Border Security Force-BSF has published Repair And Maintenance Of Amf And Distribution Panels And Mfp And Sfp Of Bfl Panels Installed At Bop Bolaitilla_Bop Nallua And Bop Madhavnagar In Aor Of 31 Bn Bsf Under Shq Bsf Udaipurrepair And Maintenance Of Amf And Distribution Panels And Mfp And Sfp. Submission Date for this Tender is 08-08-2019. Electrical Panel Tenders in Border area of 31 Bn Tripura. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
---|---|---|---|---|---|
1 | 1 | Laying and Jointing PVC Pipe. Heading | BI01010001010000000000000515BI0100001112 | ||
2 | 1.01 | Providing and fixing MCX32, 4 pole contactor, 160 amp in existing panel board including drilling holes in existing cubical panel, making connections including dismantling of defective contractor (Including deducting the cost of old scapped material) etc as reqd.make L&T code No,CS97020, frame size 4 or its compatible to Havells/Standard/Legrand/C&S. | BI01010001010000000000000515BI0100001113 | 7 | Nos |
3 | 2.01 | Providing and fixing MCX22, 4 pole contactor, 100 amp in existing panel board including drilling holes in existing cubical panel, making connections including dismantling of defective contractor (Including deducting the cost of old scapped material) etc as reqd.make L&T code No,CS97017, frame size 4 or its compatible to Havells/Standard/Legrand/C&S. | BI01010001010000000000000515BI0100001114 | 4 | Nos |
4 | 3.01 | Providing and fixing 160 amp MCCBs, 4 pole with breaking capacity 36 KA, 415 volts with suitable operating mechanism extended rotary handle and spreader terminal in existing cubical panel board including drilling holes in cubical panel, making connections (Including deducting the cost of old scapped material) etc as reqd.Make-L&T Cat No.CM98065OONO or its equivalent make of Havells/Standard/ Legrand/C&S. | BI01010001010000000000000515BI0100001115 | 6 | Nos |
5 | 4.01 | Providing and fixing 32 amps, 415 volt, TPN Disconnector fuse switch unit open execution with suitable HRC fuse link, for fixing in existing SS enclosure with door interlock facility including dismantling of defective one, drilling holes complete with connections, testing, commissioning etc as reqd. L&T make cat no.SK95703or its compatible to Havells/or its equivalent make of Havells/Standard/ Legrand/C&S. | BI01010001010000000000000515BI0100001116 | 3 | Nos |
6 | 5.01 | Providing and fixing 63 amps ,415 volt ,TPN Disconnector fuse switch unit open execution with suitable HRC fuse link, for fixing in existing SS enclosure with door interlock facility including dismantling of defective one, drilling holes complete with connections, testing, commissioning (Including deducting the cost of old scapped material) etc as reqd. L&T make cat no.SK95704 or its compatible to Havells/or its equivalent make of Havells/ Standard/legrand. | BI01010001010000000000000515BI0100001117 | 9 | Nos |
7 | 6.01 | Providing and fixing 125 amps, 415 volt, TPN Disconnector fuse switch unit open execution with suitable HRC fuse link, for fixing in existing SS enclosure with door interlock facility including dismantling of defective one, drilling holes complete with connections, testing, commissioning (Including deducting the cost of old scapped material) etc as reqd. L&T make cat no.SK95001 or its compatible to Havells/or its equivalent make of Havells/Standard/Legrand. | BI01010001010000000000000515BI0100001118 | 3 | Nos |
8 | 7.01 | Providing and fixing 250 amps, 415 volt, TPN Disconnector fuse switch unit open execution with suitable HRC fuse link, for fixing in existing SS enclosure with door interlock facility including dismantling of defective one, drilling holes complete with connections, testing, commissioning (Including deducting the cost of old scapped material) etc as reqd. L&T make cat no.SK95642 or its compatible to Havells/or its equivalent make of Havells/Standard/Legrand/C&S. | BI01010001010000000000000515BI0100001119 | 1 | Nos |
9 | 8.01 | Supplying, installation, testing and commissioning of Combined Digital type display meter suitable for measuring Ac voltage, current, KWH, KW, PF Frequency etc having three line display 3 phase multifunction meter in existing cubical panel board including, making connections (Including deducting the cost of old scapped material) etc as reqd. Make L&T code No.WL441010OOOO or its equivalent make of havells/seimens/Legrand/C&S. | BI01010001010000000000000515BI0100001120 | 3 | Nos |
10 | 9.01 | Supplying and making interconnections with following size of single core PVC insulated 1.1 KV grade copper conductor cable between switch gears, bus bars etc of existing panel including providing suitable size cable lugs/ thimbles (Including deducting the cost of old scapped material) etc complete as required.(Finolex/KEI /Havells/L&T/polycab). | BI01010001010000000000000515BI0100001121 | ||
11 | 9.02 | i)10 SQMM single core Heavy Duty copper cable. | BI01010001010000000000000515BI0100001122 | 15 | Mtr |
12 | 9.03 | ii)35 SQmm single core Heavy Duty copper cable. | BI01010001010000000000000515BI0100001123 | 15 | Mtr |