Water Resources and Irrigation Local Bodies Closing in 0 days TDR #21350043

State Plan 2019-20 - Rwss To Omalloor - Supply , Erection And Commissioning Of Brand New Vt Pump Set At Intake Pump House , Supply , Erection And Commissioning Of Brand New Vt Pump Set With The Following Specification . , 1 . Pump - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Water Lubricated Vertical Turbine Pump Set With Bronze / Ss Impeller , Ss Shaft With Ms Erw Column Pipe Of Suitable Diameter And Length . The Pump Set Shall Be Suitable To Be Coupled With Vertical Hollow Shaft Motor . The Duty Condition Of Pump Set Are: Discharge - 2200 Lpm , Total Head 70 Meter , Delivery Size So As To Suit The Existing Pumping Main . , 2 . Motor - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make ( F . L . Speed Of Motor- 1400-1500 Rpm ) Screen Protected Drip Proof Squirrel Cage Vertical Hollow Shaft Induction Motor Suitable For Operation At 415 Volts 3 Phase 50 Hz . Ac Supply For The Above Pump Set . The Motor Should

Issued by Local Bodies · Pathanamthitta District, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
19 Aug 2019
0 days left
EMD
23300
Bank guarantee accepted
Document Fee
2128
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathanamthitta District → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Corrigendum - State Plan 2019-20 - Rwss To Omalloor - Supply , Erection And Commissioning Of Brand New Vt Pump Set At Intake Pump House , Supply , Erection And Commissioning Of Brand New Vt Pump Set With The Following Specification . , 1 . Pump - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Water Lubricated Vertical Turbine Pump Set With Bronze / Ss Impeller , Ss Shaft With Ms Erw Column Pipe Of Suitable Diameter And Length . The Pump Set Shall Be Suitable To Be Coupled With Vertical Hollow Shaft Motor . The Duty Condition Of Pump Set Are: Discharge - 2200 Lpm , Total Head 70 Meter , Delivery Size So As To Suit The Existing Pumping Main . , 2 . Motor - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make ( F . L . Speed Of Motor- 1400-1500 Rpm ) Screen Protected Drip Proof Squirrel Cage Vertical Hollow Shaft Induction Motor Suitable For Operation At 415 Volts 3 Phase 50 Hz . Ac Supply For The Above Pump Set . The Motor Should Confirm To Eefi / Is 325 . Supply Of Suitable Size Best Quality Isi Marked Pn 1 . 6 Heavy Duty Cast Iron Double Flanged Sluice Valve And Reflex Valve Suitable For The Above Pump Set . Fabricating And Connecting Delivery Pipe Of Required Size With Y- Connection And Necessary Joints Made Out Of Suitable Size Ms Pipe In Suitable Length With Required Flanged Joints And Seating On Supports As Per Site Condition . Supply Of Of The Motor Is Including Providing Suitable Concrete Foundation , Cost Of Cement , Sand And Metal Etc . Complete . Flexible Coupling Shall Be Used For Coupling Of Pumps And Motors , 3 . Starter - Supply , Erection Testing And Commissioning Of Suitable Rating ( Fully Automatic Starter With Air Break Contact For Less Than 100Hp And For Above 100Hp Fmca Starters To Be Used ) Starter Suitable For The Above Motor With Over Voltage And Under Voltage Protection , Single Face Preventer , Over Load Relay With Motor Protection Relay With Main Contactor And Bypass Contactor As Per Ie Rules And Code Of Practice Etc . Complete , 4 . Panel Board ( Suitable For Operating Two Pump Sets But One Pump Set At A Time ) -Supply , Erection Testing And Commissioning Of Panel Board Consisting Of Suitable Capacity Tpn Switch With Hrc Fuse / Mccb Voltmeter With Selector Switch , Ammeter With Selector Switch , Fitted With 3 Nos . Of Indicator Lamps With All Fittings As Per Ie Rules , Panel Board Shall Have Facilities And Capacity For Operating 2 Nos Of Motor Of Above Capacity And Should Have Necessary Interlocking Arrangements . The Panel Should Have Provision For Fixing Capacitor And Giving Electric Connection To All Equipments As Per Ie Rules And Code Of Practice . Conducting Satisfactory Trial Etc . Complete As Per The Direction Of Departmental Officers . The Panel Shall Be Fitted On A Common Base Frame On Suitable Foundation . , 5 . Cabling Work - Supply , Laying , Testing And Commissioning Of Suitable Size Xlpe Cables As Per Is Standards For The Above Pumpset From Panel Board To Starter And From Starter To To Motor Considering Energy Conservations , 6 . Earthing - Supply Of Al Materials And Providing Suitable Earthing By Using Suitable Size Pipe / Plate Earthing Gi / Copper Strip Buried In Ground And Giving Double Earthing To Motor , Starter , Panel Board Etc . As Per Ie Standards With Suitable Cable And Connecting The Same To The Earth Pit Provided As Per Is 3043 / 87 And Ie Rules . And Code Of Practice Etc . Complete , 7 . Capacitor - Supply , Erection Testing And Commissioning Of Heavy Duty App Capacitor For The Motor To Get A Power Factor Above 0 . 95 . The Capacitor Shall Confirm To Is 2834 , 8 . Valves - Supply Of Suitable Size Best Quality Heavy Duty Isi Marked Ci Double Flanged Sluice Valve With Pn 1 . 6 And Non Return Valve With Suitable Pressure Rating . Fitting Of Valves Shall Include Proper Rcc Support Especially For Non Return Valves . In Case Of Positive Suction Pump Set Sluice Valve Shuold Be In Suction As Well As Delivery Sides For Easy Repair Works . , 9 . Delivery Pipe Connection - Supply And Fitting Of Suitable Size Delivery Pipe Of Best Quality Ms Of Thickness Not Less Than 10Mm For Length Required At Site And Valves , Specials Etc . Complete And Connecting The Delivery Side Of The Pump With The Pumping Main . , Total Head = 70 M . Discharge = 2200 Lpm . Rpm = 1400 -1500 Range .

AI Tender Summary

OUR REF NO 21350043
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 19-08-2019
Authority
Authority Name Kerala Water Authority
Work Description Corrigendum - State Plan 2019-20 - Rwss To Omalloor - Supply , Erection And Commissioning Of Brand New Vt Pump Set At Intake Pump House , Supply , Erection And Commissioning Of Brand New Vt Pump Set With The Following Specification . , 1 . Pump - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Water Lubricated Vertical Turbine Pump Set With Bronze / Ss Impeller , Ss Shaft With Ms Erw Column Pipe Of Suitable Diameter And Length . The Pump Set Shall Be Suitable To Be Coupled With Vertical Hollow Shaft Motor . The Duty Condition Of Pump Set Are: Discharge - 2200 Lpm , Total Head 70 Meter , Delivery Size So As To Suit The Existing Pumping Main . , 2 . Motor - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make ( F . L . Speed Of Motor- 1400-1500 Rpm ) Screen Protected Drip Proof Squirrel Cage Vertical Hollow Shaft Induction Motor Suitable For Operation At 415 Volts 3 Phase 50 Hz . Ac Supply For The Above Pump Set . The Motor Should Confirm To Eefi / Is 325 . Supply Of Suitable Size Best Quality Isi Marked Pn 1 . 6 Heavy Duty Cast Iron Double Flanged Sluice Valve And Reflex Valve Suitable For The Above Pump Set . Fabricating And Connecting Delivery Pipe Of Required Size With Y- Connection And Necessary Joints Made Out Of Suitable Size Ms Pipe In Suitable Length With Required Flanged Joints And Seating On Supports As Per Site Condition . Supply Of Of The Motor Is Including Providing Suitable Concrete Foundation , Cost Of Cement , Sand And Metal Etc . Complete . Flexible Coupling Shall Be Used For Coupling Of Pumps And Motors , 3 . Starter - Supply , Erection Testing And Commissioning Of Suitable Rating ( Fully Automatic Starter With Air Break Contact For Less Than 100Hp And For Above 100Hp Fmca Starters To Be Used ) Starter Suitable For The Above Motor With Over Voltage And Under Voltage Protection , Single Face Preventer , Over Load Relay With Motor Protection Relay With Main Contactor And Bypass Contactor As Per Ie Rules And Code Of Practice Etc . Complete , 4 . Panel Board ( Suitable For Operating Two Pump Sets But One Pump Set At A Time ) -Supply , Erection Testing And Commissioning Of Panel Board Consisting Of Suitable Capacity Tpn Switch With Hrc Fuse / Mccb Voltmeter With Selector Switch , Ammeter With Selector Switch , Fitted With 3 Nos . Of Indicator Lamps With All Fittings As Per Ie Rules , Panel Board Shall Have Facilities And Capacity For Operating 2 Nos Of Motor Of Above Capacity And Should Have Necessary Interlocking Arrangements . The Panel Should Have Provision For Fixing Capacitor And Giving Electric Connection To All Equipments As Per Ie Rules And Code Of Practice . Conducting Satisfactory Trial Etc . Complete As Per The Direction Of Departmental Officers . The Panel Shall Be Fitted On A Common Base Frame On Suitable Foundation . , 5 . Cabling Work - Supply , Laying , Testing And Commissioning Of Suitable Size Xlpe Cables As Per Is Standards For The Above Pumpset From Panel Board To Starter And From Starter To To Motor Considering Energy Conservations , 6 . Earthing - Supply Of Al Materials And Providing Suitable Earthing By Using Suitable Size Pipe / Plate Earthing Gi / Copper Strip Buried In Ground And Giving Double Earthing To Motor , Starter , Panel Board Etc . As Per Ie Standards With Suitable Cable And Connecting The Same To The Earth Pit Provided As Per Is 3043 / 87 And Ie Rules . And Code Of Practice Etc . Complete , 7 . Capacitor - Supply , Erection Testing And Commissioning Of Heavy Duty App Capacitor For The Motor To Get A Power Factor Above 0 . 95 . The Capacitor Shall Confirm To Is 2834 , 8 . Valves - Supply Of Suitable Size Best Quality Heavy Duty Isi Marked Ci Double Flanged Sluice Valve With Pn 1 . 6 And Non Return Valve With Suitable Pressure Rating . Fitting Of Valves Shall Include Proper Rcc Support Especially For Non Return Valves . In Case Of Positive Suction Pump Set Sluice Valve Shuold Be In Suction As Well As Delivery Sides For Easy Repair Works . , 9 . Delivery Pipe Connection - Supply And Fitting Of Suitable Size Delivery Pipe Of Best Quality Ms Of Thickness Not Less Than 10Mm For Length Required At Site And Valves , Specials Etc . Complete And Connecting The Delivery Side Of The Pump With The Pumping Main . , Total Head = 70 M . Discharge = 2200 Lpm . Rpm = 1400 -1500 Range .
Basic Detail
Tender No 2019_KWA_288676_1
Bidding Type Tender
Location
City Pathanamthitta District
State Kerala
Key Dates
Publish Date 24 Jul 2019
Submission Date 19 Aug 2019
Open Date 21 Aug 2019
Finance
Tender Value Ref. Documents
Tender Fee 2128
EMD 23300
Exemption Not Available
Document List
DEE27FDC-ECCD-405F-A9EE-9A57641815BA.html
Tendernotice_1.pdf
013SpecialConditions.pdf
BOQ_392974.xls
013Form83.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 24, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 21, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

DEE27FDC-ECCD-405F-A9EE-9A57641815BA.html

pdf

Tendernotice_1.pdf

pdf

013SpecialConditions.pdf

xls

BOQ_392974.xls

pdf

013Form83.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders