Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #21267685

Repairs/ Maintenance Of Dg Sets , Amf Panels And Allied E/M Works And Repairs/ Maintenance Of Water Supply Pipe Lines Submersible Pump Sets Including Misc E/M Works At Cqae Etc Under Age E/M No1 Of Ge ( Utility-Ii ) Visakhapatnam

Issued by Statutory Bodies & Commissions/Committees · GE UTILITY II VISAKHAPATNAM, Andhra Pradesh
Tender Value
45 Lakhs
Estimated cost
Bid Submission
22 Aug 2019
0 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
GE UTILITY II VISAKHAPATNAM → Andhra Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repairs/ Maintenance Of Dg Sets , Amf Panels And Allied E/M Works And Repairs/ Maintenance Of Water Supply Pipe Lines Submersible Pump Sets Including Misc E/M Works At Cqae Etc Under Age E/M No1 Of Ge ( Utility-Ii ) Visakhapatnam , M&L For Maintenance Of Diesel Engine Connected With Dg Set 200 Kva For B Check As Per Recomendation Of Manufacturers Instructions Including Replacement Of Filters , Accessories Like Fuel Filter With Ring , Air Filter And Ring , Super Bypass Filter Element , O Ring Seal , Oil Filter And Engine Oil Complete All As Specified And Directed By Engr-In-Charge . , All As Per Sl Item No . 1 Above But Dg Set 125 Kva , All As Per Sl Item No . 1 Above But Dg Set 100 Kva , All As Per Sl Item No . 1 Above But Dg Set 62 . 5 Kva , All As Per Sl Item No . 1 Above But Dg Set 30 Kva , M&L For Replacement Of Air Cleaner Filter To 200 Kva Dg Set Matching With The Existing One All As Per Manufacturer Recommendation Complete All As Specified And Directed By Engr-In-Charge . , All As Per Sl Item No . 6 Above But Dg Set 125 Kva , All As Per Sl Item No . 6 Above But Dg Set 100 Kva , All As Per Sl Item No . 6 Above But Dg Set 62 . 5 Kva , All As Per Sl Item No . 6 Above But Dg Set 30 Kva , Supply And Filling Engine Oil 15 W 40 Grade Castrol Crb For Topping Up ( Including Draining Out Old Oil From Gen Set ) Complete All As Specified And Directed . Make : Servo/ Valvoline/ Hpcl , M&L For Repair Of Diesel Engine Of Capacity Upto 75 Kva By Dismantling The Sub-Assemblies Such As Fuel Pump , Fuel Injection , Governor , Turbo-Charger , Radiator , Oil Cooler , Engine Heads , Rocker Arms , Self Starter , Dynamo-Engine Wiring , Terminal Contacts And Safety Controls Etc . , Including Replacement Of Spare Parts As Required And Re-Assembling The Sub-Assemblies After Carrying Out Necessary Repairs Including Testing And Commissioning Complete All As Directed By Engineer-In-Charge . Notes: 1 . Spare Required Shall Be Measured And Paid Separately Under Relevant Items Of Boq . 2 . Repairs And Calibration Of Sub-Assemblies Shall Be Measured And Paid Separately Under Relevant Items Of Boq . , All As Per Sl Item No . 12 Above But Dg Set Of Capacity 100 To 125 Kva , All As Per Sl Item No . 12 Above But Dg Set Of Capacity 200 Kva , Supply Only The Following Spares In The Engine Of Make Kirloskar/Cummins , Radiator Fan Guard , Dynamo Belt , Bend Hose , Radiator Connection Hoses , Radiator Connection Ms Pipes 2 1/4Inner Dia Length 1 Feet , Radiator Hose Clamps , Top Cover Gaskets 6 Nos , Lubricant Oil Drain Hose , Radiator Mounting Pads , Lubricant Oil Filter , M&L For Repair And Calibration Of Governor As Per Calibration Procedure And Norms Suitable For Dg Set Of Capacity Upto 75 Kva Complete All As Directed By Engineer-In-Charge , All As Per Sl Item No . 16 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 16 Above But Dg Set Of Capacity 200 Kva , M&L For Repair And Calibration Of Turbo Super Charger Suitable For Dg Set Of Capcity Upto 75 Kva As Per Calibration Procedure , Norms And As Per Manufacturers Guide Lines Including Replacement Of Turbo Supply Hoses , Discharge Hoses , Clamps And De-Scaling Of Turbo Charger Complete All As Specified And Directed . , All As Per Sl Item No . 19 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 19 Above But Dg Set Of Capacity 200 Kva , M&L For Repair And Calibration Of Fuel Pump & Injectors Suitable For Dg Set Of Capcity Upto 75 Kva As Per Calibration Procedure , Norms And As Per Manufacturers Guide Lines Including Replacement Of Unserviceable O Rings , Plungers And Cups Etc . , Complete All As Specified And Directed . , All As Per Sl Item No . 22 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 22 Above But Dg Set Of Capacity 200 Kva , M&L For Repair And Calibration Of Self Starter Suitable For Dg Set Of Capcity Upto 75 Kva Including Rewinding Of Commutator , Replacing Carbon Brush Set , Carbon Brush Holder , King Pins Holders , Armature Check Nuts , Body Screws , Clutch Plate Assembly And Solenoid Etc . , As Required Complete All As Specified And As Directed By Engr-In-Charge . , All As Per Sl Item No . 25 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 25 Above But Dg Set Of Capacity 200 Kva , M&L For Descaling Of Radiator Suitable For Dg Set Of Capcity Upto 75 Kva By Dismantling The Upper And Lower Tank , Cleaning The Core Pipes And Components With Cleaning Chemicals , Arresting The Leaking Core By Brazing/ Dummy With Lead Including Cleaning Of Upper And Lower Tanks , Replacing The Upper And Lower Tank Gaskets And Required Nuts , Bolts , Painting With One Coat Of Synthetic Enamel Paint Of Approved Colour , Refixing The Same Including Testing Complete All As Specified And Directed . , All As Per Sl Item No . 28 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 28 Above But Dg Set Of Capacity 200 Kva , M&L For Servicing Of Alternator Of Any Make Suitable For Dg Set Of Capcity Upto 75 Kva By Opening The End Cover , Cleaning The Dust And Rust Formed Over The Terminals , Cleaning With Ctc Liquid , Checking Of Diodes , Winding , Isolating Transformer And Avr Panel And Applying Dr . Beck Paint For Insulation Improvement Over The Strips/ Winding And Drying Till Getting Sasfactory Insulation Resistance Complete , Refixing The Covers Including Testing Complete All As Specified And Directed . , All As Per Sl Item No . 31 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 31 Above But Dg Set Of Capacity 200 Kva , Supply Only The Following Spares Suitable For Dg Set Of Capacity 62 . 5/75/100 Kva , Valve Guide , Exhaust Valve , Intake Valve , Valve Spring , Valve Lock , Valve Set , Gasket Kit , Supply Only The Following Spares Suitable For Dg Set Of Capacity125/200 Kva , Valve Guide , Exhaust Valve , Intake Valve , Valve Spring , Valve Lock , Valve Set , Gasket Kit , Repair To Amf Panel Of 30 To 82 . 5 Kva Dg Set , By Tracing Out The Defects And Replacing Unserviceable Parts Including Control Wiring Complete All As Specified And Directed By Engr-In-Charge . Note: Spares Shall Be Measured And Paid Separately Under Relevent Items Of Boq And Labour Element For Fixing Parts Shall Be Deemed To Be Included In The Quoted Rate . , All As Per Item No . 36 Above But Amf Panel Of 100 To 200 Kva Dg Set , Repair To The Self Starter Of Capacity 24 Volts Connected To Dg Sets Including Replacement Of Defective Winding Etc Complete All As Directed By Engr -In Charge . , All As Per Sl . Item No . 38 Above But Of Capacity 12 Volts , Repair To Dynamo Of Capacity 24 Volts Connected To Dg Sets Of Any Capacity Including Replacement Of Defective Spare Parts And Winding Complete All As Directed By Engr-In-Charge . , All As Per Sl . Item No . 40 Above But 12 Volts Capacity , Surface Dressing In Soft/Loose Soil Not Exceeding 15 Cm Deep , Cutting/ Cleaning Of Branches , Bushes/Plants/ Grass Obstructing The Pipe Line/ Valve Chambers/ Sumps/Ohts And Path On Either Sides Of Water Supply Installations Area Including Disposal The Material Up To A Distance Not Execeding 50 M Complete All As Specified And Directed By Engineer-In-Charge . , Supply And Replace On Load Change Over Switch 4 Pole , 415 Volts , 50 Hz , 400 Amps , In Open Execution Fixing In Existing Panel Including Necessary Modification In Panel Complete All As Specified And Directed . , All As Per Sl Item No . 43 Above But 200 Amps Capacity , Supply And Filling Of Coolant For Radiator Of Dg Set Of Any Capacity At Various Locations Complete All As Directed , Supply , Fix , Testing And Commissioning New 12 Volts , 180 Ah Lead Acid Battery Including Removing Existing Unserviceable One Complete All As Directed , Supply , Fix , Testing And Commissioning New 24 Volts , 180 Ah Lead Acid Battery Including Removing Existing Unserviceable O

BOQ

Sl.No. Item Description Item Code / Make Quantity Units
1 1 M&L for maintenance of diesel Engine connected with DG Set 200 KVA for 'B' check as per recomendation of manufacturers instructions including replacement of filters, accessories like fuel filter with ring, Air filter and ring , super bypass filter element , 'O' Ring seal, Oil filter and engine Oil complete all as specified and directed by Engr-in-charge. 1 Job
2 2 All as per SL item No.1 above but DG set 125 KVA 2 Job
3 3 All as per SL item No.1 above but DG set 100 KVA 3 Job
4 4 All as per SL item No.1 above but DG set 62.5 KVA 3 Job
5 5 All as per SL item No.1 above but DG set 30 KVA 1 Job
6 6 M&L for replacement of air cleaner filter to 200 KVA DG set matching with the existing one all as per manufacturer recommendation complete all as specified and directed by Engr-in-charge. 1 Job
7 7 All as per SL item No.6 above but DG set 125 KVA 2 Job
8 8 All as per SL item No.6 above but DG set 100 KVA 3 Job
9 9 All as per SL item No.6 above but DG set 62.5 KVA 3 Job
10 10 All as per SL item No.6 above but DG set 30 KVA 1 Job
11 11 Supply and filling Engine oil 15 W 40 Grade Castrol CRB for topping up (including draining out old oil from Gen Set) complete all as specified and directed.\nMake : Servo/ Valvoline/ HPCL 200 Litre
12 12 M&L for repair of Diesel Engine of capacity upto 75 KVA by dismantling the Sub-assemblies such as fuel pump, fuel injection, Governor, turbo-charger, radiator, oil cooler, engine heads, rocker arms, self starter, dynamo-engine wiring, terminal contacts and safety controls etc., including replacement of spare parts as required and re-assembling the sub-assemblies after carrying out necessary repairs including testing and commissioning complete all as directed by Engineer-in-charge.\nNotes: 1. Spare required shall be measured and paid separately under relevant items of BOQ.\n2. Repairs and calibration of Sub-assemblies shall be measured and paid separately under relevant items of BOQ. 3 Job
13 13 All as per SL item No.12 above but DG set of capacity 100 to 125 KVA 3 Job
14 14 All as per SL item No.12 above but DG set of capacity 200 KVA 1 Job
15 15 Supply only the following spares in the Engine of Make Kirloskar/Cummins
16 15.01 Radiator fan guard 6 Each
17 15.02 Dynamo Belt 6 Each
18 15.03 Bend hose 6 Each
19 15.04 Radiator Connection hoses 6 Each
20 15.05 Radiator Connection MS Pipes 2 1/4\"inner dia length 1 feet 6 Each
21 15.06 Radiator hose clamps 6 Set
22 15.07 Top cover gaskets 6 NOS 6 Set
23 15.08 Lubricant oil drain hose 6 Set
24 15.09 Radiator mounting pads 6 Each
25 15.1 Lubricant oil filter 6 Each
26 16 M&L for Repair and Calibration of Governor as per calibration procedure and norms suitable for DG Set of capacity upto 75 KVA complete all as directed by Engineer-in-charge 3 Job
27 17 All as per SL item No.16 above but DG set of capacity 100 KVA to 125 KVA 3 Job
28 18 All as per SL item No.16 above but DG set of capacity 200 KVA 1 Job
29 19 M&L for Repair and Calibration of turbo super charger suitable for DG set of capcity upto 75 KVA as per calibration procedure, norms and as per manufacturer's guide lines including replacement of turbo supply hoses, discharge hoses, clamps and de-scaling of turbo charger complete all as specified and directed. 1 Job
30 20 All as per SL item No.19 above but DG set of capacity 100 KVA to 125 KVA 1 Job
31 21 All as per SL item No.19 above but DG set of capacity 200 KVA 1 Job
32 22 M&L for repair and calibration of fuel pump & Injectors suitable for DG set of capcity upto 75 KVA as per calibration procedure, norms and as per manufacturer's guide lines including replacement of unserviceable 'O' rings, plungers and cups etc., complete all as specified and directed. 2 Job
33 23 All as per SL item No.22 above but DG set of capacity 100 KVA to 125 KVA 2 Job
34 24 All as per SL item No.22 above but DG set of capacity 200 KVA 1 Job
35 25 M&L for repair and calibration of Self Starter suitable for DG set of capcity upto 75 KVA including rewinding of commutator, replacing carbon brush set, carbon brush holder, king pins holders, armature check nuts, body screws, clutch plate assembly and solenoid etc., as required complete all as specified and as directed by Engr-in-charge. 2 Job
36 26 All as per SL item No.25 above but DG set of capacity 100 KVA to 125 KVA 2 Job
37 27 All as per SL item No.25 above but DG set of capacity 200 KVA 1 Job
38 28 M&L for descaling of radiator suitable for DG set of capcity upto 75 KVA by dismantling the upper and lower tank, cleaning the core pipes and components with cleaning chemicals, arresting the leaking core by brazing/ dummy with lead including cleaning of upper and lower tanks, replacing the upper and lower tank gaskets and required nuts, bolts, painting with one coat of synthetic enamel paint of approved colour, refixing the same including testing complete all as specified and directed. 3 Job
39 29 All as per SL item No.28 above but DG set of capacity 100 KVA to 125 KVA 3 Job
40 30 All as per SL item No.28 above but DG set of capacity 200 KVA 1 Job
41 31 M&L for servicing of alternator of any make suitable for DG set of capcity upto 75 KVA by opening the end cover, cleaning the dust and rust formed over the terminals, cleaning with CTC liquid, checking of diodes, winding, isolating transformer and AVR panel and applying Dr. beck paint for insulation improvement over the strips/ winding and drying till getting sasfactory insulation resistance complete, refixing the covers including testing complete all as specified and directed. 3 Job
42 32 All as per SL item No.31 above but DG set of capacity 100 KVA to 125 KVA 3 Job
43 33 All as per SL item No.31 above but DG set of capacity 200 KVA 1 Job
44 34 Supply only the following spares suitable for DG set of capacity 62.5/75/100 KVA
45 34.01 Valve guide 16 Each
46 34.02 Exhaust valve 16 Each
47 34.03 Intake valve 16 Each
48 34.04 Valve spring 16 Each
49 34.05 Valve lock 30 Each
50 34.06 Valve set 18 Each
51 34.07 Gasket kit 4 Each Set
52 35 Supply only the following spares suitable for DG set of capacity125/200 KVA
53 35.01 Valve guide 16 Each
54 35.02 Exhaust valve 16 Each
55 35.03 Intake valve 16 Each
56 35.04 Valve spring 16 Each
57 35.05 Valve lock 30 Each
58 35.06 Valve set 18 Each
59 35.07 Gasket kit 4 Each Set
60 36 Repair to AMF panel of 30 to 82.5 KVA DG Set, by tracing out the defects and replacing unserviceable parts including control wiring complete all as specified and directed by Engr-in-charge. \nNote: Spares shall be measured and paid separately under relevent items of BOQ and labour element for fixing parts shall be deemed to be included in the quoted rate. 1 Job
61 37 All as per item No. 36 above but AMF panel of 100 to 200 KVA DG Set 1 Job
62 38 Repair to the self starter of capacity 24 Volts connected to DG Sets including replacement of defective winding etc complete all as directed by Engr -in Charge. 3 Job
63 39 All as per Sl. item No. 38 above but of capacity 12 Volts 1 Job
64 40 Repair to Dynamo of capacity 24 Volts connected to DG Sets of any capacity including replacement of defective spare parts and winding complete all as directed by Engr-in-charge. 2 Job
65 41 All as per Sl. item No.40 above but 12 Volts capacity 1 Job
66 42 Surface dressing in soft/loose soil not exceeding 15 cm deep, cutting/ cleaning of branches, bushes/plants/ grass obstructing the pipe line/ valve chambers/ sumps/OHTs and path on either sides of water supply installations area including disposal the material up to a distance not execeding 50 m complete all as specified and directed by Engineer-in-Charge. 5500 Sqm
67 43 Supply and replace on load change over switch 4 pole, 415 Volts, 50 Hz, 400 Amps, in open execution fixing in existing panel including necessary modification in panel complete all as specified and directed. 1 Each
68 44 All as per SL item No.43 above but 200 Amps capacity 1 Each
69 45 Supply and filling of coolant for radiator of DG set of any capacity at various locations complete all as directed 100 Litre
70 46 Supply, fix , testing and commissioning new 12 Volts, 180 AH lead acid Battery including removing existing unserviceable one complete all as directed 8 Each
71 47 Supply, fix, testing and commissioning new 24 Volts, 180 AH lead acid Battery including removing existing unserviceable one complete all as directed 2 Each
72 48 M&L for preparation of old painted surfaces of DG Set of capacity 20 to 40 KVA by scraping / brushing and cleaning with cloth and applying two coats of synthetic enamel paint by spray machine of approved quality and colour to match the existing one complete and lettering the SM and MES Number on the DG Set complete all as directed. 1 Job
73 49 All as per item No. 48 above but of capacity 62.5 to 82.5 KVA 3 Job
74 50 All as per item No. 48 above but of capacity 100 to 200 KVA 3 Job
75 51 All as per item No. 48 above but Diesel engine driven pumpset of capacity 93/105 BHP 3 Job
76 52 Supply and replace copper battery terminals set of 2 complete all as specified and directed.\n 2 Set
77 53 Supply and replace off load change over switch 4 pole, 415 Volts, 50 Hz, 200 Amps in SS enclosure complete all as specified and directed. 2 Each
78 54 Supply and replace MCCB of capacity of 250 Amps, 4 pole 36 KA, 415 Volts with thermo magnetic release, adjustable type complete all as specified and directed. 2 Each
79 55 Supply and replace MCCB of capacity of 125 Amps, 4 pole 25 KA, 415 Volts with thermo magnetic release, adjustable type complete all as specified and directed. 3 Each
80 56 Supply and replace MCCB of capacity of 63 Amps, 4 pole 18 KA, 415 Volts with thermo magnetic release, adjustable type complete all as specified and directed. 3 Each
81 57 Supply, laying XLPE insulated PVC FRLS, screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 3.5 core 185 Sq mm including taking out old un-serviceable cable complete all as specified and directed. 220 RM
82 58 All as per Sl. Item No.57 above but 3.5 Core 95 Sqmm 185 RM
83 59 All as per Sl. Item No.57 above but 3.5 Core 70 Sqmm 180 RM
84 60 All as per Sl. Item No.57 above but 3.5 Core 50 Sqmm 45 RM
85 61 Excavating in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation, laying of cable/pipes etc. n exc 10 sq m on plan and getting out in soft/loose soil complete all as specified and directed. 216 Cum
86 62 Returning filling in, including spreading levelling watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. 175 Cum
87 63 Removing excavated surplus soil to a distance n.exc. 50m distance and depositing where directed at a level n.exc. 1.5 m above the starting point all as specified and directed. 31 Cum
88 64 Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed.\nNote: Punned thickness shall only be measured and paid. 10 Cum
89 65 Supply and laying Sub Class 'B' bricks of old size (23x11x7cm) laid along aligment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-charge 5727 Each
90 66 Supply and replace 80 mm dia GI tubing light grade laid in trenches, fixed to wall/ poles for protection of cables complete all as specified and directed. 12 RM
91 67 Supply and replace 100 mm dia GI tubing light grade laid in trenches, fixed to wall/ poles for protection of cables complete all as specified and directed. 12 RM
92 68 M&L earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point complete all as specified and directed.\nNOTE: (i) The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:2:4, type B1 cover 50 mm thick with 8 mm dia TMT bar @ 140 mm C/C, GI watering pipe 20 mm bore medium grade, funnel, wire mesh including filling with charcoal and salt etc. (ii) GI earth strip upto 7.5 metre shall be deemed to be included in the quoted rate and beyond 7.5 metres shall be measured and paid separately under relavent item. 6 Each Set
93 69 Supply and fix fan belts suitable for DG Sets of capacity 30 KVA Capacity including removing the existing unserviceable one complete all as specified and as directed. 1 Each
94 70 All as per Sl. item No. 67 above but 62.5 to 82.5 KVA Capacity 3 Each
95 71 All as per Sl. item No. 67 above but 100 to 200 KVA Capacity 3 Each
96 72 Supply and replace Contactors 3/4 pole, 100 Amps, 230 Volts complete all as specified and as directed. \nMake: CAT No. 3TS47 of SIEMENS or its equivalent in ABB, BCH, L&T, C&S Electric Ltd, Schneider 3 Each
97 73 Supply and replace Contactors 3/4 pole, 120 Amps, 230 Volts complete all as specified and as directed. \nMake: CAT No. 3TS50 of SIEMENS or its equivalent in ABB, BCH, L&T, C&S Electric Ltd, Schneider 2 Each
98 74 Supply and fixing Digital type Ammeter 0-400 Amps , Selector switch class 1.0 including removing existing unserviceable one complete all as directed 4 Each
99 75 Supply and Fixing Digital type Voltmeter 0-500 Volt and selector switch class 1.0 including removing existing unserviceable one complete all as directed 4 Each
100 76 M&L repair to control panel board of DG sets including replacement of defective unserviceable spare parts of PCB body, connected control wiring, suitable connectors, single phase preventor, MNX type contactors, timers, over load relays & other required accessories complete all as specified and directed by Engineer-in-Charge. 3 Each Job
101 77 Supply and replace MCCB of capacity of 400 Amps, 4 pole 36 KA, 415 Volts with thermo magnetic release, adjustable type complete all as specified and directed. 2 Each
102 78 Supply and replace Remote control digital board with hand set of capacity 7.5/8.5 TR including sensor setting complete all as specified and directed.\nMake: Voltas/ Carrier 1 Each
103 79 Supply and fix 15 mm dia Gun metal gate valve, with iron wheel head, screwed both ends for iron pipe and fixed including cutting the pipe line and taking down old unserviceable valves wherever required complete all as specified and directed. 2 Each
104 80 All as per SL item No.79 above but 20 mm dia 4 Each
105 81 All as per SL item No.79 above but 25 mm dia 5 Each
106 82 All as per SL item No.79 above but 40 mm dia 2 Each
107 83 All as per SL item No.79 above but 50 mm dia 1 Each
108 84 Cutting/ cleaning of branches, bushes/plants/ grass obstructing the pipe line/ valve chambers/ sumps/OHTs and path on either sides of water supply installations area including disposal the material up to a distance not execeding 50 m complete all as specified and directed by Engineer-in-Charge. 2800 Sqm
109 85 Supply and replace Remote control digital board with hand set of capacity 5.5 TR including sensor setting complete all as specified and directed.\nMake: Voltas/ Carrier 1 Each
110 86 Supply and laying GI pipes medium grade 15 mm dia with all fittings and fixtures fixed to walls / under floor complete including taking down old unserviceable one all as specified and directed. 30 RM
111 87 All as per SL item No.86 above but 20 mm dia. 60 RM
112 88 All as per SL item No.86 above but 25 mm dia. 120 RM
113 89 All as per SL item No.86 above but 40 mm dia. 150 RM
114 90 All as per SL item No.86 above but 50 mm dia. 50 RM
115 91 M&L for scraping the old painted steel surface of Carrier Air cooled out door unit AC plants and applying the synthetic enamel paint with spray gun of existing colour code of the plants and applying one coat of white wash to PCC foundation including writing of SM/MES No. complete all as specified and directed by Engr-in-Charge. 4 Each Job
116 92 Material & Labour for chemical servicing of the air cooled condenser indoor & outdoor of 5.5/5.8 TR capacities by dismantling the sheet metal parts, apply the organic compound of scale remover to the air cooled condenser fins & tube area, and flushing through forced method, till removal the complete scale deposited across the fins & tube and cleaning, fixing the sheet metal parts, fan blades, etc. all specified as directed by Engineer-in-Charge. 4 Each Job
117 93 All as per Sl. Item No.92 above but of capacity 7.5/8.5 TR 2 Each Job
118 94 M&L masonary valve chamber of size 750x750x750 mm (internal dimensions) and including necessary excavation and earth work in any type of soil, 100 mm thick PCC 1:4:8 type D2 foundation, brick work in cement mortar 1:6, plastering internal and external surface 15 mm thick in CM 1:4, 50 mm thick PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) coping, 50 x 50 x 6 mm thick MS angle iron, 5 mm thick MS plate cover with locking arrangement, painting exposed steel surfaces with two coats of synthetic enamel paint over a coat of zinc chrome primer including dismantling unserviceable compete all as specified and directed by Engr-in-Charge. 4 Job
119 95 All as per Sl. item No. 94 above but of size 1000x1000x1000 mm (internal dimensions) 2 Job
120 96 M&L for cleaning of Over Head Tank of 0.50 lakhs gallons capacity by cleaning out the accumulated water in the bottom and removing the complete silt from the tank and depositing and levelling as directed and cleaning with the bleaching powder, after scrapping the walls and bottom of the tank by using wire brush completely without disturbing the water supply to the area , and applying one coat of white wash inside OH tank and writing details like Cleaning/ due date/ tank capacity with synthetic enamel paint on bottom wall complete all as directed . 1 Job
121 97 Material and labour for taking down unserviceable burnt compressor, Supply and fix new compressor of existing unit make suitable for 7.5/8.5/11 TR air cooled ductable package conditioner/ Package unit and rectify the control wiring defects if any, connecting back all controls and refrigerant piping after necessary modification as required for system, pressure testing with nitrogen gas under constant pressure of 300 PSI Kg/sq.cm for minimum 24 hours vacuumising, gas charging, commissioning and checking the performance of the system all as directed by the Engineer-in-Charge. 1 Each Job
122 98 Supply and replace V-belt suitable to 7.5 TR indoor blower motor complete all as specified and directed\nMake: Fenner/Yule 2 Each
123 99 Supply and replace high pressure brass float valve with PVC ball suitable for fixing to 25 mm dia GI pipe complete all as specified and directed.\n 1 Each
124 100 Supply and replace big cox brass gate valve 15 mm dia complete all as specified and directed.\n 8 Each
125 101 Supply and replace the following spares
126 101.01 Contactor 3/4P type MNX-25/32, 230 Volts 50 HZ 4 Each
127 101.02 Over load relay type MN-2, 9-15 Amps including lugs, nuts and bolts. 3 Each
128 101.03 Single phase preventor having feature of phase reverse and single phasing range of EC2-22A auxillary supply 230 Volts, 50 Hz special 5 Seconds\nMake: Softhard/ minilac\n 2 Each
129 102 M&L for disconnecting motor of 02 HP capacity from the existing place (AHU / chiller / condenser unit / cooling tower motor etc.,) and including rewinding the motor with existing gauge super enamelled copper conductor, varnishing and drying, replacement of worn-out bearings (DE& NDE), bush connectors, terminal plate and refixing in original position, connecting cable through terminal block, preparation and painting exposed surfaces with one coat of synthetic enamel paint of existing colour code, testing and commissioning complete all as specified and directed. 3 Each Job
130 103 All as per Sl. Item No.3 above but motor of capacity 3 to 5 HP 2 Each Job
131 104 Supply and replace MCCB of capacity of 160 Amps, 3/4 pole 25 KA, 415 Volts with thermo magnetic release, adjustable type complete all as specified and directed. 1 Each
132 105 Supply and replace MCCB of capacity of 63 Amps, 3 pole 18 KA, 415 Volts with thermo magnetic release, adjustable type complete all as specified and directed. 2 Each
133 106 Supply and replace MCCB of capacity of 100 Amps, 3 pole 18 KA, 415 Volts with thermo magnetic release, adjustable type complete all as specified and directed. 1 Each
134 107 M&L repair to control panel board of CQAE, including replacement of defective unserviceable spare parts of PCB body, connected control wiring, suitable connectors, single phase preventor, MNX type contactors, timers, over load relays & other required accessories complete all as specified and directed by Engineer-in-Charge. 1 Each Job
135 108 Excavating in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation, laying of cable/pipes etc. n exc 10 sq m on plan and getting out in hard/dense soil complete all as specified and directed. 1 Cum
136 109 Material and labour for existing run lead joint for spigot and socket pipes (CI/DI) and fittings of size 100 mm bore pipe complete all as specified and directed by Engr-in-Charge. 5 Each
137 110 All as per SL. Item No.109 above but 150 mm dia 6 Each
138 111 Supply and laying DI K9 water supply pipe lines of size 150 mm bore including taking down old DI water mains with spigot and socket ends and lead joints and recovering lead joints complete all as specified and directed.\nNote:- Earth work will be measured and paid separately. 33 RM
139 112 All as per SL. Item No.111 above but 100 mm dia pipe 28 RM
140 113 Supply and replace Hard drawn copper pipe of size 7/8\" of 18 guage for indoor to outdoor unit in magazine area AC Plant including all necessary connections complete all as directed. 20 RM
141 114 Supply and replace Hard drawn copper pipe of size 5/8\" of 18 guage for indoor to outdoor unit in magazine area AC Plant including all necessary connections complete all as directed. 20 RM
142 115 Supply & replacement of water level indicator, 36\" dia as per IS and including numbering with radium stickering, heavy duty float, counter weight, heavy duty driving gear nylon wire fitted in all in GI housing, cutting the RCC slab of UG sump/ OHT (of any height) and making good the slab, painting the exposed surface with two coats of synthetic enamel over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge. \nNote: Make of water level indicator shall be got approved by GE before procurement. 1 Each
143 116 Supply and replace 150 mm bore CI sluice valves PN 1.6 (raising type) conforming to IS 14846 flanged end with iron wheel head and stainless steel spindle flanged joints including necessary nuts, bolts, and washers etc., complete all as specified and directed. 1 Each
144 117 All as per SL item No.116 above but of size 100 mm dia 1 Each
145 118 All as per SL item No.116 above but of size 80 mm dia 1 Each
146 119 Supply and replace CI specials such as bends (any type, radius and angle) tapers any type, straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch, \"Y\" junction, double branch, cross (all sockets or sockets and spigot) collars, caps and plugs upto 150 mm bore complete all as specified and directed. 60 KG
147 120 Supply and replace DI specials such as bends (any type, radius and angle) tapers any type, straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch, \"Y\" junction, double branch, cross (all sockets or sockets and spigot) collars, caps and plugs upto 200 mm bore. 60 KG
148 121 Disconnecting the delivery pipe line and electric connections of submersible pump set of capacity of 5 HP and lifting and removing it from its position along with pipes and fittings carefully with the help of required T&P and transporting the same to the work shop for repair / servicing/ rewinding with existing gauge super enamelled copper conductor, varnishing and drying and lowering and refixing the same in its original position including connecting up of water and electric connections including testing and commissioning complete all as specified. 1 Each Job

AI Tender Summary

OUR REF NO 21267685
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 22-08-2019
Authority
Authority Name Military Engineer Services
Work Description Repairs/ Maintenance Of Dg Sets , Amf Panels And Allied E/M Works And Repairs/ Maintenance Of Water Supply Pipe Lines Submersible Pump Sets Including Misc E/M Works At Cqae Etc Under Age E/M No1 Of Ge ( Utility-Ii ) Visakhapatnam , M&L For Maintenance Of Diesel Engine Connected With Dg Set 200 Kva For B Check As Per Recomendation Of Manufacturers Instructions Including Replacement Of Filters , Accessories Like Fuel Filter With Ring , Air Filter And Ring , Super Bypass Filter Element , O Ring Seal , Oil Filter And Engine Oil Complete All As Specified And Directed By Engr-In-Charge . , All As Per Sl Item No . 1 Above But Dg Set 125 Kva , All As Per Sl Item No . 1 Above But Dg Set 100 Kva , All As Per Sl Item No . 1 Above But Dg Set 62 . 5 Kva , All As Per Sl Item No . 1 Above But Dg Set 30 Kva , M&L For Replacement Of Air Cleaner Filter To 200 Kva Dg Set Matching With The Existing One All As Per Manufacturer Recommendation Complete All As Specified And Directed By Engr-In-Charge . , All As Per Sl Item No . 6 Above But Dg Set 125 Kva , All As Per Sl Item No . 6 Above But Dg Set 100 Kva , All As Per Sl Item No . 6 Above But Dg Set 62 . 5 Kva , All As Per Sl Item No . 6 Above But Dg Set 30 Kva , Supply And Filling Engine Oil 15 W 40 Grade Castrol Crb For Topping Up ( Including Draining Out Old Oil From Gen Set ) Complete All As Specified And Directed . Make : Servo/ Valvoline/ Hpcl , M&L For Repair Of Diesel Engine Of Capacity Upto 75 Kva By Dismantling The Sub-Assemblies Such As Fuel Pump , Fuel Injection , Governor , Turbo-Charger , Radiator , Oil Cooler , Engine Heads , Rocker Arms , Self Starter , Dynamo-Engine Wiring , Terminal Contacts And Safety Controls Etc . , Including Replacement Of Spare Parts As Required And Re-Assembling The Sub-Assemblies After Carrying Out Necessary Repairs Including Testing And Commissioning Complete All As Directed By Engineer-In-Charge . Notes: 1 . Spare Required Shall Be Measured And Paid Separately Under Relevant Items Of Boq . 2 . Repairs And Calibration Of Sub-Assemblies Shall Be Measured And Paid Separately Under Relevant Items Of Boq . , All As Per Sl Item No . 12 Above But Dg Set Of Capacity 100 To 125 Kva , All As Per Sl Item No . 12 Above But Dg Set Of Capacity 200 Kva , Supply Only The Following Spares In The Engine Of Make Kirloskar/Cummins , Radiator Fan Guard , Dynamo Belt , Bend Hose , Radiator Connection Hoses , Radiator Connection Ms Pipes 2 1/4Inner Dia Length 1 Feet , Radiator Hose Clamps , Top Cover Gaskets 6 Nos , Lubricant Oil Drain Hose , Radiator Mounting Pads , Lubricant Oil Filter , M&L For Repair And Calibration Of Governor As Per Calibration Procedure And Norms Suitable For Dg Set Of Capacity Upto 75 Kva Complete All As Directed By Engineer-In-Charge , All As Per Sl Item No . 16 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 16 Above But Dg Set Of Capacity 200 Kva , M&L For Repair And Calibration Of Turbo Super Charger Suitable For Dg Set Of Capcity Upto 75 Kva As Per Calibration Procedure , Norms And As Per Manufacturers Guide Lines Including Replacement Of Turbo Supply Hoses , Discharge Hoses , Clamps And De-Scaling Of Turbo Charger Complete All As Specified And Directed . , All As Per Sl Item No . 19 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 19 Above But Dg Set Of Capacity 200 Kva , M&L For Repair And Calibration Of Fuel Pump & Injectors Suitable For Dg Set Of Capcity Upto 75 Kva As Per Calibration Procedure , Norms And As Per Manufacturers Guide Lines Including Replacement Of Unserviceable O Rings , Plungers And Cups Etc . , Complete All As Specified And Directed . , All As Per Sl Item No . 22 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 22 Above But Dg Set Of Capacity 200 Kva , M&L For Repair And Calibration Of Self Starter Suitable For Dg Set Of Capcity Upto 75 Kva Including Rewinding Of Commutator , Replacing Carbon Brush Set , Carbon Brush Holder , King Pins Holders , Armature Check Nuts , Body Screws , Clutch Plate Assembly And Solenoid Etc . , As Required Complete All As Specified And As Directed By Engr-In-Charge . , All As Per Sl Item No . 25 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 25 Above But Dg Set Of Capacity 200 Kva , M&L For Descaling Of Radiator Suitable For Dg Set Of Capcity Upto 75 Kva By Dismantling The Upper And Lower Tank , Cleaning The Core Pipes And Components With Cleaning Chemicals , Arresting The Leaking Core By Brazing/ Dummy With Lead Including Cleaning Of Upper And Lower Tanks , Replacing The Upper And Lower Tank Gaskets And Required Nuts , Bolts , Painting With One Coat Of Synthetic Enamel Paint Of Approved Colour , Refixing The Same Including Testing Complete All As Specified And Directed . , All As Per Sl Item No . 28 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 28 Above But Dg Set Of Capacity 200 Kva , M&L For Servicing Of Alternator Of Any Make Suitable For Dg Set Of Capcity Upto 75 Kva By Opening The End Cover , Cleaning The Dust And Rust Formed Over The Terminals , Cleaning With Ctc Liquid , Checking Of Diodes , Winding , Isolating Transformer And Avr Panel And Applying Dr . Beck Paint For Insulation Improvement Over The Strips/ Winding And Drying Till Getting Sasfactory Insulation Resistance Complete , Refixing The Covers Including Testing Complete All As Specified And Directed . , All As Per Sl Item No . 31 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 31 Above But Dg Set Of Capacity 200 Kva , Supply Only The Following Spares Suitable For Dg Set Of Capacity 62 . 5/75/100 Kva , Valve Guide , Exhaust Valve , Intake Valve , Valve Spring , Valve Lock , Valve Set , Gasket Kit , Supply Only The Following Spares Suitable For Dg Set Of Capacity125/200 Kva , Valve Guide , Exhaust Valve , Intake Valve , Valve Spring , Valve Lock , Valve Set , Gasket Kit , Repair To Amf Panel Of 30 To 82 . 5 Kva Dg Set , By Tracing Out The Defects And Replacing Unserviceable Parts Including Control Wiring Complete All As Specified And Directed By Engr-In-Charge . Note: Spares Shall Be Measured And Paid Separately Under Relevent Items Of Boq And Labour Element For Fixing Parts Shall Be Deemed To Be Included In The Quoted Rate . , All As Per Item No . 36 Above But Amf Panel Of 100 To 200 Kva Dg Set , Repair To The Self Starter Of Capacity 24 Volts Connected To Dg Sets Including Replacement Of Defective Winding Etc Complete All As Directed By Engr -In Charge . , All As Per Sl . Item No . 38 Above But Of Capacity 12 Volts , Repair To Dynamo Of Capacity 24 Volts Connected To Dg Sets Of Any Capacity Including Replacement Of Defective Spare Parts And Winding Complete All As Directed By Engr-In-Charge . , All As Per Sl . Item No . 40 Above But 12 Volts Capacity , Surface Dressing In Soft/Loose Soil Not Exceeding 15 Cm Deep , Cutting/ Cleaning Of Branches , Bushes/Plants/ Grass Obstructing The Pipe Line/ Valve Chambers/ Sumps/Ohts And Path On Either Sides Of Water Supply Installations Area Including Disposal The Material Up To A Distance Not Execeding 50 M Complete All As Specified And Directed By Engineer-In-Charge . , Supply And Replace On Load Change Over Switch 4 Pole , 415 Volts , 50 Hz , 400 Amps , In Open Execution Fixing In Existing Panel Including Necessary Modification In Panel Complete All As Specified And Directed . , All As Per Sl Item No . 43 Above But 200 Amps Capacity , Supply And Filling Of Coolant For Radiator Of Dg Set Of Any Capacity At Various Locations Complete All As Directed , Supply , Fix , Testing And Commissioning New 12 Volts , 180 Ah Lead Acid Battery Including Removing Existing Unserviceable One Complete All As Directed , Supply , Fix , Testing And Commissioning New 24 Volts , 180 Ah Lead Acid Battery Including Removing Existing Unserviceable O
Basic Detail
Tender No 8636
Bidding Type Tender
Location
City GE UTILITY II VISAKHAPATNAM
State Andhra Pradesh
Key Dates
Publish Date 02 Aug 2019
Submission Date 22 Aug 2019
Open Date 23 Aug 2019
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Not Available
Document List
83D8893A-3933-4E30-B986-10C1E4A51F57.html
Tendernotice_1.pdf
BOQ_305805.xls
TENDERDOCUMENTS8636.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 02, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 22, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 23, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

83D8893A-3933-4E30-B986-10C1E4A51F57.html

pdf

Tendernotice_1.pdf

xls

BOQ_305805.xls

pdf

TENDERDOCUMENTS8636.pdf

TenderDetail
Loading tenders