Military Engineer Services-MES has published Repair Maintenance Of Internal Wiring Including Fittings Fixtures Ceiling Fans Wall Fans Exhaust Fans Air Circulators Mcb Db S Hangar Lights Earthings Aviation Flood Lights Lightening Conductors And Connected Works For Bldgs And Hangars North Side Runway . Submission Date for this Tender is 20-08-2019. Air Circulators Tenders in VASCO Goa. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
---|---|---|---|---|---|
1 | 1 | Taking down aluminium/copper point wiring (light, fan, socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials for taking credit (credit for above items should be made as per conditions seperately) and making good the disturbed surface all as directed by Engineer-in-Charge. | 230 | Point | |
2 | 2 | Taking down submain wiring Aluminium/ copper of any size including earth continuity condutor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and directed. | 180 | RM | |
3 | 3 | Taking down unserviceable any type of Main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed. | 21 | Each | |
4 | 4 | M&L for Point wiring complete with 1100volt grade PVC insulated unsheathed multistranded 1.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 1.5 sqmm PVC unsheathed copper conductor and connected to earth dolly, including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches sockets etc concealed on wall complete all as specified and directed by Engineer-in-Charge. | |||
5 | 4.01 | (a) One light point controlled by one switch | 90 | Point | |
6 | 4.02 | (b) One call bell point controlled by bell push | 5 | Point | |
7 | 4.03 | (c) One fan/exhaust fan point controlled by one switch & regulator | 30 | Point | |
8 | 4.04 | (d) One 5 Amps socket on independent board | 40 | Point | |
9 | 4.05 | (e) One light point controlled by two, two way switches. | 5 | Point | |
10 | 5 | All as per item No 4 above but one power point complete with 2.5 sqmm copper cable drawn through and incl casing and capping of suitable size and one run of 1.5 sqmm copper cable of upto earth dolly earthing for 15 Amps socket outlet independent. | 60 | Point | |
11 | 6 | S & F in repairs switch piano, flush type single pole, one way 5 Amp all as specified. | 80 | Each | |
12 | 7 | S & F in repairs switch piano, flush type single pole, two way 5 Amp all as specified. | 5 | Each | |
13 | 8 | S & F in repairs switch socket combination 2 in 1, 5 pin, 6 Amp flush type all as specified. | 50 | Each | |
14 | 9 | S & F in repairs switch socket combination 2 in 1, 5 pin 15 amp flush type universal all as specified. | 40 | Each | |
15 | 10 | S & F in repairs switch modular type single pole, one way 6 Amp all as specified. | 40 | Each | |
16 | 11 | S & F in repairs Socket, 6A - 2/3 pin combined 2 module modular type | 40 | Each | |
17 | 12 | S & F in repairs Socket 6A/16A - 2/3 pin combined 2 module modular type | 30 | Each | |
18 | 13 | S & F in repairs for industrial socket with single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps complete all as specified and directed. | 45 | Each | |
19 | 14 | S & F in repairs ceiling rose 2 to 3 terminal 230 volts, PVC polycarbonate, isolated body complete all as directed. | 60 | Each | |
20 | 15 | S & F in repairs call bell ding dong, AC, 230 volts, single phase, 50 HZ complete all as specified and directed. | 5 | Each | |
21 | 16 | S & F in repairs bell push 5 Amp flush type complete as per code 95133. | 5 | Each | |
22 | 17 | S & F in repairs stepped type electronic fan regulator 230 V 5 Step all as specified. | 80 | Each | |
23 | 18 | S & F in repairs lamp holder angle / battern type, insulated body complete all as specified and as directed. | 30 | Each | |
24 | 19 | M & L for sub main wiring with two runs of single core 4 Sqmm FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & incl PVC casing caping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 4 Sqmm single core FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measured as one unit) | 100 | RM | |
25 | 20 | All as per item No 19 here in before, but two run of single core 6 sqmm and one run of 6 sqmm cables as earth continuity conductor all as directed. | 80 | RM | |
26 | 21 | S&F MCB DB SPN double door 8 ways all as specified and directed. | 10 | Each | |
27 | 22 | S&F MCB DB TPN double door 4 way 415 volts all as specified and directed. | 6 | Each | |
28 | 23 | S&F in repairs MCB TPN 'B' series 63 Amp, 415 volts, 50 Hz, 10 KA complete all as specified and directed | 15 | Each | |
29 | 24 | S&F in repairs MCB SP 06 to 32 Amp, 230 volts, complete all as specified and directed. | 125 | Each | |
30 | 25 | S&F in repairs MCB SPN 06 to 32 Amp, 230 volts, complete all as specified and directed. | 40 | Each | |
31 | 26 | S & F in repairs for RCCB , DP, 25 Amp, 100 mA, 230 volts, 50 HZ, 10 KA breaking capacity all as all as specified and directed. | 2 | Each | |
32 | 27 | Supply and fix in repairs LED tube light fitting and tube light 1 x 18 Watts 4 feet long , 230V indoor decorative aluminum extruded LED integrated batten, complete with all accessories internally pre- wired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and directed. \nMake :- wipro/Bajaj/Philips | 300 | Each | |
33 | 28 | Taking down unserviceable tube / CFL light fitting of any wattage and any capacity from any description and re- fixing in the existing position after repairs by replacement of worn out spares / parts like ballast, Bi pin holder, starter holder, capacitor and starter, FTL, CFL all as directed. \n(Note : New spares will be measured and paid as Supply only under relevent item of this schedule) | 130 | Each | |
34 | 29 | Supply only Electronic ballast suitable for for tube light fitting 1 x 36/40 Watt. | 50 | Each | |
35 | 30 | Supply only Electronic ballast suitable for tube light fitting 1 x 18/20 Watt. | 20 | Each | |
36 | 31 | Supply only Electronic ballast suitablefor tube light fitting 2 x 36/40 Watt. | 20 | Each | |
37 | 32 | Supply only Bipin holder complete all as specified and as directed. | 30 | Each | |
38 | 33 | Supply only Starter 20/40 watt complete all as specified and as directed. | 50 | Each | |
39 | 34 | Supply only copper ballasts suitable for CFL lamp 11/18 watt complete all as specified and directed. | 10 | Each | |
40 | 35 | Supply only copper ballasts suitable for 1 x 36/40 watts FTL complete all as specified and directed. | 20 | Each | |
41 | 36 | Supply only copper ballasts suitable for 1 x 18/20 watts FTL complete all as specified and directed. | 10 | Each | |
42 | 37 | S&F in repair laminated sheet of 3 mm thick suitable for switch board as per existing size incl replacement of brass screws complete for fixing switches, sockets, fan regulators etcall as specified and directed by Engineer-in-charge. | 1 | Sq Mtr | |
43 | 38 | Dismantling of ceiling / exhaust / air circulator fans of any make, any sweep from the site , keeping aside in store yard in safe custody for servicing , greasing, and painting including replacement of old and unserviceable nuts , bolt, rubber seal, bush, bearing, capacitor, split pin and reassembling the fan complete including re-fixing at the site where directed. \n(Note: New spares will be measured and paid separately as supply only under relevant items of schedule) | 300 | Each | |
44 | 39 | Supply only rubber seal for hanging ceiling fan suitable for C/fan. | 40 | Each | |
45 | 40 | Supply only MS nut bolt with split pin suitable for C/fan | 40 | Each | |
46 | 41 | Supply only split pin suitable for C/fan. | 40 | Each | |
47 | 42 | Supply only ball bearing suitable for size of c/fan, exhaust fan, air circulator and pedestal fan any type and any make. | 20 | Each | |
48 | 43 | Supply only gun metal bush suitable for c/fan exhaust fan, air circulator and pedestal fan of any size. | 30 | Each | |
49 | 44 | Supply only capacitor of the following capacity including removing old one. \n | |||
50 | 44.01 | a) 2.5 mfd | 200 | Each | |
51 | 44.02 | b) 4 mfd | 30 | Each | |
52 | 45 | M & L opening the body cover of celing fan, exhaust fan, air circulator, pedestal fan any type , any make and cutting the existing winding without damaging the starter removing the coil insulation and putting new wire of suitable gauge with correct number of turns of auxiliary and main winding , varnishing and baking complete and soldering new lead of copper wire three core cables of size 23/0.0076 testing complete including transportation from area of AGE E/M I to workshop all as directed :- | |||
53 | 45.01 | a) C/Fan 1200/1400mm sweep | 110 | Each | |
54 | 45.02 | b) Exhaust fan up to 300 mm sweep | 30 | Each | |
55 | 45.03 | c) Exhaust fan up to 450 mm sweep | 15 | Each | |
56 | 45.04 | d) Wall mounting fan up to 700 mm sweep | 20 | Each | |
57 | 46 | S & F in repairs LED panel 2' x 2' recess mounting luminaire suitable for armstrong/grid/ Pop ceiling complete with separate electronic driver & high brighteness SMD Leds complete all as specified and directed by Engineer-in-Charge.\nMake: Philips, Bajaj, wipro | 30 | Each | |
58 | 47 | S & F in repairs LED panel 4' x 1' recess mounting luminaire suitable for armstrong/grid/Pop ceiling complete with separate electronic driver & high brighteness SMD Leds complete all as specified and directed by Engineer-in-Charge.\nMake Philips, Bajaj, wipro | 10 | Each | |
59 | 48 | Supply and fixing in repairs LED Highbay 150W suitable for Hangers / industrial application, integral industrial SMD LED with pressure die-cast aluminium housing, anodised aluminium reflector, complete with all accessories ,lumen efficiency > 120 lm/w , CRI > 85% ,THD < 15% UL certified. The luminarie should have 5 KV surge protection, PF > 0.95. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engineer-in-Charge.\nMake: C&S: LTEHB150WHPLED/LS or equivalent in Philips/ Wipro\n\n | 10 | Each | |
60 | 49 | Taking down unserviceable high bay/Flood/Hanger/ any type of light fitting from hangar upto 18 mtr height and refixing after replacemetn of new spares like Ballasts, Igmitor, capacitor, lamp & holders ,. etc and refix the same after repair work in the existing place incl replacement of minor spares which is not covered in the schedule complete as directed by Engineer-in-Charge.\nNote: New Spares will be measured & paid under relevant items as supply only | 250 | Each | |
61 | 50 | Supply only heavy duty copper ballast for HPSV/MH 400W high bay fitting complete all as specified and directed by Engineer-in-Charge.\n(Make Philips/ C & S/ Havells) | 70 | Each | |
62 | 51 | Supply only heavy duty copper ballast for HPSVMH 250W high bay fitting complete all as specified and directed by Engineer-in-Charge.\n(Make Philips/ C & S/Havells) | 15 | Each | |
63 | 52 | Supply only HPSV lamps 400W of hangar light fitting complete all as specified and directed by Engineer-in-Charge. \n(Make Philips/ C & S/ Havells) | 25 | Each | |
64 | 53 | Supply only MH lamps 400W of hangar light fitting complete all as specified and directed by Engineer-in-Charge. \n(Make Philips/C & S / Havells) | 60 | Each | |
65 | 54 | Supply only MH lamps 250W of hangar light fitting complete all as specified and directed by Engineer-in-Charge.\n(Make Philips/ C & S/ Havells) | 40 | Each | |
66 | 55 | Supply only ignitor suitable for MV & MH lamp 250-400W complete all as specified and directed by Engineer-in-Charge. \n(Make Philips/C & S/ Havells) | 80 | Each | |
67 | 56 | Supply only Porcelain holder threaded type for 400/250W HPSV/HPMV lamp complete all as specified and directed by Engineer-in-Charge.\n(Make Philips/C & S/ Havells) | 70 | Each | |
68 | 57 | Supply only capacitor 33 mfd, 250V complete all as specified and directed by Engineer-in-Charge. \n(Make Philips/C & S/Havells) | 100 | Each | |
69 | 58 | S&F DB 6 way TPN power coated sheet enclosure fitted with bus bar, DIN channel, neutra link & earthlink complete all as specified and directed by Engineer-in-Charge.. \n(Make Philips/ C & S/ Havells) | 3 | Each | |
70 | 59 | S&F vertical DB 6 way TPN with provision for TP MCCB N3 frame upto 200A in 25Ka, 35 Ka,as incomer, powder coated sheet enclosure fitted with bus bar, DIN channel, neutra link & earthlink complete all as specified and directed by Engineer-in-Charge.\n(Make Philips/C & S/ Havells) | 2 | Each | |
71 | 60 | S&F in repairs MCCB 4 pole, 415 volt, fixed type, 100 amps with breaking capacity 25 KA complete all as specified and directed by Engineer-in-Charge.\n(Make Philips/C & S/ Havells) | 3 | Each | |
72 | 61 | S&F in repairs MCCB 4 pole,415 volt,fixed type, 200 Amps with breaking capacity 35 KA complete all as specified and directed by Engineer-in-Charge.\n(Make Philips/ C & S/ Havells). | 2 | Each | |
73 | 62 | S&F in repairs Hangar aviation obstruction light fitting single LED type without lens colour red suitable to 230 V AC protection weather proof IP 65 as per IS2147 sealed against water and dustscomplete all as specified and directed by Engineer-in-Charge.\n(Make Philips/C & S/ Havells). | 7 | Each | |
74 | 63 | S&F in repairs turbo LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminum extrusion IP 66 200W,as per Cat No. BARFEG 200W LED , giving electric connection and testing complete all as specified and directed by Engineer-in-Charge. \n(Make C & S or equivalent in Philips/Havells) . | 6 | Each | |
75 | 64 | S&F in repairs LED Highbay 80W suitable for Hangers / industrial application, integral industrial SMD LED with pressure die-cast aluminium housing, anodised aluminium reflector, complete with all accessories ,lumen efficiency > 120 lm/w , CRI > 85% ,THD < 15% UL certified. The luminarie should have 5 KV surge protection, PF > 0.95. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engineer-in-Charge.\nMake: C&S: LTEF80WHPLED or equivalent in Philips/ Wipro | 15 | Each | |
76 | 65 | Taking down old unservisable/perishable sub main wiring of any size/core/type from the ceiling of hanger complete with PVC /steel conduit/PVC casing capping including earth continuty conductor, junction boxes etc and making good the disturbed surfaces all as directed by Engineer-in-Charge. | 300 | RM | |
77 | 66 | M & L for circuit/submain wiring of the following sizes of FRLSH PVC insulated copper wire IS - 694 , 1100 Volts grade conductor,single core drawn through and incl stove enamelled steel conduit fixed in surface of wall / beam / trusses / any description with all accessories such as bends, Tees, elbows, . etc incl fixing clamps as required all as directed. | |||
78 | 66.01 | (a) two run of single core 2.5 sqmm and one run of 2.5 sqmm cables as earth continuity conductor all as directed. | 100 | RM | |
79 | 66.02 | (b) four run of single core 2.5 sqmm and two run of 2.5 sqmm cables as earth continuity conductor all as directed. | 200 | RM | |
80 | 67 | S & F LT UG cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor,1100 volts grade, of size 4 core x 6 sq mm fixed on walls / ceilings / trusses of any description incl taking down the old unserviceable cables. all as directed | 200 | RM | |
81 | 68 | S & F LT UG cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor,1100 volts grade, of size 3 1/2 core x 70 sq mm fixed on walls / ceilings / trusses of any description incl taking down the old unserviceable cables. all as directed. | 150 | RM | |
82 | 69 | Taking down old Aluminum strip of size 25 x 3.15mm along with saddles and fixing screws from the roof and down conductors above ground and refixing in the same location with new saddles, nuts and bolts, screws of suitable size and length and connected to air termination rod on top of the hangar complete all as directed. | 50 | RM | |
83 | 70 | S & F in repairs Aluminum strip of size 25 x 3.15mm in repair with saddles and fixing screws etc. for roof conductors and down conductors above ground and fixing in the same location with new nuts and bolts of suitable size and length and connected to air termination rod on top of the hangar complete all as directed. | 170 | RM | |
84 | 71 | M & L Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized earth wire 4 mm dia by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 15mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion including dismantling old one. | 6 | Each | |
85 | 72 | M & L Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4mm as earthing lead by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 40 mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion including dismantling old one. | 7 | Each | |
86 | 73 | S & F in repairs GI clamp/Saddles for fixing of XLPE cable of any size on the wall surface incuding drilling in wall, fixing of new screws suitable length complete all as specified & directed by Engineer-in-Charge. | 500 | Each | |
87 | 74 | S & F in repairs Perforated cable Tray made out of GI sheet of 14 SWG in various sizes including accessories like coupler plate, nut bolts, washers clamps , wall brackets up/down elbows, bends tees etc and fixing with FRP saddles in equal distances on wall/floor/through wall crossing and making good the surface | 3 | Sqm | |
88 | 75 | S & F in repairs LED highbay 200W with fin ventilation technology for better thermal management and with cutting edge LED technology, giving electric connection and testing complete all as specified and directed by Engineer-in-Charge. \n(Make as per Shakti Cat No SZHHCMX200 or equivalent Philips/Bajaj) . | 6 | Each | |
89 | 76 | Supply and fix in repairs LED tube light fitting and tube light 1 x 10 Watts 2 feet long ,230V indoor decorative aluminum extruded LED integrated batten, complete with all accessories internally pre- wired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and directed. | 100 | Each | |
90 | 77 | S & F in repair Analog type 24 hrs timer switches suitable for operation of street light luminarie with 4 pole Power contacotr of 32 A capacity - 01 (Nos) suitable for 3 Phase, 4 wire system incl necessary MCB TPN 6-32 A capacity - 01 (Nos) as control the system, fixed in the Outdoor type LT junction box madeup of powder coated CRCA sheet steel enclosure 3 mm thick floor mounted of suitable size all as specified and as directed. | 2 | Each | |
91 | 78 | S & F in repairs Air Circulator heavy duty of 600 mm Sweep and having 1440 RPM. Make: Havells or eqivalent in Bajaj/C & S | 6 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail