| 1 | 1 | B/R Items\nSurface excavation in soft loose soil n. exc 30 cm deep and averaging 15 cm deep and getting out. | | 3600 | Sqm |
| 2 | 2 | Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m\nabove the starting point | | 565 | Sqm |
| 3 | 3 | Supply of sweet earth and spreading & levelling in layers n.exe 25cm thick (only approved earth brought out side of Defence land) complete alls specified and directed by Engr-in-Charge. | | 150 | Cum |
| 4 | 4 | Forming embankment Including raising (or lowering) earth spreading in layers not exc 30 cm thick, watering, ramming/rolling to reqd size, shape etc n.exc1.5m high from base. | | 300 | Cum |
| 5 | 5 | Supply and plantation of grass selection No 1 by dibbling root method all as specified with following activities..\n\n(a) Ploughing of whole site in soft /ordinary soil up to variable depth and removing all unwanted materials such as stones, weeds, tree roots etc which are not suitable for healthy growth of trees and grass.\n(b) Dressing and leveling to a required gradient and slope afer loosening the soil. \nc) mixing of fertilizers & manure evenly manually in the ratio as specified and ddirected. \nManure (i) Old cow dung or okhla sludge at the rate of 4 cuft per 10 Sqm.\n(ii) Neem @ 1 kg per 10Sqm.\n(iii) DA (16.42) @ 0.15 kg per 10 Sqm.\n(iv) BHC 10% or lindance dust @ 0.15kg per 10 Sqm.\nNote :- the manure and fertilizers to be mixed evenly up to the depth as directed by engr in charge.\n(d) Fine dressing the top soil after mixing the manure and fertilizer to required slope. \n(e) Watering the area and fine dressing of soil after one week till soil gets water level up to required depth.\n(f) Plantation of grass 10cm c/c both ways by dibbling root mathod.\n(g) maintenance of grass shall be carried out by the contractor till the work is completed. | | 3000 | Sqm |
| 6 | 6.1 | Supply and plantation of sapling of plant and shrubs of following species of 2' minimum height along with activities in under mention note.\n(a) Hemelia Patens | | 50 | Nos |
| 7 | 6.2 | (b) Caliandara Hybrid | | 50 | Nos |
| 8 | 6.3 | (c) Jasminum Humile | | 40 | Nos |
| 9 | 7 | Supply and plantation of sapling of plant of palms and mounds plants of following species along with activities in under mention note.\n\n(a) Phenix Palm minium minimum 2' height ( 10 leaves) | | 50 | Nos |
| 10 | 7.1 | (b) Royal Palm High minimum 6 ' height | | 50 | Nos |
| 11 | 8 | Supply and plantation of hedges and ground covers of different species 8\" to 10\" height along with activities in under mention note. | | 1800 | Nos |
| 12 | 9.1 | Supply and plantation of sapling of decorative and ornamental plants of 4' minimum height along with activities in under mention note.\n\n(a) Yellow duranta (Traporil) | | 50 | Nos |
| 13 | 9.2 | (b) Golden bottle brush \n\nNote No 1 :- Activities for plantation of plants at Sr No 7& 9\n(a) Preparation compost pit for trees and plants of size 750x750x750mm by excavation, applying ATT, planting the tree/plants, refilling the pit with cmposed manure sand and sweet earth in ratio of 1:1:4 breaking the clods/ramming and flooding with water and filling with more composed earth if necessary, fine dressing including removal of rubbish/unserviceable material, ATT shall be in the form of 200 grams Neem cake mixed with every cum of compost follwed by Dursban applied at 2 ml/ltr in the first watering of 20 ltr per pit. \n\nNote No 2 :- Activities for plantation of plants at Sr No 6& 8 \n(a) Preparation compost pit for trees and plants of size 300x300x300 mm by excavation, applying ATT, planting the tree/plants, refilling the pit with cmposed manure sand and sweet earth in ratio of 1:1:4 breaking the clods/ramming and flooding with water and filling with more composed earth if necessary, fine dressing including removal of rubbish/unserviceable material, ATT shall be in the form of 200 grams Neem cake mixed with every cum of compost follwed by Dursban applied at 2 ml/ltr in the first watering of 5 ltr per pit. | | 50 | Nos |
| 14 | 10 | 'E/M Items\nM & L for Boring of tube well in normal strata using manual/ mechanical boring equipment (upto 60 m deep) and not less than 150 mm dia,all as specified and directed by Engr-in-Charge. | | 120 | RM |
| 15 | 11 | Supply and lowering of high density UPVC pipe having pressure not less than 10 kg/Sqcm, 100mm bore including necessay fittings and connections (Socket) etc including PVC ball plug complete all as specified and directed by Engr-in-Charge. | | 84 | RM |
| 16 | 12 | Supply and lowering of slotted pipe, high density UPVC pipe having pressure not less tha 10 Kg/Sqcm, 100mm bore including necessay fittings and connection (Socket) including PVC ball plug complete all as specified and directed by Engr-in-Charge. | | 36 | RM |
| 17 | 13 | Supply, installation, testing and commisioning of submersible pump with starter, totally enclosed with sheet metal enclosure , electric driven motor 230 V, 141.6 LPM 50 mtr head including cloumn pipe 32/40mm heavy grade GI pipe, NRV of suitable size and submersible cable upto starter panel complete all as specified and directed. | | 2 | Each |
| 18 | 14 | M&L for foundation block of size 750mmx750mmx 750mm of PCC 1:2:4 type B 1 (20 mm graded stone aggregate) including necessary form work and fair finish to exposed surface including MS clamp of size 600x100x12mm thick with nut & bolts for holding of casing pipe all as specified and directed. | | 2 | Each\n Job |
| 19 | 15 | S & F cage of size 1.50mx1.50mx1.50m for security of pump made out of mild steel angle iron 40x40x6mm frame and mild steel welded mesh of size 50x50mm, weight not less than 4 Kg/Sqm and PGI sheet 0.63mm thickness in roof covering with locking arrangement including necessary excavation & earth work, PCC and painting etc complete all as specified and directed by Engr-in-Charge. | | 2 | Each\n Job |
| 20 | 16 | S&F MCB DB SPN 4 Way with 200 mm bus bar all as specified. | | 2 | Each |
| 21 | 17 | S&F Isolator DP 32 Amps all as specified. | | 2 | Each |
| 22 | 18 | Supply and laying jointing & testing XLPE insulated PVC sheathed stranded aluiminum armoured electric cable 1100 volt cross sectional area 16 Sqmm, 2 core completed all specified and directed | | 250 | RM |
| 23 | 19 | Supply and fixing/laying galvanised mild steel tubing medium grade 25mm bore with and including all fitting and laying in trenches, complete all as specified and directed by Engr-in-Charge. | | 100 | RM |
| 24 | 20 | S&F 25mm nominal bore gun metal gate valve (Class-1) with iron wheel head, screwed both ends for iron pipe, ISI marked, completed all as specified and directed by Engr-in-Charge. | | 8 | Each |
| 25 | 21 | M&L for providing brick stand post (garden stand post) of size 230x230x300mm built with cement motar (1:4) over PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) bed of size 600x600x150mm thick (75mm thick below ground level) inlcuding all exposed surface of brick work and concrete work shall be plastered with 10mm thick rendering in cm (1:6) surface finished fair and even complete all as specified and directed by Engr-in-Charge. | | 8 | Each Job |
| 26 | 22 | Excavation in trenches not exc. 1.5 m wide and 1.5 m depth and getting out for laying pipe line and cable including trimming bottom surfaces to required level and slope etc as in soft/loose soil complete all as specified and directed | | 125 | Cum |
| 27 | 23 | Returning/filling in trenches including spreading, levelling, watering and well ramming layer not exc 25 cm thick in soft/loose soil complete all as specified and directed | | 100 | Cum |
| 28 | 24 | M & L for sand filling, fine river sand in tenches for under ground cable all as specified and directed ( Punned thickness of sand only will be measured) | | 20 | Cum |
| 29 | 25 | M & L laid in trenches continuous brick class 'B'covering over cables for protection of cables | | 2000 | Each |
| 30 | 26 | Boring under the road/hard standing (depth not less than 0.40m below GL) and dia of bore not less than 40 mm suitable for insertion of 40 mm bore GI pipe complete all as specified and directed. | | 18 | Rm |
| 31 | 27 | M&L for GI Tube light grade of 40 mm bore including all fittings , laying under road / hardstanding for under ground cable complete all as specified and directed. | | 18 | Rm |
| 32 | 28 | Earthing complete with galvanized mild steel earth plate (electrode) 600x600x6mm thick buried directly in gound, earth pit not less than 2.25 mtr deep below gound leven surounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 4 mm dia GI wire as earth wire moulded and riveted to earth plate at one end and connected to main switch/control switch of the building at another end, GI earth wire incased in and including 15 mm dia GI light grade pipe from upper end of earth pate upto main switch/control of the building including 20 mm dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, CI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B1 duly reinforced with MS round bars 6 mm dia @ 150 c/c both ways and with 10 mm dia MS bar in lifting handle, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electrical plate No 3 of SSR Pt-I | | 2 | Each |