Replacement Of Air Conditioner Units In Passenger Boarding Bridges At Visakhapatnam Airport
Tender Value
11.94 Lakhs
Estimated cost
Bid Submission
09 Aug 2019
0 days left
EMD
23884
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
visakahpatnam → Andhra Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Replacement Of Air Conditioner Units In Passenger Boarding Bridges At Visakhapatnam Airport
BOQ
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
|---|---|---|---|---|---|
| 1 | 1 | Supply, Installation, Testing & Commissioning of 1.5 TR Split DC inverter Cool type 5 star rated Air Conditioner of wall mounting type consisting of non-ductable type room units (fan coil) with cord less remote control and one number out door (copper coil) condensing unit comprising of 1 No. 1.5TR hermetically sealed rotary compressor suitable for operation on single phase, 230 volts, 50Hz, AC supply including fixing the outdoor unit on a fabricated MS stand as per the site requirement and fixing of room (fan coil) unit, providing and making interconnections between room unit and condensing upto a length of 3 mtrs comprising of the following including first charge of refrigerant etc complete as required. as per the enclosed approved list as per the enclosed approved make list. a) 1\" dia drain PVC pipe. b) 1/4\" dia insulated copper pipe - Liquid line or suitable as recommended by OEM. c) 1/2\" dia insualted copper pipe - suction or suitable as recommended by OEM. d) 3 C x 2.5 sq.mm copper conductor PVC FRLS insulated cable and in suitable PVC conduit or suitable as recommended by OEM. | 1 | 6 | Job |
| 2 | 2 | Supply, Installation, Testing & Commissioning of 2.0 TR Split DC inverter Cool type 5 star rated Air Conditioner of wall mounting type consisting of non-ductable type room units (fan coil) with cord less remote control and one number out door (copper coil) condensing unit comprising of 1 No. 2.0 TR hermetically sealed rotary compressor suitable for operation on single phase, 230 volts, 50Hz, AC supply including fixing the outdoor unit with a fabricated MS stand as per the site requirement and fixing of room (fan coil) unit, providing and making interconnections between room unit and condensing upto a length of 3 mtrs comprising of the following including first charge of refrigerant etc complete as required. as per the enclosed approved list as per the enclosed approved make list. a) 1\" dia drain PVC pipe. b) 5/8\" dia insulated copper pipe - Liquid line or suitable as recommended by OEM. c) 3/8\" dia insualted copper pipe - suction or suitable as recommended by OEM. d) 5 C x 2.5 sq.mm copper conductor PVC FRLS insulated cable as recommended by OEM. | 2 | 4 | Job |
| 3 | 3 | Supply, Installation, Testing and Commissioning of 3.0 TR split DC inverter cassette type non ductable room unit, cord less remote controled and one number outdoor unit (copper coil) condensing unit comprising of 01 no. 3.0TR hermetically sealed rotary compressor suitable for operation on Three phase, 415 volts, 50 Hz, AC supply including fixing the out door unit with supply and fixing of a fabricated MS stand and as per the site requirement and fixing of room(indoor) unit in the false ceiling including making good the same, Providing and making interconnections between room unit and condensing unit upto a length of 3 mtrs comprising of the following including first charge of refrigerant etc., complete as required. as per the enclosed approved list. \na) 1\" dia drain PVC pipe.\nb) 5/8\" dia insulated copper pipe - Liquid line or suitable as recommended by OEM.\nc) 3/8\" dia insualted copper pipe - suction or suitable as recommended by OEM.\nd) 5 C x 2.5 sq.mm copper conductor PVC FRLS insulated cable recommended by OEM. | 3 | 2 | Job |
| 4 | 4 | Supply, Installation, Testing and Commissioning of 4.0 TR Vertical Split type Air Conditioner of floor mounting type consisting of non-ductable type room units (fan coil) with cord less remote control and one number out door (copper coil) condensing unit comprising of 1 No. 4.0 TR hermetically sealed Scroll compressor suitable for operation on Three phase, 415 volts, 50 Hz, AC supply including fixing the out door unit on a fabricated MS stand as per the site requirement and fixing of room (fan coil) unit. Providing and making interconnections between room unit and condensing upto a length of 3 mtrs comprising of the following including first charge of refrigerant etc., complete as required. as per the enclosed approved list. a) 1\" dia drain PVC pipe. b) 1/2\" dia insulated copper pipe - Liquid line or suitable as recommended by OEM. c) 3/4\" dia insualted copper pipe - suction or suitable as recommended by OEM. d) 5 C x 2.5 sq.mm copper conductor PVC FRLS insulated cable as recommended by OEM. | 4 | 2 | Job |
| 5 | 5 | Supply, Installation, Testing and Commissioning of 3.0 TR Vertical Split type Air Conditioner of floor mounting type consisting of non-ductable type room units (fan coil) with cord less remote control and one number out door (copper coil) condensing unit comprising of 1 No. 3.0 TR hermetically sealed Scroll compressor suitable for operation on Three phase, 415 volts, 50 Hz, AC supply including fixing the out door unit on a fabricated MS stand as per the site requirement and fixing of room (fan coil) unit. Providing and making interconnections between room unit and condensing upto a length of 3 mtrs comprising of the following including first charge of refrigerant etc., complete as required. as per the enclosed approved list. a) 1\" dia drain PVC pipe. b) 1/2\" dia insulated copper pipe - Liquid line or suitable as recommended by OEM. c) 3/4\" dia insualted copper pipe - suction or suitable as recommended by OEM. d) 5 C x 2.5 sq.mm copper conductor PVC FRLS insulated cable as recommended by OEM. | 5 | 1 | Job |
| 6 | 6 | Supply, Installation, Testing and Commissioning of 2.0 TR split DC inverter ceiling type non ductable room unit, cord less remote control and one number outdoor unit (copper coil) condensing unit comprising of 01 no. 2.0TR hermetically sealed rotary compressor suitable for operation on single phase,230 volts, 50 Hz, AC supply including fixing the out door unit with supply and fixing of a fabricated MS stand and as per the site requirement and fixing of room(indoor) unit in the false ceiling including making good the same, Providing and making interconnections between room unit and condensing unit upto a length of 3 mtrs comprising of the following including first charge of refrigerant etc., complete as required. as per the enclosed approved list. \na) 1\" dia drain PVC pipe.\nb) 5/8\" dia insulated copper pipe - Liquid line or suitable as recommended by OEM.\nc) 3/8\" dia insualted copper pipe - suction or suitable as recommended by OEM.\nd) 5 C x 2.5 sq.mm copper conductor PVC FRLS insulated cable recommended by OEM. | 6 | 3 | Job |
| 7 | 7 | a)Extra supply and installation for insulated copper pipe for vertical and Casette AC of following sizes 5/8'' or 3/8'' for suction and discharge pipings for Vertical and Casette AC b)Extra for supply and installation Drain pipe for Vertical and Casette AC per meter c)5 C x 2.5 sq.mm copper conductor PVC FRLS insulated cable as recommended by OEM. | 7 | 29 | Mtr |
| 8 | 8 | a)Extra supply and installation for insulated Copper pipe for Inverter Split AC per meter of following sizes 1/2'' and 3/4'' for Suction and Discharge pipings for Inverter Split Acs b)Extra supply and installation for Drain pipe for Inverter Split c)AC 3 C x 2.5 sq.mm copper conductor PVC FRLS insulated cable as recommended by OEM. | 8 | 37 | Mtr |
AI Tender Summary
Tender Timeline
Aug 03, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedAug 09, 2019
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 16, 2019
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender