copper conductor wire of suitable size/gauge as per exsting including all insulating materials, varnishing and heating and testing on load complete all as specified and directed. | 110 | Each | |
7 | 6 | Material and labour for rewinding exhaust fan of any make of size 300mm with super enamelled copper wire of suitable size/gauge including all insulation materials, varnishing and heating and testing on load complete all as specified and directed. | 15 | Each | |
8 | 7 | Material and labour for rewinding of pedestal fan/wall mounted fan of size 450/400mm and any make with super enamelled copper wire of suitable size/gauge including all insulation materials, varnishing and heating and testing on load complete all as specified and directed. | 15 | Each | |
9 | 8 | Material and labour in replacement of unserviceable ball bearing of any size suitable for any type/make of ceiling fan including testing as approved by Engr-in-Charge complete all as specified and directed. | 50 | Each | |
10 | 9 | Material and labour in replacement of unserviceable gun metal bush of size suitable for any type/make of ceiling fan including fixing complete all as specified and directed. | 60 | Each | |
11 | 10 | M&L in repair of gun metal bush suitable for table/ wall mounted fan/ pedestal fan of any size complete all as specified and directed. | 25 | Each | |
12 | 11 | Material and labour in replacement of fan blades (set of three) of existing make/type of ceiling fan of size 1200/1400mm sweep complete all as directed by Engr-in-Charge. | 50 | Each Set | |
13 | 12 | Material and labour in replacement of unserviceable capaciator 240 volts AC 2.5 MFD suitable for ceiling fan including condensor spacer and soldering of condenser wire to fan wire and fixing complete all as specified and directed. | 150 | Each | |
14 | 13 | Material and labour in replacement of capaciator 240 Volts 4 MFD suitable for exhaust fan/Pedestal Fan including testing complete all as specified and directed. | 30 | Each | |
15 | 14 | Material and labour for replacement of unserviceable rubber seals, including hanging bolts, nuts, washer split pins of appropriate size as required and fixing complete all as specified and directed. | 110 | Each | |
16 | 15 | Material and labour for spray painting of ceiling fan of size 1200mm/1400mm, fan blades, down rod, canopy etc with a coat synthetic enamel paint of approved colour and quality including preparation of old painted surfaces, cleaning etc complete all as specified and directed. | 110 | Each | |
17 | 16 | All as item no 15.00 above but for exhaust fan of size 300mm any size complete all as specified and directed.. | 15 | Each | |
18 | 17 | S&F in repair of plastic canopy upper and lower size any make of ceiling fan fixed with suitable size of screws all as directed. | 110 | Each | |
19 | 18 | Checking and attending complaint by means of repairing/rectifying the electric defects/faults related to elctrical equipment ,devices,accessories and fixtures maintained by MES .Tightening the loose connections ,insulating the naked wire if any and ensuring continuity of electric supply to Harni Camp by providing one electrician 0900 hrs to 1730 hrs including Sunday and holidays. (Including lunch break from 1300hrs to 1330hrs ). Note : 1.This item covers only cost of labour for attending complaint and taking down of old material. 2. Item replaced shall be measured and paid under respective item of this schedule. 3. Electrician should not absent on duty, if found absent a recovery of Rs 500/- per day will be charged complete all as specified and directed. | 600 | Each Complaint | |
20 | 19 | Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and directed. | 225 | Each Point | |
21 | 20 | Taking down carefully UNSV main switch and DB's including MCBs of of any size, type and capacity and depositing at site complete all as specified and directed. | 31 | Each | |
22 | 21 | M&L for Point wiring complete with 1.5 sqmm single core PVC insulated and PVC unsheathed (FRLS) multistranded copper conductor cable 1100 volt grade enclosed in and including PVC casing and capping with accessories fixed on surface on walls/ceiling by means of PVC sleeves Dash fastners and cadmium plated screws all as per ISI including sunk type boxes for mounting fitting like switches, socketes fan regulators with 3 mm thick phenolic Laminated sheet top covers concealed in walls etc including 1.5 Sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth dolly. | |||
23 | 21.01 | One light/fan/bell point controlled by one one/way switch. | 50 | Each Point | |
24 | 21.02 | One 3 pin 5 Amps socket outlet on same board with other switch. | 10 | Each Point | |
25 | 21.03 | One 3 pin 5 Amps socket outlet on independent board. | 30 | Each Point | |
26 | 22 | All as above item No 21.00 above but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 1.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed. | 30 | Each Point | |
27 | 23 | M&L for drawing in existing conduit system of wiring concealed point wiring complete with multistranded copper conductor 1.5 Sqmm size PVC insulated unsheathed cable 1100 volt grade, conforming IS 694 & color code drawing in existing conduit system of wiring, complete, sunk in pressed existing steel terminal boxes of available size with providing top cover 3 mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including single core solid conductor copper 1.5 sqmm size solid PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit complete all as specified. | |||
28 | 23.01 | One light/fan/bell point controlled by one way switch. | 40 | Each Point | |
29 | 23.02 | One 3 pin 5 Amps socket outlet on same board with other switch. | 10 | Each Point | |
30 | 23.03 | One 3 pin 5 Amps socket outlet on independent board. | 20 | Each Point | |
31 | 24 | All as above item no 23.00 but using 2.5 Sqmm PVC insulated, unsheathed copper cable for one 3 pin socket outlet 15 Amps on independent board. | 20 | Each Point | |
32 | 25 | M&L for sub main wiring using two single core 6.0 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/ PVC Conduit accessories like bends, tee, etc. Dismantling and fix on wall and ceiling and connecting to earth dolly and including 4.0 Sqmm earth wire, PVC insulated & unsheathed all as directed.\nNote :- Two runs of 6 Sqmm and one run of 4Sqmm alongwith PVC Conduit shall be measured and paid in one length. | 120 | RM | |
33 | 26 | M&L for sub main wiring using two single core 4.0 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/ PVC Conduit or in existing concealed conduit accessories like bends, tee, etc. Dismantling and fix on wall and ceiling and connecting to earth dolly and including 2.5Sqmm earth wire, PVC insulated & unsheathed complete all as specified and directed.Note :- Two runs of 4.0 Sqmm and one run of 2.5Sqmm alongwith PVC Conduit shall be measured and paid in one length. | 210 | RM | |
34 | 27 | Supply only tube rod 28 watt complete all as specified and directed. | 50 | Each | |
35 | 28 | Supply only tube rod 36/40 watt complete all as specified and directed. | 300 | Each | |
36 | 29 | Supply only CFL pin type 20 Watt complete all as specified and directed. | 50 | Each | |
37 | 30 | Supply only switch piano flush type single pole one way 5 Amp 240 Volts complete all as specified and directed. | 200 | Each | |
38 | 31 | S&F in repairs switch socket combination 2 in 1, 3 pin, 5 Amps flush type 240 Volt complete all as specified and directed. | 120 | Each | |
39 | 32 | S&F in repairs switch socket combination 3 pin 5 and 15 Amp 2 in one flush type complete all as specified and directed. | 100 | Each | |
40 | 33 | S&F in repairs ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked complete all as specified and directed.. | 40 | Each | |
41 | 34 | Supply only stepped type electronic fan regulator flush type (ISI marked) complete all as specified and as directed. | 100 | Each | |
42 | 35 | S&F in repair of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN DB) with metal door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB/TPN and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box complete all as specified and directed.\nNOTE :-\n(a) MCBs shall be measured and paid separately.\n(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. | 5 | Each | |
43 | 36 | S&F in repair of factory made epoxy polyester powder coated distribution board SP & N 8 way with metal door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DP MCB as incommer and 6 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box complete all as specified and directed.\nNOTE :-\n(a) MCBs shall be measured and paid separately.\n(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. | 10 | Each | |
44 | 37 | S&F in repair of factory made epoxy polyester powder coated distribution board SP & N 12 way with metal door (IP-43 protection) IK-09 fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DP MCB as incommer and 6 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box complete all as specified and directed.\nNOTE :-\n(a) MCBs shall be measured and paid separately.\n(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. | 8 | Each | |
45 | 38 | S&F in repair of factory made epoxy polyester powder coated distribution board SP & N 4 way with metal door (IP-43 protection) IK-09 fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DP MCB as incommer and 6 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box complete all as specified and directed.\nNOTE :-\n(a) MCBs shall be measured and paid separately.\n(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. | 8 | Each | |
46 | 39 | NOTE :- | 15 | Each | |
47 | 40 | (a) MCBs shall be measured and paid separately. | 200 | Each | |
48 | 41 | (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. | 40 | Each | |
49 | 42 | Supply only Isolator three pole 40 Amp 415 Volts complete all as specified directed. | 6 | Each | |
50 | 43 | Supply only Isolator four pole 63 Amp 415 Volts complete all as specified directed. | 10 | Each | |
51 | 44 | Supply only Isolator four pole 100 Amp 415 Volts complete all as specified directed. | 10 | Each | |
52 | 45 | Supply only 23/0.0076 flexible cable 3.0 core for maintenance of tube light and fans complete all as specified and directed. | 100 | RM | |
53 | 46 | Supply only Instant flicker free start electronic ballast of Robust design suitable for FTL 36/40 watt 240 V 50/60Hz with high power factor (>0.90) and energy saving of more than 25 % including connection complete all as specified and directed. | 200 | Each | |
54 | 47 | Supply only electronic ballast suitable for tube light of 28 Watt complete all as specified and directed.\n | 40 | Each | |
55 | 48 | Supply only LED bulb of 12 watt complete all as specified and directed.\n | 100 | Each | |
56 | 49 | Supply only electronic ballast suitbable for ceiling mounted light of 3X36 watt complete all as specified and directed. | 40 | Each | |
57 | 50 | Supply only lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. | 30 | Each | |
58 | 51 | Supply only LED tube light 18 Watt which offers high lumen output with excellent energy saving and maintenance free operation is an ideal sulution for replacing existing T8 and T 12 fluorescent lamp where it needs higher illumination complete all as specified and directed. | 170 | Each | |
59 | 52 | Supply only Recessed mounted back lit LED 36 WATT tile with highly translucent wide window opal diffuser and suitable for 600 x 600 mm modular ceilings complete all as specified and directed. | 15 | Each | |
60 | 53 | Supply only modular switch 1 way 6 A , 1Modular | 120 | Each | |
61 | 54 | Supply only modular switch 1 way 16 A ,1 modular | 40 | Each | |
62 | 55 | Supply only modular Socket 6 A - 2/3 pin combined 2 module | 40 | Each | |
63 | 56 | Supply only modular Socket 16 A - 2/3 pin combined 2 module | 40 | Each | |
64 | 57 | Supply only modular fan regulator 120 W -2 module | 30 | Each | |
65 | 58 | Material and labour for flame proof point wiring complete with two runs of 2.5 sqmm single core multistandard copper conductor fire resistant low smoke (FRLS) PVC insulated and unsheathed cable 1100 Volt grade conforming to IS - 694 draw through and including ERW Steel conduit 25 mm dia (external) flame proof heavy duty grade (IS marked) including necessary all accessories /fixtures concealed in wall ceiling including suken type pressed steel shade 3 mm thick including providing continous earth wire with one single run of 1.5 sqmm single core multistranded copper FRLS PVC insulated unsheathed cable 1100 volts grade conforming to IS -694 including taking down UNSV point wiring complete all as specified and directed for following | |||
66 | 58.01 | One light/fan point controlled by one one way switch. | 10 | Each Point | |
67 | 58.02 | One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size. | 5 | Each Point | |
68 | 59 | Supply and fixing in repair of wall mountain fan 400 mm sweep complete all as specified and directed. | 5 | Each | |
69 | 60 | Supply and fixing in repair exaust fan iron body totally enclosed corrosion resistant light weight aluminium pressure die cast including heavy duty motor dynamically balanced blade for vibration free rotation anti corrosive treatment and attractive metalic finish available in sweep 300 mm sweep including cutting of hole of suitable size complete all as specified and directed. | 10 | Each | |
70 | 61 | Supply only flameproof type FLP-WP fluorescent tube light fitting 1x36W made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. | 10 | Each | |
71 | 62 | S&Fix in repair of Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed. | 6 | Each | |
72 | 63 | S&F in repair of flame proof switch socket outlet combination 16 A 240/500 V single phase 2P/3P +earth complete all as specified and directed . | 5 | Each | |
73 | 64 | Supply and provide Sodium Hypo Chlorite 65% -70% chlorine content Calcium based granular desinfectant for water treatment plants much more stable than chlorine gas & stronger than bleaching powder and sodium hypochlorite packed in 45 kg drum complete as directed by Engr-in- Charge. | 360 | KG | |
74 | 65 | Supply and fix in repairs aluminium strip 25mm x 3.15 mm complete with saddles and fixing screws for fitting the strip complete all as specified and directed. | 90 | RM | |
75 | 66 | Supply and fix in repairs copper strip 20mm x 3.15 mm complete with saddles and fixing screws for fitting the strip complete all as specified and directed. | 60 | RM | |
76 | 67 | Supply and fix in repairs test point terminal block made of GI Sheet box of size 90x90x90mm made of 1.6mm plain sheet and screwed to wall for protection of test point complete all as specified and directed. | 20 | Each | |
77 | 68 | Supply and fix in repairs single pointed aluminium rod rod 12 mm dia and 300 mm long fixed on the roof including all fittings, fixtures and PCC 1:2:4 type B-1 blocks 100mm x 100mm x 100mm complete all as specified and directed. | 50 | Each | |
78 | 69 | Supply and fix in repairs galvanized iron strip 32x6 mm buried in ground 150 mm below ground including all excavation and earth work connecting at ends, jointing etc complete all as specified and directed. | 50 | RM | |
79 | 70 | M&L for providing earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6.0mm thick buried dirictly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0 sqmm size upto 7.5 meter long by means of bolts,nuts check nuts and washers of all galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-1 and connected to test point including necessary excavation/ earth work in any type of soil/rock strata, PCC (1:3:6) type C-1 earthing chamber, Precast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 with welded wire mesh weight not less than 4kG/Sqm funnel with watering pipe (GI light grade) 20mm dia including GI protection pipe of 15mm dia light grade for earthing lead complete all as specified and directed. | 6 | Each | |
80 | 71 | M&L for providing earthing complete with galvanised steel earth plate electrode 60 x 60cm x 3.15mm thick buried dirictly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth strip of size 32x6mm sqmm size upto 7.5 meter long by means of bolts,nuts check nuts and washers of all galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-1 and connected to test point including necessary excavation/ earth work in any type of soil/rock strata, PCC (1:3:6) type C-1 earthing chamber, Precast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 with welded wire mesh weight not less than 4kG/Sqm funnel with watering pipe (GI light grade) 20mm dia including GI protection pipe of 40mm dia light grade for earthing lead complete all as specified and directed. | 4 | Each | |
81 | 72 | M&L for providing earthing complete with Copper earth plate electrode 60 x 60cm x 3.15mm thick buried dirictly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to copper earth strip of size 20x3mm sqmm size upto 7.5 meter long by means of bolts,nuts check nuts and washers of all galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-1 and connected to test point including necessary excavation/ earth work in any type of soil/rock strata, PCC (1:3:6) type C-1 earthing chamber, Precast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 with welded wire mesh weight not less than 4kG/Sqm funnel with watering pipe (GI light grade) 20mm dia including GI protection pipe of 25mm dia light grade for earthing lead complete all as specified and directed. | 4 | Each | |
82 | 73 | Supply only electronic ballast suitable for tube light of 20 Watt complete all as specified and directed. | 30 | Each | |
83 | 74 | Supply only pin type CFL 36 watt suitable for 2x2 ft ceiling fitting complete all as specified and directed. | 60 | Each | |
84 | 75 | Supply only water,weather and fire proof self adhesive PVC tape roll 7 meter long complete all as specified and directed. | 100 | Each | |
85 | 76 | Note : Fixing of suppy only item shall be measured and paid under respective item of BOQ |