Military Engineer Services-MES has published Maintenance Of Sewage Line , Man Holes Cover In Omq/Smq/Billets And Mes Colony In Domestic Area Under Age B/R-I At Af Stn Jaisalmer. Submission Date for this Tender is 23-08-2019. Manhole cover and frame Tenders in GE(AF) Jaisalmer Rajasthan. Bidders can get complete Tender details and download the document.
Name of Work: PREVENTIVE MAINT OF SEWAGE LINE, MANHOLES, COVER IN OMQ/SMQ/BILLETS AND MES COLONY IN DOMESTIC AREA UNDER AGE B/R-1 AT AF STN JAISALMER. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Demolition of Brick work of stone/boulder masonry, built in cement mortar excluding ashlars facing dressed stone work and pre-cast concrete. | 120.3 | Cum | |
2 | 2 | M&L for square rubble walling Jodhpur type brought up to courses well bonded, bedded and solidly hearted in cement morgtar 1:6. | 90 | Cum | |
3 | 3 | Description all as per srl item No 2 above but except stone | 30 | Cum | |
4 | 4 | Extra over item 15 for hammer dressing to face stones with maximum depressions on face from a stright edge not exc. 20 mm and dressing face beds and joints as specified to SR walling Jodhpur type brought upto courses. | 300 | Sqm | |
5 | 5 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc removing from site all as directed.. | 10 | X Sqm | |
6 | 6 | M&L for Jodhpur stone roof slabs, self faced 7.5 cm to 10cm thick, 25cm to 35cm wide, hoisted and set, jointed and grouted in lime mortar 1:3 or cement motar 1:6 complete) | 100 | Sqm | |
7 | 7 | Demolition and breaking up drain pipes 150 mm dia (salt glazed ware AC or reinforcement concrete set in cement mortar. | 450 | RM | |
8 | 8 | Description all as per srl item No 7 above but 100 mm dia | 100 | RM | |
9 | 9 | M&L 150 mm Salt glazed stonware pipe laid and jointed complete with collars | 250 | RM | |
10 | 10 | M&L 150 mm Salt glazed stonware pipe laid and jointed complete with collars | 250 | RM | |
11 | 11 | M&L 100 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars | 100 | RM | |
12 | 12 | M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for 150 mm dia bore drain pipe for bed concrete including packing under and hunching against the sides of pipe after they are laid and tested complete. | 450 | RM | |
13 | 13 | Description all as per srl item No 12 above but for 100 mm dia | 100 | RM | |
14 | 14 | M&L rendering 15 mm thick on fair faces of stone masonry surface other than fair faces of brick work or on one side of lathing in CM 1:6. | 500 | Sqm | |
15 | 15 | M&L for cement concrete as in coping roof kerbs or mud stops, rounded or chamfered on edges in PCC (1:3:6) using 20 mm graded stone aggregate. | 3.96 | CUM | |
16 | 16 | Excavation in trenches not exceeding 1.50 meter wide or not exceeding 10 square meters in plan area and not exceeding 1.50 meter in depth for foundation in soft loose soil and getting out. | 688.8 | Cum | |
17 | 17 | Returning filling in including spreading, levelling watering and well ramming in layers not exc. 25 cm using excavated soil. | 97.5 | Cum | |
18 | 18 | Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point | 591.3 | Cum | |
19 | 19 | Cutting is to existing manholes for new drains, for removing existing branch drain, making good to walling and rendering cutting out branch channel and making good benching (bore of pipe 150 mm). | 30 | Each | |
20 | 20 | Cleaning of manhole up to 1.00 Mtr deep by balling out water taking out sludge & removing the sludge to a distance exceeding 2.00 Km from the camp area complete all as specified and directed by Engr-in-Charge. | 2500 | Each | |
21 | 21 | Description all as per srl item No 20 above but depth of manhole exceeding 1.00 mtr but n. exc. 2.00mtr. | 800 | Each | |
22 | 22 | Cleaning of sewage line of 100 mm bore by roding and flush water in line after roding to clean the line complete all as directed by Engineer-in-Charge. | 2200 | RM | |
23 | 23 | Description all as per srl item No 22 above but 150 mm bore pipe. | 4000 | RM | |
24 | 24 | Description all as per srl item No 22 above 200 mm bore pipe. | 1800 | RM | |
25 | 25 | M&L for cleaning of septic tank of 300 users capacity by balling out taking out sludge and removing the sludge to a distance exc 1.5 Km but not exceeding 2.00 Km from the camp area including removing stone patti/RCC cover slab and refixing. | 10 | Each | |
26 | 26 | Description all as per srl item No 25 above but 200 users. | 15 | Each | |
27 | 27 | Description all as per srl item No 25 above but 150 users. | 15 | Each | |
28 | 28 | Description all as per srl item No 25 above but 100 users. | 15 | Each | |
29 | 29 | Description all as per srl item No 25 above but 50 users. | 20 | Each | |
30 | 30 | M&L for removal of blockage in between WC and nahani trap/WC to Ist manhole / floor trap to nahani trap etc. by flexible roding and removal the all dirt up to a distance of 100 m all as directed.Note : (i) In case a blockage reoccured with in 7 days the same shall be removed without any extra cost of the Govt. (ii) Cleaning of line in between manhole where in the blockage remove shall deemed to incl the rate coated. (iii) If contractor failed to clear the blockage with in 24 hours from the receipt of complaint, a penalty of Rs 50 per day will charge up to 7 days and after 7 days same will be Rs 100.00 till completion of complaint. | 6500 | Each | |
31 | 31 | M&L 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls fixed in repair. | 200 | RM | |
32 | 32 | Description all as per srl item No 31 above but laid in floors. | 30 | RM | |
33 | 33 | M&l for PVC (SWR) bends any radius for 110 mm dia pipe fixed in repair. | 30 | Each | |
34 | 34 | M&l for PVC (SWR) branch piece single (single Y) equal or unequal for 110 mm dia pipe fixed in repair. | 30 | Each | |
35 | 35 | M&L 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls fixed in repair. | 200 | RM | |
36 | 36 | Description all as per srl item No 31 above but laid in floors. | 50 | RM | |
37 | 37 | S&F for PVC (SWC)bends in repair for 75 mm dia | 30 | Each | |
38 | 38 | M&l for PVC (SWR) branch piece single (single Y) equal or unequal for 75 mm dia pipe fixed in repair. | 30 | RM | |
39 | 39 | M&l for PVC (SWR) bends any radius for 75 mm dia pipe fixed in repair. | 30 | Each | |
40 | 40 | M&L for Cast iron floor trap, for 75 dia pipe with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4). | 20 | Each | |
41 | 41 | S&F Sand cast,100 mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, and fixed to walls incl dismantling of old dia pipe any type. | 300 | RM | |
42 | 42 | S&F Sand cast,75 mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, and fixed to walls incl dismantling of old dia pipe any type. | 150 | RM | |
43 | 43 | S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm dia pipe. | 40 | Each | |
44 | 44 | Description all as per srl item No 43 above but for 75 mm dia | 40 | Each | |
45 | 45 | S&F sand cast Bends 100 mm dia (any radius),diminishing pieces or tapers (larger bore measured) | 40 | Each | |
46 | 46 | Description all as per srl item No 45 above but 75 mm dia | 20 | Each | |
47 | 47 | S&F in repair water closet squatting pan 'Orissa Pattern'of size 580 x 440mm white with integral foot rest (excluding flushing cistern and flush pipe) with P' or 'S' trap complete incl. jointing and provision of PCC (1:5:10) bed as in repairs | 18 | Each | |
48 | 48 | S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) . | 14 | Each | |
49 | 49 | S&F in repairs plastic seat cover any coloured closed pattern with flat bottom and cover and mild steel chromium plated or alluminium hinging device . | 16 | Each | |
50 | 50 | S&F in repair PVC low level flushing cistern 10 Ltr capacity white valve less syphonic action type, with inlet ball valve float handle including PVC flush pipe, 32mm dia and fixed complete all as specified and as directed | 11 | Each | |
51 | 51 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises | 200 | Sqm | |
52 | 52 | M&L 25 mm thick as in base Cement concrete (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) finished even & fair complete all as specified. | 100 | Sqm | |
53 | 53 | M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in floor over and above 15 mm thick screed bed in CM 1:6 complete all as specified. | 100 | Sqm | |
54 | 54 | M&L for glazed ceramic coloured tiles(300x450 x 7mm thick ) on vertical surfaces such as skirting,dados and riser to steps etc set and jointed in neat cement slurry and pointed with white or colored cement to match with colour tile over 15mm thick screed plaster in CM 1:4 on vertical surface of wall. | 100 | Sqm | |
55 | 55 | M&L providing FRC manhole covers with rectangular frame of size 44"x26" MD-10 fixed at site up to satisfactoin of Engr-in-Charge . Incl dismentling of old manhole cover slab. | 135 | Each | |
56 | 56 | M&L providing FRC manhole covers with rectangular frame of size 22"x28" MD-10 fixed at site up to satisfactoin of Engr-in-Charge . Incl dismentling of old manhole cover slab. | 72 | Each | |
57 | 57 | Taking down cement plaster on brick or stone wall etc including raking out joints hacking for keys scrubbing down with water etc. | 500 | Sqm | |
58 | 58 | M&L 15 mm thick rendering on concrete surfaces of plinth wall, ceiling,soffits of chajjas/drop & roof projection facia etc.in CM 1:4 finiched even and smooth with out using extra cement complete all as specified. | 500 | Sqm | |
59 | 59 | M&L Two coats of Camouflage cement based paint over a coat of cement wash with Portland cement slurry to a smooth bodies opaque finish including preparation of New surfaces complete as specified. | 200 | Sqm | |
60 | 60 | Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (Below or above ground level) un-reinforced. | 15 | Cum | |
61 | 61 | M&L 75 mm thick Cement concrete type (1:3:6) C- 2 (using 20mm gradedstone aggregate ) as plinth protection surface fair finished even and smooth without using extra cement. | 200 | SQM | |
62 | 62 | M&L Cast iron 100mm dia Nahani trap, with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1 | 50 | Each | |
63 | 63 | M&L Cast iron 75mm dia Nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) | 20 | Each | |
64 | 64 | M&L Pre-cast cement concrete block masonry with solid blocks PCC(1:4:8) Type D1 using 20 mm , exc. 10 cm in width and setting in mortar CM(1:6), complete | 6 | CUM | |
65 | 65 | M&L for cement concrete as in coping roof kerbs or mud stops, rounded or chamfered on edges in PCC (1:3:6) using 20 mm graded stone aggregate. | 6 | CUM | |
66 | 66 | M&L flush pointing to suare rubble, coursed or uncoursed masonary on concrete block walling but cement mortar(1:4) | 25 | xsqm |