Repairs/ Maintenance Of Dg Sets , Amf Panels And Allied E/M Works And Repairs/ Maintenance Of Water Supply Pipe Lines Submersible Pump Sets Including Misc E/M Works At Cqae Etc Under Age E/M No1 Of Ge ( Utility-Ii ) Visakhapatnam
Tender Overview
Project Description
Repairs/ Maintenance Of Dg Sets , Amf Panels And Allied E/M Works And Repairs/ Maintenance Of Water Supply Pipe Lines Submersible Pump Sets Including Misc E/M Works At Cqae Etc Under Age E/M No1 Of Ge ( Utility-Ii ) Visakhapatnam , M&L For Maintenance Of Diesel Engine Connected With Dg Set 200 Kva For B Check As Per Recomendation Of Manufacturers Instructions Including Replacement Of Filters , Accessories Like Fuel Filter With Ring , Air Filter And Ring , Super Bypass Filter Element , O Ring Seal , Oil Filter And Engine Oil Complete All As Specified And Directed By Engr-In-Charge . , All As Per Sl Item No . 1 Above But Dg Set 125 Kva , All As Per Sl Item No . 1 Above But Dg Set 100 Kva , All As Per Sl Item No . 1 Above But Dg Set 62 . 5 Kva , All As Per Sl Item No . 1 Above But Dg Set 30 Kva , M&L For Replacement Of Air Cleaner Filter To 200 Kva Dg Set Matching With The Existing One All As Per Manufacturer Recommendation Complete All As Specified And Directed By Engr-In-Charge . , All As Per Sl Item No . 6 Above But Dg Set 125 Kva , All As Per Sl Item No . 6 Above But Dg Set 100 Kva , All As Per Sl Item No . 6 Above But Dg Set 62 . 5 Kva , All As Per Sl Item No . 6 Above But Dg Set 30 Kva , Supply And Filling Engine Oil 15 W 40 Grade Castrol Crb For Topping Up ( Including Draining Out Old Oil From Gen Set ) Complete All As Specified And Directed . Make : Servo/ Valvoline/ Hpcl , M&L For Repair Of Diesel Engine Of Capacity Upto 75 Kva By Dismantling The Sub-Assemblies Such As Fuel Pump , Fuel Injection , Governor , Turbo-Charger , Radiator , Oil Cooler , Engine Heads , Rocker Arms , Self Starter , Dynamo-Engine Wiring , Terminal Contacts And Safety Controls Etc . , Including Replacement Of Spare Parts As Required And Re-Assembling The Sub-Assemblies After Carrying Out Necessary Repairs Including Testing And Commissioning Complete All As Directed By Engineer-In-Charge . Notes: 1 . Spare Required Shall Be Measured And Paid Separately Under Relevant Items Of Boq . 2 . Repairs And Calibration Of Sub-Assemblies Shall Be Measured And Paid Separately Under Relevant Items Of Boq . , All As Per Sl Item No . 12 Above But Dg Set Of Capacity 100 To 125 Kva , All As Per Sl Item No . 12 Above But Dg Set Of Capacity 200 Kva , Supply Only The Following Spares In The Engine Of Make Kirloskar/Cummins , Radiator Fan Guard , Dynamo Belt , Bend Hose , Radiator Connection Hoses , Radiator Connection Ms Pipes 2 1/4Inner Dia Length 1 Feet , Radiator Hose Clamps , Top Cover Gaskets 6 Nos , Lubricant Oil Drain Hose , Radiator Mounting Pads , Lubricant Oil Filter , M&L For Repair And Calibration Of Governor As Per Calibration Procedure And Norms Suitable For Dg Set Of Capacity Upto 75 Kva Complete All As Directed By Engineer-In-Charge , All As Per Sl Item No . 16 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 16 Above But Dg Set Of Capacity 200 Kva , M&L For Repair And Calibration Of Turbo Super Charger Suitable For Dg Set Of Capcity Upto 75 Kva As Per Calibration Procedure , Norms And As Per Manufacturers Guide Lines Including Replacement Of Turbo Supply Hoses , Discharge Hoses , Clamps And De-Scaling Of Turbo Charger Complete All As Specified And Directed . , All As Per Sl Item No . 19 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 19 Above But Dg Set Of Capacity 200 Kva , M&L For Repair And Calibration Of Fuel Pump & Injectors Suitable For Dg Set Of Capcity Upto 75 Kva As Per Calibration Procedure , Norms And As Per Manufacturers Guide Lines Including Replacement Of Unserviceable O Rings , Plungers And Cups Etc . , Complete All As Specified And Directed . , All As Per Sl Item No . 22 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 22 Above But Dg Set Of Capacity 200 Kva , M&L For Repair And Calibration Of Self Starter Suitable For Dg Set Of Capcity Upto 75 Kva Including Rewinding Of Commutator , Replacing Carbon Brush Set , Carbon Brush Holder , King Pins Holders , Armature Check Nuts , Body Screws , Clutch Plate Assembly And Solenoid Etc . , As Required Complete All As Specified And As Directed By Engr-In-Charge . , All As Per Sl Item No . 25 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 25 Above But Dg Set Of Capacity 200 Kva , M&L For Descaling Of Radiator Suitable For Dg Set Of Capcity Upto 75 Kva By Dismantling The Upper And Lower Tank , Cleaning The Core Pipes And Components With Cleaning Chemicals , Arresting The Leaking Core By Brazing/ Dummy With Lead Including Cleaning Of Upper And Lower Tanks , Replacing The Upper And Lower Tank Gaskets And Required Nuts , Bolts , Painting With One Coat Of Synthetic Enamel Paint Of Approved Colour , Refixing The Same Including Testing Complete All As Specified And Directed . , All As Per Sl Item No . 28 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 28 Above But Dg Set Of Capacity 200 Kva , M&L For Servicing Of Alternator Of Any Make Suitable For Dg Set Of Capcity Upto 75 Kva By Opening The End Cover , Cleaning The Dust And Rust Formed Over The Terminals , Cleaning With Ctc Liquid , Checking Of Diodes , Winding , Isolating Transformer And Avr Panel And Applying Dr . Beck Paint For Insulation Improvement Over The Strips/ Winding And Drying Till Getting Sasfactory Insulation Resistance Complete , Refixing The Covers Including Testing Complete All As Specified And Directed . , All As Per Sl Item No . 31 Above But Dg Set Of Capacity 100 Kva To 125 Kva , All As Per Sl Item No . 31 Above But Dg Set Of Capacity 200 Kva , Supply Only The Following Spares Suitable For Dg Set Of Capacity 62 . 5/75/100 Kva , Valve Guide , Exhaust Valve , Intake Valve , Valve Spring , Valve Lock , Valve Set , Gasket Kit , Supply Only The Following Spares Suitable For Dg Set Of Capacity125/200 Kva , Valve Guide , Exhaust Valve , Intake Valve , Valve Spring , Valve Lock , Valve Set , Gasket Kit , Repair To Amf Panel Of 30 To 82 . 5 Kva Dg Set , By Tracing Out The Defects And Replacing Unserviceable Parts Including Control Wiring Complete All As Specified And Directed By Engr-In-Charge . Note: Spares Shall Be Measured And Paid Separately Under Relevent Items Of Boq And Labour Element For Fixing Parts Shall Be Deemed To Be Included In The Quoted Rate . , All As Per Item No . 36 Above But Amf Panel Of 100 To 200 Kva Dg Set , Repair To The Self Starter Of Capacity 24 Volts Connected To Dg Sets Including Replacement Of Defective Winding Etc Complete All As Directed By Engr -In Charge . , All As Per Sl . Item No . 38 Above But Of Capacity 12 Volts , Repair To Dynamo Of Capacity 24 Volts Connected To Dg Sets Of Any Capacity Including Replacement Of Defective Spare Parts And Winding Complete All As Directed By Engr-In-Charge . , All As Per Sl . Item No . 40 Above But 12 Volts Capacity , Surface Dressing In Soft/Loose Soil Not Exceeding 15 Cm Deep , Cutting/ Cleaning Of Branches , Bushes/Plants/ Grass Obstructing The Pipe Line/ Valve Chambers/ Sumps/Ohts And Path On Either Sides Of Water Supply Installations Area Including Disposal The Material Up To A Distance Not Execeding 50 M Complete All As Specified And Directed By Engineer-In-Charge . , Supply And Replace On Load Change Over Switch 4 Pole , 415 Volts , 50 Hz , 400 Amps , In Open Execution Fixing In Existing Panel Including Necessary Modification In Panel Complete All As Specified And Directed . , All As Per Sl Item No . 43 Above But 200 Amps Capacity , Supply And Filling Of Coolant For Radiator Of Dg Set Of Any Capacity At Various Locations Complete All As Directed , Supply , Fix , Testing And Commissioning New 12 Volts , 180 Ah Lead Acid Battery Including Removing Existing Unserviceable One Complete All As Directed , Supply , Fix , Testing And Commissioning New 24 Volts , 180 Ah Lead Acid Battery Including Removing Existing Unserviceable O
BOQ
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
|---|---|---|---|---|---|
| 1 | 1 | M&L for maintenance of diesel Engine connected with DG Set 200 KVA for 'B' check as per recomendation of manufacturers instructions including replacement of filters, accessories like fuel filter with ring, Air filter and ring , super bypass filter element , 'O' Ring seal, Oil filter and engine Oil complete all as specified and directed by Engr-in-charge. | 1 | Job | |
| 2 | 2 | All as per SL item No.1 above but DG set 125 KVA | 2 | Job | |
| 3 | 3 | All as per SL item No.1 above but DG set 100 KVA | 3 | Job | |
| 4 | 4 | All as per SL item No.1 above but DG set 62.5 KVA | 3 | Job | |
| 5 | 5 | All as per SL item No.1 above but DG set 30 KVA | 1 | Job | |
| 6 | 6 | M&L for replacement of air cleaner filter to 200 KVA DG set matching with the existing one all as per manufacturer recommendation complete all as specified and directed by Engr-in-charge. | 1 | Job | |
| 7 | 7 | All as per SL item No.6 above but DG set 125 KVA | 2 | Job | |
| 8 | 8 | All as per SL item No.6 above but DG set 100 KVA | 3 | Job | |
| 9 | 9 | All as per SL item No.6 above but DG set 62.5 KVA | 3 | Job | |
| 10 | 10 | All as per SL item No.6 above but DG set 30 KVA | 1 | Job | |
| 11 | 11 | Supply and filling Engine oil 15 W 40 Grade Castrol CRB for topping up (including draining out old oil from Gen Set) complete all as specified and directed.\nMake : Servo/ Valvoline/ HPCL | 200 | Litre | |
| 12 | 12 | M&L for repair of Diesel Engine of capacity upto 75 KVA by dismantling the Sub-assemblies such as fuel pump, fuel injection, Governor, turbo-charger, radiator, oil cooler, engine heads, rocker arms, self starter, dynamo-engine wiring, terminal contacts and safety controls etc., including replacement of spare parts as required and re-assembling the sub-assemblies after carrying out necessary repairs including testing and commissioning complete all as directed by Engineer-in-charge.\nNotes: 1. Spare required shall be measured and paid separately under relevant items of BOQ.\n2. Repairs and calibration of Sub-assemblies shall be measured and paid separately under relevant items of BOQ. | 3 | Job | |
| 13 | 13 | All as per SL item No.12 above but DG set of capacity 100 to 125 KVA | 3 | Job | |
| 14 | 14 | All as per SL item No.12 above but DG set of capacity 200 KVA | 1 | Job | |
| 15 | 15 | Supply only the following spares in the Engine of Make Kirloskar/Cummins | |||
| 16 | 15.01 | Radiator fan guard | 6 | Each | |
| 17 | 15.02 | Dynamo Belt | 6 | Each | |
| 18 | 15.03 | Bend hose | 6 | Each | |
| 19 | 15.04 | Radiator Connection hoses | 6 | Each | |
| 20 | 15.05 | Radiator Connection MS Pipes 2 1/4\"inner dia length 1 feet | 6 | Each | |
| 21 | 15.06 | Radiator hose clamps | 6 | Set | |
| 22 | 15.07 | Top cover gaskets 6 NOS | 6 | Set | |
| 23 | 15.08 | Lubricant oil drain hose | 6 | Set | |
| 24 | 15.09 | Radiator mounting pads | 6 | Each | |
| 25 | 15.1 | Lubricant oil filter | 6 | Each | |
| 26 | 16 | M&L for Repair and Calibration of Governor as per calibration procedure and norms suitable for DG Set of capacity upto 75 KVA complete all as directed by Engineer-in-charge | 3 | Job | |
| 27 | 17 | All as per SL item No.16 above but DG set of capacity 100 KVA to 125 KVA | 3 | Job | |
| 28 | 18 | All as per SL item No.16 above but DG set of capacity 200 KVA | 1 | Job | |
| 29 | 19 | M&L for Repair and Calibration of turbo super charger suitable for DG set of capcity upto 75 KVA as per calibration procedure, norms and as per manufacturer's guide lines including replacement of turbo supply hoses, discharge hoses, clamps and de-scaling of turbo charger complete all as specified and directed. | 1 | Job | |
| 30 | 20 | All as per SL item No.19 above but DG set of capacity 100 KVA to 125 KVA | 1 | Job | |
| 31 | 21 | All as per SL item No.19 above but DG set of capacity 200 KVA | 1 | Job | |
| 32 | 22 | M&L for repair and calibration of fuel pump & Injectors suitable for DG set of capcity upto 75 KVA as per calibration procedure, norms and as per manufacturer's guide lines including replacement of unserviceable 'O' rings, plungers and cups etc., complete all as specified and directed. | 2 | Job | |
| 33 | 23 | All as per SL item No.22 above but DG set of capacity 100 KVA to 125 KVA | 2 | Job | |
| 34 | 24 | All as per SL item No.22 above but DG set of capacity 200 KVA | 1 | Job | |
| 35 | 25 | M&L for repair and calibration of Self Starter suitable for DG set of capcity upto 75 KVA including rewinding of commutator, replacing carbon brush set, carbon brush holder, king pins holders, armature check nuts, body screws, clutch plate assembly and solenoid etc., as required complete all as specified and as directed by Engr-in-charge. | 2 | Job | |
| 36 | 26 | All as per SL item No.25 above but DG set of capacity 100 KVA to 125 KVA | 2 | Job | |
| 37 | 27 | All as per SL item No.25 above but DG set of capacity 200 KVA | 1 | Job | |
| 38 | 28 | M&L for descaling of radiator suitable for DG set of capcity upto 75 KVA by dismantling the upper and lower tank, cleaning the core pipes and components with cleaning chemicals, arresting the leaking core by brazing/ dummy with lead including cleaning of upper and lower tanks, replacing the upper and lower tank gaskets and required nuts, bolts, painting with one coat of synthetic enamel paint of approved colour, refixing the same including testing complete all as specified and directed. | 3 | Job | |
| 39 | 29 | All as per SL item No.28 above but DG set of capacity 100 KVA to 125 KVA | 3 | Job | |
| 40 | 30 | All as per SL item No.28 above but DG set of capacity 200 KVA | 1 | Job | |
| 41 | 31 | M&L for servicing of alternator of any make suitable for DG set of capcity upto 75 KVA by opening the end cover, cleaning the dust and rust formed over the terminals, cleaning with CTC liquid, checking of diodes, winding, isolating transformer and AVR panel and applying Dr. beck paint for insulation improvement over the strips/ winding and drying till getting sasfactory insulation resistance complete, refixing the covers including testing complete all as specified and directed. | 3 | Job | |
| 42 | 32 | All as per SL item No.31 above but DG set of capacity 100 KVA to 125 KVA | 3 | Job | |
| 43 | 33 | All as per SL item No.31 above but DG set of capacity 200 KVA | 1 | Job | |
| 44 | 34 | Supply only the following spares suitable for DG set of capacity 62.5/75/100 KVA | |||
| 45 | 34.01 | Valve guide | 16 | Each | |
| 46 | 34.02 | Exhaust valve | 16 | Each | |
| 47 | 34.03 | Intake valve | 16 | Each | |
| 48 | 34.04 | Valve spring | 16 | Each | |
| 49 | 34.05 | Valve lock | 30 | Each | |
| 50 | 34.06 | Valve set | 18 | Each | |
| 51 | 34.07 | Gasket kit | 4 | Each Set | |
| 52 | 35 | Supply only the following spares suitable for DG set of capacity125/200 KVA | |||
| 53 | 35.01 | Valve guide | 16 | Each | |
| 54 | 35.02 | Exhaust valve | 16 | Each | |
| 55 | 35.03 | Intake valve | 16 | Each | |
| 56 | 35.04 | Valve spring | 16 | Each | |
| 57 | 35.05 | Valve lock | 30 | Each | |
| 58 | 35.06 | Valve set | 18 | Each | |
| 59 | 35.07 | Gasket kit | 4 | Each Set | |
| 60 | 36 | Repair to AMF panel of 30 to 82.5 KVA DG Set, by tracing out the defects and replacing unserviceable parts including control wiring complete all as specified and directed by Engr-in-charge. \nNote: Spares shall be measured and paid separately under relevent items of BOQ and labour element for fixing parts shall be deemed to be included in the quoted rate. | 1 | Job | |
| 61 | 37 | All as per item No. 36 above but AMF panel of 100 to 200 KVA DG Set | 1 | Job | |
| 62 | 38 | Repair to the self starter of capacity 24 Volts connected to DG Sets including replacement of defective winding etc complete all as directed by Engr -in Charge. | 3 | Job | |
| 63 | 39 | All as per Sl. item No. 38 above but of capacity 12 Volts | 1 | Job | |
| 64 | 40 | Repair to Dynamo of capacity 24 Volts connected to DG Sets of any capacity including replacement of defective spare parts and winding complete all as directed by Engr-in-charge. | 2 | Job | |
| 65 | 41 | All as per Sl. item No.40 above but 12 Volts capacity | 1 | Job | |
| 66 | 42 | Surface dressing in soft/loose soil not exceeding 15 cm deep, cutting/ cleaning of branches, bushes/plants/ grass obstructing the pipe line/ valve chambers/ sumps/OHTs and path on either sides of water supply installations area including disposal the material up to a distance not execeding 50 m complete all as specified and directed by Engineer-in-Charge. | 5500 | Sqm | |
| 67 | 43 | Supply and replace on load change over switch 4 pole, 415 Volts, 50 Hz, 400 Amps, in open execution fixing in existing panel including necessary modification in panel complete all as specified and directed. | 1 | Each | |
| 68 | 44 | All as per SL item No.43 above but 200 Amps capacity | 1 | Each | |
| 69 | 45 | Supply and filling of coolant for radiator of DG set of any capacity at various locations complete all as directed | 100 | Litre | |
| 70 | 46 | Supply, fix , testing and commissioning new 12 Volts, 180 AH lead acid Battery including removing existing unserviceable one complete all as directed | 8 | Each | |
| 71 | 47 | Supply, fix, testing and commissioning new 24 Volts, 180 AH lead acid Battery including removing existing unserviceable one complete all as directed | 2 | Each | |
| 72 | 48 | M&L for preparation of old painted surfaces of DG Set of capacity 20 to 40 KVA by scraping / brushing and cleaning with cloth and applying two coats of synthetic enamel paint by spray machine of approved quality and colour to match the existing one complete and lettering the SM and MES Number on the DG Set complete all as directed. | 1 | Job | |
| 73 | 49 | All as per item No. 48 above but of capacity 62.5 to 82.5 KVA | 3 | Job | |
| 74 | 50 | All as per item No. 48 above but of capacity 100 to 200 KVA | 3 | Job | |
| 75 | 51 | All as per item No. 48 above but Diesel engine driven pumpset of capacity 93/105 BHP | 3 | Job | |
| 76 | 52 | Supply and replace copper battery terminals set of 2 complete all as specified and directed.\n | 2 | Set | |
| 77 | 53 | Supply and replace off load change over switch 4 pole, 415 Volts, 50 Hz, 200 Amps in SS enclosure complete all as specified and directed. | 2 | Each | |
| 78 | 54 | Supply and replace MCCB of capacity of 250 Amps, 4 pole 36 KA, 415 Volts with thermo magnetic release, adjustable type complete all as specified and directed. | 2 | Each | |
| 79 | 55 | Supply and replace MCCB of capacity of 125 Amps, 4 pole 25 KA, 415 Volts with thermo magnetic release, adjustable type complete all as specified and directed. | 3 | Each | |
| 80 | 56 | Supply and replace MCCB of capacity of 63 Amps, 4 pole 18 KA, 415 Volts with thermo magnetic release, adjustable type complete all as specified and directed. | 3 | Each | |
| 81 | 57 | Supply, laying XLPE insulated PVC FRLS, screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 3.5 core 185 Sq mm including taking out old un-serviceable cable complete all as specified and directed. | 220 | RM | |
| 82 | 58 | All as per Sl. Item No.57 above but 3.5 Core 95 Sqmm | 185 | RM | |
| 83 | 59 | All as per Sl. Item No.57 above but 3.5 Core 70 Sqmm | 180 | RM | |
| 84 | 60 | All as per Sl. Item No.57 above but 3.5 Core 50 Sqmm | 45 | RM | |
| 85 | 61 | Excavating in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation, laying of cable/pipes etc. n exc 10 sq m on plan and getting out in soft/loose soil complete all as specified and directed. | 216 | Cum | |
| 86 | 62 | Returning filling in, including spreading levelling watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. | 175 | Cum | |
| 87 | 63 | Removing excavated surplus soil to a distance n.exc. 50m distance and depositing where directed at a level n.exc. 1.5 m above the starting point all as specified and directed. | 31 | Cum | |
| 88 | 64 | Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed.\nNote: Punned thickness shall only be measured and paid. | 10 | Cum | |
| 89 | 65 | Supply and laying Sub Class 'B' bricks of old size (23x11x7cm) laid along aligment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-charge | 5727 | Each | |
| 90 | 66 | Supply and replace 80 mm dia GI tubing light grade laid in trenches, fixed to wall/ poles for protection of cables complete all as specified and directed. | 12 | RM | |
| 91 | 67 | Supply and replace 100 mm dia GI tubing light grade laid in trenches, fixed to wall/ poles for protection of cables complete all as specified and directed. | 12 | RM | |
| 92 | 68 | M&L earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point complete all as specified and directed.\nNOTE: (i) The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:2:4, type B1 cover 50 mm thick with 8 mm dia TMT bar @ 140 mm C/C, GI watering pipe 20 mm bore medium grade, funnel, wire mesh including filling with charcoal and salt etc. (ii) GI earth strip upto 7.5 metre shall be deemed to be included in the quoted rate and beyond 7.5 metres shall be measured and paid separately under relavent item. | 6 | Each Set | |
| 93 | 69 | Supply and fix fan belts suitable for DG Sets of capacity 30 KVA Capacity including removing the existing unserviceable one complete all as specified and as directed. | 1 | Each | |
| 94 | 70 | All as per Sl. item No. 67 above but 62.5 to 82.5 KVA Capacity | 3 | Each | |
| 95 | 71 | All as per Sl. item No. 67 above but 100 to 200 KVA Capacity | 3 | Each | |
| 96 | 72 | Supply and replace Contactors 3/4 pole, 100 Amps, 230 Volts complete all as specified and as directed. \nMake: CAT No. 3TS47 of SIEMENS or its equivalent in ABB, BCH, L&T, C&S Electric Ltd, Schneider | 3 | Each | |
| 97 | 73 | Supply and replace Contactors 3/4 pole, 120 Amps, 230 Volts complete all as specified and as directed. \nMake: CAT No. 3TS50 of SIEMENS or its equivalent in ABB, BCH, L&T, C&S Electric Ltd, Schneider | 2 | Each | |
| 98 | 74 | Supply and fixing Digital type Ammeter 0-400 Amps , Selector switch class 1.0 including removing existing unserviceable one complete all as directed | 4 | Each | |
| 99 | 75 | Supply and Fixing Digital type Voltmeter 0-500 Volt and selector switch class 1.0 including removing existing unserviceable one complete all as directed | 4 | Each | |
| 100 | 76 | M&L repair to control panel board of DG sets including replacement of defective unserviceable spare parts of PCB body, connected control wiring, suitable connectors, single phase preventor, MNX type contactors, timers, over load relays & other required accessories complete all as specified and directed by Engineer-in-Charge. | 3 | Each Job | |
| 101 | 77 | Supply and replace MCCB of capacity of 400 Amps, 4 pole 36 KA, 415 Volts with thermo magnetic release, adjustable type complete all as specified and directed. | 2 | Each | |
| 102 | 78 | Supply and replace Remote control digital board with hand set of capacity 7.5/8.5 TR including sensor setting complete all as specified and directed.\nMake: Voltas/ Carrier | 1 | Each | |
| 103 | 79 | Supply and fix 15 mm dia Gun metal gate valve, with iron wheel head, screwed both ends for iron pipe and fixed including cutting the pipe line and taking down old unserviceable valves wherever required complete all as specified and directed. | 2 | Each | |
| 104 | 80 | All as per SL item No.79 above but 20 mm dia | 4 | Each | |
| 105 | 81 | All as per SL item No.79 above but 25 mm dia | 5 | Each | |
| 106 | 82 | All as per SL item No.79 above but 40 mm dia | 2 | Each | |
| 107 | 83 | All as per SL item No.79 above but 50 mm dia | 1 | Each | |
| 108 | 84 | Cutting/ cleaning of branches, bushes/plants/ grass obstructing the pipe line/ valve chambers/ sumps/OHTs and path on either sides of water supply installations area including disposal the material up to a distance not execeding 50 m complete all as specified and directed by Engineer-in-Charge. | 2800 | Sqm | |
| 109 | 85 | Supply and replace Remote control digital board with hand set of capacity 5.5 TR including sensor setting complete all as specified and directed.\nMake: Voltas/ Carrier | 1 | Each | |
| 110 | 86 | Supply and laying GI pipes medium grade 15 mm dia with all fittings and fixtures fixed to walls / under floor complete including taking down old unserviceable one all as specified and directed. | 30 | RM | |
| 111 | 87 | All as per SL item No.86 above but 20 mm dia. | 60 | RM | |
| 112 | 88 | All as per SL item No.86 above but 25 mm dia. | 120 | RM | |
| 113 | 89 | All as per SL item No.86 above but 40 mm dia. | 150 | RM | |
| 114 | 90 | All as per SL item No.86 above but 50 mm dia. | 50 | RM | |
| 115 | 91 | M&L for scraping the old painted steel surface of Carrier Air cooled out door unit AC plants and applying the synthetic enamel paint with spray gun of existing colour code of the plants and applying one coat of white wash to PCC foundation including writing of SM/MES No. complete all as specified and directed by Engr-in-Charge. | 4 | Each Job | |
| 116 | 92 | Material & Labour for chemical servicing of the air cooled condenser indoor & outdoor of 5.5/5.8 TR capacities by dismantling the sheet metal parts, apply the organic compound of scale remover to the air cooled condenser fins & tube area, and flushing through forced method, till removal the complete scale deposited across the fins & tube and cleaning, fixing the sheet metal parts, fan blades, etc. all specified as directed by Engineer-in-Charge. | 4 | Each Job | |
| 117 | 93 | All as per Sl. Item No.92 above but of capacity 7.5/8.5 TR | 2 | Each Job | |
| 118 | 94 | M&L masonary valve chamber of size 750x750x750 mm (internal dimensions) and including necessary excavation and earth work in any type of soil, 100 mm thick PCC 1:4:8 type D2 foundation, brick work in cement mortar 1:6, plastering internal and external surface 15 mm thick in CM 1:4, 50 mm thick PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) coping, 50 x 50 x 6 mm thick MS angle iron, 5 mm thick MS plate cover with locking arrangement, painting exposed steel surfaces with two coats of synthetic enamel paint over a coat of zinc chrome primer including dismantling unserviceable compete all as specified and directed by Engr-in-Charge. | 4 | Job | |
| 119 | 95 | All as per Sl. item No. 94 above but of size 1000x1000x1000 mm (internal dimensions) | 2 | Job | |
| 120 | 96 | M&L for cleaning of Over Head Tank of 0.50 lakhs gallons capacity by cleaning out the accumulated water in the bottom and removing the complete silt from the tank and depositing and levelling as directed and cleaning with the bleaching powder, after scrapping the walls and bottom of the tank by using wire brush completely without disturbing the water supply to the area , and applying one coat of white wash inside OH tank and writing details like Cleaning/ due date/ tank capacity with synthetic enamel paint on bottom wall complete all as directed . | 1 | Job | |
| 121 | 97 | Material and labour for taking down unserviceable burnt compressor, Supply and fix new compressor of existing unit make suitable for 7.5/8.5/11 TR air cooled ductable package conditioner/ Package unit and rectify the control wiring defects if any, connecting back all controls and refrigerant piping after necessary modification as required for system, pressure testing with nitrogen gas under constant pressure of 300 PSI Kg/sq.cm for minimum 24 hours vacuumising, gas charging, commissioning and checking the performance of the system all as directed by the Engineer-in-Charge. | 1 | Each Job | |
| 122 | 98 | Supply and replace V-belt suitable to 7.5 TR indoor blower motor complete all as specified and directed\nMake: Fenner/Yule | 2 | Each | |
| 123 | 99 | Supply and replace high pressure brass float valve with PVC ball suitable for fixing to 25 mm dia GI pipe complete all as specified and directed.\n | 1 | Each | |
| 124 | 100 | Supply and replace big cox brass gate valve 15 mm dia complete all as specified and directed.\n | 8 | Each | |
| 125 | 101 | Supply and replace the following spares | |||
| 126 | 101.01 | Contactor 3/4P type MNX-25/32, 230 Volts 50 HZ | 4 | Each | |
| 127 | 101.02 | Over load relay type MN-2, 9-15 Amps including lugs, nuts and bolts. | 3 | Each | |
| 128 | 101.03 | Single phase preventor having feature of phase reverse and single phasing range of EC2-22A auxillary supply 230 Volts, 50 Hz special 5 Seconds\nMake: Softhard/ minilac\n | 2 | Each | |
| 129 | 102 | M&L for disconnecting motor of 02 HP capacity from the existing place (AHU / chiller / condenser unit / cooling tower motor etc.,) and including rewinding the motor with existing gauge super enamelled copper conductor, varnishing and drying, replacement of worn-out bearings (DE& NDE), bush connectors, terminal plate and refixing in original position, connecting cable through terminal block, preparation and painting exposed surfaces with one coat of synthetic enamel paint of existing colour code, testing and commissioning complete all as specified and directed. | 3 | Each Job | |
| 130 | 103 | All as per Sl. Item No.3 above but motor of capacity 3 to 5 HP | 2 | Each Job | |
| 131 | 104 | Supply and replace MCCB of capacity of 160 Amps, 3/4 pole 25 KA, 415 Volts with thermo magnetic release, adjustable type complete all as specified and directed. | 1 | Each | |
| 132 | 105 | Supply and replace MCCB of capacity of 63 Amps, 3 pole 18 KA, 415 Volts with thermo magnetic release, adjustable type complete all as specified and directed. | 2 | Each | |
| 133 | 106 | Supply and replace MCCB of capacity of 100 Amps, 3 pole 18 KA, 415 Volts with thermo magnetic release, adjustable type complete all as specified and directed. | 1 | Each | |
| 134 | 107 | M&L repair to control panel board of CQAE, including replacement of defective unserviceable spare parts of PCB body, connected control wiring, suitable connectors, single phase preventor, MNX type contactors, timers, over load relays & other required accessories complete all as specified and directed by Engineer-in-Charge. | 1 | Each Job | |
| 135 | 108 | Excavating in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation, laying of cable/pipes etc. n exc 10 sq m on plan and getting out in hard/dense soil complete all as specified and directed. | 1 | Cum | |
| 136 | 109 | Material and labour for existing run lead joint for spigot and socket pipes (CI/DI) and fittings of size 100 mm bore pipe complete all as specified and directed by Engr-in-Charge. | 5 | Each | |
| 137 | 110 | All as per SL. Item No.109 above but 150 mm dia | 6 | Each | |
| 138 | 111 | Supply and laying DI K9 water supply pipe lines of size 150 mm bore including taking down old DI water mains with spigot and socket ends and lead joints and recovering lead joints complete all as specified and directed.\nNote:- Earth work will be measured and paid separately. | 33 | RM | |
| 139 | 112 | All as per SL. Item No.111 above but 100 mm dia pipe | 28 | RM | |
| 140 | 113 | Supply and replace Hard drawn copper pipe of size 7/8\" of 18 guage for indoor to outdoor unit in magazine area AC Plant including all necessary connections complete all as directed. | 20 | RM | |
| 141 | 114 | Supply and replace Hard drawn copper pipe of size 5/8\" of 18 guage for indoor to outdoor unit in magazine area AC Plant including all necessary connections complete all as directed. | 20 | RM | |
| 142 | 115 | Supply & replacement of water level indicator, 36\" dia as per IS and including numbering with radium stickering, heavy duty float, counter weight, heavy duty driving gear nylon wire fitted in all in GI housing, cutting the RCC slab of UG sump/ OHT (of any height) and making good the slab, painting the exposed surface with two coats of synthetic enamel over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge. \nNote: Make of water level indicator shall be got approved by GE before procurement. | 1 | Each | |
| 143 | 116 | Supply and replace 150 mm bore CI sluice valves PN 1.6 (raising type) conforming to IS 14846 flanged end with iron wheel head and stainless steel spindle flanged joints including necessary nuts, bolts, and washers etc., complete all as specified and directed. | 1 | Each | |
| 144 | 117 | All as per SL item No.116 above but of size 100 mm dia | 1 | Each | |
| 145 | 118 | All as per SL item No.116 above but of size 80 mm dia | 1 | Each | |
| 146 | 119 | Supply and replace CI specials such as bends (any type, radius and angle) tapers any type, straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch, \"Y\" junction, double branch, cross (all sockets or sockets and spigot) collars, caps and plugs upto 150 mm bore complete all as specified and directed. | 60 | KG | |
| 147 | 120 | Supply and replace DI specials such as bends (any type, radius and angle) tapers any type, straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch, \"Y\" junction, double branch, cross (all sockets or sockets and spigot) collars, caps and plugs upto 200 mm bore. | 60 | KG | |
| 148 | 121 | Disconnecting the delivery pipe line and electric connections of submersible pump set of capacity of 5 HP and lifting and removing it from its position along with pipes and fittings carefully with the help of required T&P and transporting the same to the work shop for repair / servicing/ rewinding with existing gauge super enamelled copper conductor, varnishing and drying and lowering and refixing the same in its original position including connecting up of water and electric connections including testing and commissioning complete all as specified. | 1 | Each Job |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Completed