Water Resources and Irrigation Local Bodies Closing in 0 days TDR #21326993

Supply , Erection And Commissioning Of Brand New Centrifugal Pump Set ( 2 Nos . ) At Malankavu Treatment Plant Of Water Supply Scheme To Kadampanadu Panchayath

Issued by Local Bodies · Pathanamthitta District, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Aug 2019
0 days left
EMD
20600
Bank guarantee accepted
Document Fee
1904
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathanamthitta District → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply , Erection And Commissioning Of Brand New Centrifugal Pump Set ( 2 Nos . ) At Malankavu Treatment Plant Of Water Supply Scheme To Kadampanadu Panchayath , Supply , Erection And Commissioning Of 2 Nos . Brand New Cf Pump Set With The Following Specification . , 1 . Pump - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Centrifugal Pump Sets With Bronze / Ss Impeller , Ss Shaft And Ci Pump Casing With Suitable Type Base Plate With Coupling , Coupling Guard Foundation Bolts , Nuts Etc . Complete Suitable For Coupling The Pump And Motor Above The Plate Etc . Complete Including Providing Suitable Concrete Foundation Including Cost Of Cement , Sand And Metal Etc . Complete , 2 . Motor - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Horizontal Solid Shaft Foot Mounted Tefc Squirrel Cage Induction Motor Suitable For The Above Pump Working 3 Phase 50 Hz Ac Supply , Working Voltage 415V . The Motor Shall Confirm To Eefi / Is 325 Including Providing Suitable Concrete Foundation Including Cost Of Cement , Sand And Metal Etc . Complete . Flexible Coupling Shall Be Used For Coupling Of Pumps And Motors , 3 . Starter - Supply , Erection Testing And Commissioning Of Suitable Rating ( Fully Automatic Starter With Air Break Contact For Less Than 100Hp And For Above 100Hp Fmca Starters To Be Used ) Starter Suitable For The Above Motor With Over Voltage And Under Voltage Protection , Single Face Preventer , Over Load Relay With Motor Protection Relay With Main Contactor And Bypass Contactor As Per Ie Rules And Code Of Practice Etc . Complete , 4 . Panel Board ( Suitable For Operating Two Pump Sets But One Pump Set At A Time ) Supply , Erection Testing And Commissioning Of Cubical Type Floor Mounted Ms Fabricated Dust And Vermin Proof Common Control Panel Board Consisting Of 1No . Suitable Capacity Mccb As Incomer And 2 Nos . Suitable Capacity Mccb As Out Going ( The Two Mccbs Are Interlocking With Each Other ) Providing Suitable Size Aluminium Bus Bar Interconnect The Above Mccbs And Fitted With 3 Nos . Of Indicator Lamps , 1No . Volt Meter With Selector Switch , 1No . Ammeter With Selector Switch Etc . Complete And Provided With A Common Earth Bus For The Entire Panel And Interconnect With The Mccbs As Per Ie Rules And Code Of Practice . The Panel Shall Be Fitted On A Common Base Frame On Suitable Foundation . , 5 . Cabling Work - Supply , Laying , Testing And Commissioning Of Suitable Size Xlpe Cables For The Above Pump Set From Panel Board To Starter And From Starter To Motor Considering Energy Conservations . , 6 . Earthing - Supply Of Al Materials And Providing Suitable Earthing By Using Suitable Size Pipe / Plate Earthing Gi / Copper Strip Buried In Ground And Giving Double Earthing To Motor , Starter , Panel Board Etc . As Per Ie Standards . , 7 . Capacitor - Supply , Erection Testing And Commissioning Of Heavy Duty App Capacitor For The Motor To Get A Power Factor Above 0 . 95 . The Capacitor Shall Confirm To Is 2834 . , 8 . Valves - Supply Of Suitable Size Best Quality Heavy Duty Isi Marked Ci Double Flanged Sluice Valve And Non Return Valve With Suitable Pressure Rating . Fitting Of Valves Shall Include Proper Rcc Support Especially For Non Return Valves . In Case Of Positive Suction Pump Set Sluice Valve Should Be In Suction As Well As Delivery Sides For Easy Repair Works . , 9 . Suction And Delivery Pipe Connection - Supply And Fitting Of Suitable Size Best Quality Gi / Ms Pipe Of Thickness Not Less Than 8Mm For A Total Length Of 10M . Suitable For The Above Pump Set And Suitable Size Foot Valve And Connecting The Suction Pipe And Valve With Suitable Flanges , Nut And Bolts Ir Sheet Etc . Complete And Connecting The Delivery Side Of The Pump With The Valves And Suitable Specials To Connect With The Pumping Main . , Discharge = 2100 Lpm Total Head = 70 M Rpm = 1400-1500 Range .

BOQ

Name of Work: State Plan 2019 - WSS to Kadampanadu - Supply, erection and commissioning of brand new Centrifugal pump set (2 Nos.) at Malankavu Treatment Plant of water supply scheme to Kadampanadu Panchayath.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Supply, erection and commissioning of 2 Nos. brand new CF pump set with the following specification.\nBI01010001010000000000000515BI01000011132set
21.11. Pump - Supply, erection testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts, nuts etc. complete suitable for coupling the pump and motor above the plate etc. complete including providing suitable concrete foundation including cost of cement, sand and metal etc. completeBI01010001010000000000000515BI0100001114
31.22. Motor - Supply, erection testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement , sand and metal etc. complete. Flexible coupling shall be used for coupling of pumps and motorsBI01010001010000000000000515BI0100001115
41.33. Starter - Supply, erection testing and commissioning of suitable rating (Fully automatic starter with air break contact for less than 100HP and for above 100HP FMCA starters to be used) starter suitable for the above motor with over voltage and under voltage protection, single face preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. completeBI01010001010000000000000515BI0100001116
51.44. Panel board (Suitable for operating two pump sets but one pump set at a time) Supply ,erection testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1No. Suitable capacity MCCB as incomer and 2 Nos. Suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar interconnect the above MCCBs and fitted with 3 Nos. of indicator lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch etc. complete and provided with a common earth bus for the entire panel and interconnect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation.BI01010001010000000000000515BI0100001117
61.55. Cabling work - Supply , laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservations.BI01010001010000000000000515BI0100001118
71.66. Earthing - Supply of al materials and providing suitable earthing by using suitable size pipe/plate earthing GI/Copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.BI01010001010000000000000515BI0100001119
81.77. Capacitor - Supply ,erection testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. the capacitor shall confirm to IS 2834.BI01010001010000000000000515BI0100001120
91.88. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works .BI01010001010000000000000515BI0100001121
101.99. Suction and delivery pipe connection - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.BI01010001010000000000000515BI0100001122
112Discharge = 2100 lpm\nTotal Head = 70 m\nRPM = 1400-1500 range.BI01010001010000000000000515BI0100001123

AI Tender Summary

OUR REF NO 21326993
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 22-08-2019
Authority
Authority Name Kerala Water Authority
Work Description Supply , Erection And Commissioning Of Brand New Centrifugal Pump Set ( 2 Nos . ) At Malankavu Treatment Plant Of Water Supply Scheme To Kadampanadu Panchayath , Supply , Erection And Commissioning Of 2 Nos . Brand New Cf Pump Set With The Following Specification . , 1 . Pump - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Centrifugal Pump Sets With Bronze / Ss Impeller , Ss Shaft And Ci Pump Casing With Suitable Type Base Plate With Coupling , Coupling Guard Foundation Bolts , Nuts Etc . Complete Suitable For Coupling The Pump And Motor Above The Plate Etc . Complete Including Providing Suitable Concrete Foundation Including Cost Of Cement , Sand And Metal Etc . Complete , 2 . Motor - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Horizontal Solid Shaft Foot Mounted Tefc Squirrel Cage Induction Motor Suitable For The Above Pump Working 3 Phase 50 Hz Ac Supply , Working Voltage 415V . The Motor Shall Confirm To Eefi / Is 325 Including Providing Suitable Concrete Foundation Including Cost Of Cement , Sand And Metal Etc . Complete . Flexible Coupling Shall Be Used For Coupling Of Pumps And Motors , 3 . Starter - Supply , Erection Testing And Commissioning Of Suitable Rating ( Fully Automatic Starter With Air Break Contact For Less Than 100Hp And For Above 100Hp Fmca Starters To Be Used ) Starter Suitable For The Above Motor With Over Voltage And Under Voltage Protection , Single Face Preventer , Over Load Relay With Motor Protection Relay With Main Contactor And Bypass Contactor As Per Ie Rules And Code Of Practice Etc . Complete , 4 . Panel Board ( Suitable For Operating Two Pump Sets But One Pump Set At A Time ) Supply , Erection Testing And Commissioning Of Cubical Type Floor Mounted Ms Fabricated Dust And Vermin Proof Common Control Panel Board Consisting Of 1No . Suitable Capacity Mccb As Incomer And 2 Nos . Suitable Capacity Mccb As Out Going ( The Two Mccbs Are Interlocking With Each Other ) Providing Suitable Size Aluminium Bus Bar Interconnect The Above Mccbs And Fitted With 3 Nos . Of Indicator Lamps , 1No . Volt Meter With Selector Switch , 1No . Ammeter With Selector Switch Etc . Complete And Provided With A Common Earth Bus For The Entire Panel And Interconnect With The Mccbs As Per Ie Rules And Code Of Practice . The Panel Shall Be Fitted On A Common Base Frame On Suitable Foundation . , 5 . Cabling Work - Supply , Laying , Testing And Commissioning Of Suitable Size Xlpe Cables For The Above Pump Set From Panel Board To Starter And From Starter To Motor Considering Energy Conservations . , 6 . Earthing - Supply Of Al Materials And Providing Suitable Earthing By Using Suitable Size Pipe / Plate Earthing Gi / Copper Strip Buried In Ground And Giving Double Earthing To Motor , Starter , Panel Board Etc . As Per Ie Standards . , 7 . Capacitor - Supply , Erection Testing And Commissioning Of Heavy Duty App Capacitor For The Motor To Get A Power Factor Above 0 . 95 . The Capacitor Shall Confirm To Is 2834 . , 8 . Valves - Supply Of Suitable Size Best Quality Heavy Duty Isi Marked Ci Double Flanged Sluice Valve And Non Return Valve With Suitable Pressure Rating . Fitting Of Valves Shall Include Proper Rcc Support Especially For Non Return Valves . In Case Of Positive Suction Pump Set Sluice Valve Should Be In Suction As Well As Delivery Sides For Easy Repair Works . , 9 . Suction And Delivery Pipe Connection - Supply And Fitting Of Suitable Size Best Quality Gi / Ms Pipe Of Thickness Not Less Than 8Mm For A Total Length Of 10M . Suitable For The Above Pump Set And Suitable Size Foot Valve And Connecting The Suction Pipe And Valve With Suitable Flanges , Nut And Bolts Ir Sheet Etc . Complete And Connecting The Delivery Side Of The Pump With The Valves And Suitable Specials To Connect With The Pumping Main . , Discharge = 2100 Lpm Total Head = 70 M Rpm = 1400-1500 Range .
Basic Detail
Tender No 032/2019-20/EE/PH/PTA
Bidding Type Tender
Location
City Pathanamthitta District
State Kerala
Key Dates
Publish Date 08 Aug 2019
Submission Date 22 Aug 2019
Open Date 24 Aug 2019
Finance
Tender Value Ref. Documents
Tender Fee 1904
EMD 20600
Exemption Not Available
Document List
Tendernotice_1.pdf
032SpecialConditions.pdf
032Form83.pdf
997AA860-9176-44D9-9190-FD6D36A9DEDA.html
BOQ_398171.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 08, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 22, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 24, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

032SpecialConditions.pdf

pdf

032Form83.pdf

html

997AA860-9176-44D9-9190-FD6D36A9DEDA.html

xls

BOQ_398171.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders